FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Alinco Incorporated, Electronics Division/
  3. PH3DJ-A41

PH3DJ-A41Two-Way Radio

Alinco Incorporated, Electronics Division
Two-Way Radio - FCC ID PH3DJ-A41 - Alinco Incorporated, Electronics Division
Click to zoom

Application Details

Equipment Class
TNF - Licensed Non-Broadcast Transmitter Held to Face
Date of Grant
Jun 24, 2014
Application Purpose
Original Equipment
Date of Application
Jun 24, 2014
Equipment Note
Two-Way Radio
Frequency Range
406.10000000 - 470.00000000
Company
Alinco Incorporated, Electronics Division
Country
Japan

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Thank you for purchasing your new Alinco transceiver. Please read this manual carefully before using the product to ensure full performance, and keep this manual for future reference as it contains information on after-sales service. In case addendum or errata sheets are included with this product, please read those materials and keep them together with this instruction manual for future reference. Instruction Manual UHF FM Transceiver FCC ID:PH3DJ-A41 IC:3070C-DJA41 Conformity Symbols Tested to comply MIL-STD-810G -Shock: Method 514.6/I,IV -Vibration: Method 516.6/I DJ-A41 Introduction Thank you very much for purchasing this excellent Alinco transceiver. Our products are ranked among the finest in the world. This radio has been manufactured with state of the art technology and it has been tested carefully at our factory. It is designed to operate to your satisfaction for many years under normal use. Please read this manual completely from the first page to the last, to learn all the functions the product offers. It is important to note that some of the operations may be explained in relation to information in previous chapters. By reading just one part of the manual, you may risk not understanding the complete explanation of the function. Before transmitting There are many radio stations operating in the frequency ranges this product covers. Be careful not to cause interference when transmitting around such radio stations. ■ Lightning Any person is not safe outdoor during thunderstorm and lightning. This condition is getting worse if somebody keeps a hand-held radio; chances of being hit by lightning are doubled since lightning may hit a radio antenna as well. At this time, there is no hand-held radio having any kind of protection against lightning current (which is higher than10 kA.). Note also that no car provides adequate protection of its passengers or drivers against lightning as well. Therefore, Alinco will not take responsibility for any danger associated with using its hand-held radios outdoor or inside the car during lightning. ■ About IP54 rating / Dust and splash resistant About IP54 rating 5: Dust protected /Ingress of dust is not entirely prevented, but it must not enter in sufficient quantity to interfere with the satisfactory operation of the equipment; complete protection against contact. 4: Splashing water / Water splashing against the enclosure from any direction shall have no harmful effect. Test duration: 5 minutes / Water volume: 10 litters per minute /Pressure: 80~100 kN/m² The IP54 designation provides for limited dust and splash proofing of the radio per specified above. This compatibility is factory guaranteed for a period of one year provided all the jack covers are securely in place, any accessories connected must be specified genuine Alinco accessories and the radio has not been disassembled by the customer. The factory has tested and made the equipment compatible to IP54 certification during engineering. However, please understand that this equipment is NOT certified IP54 compliant but is designed to remain operational when used in hard conditions and is in no way stating that you should attempt to wash the radio for cleaning. Warranty will not cover radios that are water/dust damage due to negligence or misuse of the product. The warranty period of dust and splash resistance is the same as the period of the product warranty. ■ Covering ranges You may expect a range of approx.3km/2 miles or more at high-power when located on a flat, noise-free place like on a beach.However,it may vary drastically depending on how to wear and carry the radios, surrounding locations/conditions and static noise levels (below or near power transmission lines), etc. In urban areas with many buildings or inside a building, such covering range will become drastically short even to several tens of meters. ■ Output power 5W ■ 128 PC-programmable channels (16ch x 8groups) ■ Li-Ion battery pack and stand-charger as standard accessories ■ Voice Compander (Reduce Noise & enhance audio clarity) ■ Inversion Scramble(Analog encryption) ■ Sub-tone (CTCSS/DCS) Encode/Decode and DTMF ■ VOX built-in Features Conformity Symbols Tested to comply MIL-STD-810G -Shock: Method 514.6/I,IV -Vibration: Method 516.6/I SAFETY TRAINING INFORMATION Warning: Please Read Carefully • DO NOT operate the transceiver without a proper antenna attached, as it may damage the transceiver and may also cause you to exceed FCC RF exposure limits. A proper antenna is the genuine antenna supplied with this transceiver by Alinco or ones specifically authorized by the antenna manufacturer for use with this transceiver. • the original belt clips when attaching the transceiver to your body (Unauthorized attachment devices may • Use only the genuine Alinco accessories listed in this instruction manual for RF safety. Third party accessories are not guaranteed for RF safety by Alinco. • Electromagnetic Interference/Compatibility During transmissions, a transceiver generates RF energy that can possibly cause interference with other devices and/or systems. To avoid such interference, turn off the transceiver in areas where signs are posted to do so. NEVER operate transceivers in areas that are sensitive to electromagnetic radiation such as hospitals, blasting sites, aboard aircraft and similar advanced vehicles etc. Do not expose magnetic cards such as credit cards in a very close vicinity to a transceiver; it may erase the magnetic data. A person using medical devices such as a pacemaker MUST NOT use this transceiver, as interference may cause malfunction to such medical devices. ALWAYS keep the antenna at least 2.5cmaway from your body when transmitting and only use help radiating more electromagnetic energy). Alert Environment and condition of use Use of this product may be prohibited or illegal outside of your country. Be informed in advance when you travel. It is recommended that you check local traffic regulations regarding …

Text truncated - open the document above for the full version.

Cover Letter(s)

Alinco Incorporated, Electronics Division Yodoyabashi-Dai Bldg 13F,4-4-9, Koraibashi, Chuo-ku Osaka 541-0043 Japan Tel: 06-7636-2360 Fax: 06-6208-3801 May 27.2014 To: Federal Communication Commission Authorization and Evaluation Division Subject: Attestation statement regarding the Land Mobile Radio frequency TYPE OF QEUIPMENT: Licensed Non-Broadcast Transmitter Held to Face FCC ID: PH3DJ-A41 Dear Sir or Madam I attest that the product could program the frequence on computer through interface by manufacturer, is incapable of tuning, or readily being altered, by the end-user. Please contact the undersigned if you have any questions or need any further information. Regards Alinco Incorporated, Electronics Division Signature: Name, Job Title and Dept.: Kazuhiro Kusuhara / General Manager

Cover Letter(s)

May 27, 2014 Federal Communication Commission Authorization and Evaluation Division FCC ID: PH3DJ-A41 Re: Confidentiality Request Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, the applicant hereby requests confidential treatment of information applied this application as outlined below: 1: Block Diagram 2: Circuit Diagram 3: Operational Description 4: Parts List 5.Tune Up Procedure The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rules 0.457, disclosure of this Application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Alinco, Incorporated, Electronics Division Contact person: Kazuhiro Kusuhara Title: General manager

Cover Letter(s)

Alinco Incorporated, Electronics Division Yodoyabashi-Dai Bldg 13F,4-4-9, Koraibashi, Chuo-ku Osaka 541-0043 Japan Tel: 06-7636-2360 Fax: 06-6208-3801 Jun.25.2014 To: Federal Communication Commission Authorization and Evaluation Division Subject: Attestation statement regarding the Land Mobile Radio TYPE OF QEUIPMENT: Licensed Non-Broadcast Transmitter Held to Face FCC ID: PH3DJ-A41 Dear Sir or Madam I attest that the product has one antenna, one battery capacity and one body- worn and audio accessories. Please contact the undersigned if you have any questions or need any further information. Regards Alinco Incorporated, Electronics Division Signature: Name, Job Title and Dept.: Kazuhiro Kusuhara / General Manager

Cover Letter(s)

May 27, 2014 Federal Communication Commission Authorization and Evaluation Division Subject: FCC ID: PH3DJ‐A41 Justification Letter for Expanded Frequency Range 400‐470MHz Gentlemen; You have asked Alinco Incorporated, Electronics Division for justification to have the freq range 400‐470MHz appears on the face of the FCC Grant of Certification for a FCC Part 90 Certification. This frequency range is regarded as usual & customary by United States Federal Government and its various departments, user organizations and the military to appear on the face of the equipment Grant of Certification. Sincerely, Alinco Incorporated, Electronics Division Kazuhiro Kusuhara /Manager

External Photos

External Photos TOTAL VIEW OF EUT TOP VIEW OF EUT BOTTOM VIEW OF EUT FRONT VIEW OF EUT BACK VIEW OF EUT LEFT VIEW OF EUT RIGHT VIEW OF EUT

ID Label/Location Info

FCC ID/IC Label Location FCC RF Warning Label UHF FM HANDHELD TRANSCEIVER Model: DJ-A41 Brand Name: ALINCO FCC ID: PH3DJ-A41 IC:3070C-DJA41

Internal Photos

Internal Photos OPEN VIEW OF EUT-1 OPEN VIEW OF EUT-2 OPEN VIEW OF EUT-3 INTERNAL VIEW OF EUT - 1 INTERNAL VIEW OF EUT - 2

RF Exposure Info

+` ` FCC ID APPLIC Produc Brand Model Client Date of STAND REPOR A CAUTIO This rep laborato CATION PUR ct Designati Name Name f Issue DARD(S) RT VERSION Attestat ON: port shall n ory and sha SA Rep : RPOSE : ion : : : : : : : tion of G ot be repro all not be q R Te port No.: A PH3DJ‐A 4 Original E UHF FM H ALINCO DJ‐A41 Alinco In c May.13,2 0 IEEE Std. 47CFR § 2 IEEE/ANS V1.0 Global C oduced exc uoted out o est AGC0058 41 Equipment HANDHELD T corporated, E 014 1528:2003 2.1093 SI C95.1 Complia cept in full w of context. Rep 89140301 TRANSCEIVE Electronics D ance(Sh without the Report port 1FH01 ER Division henzhen e written p No.: AGC01 t n) Co., L ermission 1570140301 Page 1 Ltd. of the test FH01 of 64 Report No.: AGC01570140301FH01 Page 2 of 64 Report Revise Record Report Version Revise Time Issued Date Valid Version Notes V1.0 / May.13,2014 Valid Original Report App App Man Man Prod Bran Mod Diffe EUT App Te st Perf Rep plicant Name plicant Addre nufacturer N nufacturer A duct Name nd Name del Name erence Desc T Voltage plicable Stan t Date formed Loca port Templat e ess Name Address cription ndard ation te Tes Alinco Yodoy Alinco Yodoy UHF F ALINC DJ-A4 N/A DC7.4 IEEE 47CF IEEE / May.1 Attest 2F, Bu Street AGCR Teste Check e Authoriz st Rep o Incorporate yabashi Dai- o Incorporate yabashi Dai- FM HANDHE CO 41 4V by batter Std. 1528:2 R § 2.1093 /ANSI C95.1 3,2014 tation of Glo uilding 2, No t, Bao'an Dis RT-EC-PPT/ d By ed By zed By port C ed, Electron -Bldg 13F, 4 ed, Electron -Bldg 13F, 4 ELD TRANS ry 003 1 obal Complia o.1-No.4, Ch strict, Shenz /SAR (2013- Eric Zh Angela Solger Z Certific nics Division 4-4-9 Koraiba nics Division 4-4-9 Koraiba SCEIVER ance (Shenz haxi Sanwei zhen, China -03-01) hou a Li hang Report cation ashi, Chuo-K ashi, Chuo-K zhen)Co., Ltd i Technical I May.13,201 May.13,201 May.13,201 No.: AGC01 n Ku, Osaka 5 Ku, Osaka 5 d. ndustrial Pa 4 4 4 1570140301 Page 3 541-0043, Ja 541-0043, Ja ark, Gushu, FH01 of 64 apan apan Xixiang Report No.: AGC01570140301FH01 Page 4 of 64 TABLE OF CONTENTS 1. SUMMARY OF MAXIMUM SAR VALUE ....................................................................................................... 5 2. GENERAL INFORMATION ............................................................................................................................ 6 2.1. EUT Description .................................................................................................................................... 6 2.2. Test Procedure ...................................................................................................................................... 7 2.3. Test Environment ................................................................................................................................... 7 3. SAR MEASUREMENT SYSTEM ..................................................................................................................... 8 3.1. Specific Absorption Rate (SAR) ............................................................................................................. 8 3.2. SAR Measurement Procedure ............................................................................................................... 9 3.3. COMOSAR System Description .......................................................................................................... 10 3.4. COMOSAR E-Field Probe ................................................................................................................... 12 3.5. Isotropic E-Field Probe Specification .................................................................................................... 12 3.6. Robot .................................................................................................................................................. 12 3.7. Video Positioning System .................................................................................................................... 13 3.8. Device Holder...................................................................................................................................... 13 3.9. Elliptic Phantom .................................................................................................................................. 14 4. TISSUE SIMULATING LIQUID ..................................................................................................................... 15 4.1. The composition of the tissue simulating liquid ..................................................................................... 15 4.2. Tissue Calibration Result ..................................................................................................................... 16 4.3. Tissue Dielectric Parameters for Head and Body Phantoms ................................................................. 17 5. SAR MEASUREMENT PROCEDURE ......................................................................................................... 18 5.1. SAR System Validation Procedures ..................................................................................................... 18 5.2. SAR System Validation ........................................................................................................................ 19 6. EUT TEST POSITION ................................................................................................................................... 21 6.1. Body Worn Position ............................................................................................................................. 21 7. SAR EXPOSURE LIMITS ............................................................................................................................ 22 8. TEST EQUIPMENT LIST ............................................................................................................................. 23 9. CONDUCTED POWER MEASUREMENT .............................................…

Text truncated - open the document above for the full version.

RF Exposure Info

Report No.: AGC01570140301FH01 Page 37 of 64 APPENDIX C. TEST SETUP PHOTOGRAPHS &EUT PHOTOGRAPHS Test Setup Photographs Face Up with 2.5 cm Separation Distance. Body Back Touch with all accessories 25mm Report No.: AGC01570140301FH01 Page 38 of 64 DEPTH OF THE LIQUID IN THE PHANTOM—ZOOM IN Note:The position used in the measurement were according to IEEE 1528-2003 Report No.: AGC01570140301FH01 Page 39 of 64 EUT PHOTOGRAPHS TOTAL VIEW OF EUT TOP VIEW OF EUT Report No.: AGC01570140301FH01 Page 40 of 64 BOTTOM VIEW OF EUT FRONT VIEW OF EUT Report No.: AGC01570140301FH01 Page 41 of 64 BACK VIEW OF EUT LEFT VIEW OF EUT Report No.: AGC01570140301FH01 Page 42 of 64 RIGHT VIEW OF EUT OPEN VIEW OF EUT-1 Report No.: AGC01570140301FH01 Page 43 of 64 OPEN VIEW OF EUT-2 OPEN VIEW OF EUT-3 Report No.: AGC01570140301FH01 Page 44 of 64 INTERNAL VIEW OF EUT - 1 INTERNAL VIEW OF EUT - 2 Report No.: AGC01570140301FH01 Page 45 of 64 APPENDIX D. PROBE CALIBRATION DATA Report No.: AGC01570140301FH01 Page 46 of 64 Report No.: AGC01570140301FH01 Page 47 of 64 Report No.: AGC01570140301FH01 Page 48 of 64 Report No.: AGC01570140301FH01 Page 49 of 64 Report No.: AGC01570140301FH01 Page 50 of 64 Report No.: AGC01570140301FH01 Page 51 of 64 Report No.: AGC01570140301FH01 Page 52 of 64 Report No.: AGC01570140301FH01 Page 53 of 64 Report No.: AGC01570140301FH01 Page 54 of 64 Report No.: AGC01570140301FH01 Page 55 of 64 APPENDIX E. DIPOLE CALIBRATION DATA Report No.: AGC01570140301FH01 Page 56 of 64 Report No.: AGC01570140301FH01 Page 57 of 64 Report No.: AGC01570140301FH01 Page 58 of 64 Report No.: AGC01570140301FH01 Page 59 of 64 Report No.: AGC01570140301FH01 Page 60 of 64 Report No.: AGC01570140301FH01 Page 61 of 64 Report No.: AGC01570140301FH01 Page 62 of 64 Report No.: AGC01570140301FH01 Page 63 of 64 Report No.: AGC01570140301FH01 Page 64 of 64

Test Report

Report No.: AGC00589140301FE09 Page 1 of 54 Report No.: AGC00589140301FE09 FCC ID : PH3DJ‐A41 IC ID : 3070C‐DJA41 PRODUCT DESIGNATION : UHF FM HANDHELD TRANSCEIVER BRAND NAME : ALINCO MODEL NAME : DJ‐A41 CLIENT : Alinco Incorported, Electronics Division DATE OF ISSUE : May 22, 2014 STANDARD(S) : FCC Part 90& RSS‐119 Rules REPORT VERSION : V 1.0 Attestation of Global Compliance (Shenzhen) Co., Ltd. CAUTION: This report shall not be reproduced except in full without the written permission of the test laboratory and shall not be quoted out of context. FCC Part 90& RSS­119 Test Report Report No.: AGC00589140301FE09 Page 2 of 54 REPORT REVISE RECORD Report Version Revise Time Issued Date Valid VersionNotes V1.0 / May 22, 2014Valid Original Report Report No.: AGC00589140301FE09 Page 3 of 54 VERIFICATION OF COMPLIANCE Applicant: Alinco Incorported, Electronics Division Yodoyabashi Dai-Bldg 13F, 4-4-9 Koraibashi, Chuo-Ku, Osaka 541-0043, Japan Manufacturer: Alinco Incorported, Electronics Division Yodoyabashi Dai-Bldg 13F, 4-4-9 Koraibashi, Chuo-Ku, Osaka 541-0043, Japan Product Designation: UHF FM HANDHELD TRANSCEIVER Brand Name: ALINCO Model Name: DJ-A41 Hardware Version: V1.00 Software Version: V2.02 Date of Test: Mar.27,2014 to May 08, 2014 We hereby certify that: The above equipment was tested by Attestation of Global Compliance (Shenzhen) Co., Ltd. The data evaluation, test procedures, and equipment configurations shown in this report were made in accordance with the procedures given in ANSI C 63.4:2003 and TIA/EIA 603. The sample tested as described in this report is in compliance with the FCC Rules Part 90 and RS-119 requirements The test results of this report relate only to the tested sample identified in this report. Tested By : Bart Xie May 22, 2014 Reviewed By : Kidd Yang May 22, 2014 Approved By: Solger Zhang May 22, 2014 Report No.: AGC00589140301FE09 Page 4 of 54 TABLE OF CONTENTS TABLE OF CONTENTS ...................................................................................................... 4 1. GENERAL INFORMATION ............................................................................................. 7 1.1 PRODUCT DESCRIPTION ................................................................................................... 7 1.2 RELATED SUBMITTAL(S) / GRANT (S) ............................................................................... 8 1.3 TEST METHODOLOGY ......................................................................................................... 8 1.4 TEST FACILITY ...................................................................................................................... 8 1.5 SPECIAL ACCESSORIES ...................................................................................................... 8 1.6 EQUIPMENT MODIFICATIONS ............................................................................................. 8 2. SYSTEM TEST CONFIGURATION ................................................................................. 9 2.1 EUT CONFIGURATION ......................................................................................................... 9 2.2 EUT EXERCISE ..................................................................................................................... 9 2.3 GENERAL TECHNICAL REQUIREMENTS ........................................................................... 9 2.4 CONFIGURATION OF TESTED SYSTEM .......................................................................... 9 3. SUMMARY OF TEST RESULTS .................................................................................. 10 4. DESCRIPTION OF TEST MODES ................................................................................. 11 5. CONDUCTED LIMITS ................................................................................................... 12 5.1 PROVISIONS APPLICABLE ................................................................................................ 12 5.2 MEASUREMENT PROCEDURE.......................................................................................... 12 5.3 TEST SETUP BLOCK DIAGRAM ........................................................................................ 13 5.4 TEST EQUIPMENT USED ................................................................................................... 13 5.5 TEST RESULT ...................................................................................................................... 14 6. FREQUENCY TOLERANCE ......................................................................................... 16 6.1 PROVISIONS APPLICABLE ................................................................................................ 16 6.2 MEASUREMENT PROCEDURE.......................................................................................... 16 6.3 TEST SETUP BLOCK DIAGRAM ........................................................................................ 17 6.4 TEST EQUIPMENT USED: ................................................................................................. 17 Report No.: AGC00589140301FE09 Page 5 of 54 6.5 TEST RESULT .................................................................................................................... 17 7. EMISSION BANDWIDTH .............................................................................................. 20 7.1 PROVISIONS APPLICABLE ................................................................................................ 20 7.2 MEASUREMENT PROCEDURE.......................................................................................... 20 7.3 TEST SETUP BLOCK DIAGRAM ........................................................................................ 20 7.4 MEASUREMENT EQUIPMENT USED: ............................................................................... 20 7.5 MEASUREMENT RESULT: .......................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

APPENDIX IV PHOTOGRAPHS OF TEST SETUP CONDUCTED EMISSION TEST SETUP RADIATED TEST SETUP

Contact Information

Applicant

Kazuhiro Kusuhara(General Manager, Production, Electronics Div.)
[email protected]06-7636-2360Fax: 06-6208-3801

Test Firm

Attestation of Global Compliance Shenzhen Co. Ltd.Forrest Lei
[email protected]86-755-29081966Fax: 86-755-26008484

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
29406.1 MHz - 470 MHz5 W11K0F3E0.2 ppm
Confidentiality
Long Term
Grant Notes
Power output listed is ERP. This device must be restricted to work-related operations only in an Occupational/Controlled RF exposure environment and must operate with a duty factor not exceeding 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled Exposure limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Body-worn SAR compliance is limited to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum of 2.5cm separation between the device, including its antenna, and the user's body. The highest reported SAR values are: Head: 2.69 W/kg, Body-worn: 7.33 W/kg when operating at 50% duty cycle.

Other Applications from Alinco Incorporated, Electronics Division

PH3-DR-B185TMKII

VHF FM TRANSCEIVER

Apr 15, 2026

Equipment Class

CSR - Scanning Receiver
VHF/UHF DUAL BAND FM TRANSCEIVER - FCC ID PH3-DJ-W70HT - Alinco Incorporated, Electronics Division
PH3-DJ-W70HT

VHF/UHF DUAL BAND FM TRANSCEIVER

Jun 06, 2025

Equipment Class

JAV - Other Non-Digital SDoC Devices
UHF FM TRANSCEIVER - FCC ID PH3DJ-G46T - Alinco Incorporated, Electronics Division
PH3DJ-G46T

UHF FM TRANSCEIVER

Nov 19, 2023

Equipment Class

TNF - Licensed Non-Broadcast Transmitter Held to Face
VHF FM TRANSCEIVER - FCC ID PH3DR-CS25 - Alinco Incorporated, Electronics Division
PH3DR-CS25

VHF FM TRANSCEIVER

Dec 14, 2022

Equipment Class

CSR - Scanning Receiver
DMR VHF/UHF MOBILE TRANSCEIVER - FCC ID PH3DR-MD520T - Alinco Incorporated, Electronics Division
PH3DR-MD520T

DMR VHF/UHF MOBILE TRANSCEIVER

May 31, 2021

Equipment Class

CSR - Scanning Receiver