FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Alinco Incorporated, Electronics Division/
  3. PH3DJ-G29T

PH3DJ-G29TDJ-G29T 222/902MHz Dual Band FM Transceiver

Alinco Incorporated, Electronics Division
DJ-G29T 222/902MHz Dual Band FM Transceiver - FCC ID PH3DJ-G29T - Alinco Incorporated, Electronics Division
Click to zoom

Application Details

Equipment Class
CSR - Scanning Receiver
Date of Grant
Nov 20, 2011
Application Purpose
Original Equipment
Date of Application
Nov 20, 2011
Equipment Note
DJ-G29T 222/902MHz Dual Band FM Transceiver
Frequency Range
902.00000000 - 927.99500000
Company
Alinco Incorporated, Electronics Division
Country
Japan

Documents & Files

Select a file to view

Users Manual

↗
↗
↗
↗
↗
↗
↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DJ-G29T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2011180 Page 29 of 58 Appendix L: Manual Please see the following pages. 222/902MHz DUAL BAND FM TRANSCEIVER DJ-G29T 29 222/902MHz FM amateur radio handheld transceiver DJ-G29T For Customers in Canada : MODEL : 3070C-DJG29T An operator’s license is required for this device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. EA-203 The following accessories are supplied with the DJ-G29T. Please confirm that nothing is missing before using the product. Standard accessory may vary depending on the model you have purchased. Contact your local dealer for information on specifications of standard accessories and warranty details. DJ-G29T Transceiver Program Scan Mode 9 69 70 70 71 72 73 73 73 84 84 72 74 75 75 76 76 77 77 78 78 79 79 72 71 71 7 PTT delay 95 94 94 How to enter clone mode Transferring Date 89 88 88 89 90 94 95 96 97 99 100 101 102 105 106 103 102 101 99 99 98 103 107 102 Keep the radio out of the reach of children. a The IPX7 designation provides specifications for limited waterproofing of the radio. The specifications are immersion in one meter (approx 3ft) of still sweet water for up to 30 minutes to warranty the product mainly for use in rain or snow. This compatibility is factory guaranteed for a period of one year provided all the jack covers are securely in place, any accessories connected must be genuine Alinco waterproof accessories and the radio has not been disassembled by the customer. The factory has tested and About 902MHz frequency operations the 902MHz band than on the 222MHz band. This is because the 902MHz signal is prone to instability, especially in the case of mobile operation; it is not due to a malfunction of the product. drift during a contact especially on 902MHz. This is due to conditions at the other station and not due to a malfunction of DJ-G29T. sourse such as florescent lights especially on 902MHz band but it is not a defect. made the equipment compatible to IPX7 certification during engineering. However, please understand that this equipment is NOT certified IPX7 compliant but is designed to remain operational when used in rain, severe weather or in accidental cases of dropping it in water when used in extreme conditions and is in no way stating that you should attempt use the radio under water or submerge the radio for cleaning. Warranty will not cover radios that have water / salt damage due to negligence or misuse of the product (902MHz bandwidth - 51.65MHz) x integral multiple = 902MHz bandwidth frequencies (222MHz bandwidth - 51.65MHz) x integral multiple = 902MHz bandwidth frequencies (222MHz bandwidth - 51.65MHz) x integral multiple = 222MHz bandwidth frequencies

Users Manual

The DJ-G29T has the following features: The DJ-G29T is a dual band handheld transceiver that allows transmitting and receiving on 902MHz frequencies as well as 222MHz. The DJ-G29T includes a VOX function allowing “hands-free” contacts. G29T CAUTION! TRANSMITTING WITHOUT AN ANTENNA MAY DAMAGE THE TRANSCEIVER. jack of the DJ-G29T, then plug the adapter I Use only reliable power supply of specific DC output renge and be mindful of the polarity of the cable and DC-jack. Do not plug the power supply into the wall socket if the contacts are dirty. Short-circuit and/or overheating may result in fire, electric shock and/or damage to the product. vary depending on the product you have purchased. DJ-G29T. 74 for cleaning. common short-circuit Never attempt to charge alkaline or dry cell batteries. This will damage not only the battery case but also the transceiver. 223.500 915.000

Users Manual

223.500 915.000 223.500 915.000 (FM and NFM). 223.500 915.000 223.500 915.000 94 94 94 223.500 223.500 915.000 915.000 915.000 233.500 Another way to switch 222 and 902MHz band is to rotate the upper dial while pressing and holding the or the key. G29T Program scan mode Program scan mode This mode is for tuning in selected channels within a set scan range. You must first register date in the program scan bank in order to perform the following operations. 40 Programscan 232.000MHz 3: 4: 915.000MHz, 232.100MHz 915.0125MHz, 222MHz band: from 216.000MHz to 249.995MHz 902MHz band: from 902.000MHz to 927.995MHz 222MHz band: from 216.000MHz to 249.995MHz 902MHz band: from 902.000MHz to 927.995MHz 223.500 Mode Program scan mode. Rotate the upper dial and select the Program scan bank. receiver receiver When transmitting with the operating frequencies set in 222MHz - 222MHz or 902MHz - 902MHz bands, [RX disabled] will appear on the display and reception will stop on the sub band temporarily. 107 Operating the full-duplex without using an optioned earphone microphone or an earphone may cause howling. Please refer P.80 “Full-Duplex” setting in the set-mode and select “prohibited” parameter to avoid this.

Users Manual

222MHz: 223.910 - 225.000MHz -1.6MHz 902MHz: 927.000 - 927.995MHz -25MHz 222.310 927.000 6-9 79 (Tone - burst) Preset Repeater Frequeneies DJ-G29T 50 50 DJ-G29T are as follows: 4 referring to the below chart. to your purposes. 222 223.500 902 223.500 223.600 223.520 223.520 223.600 4 89 in default condition. with EDS-10/14 conversion cable 223.500 223.500 total number of 223.500 89 89 102 The free utility allows you to save different memory channel data for back-up purposes. 89 89 7-7-1 7-7-2 are available up to 9 channels. and hold G29T!” 2 96 toward right. moves G29T! T 8 9

Users Manual

223.500 29 96 Press PTT to complete and go back to operate. three PowerPowerPower 223.500 Although DJ-G29T has been programmed with appropreate modulation mode according to the standard band-plans, the transmitting modulation mode can be selected manually. Available modes are NFM (narrow FM) and FM only. 223.500 Two different selective-calling tones, CTCSS (PL) and DCS, are available. the receiving signal has been set with CTCSS tone. 223.500 open. 87 223.500 915.000 915.000 223.500 90 223.500 223.600MHz 223.580MHz 223.560MHz 223.400MHz 223.420MHz 223.440MHz 223.540MHz 223.520MHz 223.500MHz 223.480MHz 223.460MHz 90 223.500 5kHz, 6.25kHz, 10kHz, 12.5kHz, 15kHz, 20kHz, 25kHz, 30kHz, 50kHz, 100kHz, 125kHz, 150kHz, 200kHz, 500kHz and 1MHz The microphone gain can be adjusted in four steps. The modulation depth can be affected by the volume at which the operator is speaking and by adjusting the distance between the operator’s mouth and the microphone. Mic Gain shallow deep 5kHz 91 91 Please program at least 1 priority-memory in advance. 223.500 range copy copy XBR(Cross Band Repeater) Mode G29T G29T Cross Band Repeater is prohibited when MAIN and SUB are set for Same band. G29T.902MHz G29T 223.500 915.000 223.500 915.000 93 and hold for a second, 223.500 “Program scan mode (P.36)” 90 is 223.500 Single Single All Press either a to stop scanning. All 223.500 223.500 9-7 or

Users Manual

G29T PTT delay Wild Dial Ring SCREEN DISPLAYRECEIVER MEMORY SCANNING KEY ASSIGNMENT POWER & BATT. SOUND TRANSMITTER REPEATER Bold Welcome slide 223.500 223.500 SCREEN DISPLAY SCREEN DISPLAY 223.500 223.500 223.500 5 seconds off off seconds secondssecondssecondssecondssecondsseconds 223.500 G29T G29T 47 “We”. 223.500 223.500 “POWER & BATT” POWER & BATT. 30 minutes 223.500 0.2 : 0.20.2 : 0.4 (unit:seconds) 0.2 : 0.80.2 : 1.20.2 : 1.8 Batt. save off 223.500 “SOUND” SOUND Lv Lv 223.500 223.500 appears band band only 223.500 “TRANSMITTER” TRANSMITTER This function allows transmitting without using the PTT by simply speaking into the microphone. When you stop speaking, the unit will return to receive. At this state, the PTT key operation is suspended. Choose a microphone to be used, or OFF to stop operating the VOX. Press FUNC to start operating the VOX. RX Disabled will appear on the display. While operating, press down the dial twice. VOX level appears. Rotate the dial to adjust the level between 1 (low gain) and 7 (sensitive).Select level 0 to temporally suspend the VOX operation. Press the dial once to resume VOX operation. Enter to the set-mode, repeat sequence, and set the VOX OFF to quit VOX operation. VOX can’t be properly operated in noisy place by picking up the noise. While operating VOX, the tone-calls, DTMF, auto-dialer and Sub-band receive are not functional. 3. 223.500 223.500 78 from “30 seconds” from “1 second” 223.500 223.500 223.500 PTT delay 7 This is to cut the squelch tail noise that the repeater retransmits at the end of receiving tone-encoded CTCSS signals. Rotate the upper dial and select “PTT delay” Rotate the lower dial and select the desired PTT delay time. “PTT delay” will be displayed as shown on the right. By rotating the dial, the PTT delay time changes as shown in the illustration. 0.30.61 unit: seconds) PTT delay 0.6 223.500 222MHz 902MHz Shift -1.6MHz -25MHz 223.910 ~ 225.000MHz 927.000 ~ 927.995MHz “REPEATER” . “REPEATER” REPEATER “ON” “OFF” . 223.500 223.500 223.500 223.500 2 seconds. 20010050 20 2s20010012014016018040608020 1 ST” 1 ST” 50 223.500 80 80 2 seconds. 223.500 80ms. 80ms. 20 2 seconds. 20 2s20010012014016018040608020 2s20010012014016018040608020 10-7-1 223.500 RECEIVER 223.500 223.500 10-7-3 DCS Operation Settings to

Users Manual

223.500 into scanning groups. 10 pairs of groups can be set, and the 10 pairs correspond to keys from to . Press the keys from to and select the group number you want to edit. By pressing the key again, “No” will be displayed, and the operation is cancelled. “MEMORY” MEMORY The used of the free - utility program makes it much easier to manage Bank - Link memories. 223.500 “SCANNING” SCANNING fail automatically. 223.500 This function can be used in the VFO mode, the Program scan mode and the Memory mode. “BUSY SCAN” scanning 223.500 223.500 223.500 5 seconds Valid BUSY turn 71 223.500 10-10-1 “KEY ASSIGNMENT” KEY ASSIGNMENT 223.500 223.500 active on 223.500 223.500 223.500 223.500 223.500 The cloning function copies data from one DJ-G29T transceiver to another DJ-G29T transceiver. Two DJ-G29T transceivers are connected by a cable and information (including memory data) from the sending unit will be copied to the receiving unit when using this function. DJ-G29T DJ-G29TDJ-G29T DJ-G29T How to enter clone mode See page 106 for details. DJ-G29T Transferring Date on both radios. By pressing the dial on Master radio, data will be transferred to the slave radio. DJ-G29T function settings also. DJ-G29T maybe available Your appars advance TX(Main band)222.000 - 224.995MHz 902.000 - 927.995MHz RX(Main/Sub band) 216.000 - 249.995MHz 902.000 - 927.995MHz 61 x 106 x 38 mm or 2.40 x 4.17 x 1.50 in. 9 1.7A/222MHz, 1.7A/902MHz 200mA/Dual, 150mA/Mono 222MHz 1.5W, 902MHz 0.7W, 222MHz 5/1/0.4W, 902MHz 2.5/1/0.4W 222MHz 4/0.8/0.3W, 902MHz 1.7/0.8/0.3W Main band 222MHz ham-radio bands -14dBμ 902MHz ham-radio bands -14dBμ Sub band 222MHz ham-radio bands -14dBμ 902MHz ham-radio bands -14dBμ Main band 51.65MHz / 450KHz Sub band 50.75MHz / 450KHz MAX)More than Mono PS0655

Attestation Statements

Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DJ-G29T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2011180 Page 20 of 58 Appendix C: FCC Attestation Letter Please refer to the following page.

Cover Letter(s)

Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DJ-G29T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2011180 Page 18 of 58 Appendix A: Agency Authorization Letter Please refer to the following page.

Cover Letter(s)

Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DJ-G29T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2011180 Page 19 of 58 Appendix B: FCC Confidentiality Request Letter Please refer to the following page.

External Photos

Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DJ-G29T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2011180 Page 34 of 58 Appendix N: External Photographs Photograph 6: Front View Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DJ-G29T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2011180 Page 35 of 58 Photograph 7: Front View with Antenna Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DJ-G29T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2011180 Page 36 of 58 Photograph 8: Back View with ID Label and Part 15 Label Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DJ-G29T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2011180 Page 37 of 58 Photograph 9: Top View Photograph 10: Bottom View with Battery Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DJ-G29T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2011180 Page 38 of 58 Photograph 11: PTT Side without Battery and with Battery Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DJ-G29T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2011180 Page 39 of 58 Photograph 12: Radio with Battery and Antenna Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DJ-G29T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2011180 Page 40 of 58 Photograph 13: Antenna Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DJ-G29T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2011180 Page 41 of 58 Photograph 14: EBP-73 Li-Ion Battery Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DJ-G29T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2011180 Page 42 of 58 Photograph 15: EDH-35 Dry Cell Case Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DJ-G29T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2011180 Page 43 of 58 Photograph 16: EDC-173 Battery Charger Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DJ-G29T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2011180 Page 44 of 58 Photograph 17: EDC-170 AC Adapter Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DJ-G29T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2011180 Page 45 of 58 Photograph 18: Dongle for Microphone/Earphone Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DJ-G29T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2011180 Page 46 of 58 Photograph 19: Earphone/Microphone

ID Label/Location Info

Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DJ-G29T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2011180 Page 25 of 58 Appendix H: Label & Location Photograph 1: ID Label and Warning Label Samples and Location on Back FCC & IC ID Label & Location FCC Pt. 15 & Cellular Warning Label & Location

Test Report

Engineering Solutions & Electromagnetic Compatibility Services 360 Herndon Pkwy | Suite 1400 | Herndon | Virginia 20170 Phone: 703.689.0368 | Fax: 703.689.2056 | www.rheintech.com FCC & IC Certification Report Model: DJ-G29T 222/902 MHz Dual Band FM Transceiver Handheld Amateur Radio FCC ID: PH3-DJG29T IC: 3070C-DJG29T Alinco Incorporated Electronics Division Yodoyabashi Dai Building 13F 4-4-9 Koraibashi, Chuo-ku Osaka 541-0043 Japan November 4, 2011 Standards Referenced for this Report Part 2: 2010 Frequency Allocations and Radio Treaty Matters; General Rules and Regulations Part 15.121: 2010 Radio Frequency Devices; Scanning Receivers and Frequency Converters Used with Scanning Receivers ANSI C63.4-2003 Standard Format Measurement/Technical Report Personal Computer and Peripherals RSS-215 Issue 2 Analogue Scanner Receivers Frequency Range (MHz) Output Power (W) Frequency Tolerance Emission Designators 216-249.995 N/A N/A 16K0F3E 902-927.995 N/A N/A 16K0F3E Report Prepared By: Test Engineer: Jon Wilson Administrative Writer: Jon Wilson Document Number: 2011180 This report may not be reproduced, except in full, without the full written approval of Rhein Tech Laboratories, Inc. and Alinco Inc. The test results relate only to the item tested. These tests are accredited and meet the requirements of ISO/IEC 17025 as verified by ANSI-ASQ National Accreditation Board/ACLASS. Refer to certificate and scope of accreditation AT-1445. Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DJ-G29T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2011180 Page 2 of 58 Table of Contents 1 General Information ............................................................................................................................ 5 1.1 Modifications ................................................................................................................................... 5 1.2 Related Submittal(s)/Grant(s) ......................................................................................................... 5 1.3 Test Methodology ............................................................................................................................ 5 1.4 Test Facility ..................................................................................................................................... 5 2 System Test Configuration ................................................................................................................ 6 2.1 Justification ..................................................................................................................................... 6 2.2 Exercising the EUT ......................................................................................................................... 6 2.3 Test System Details ........................................................................................................................ 6 2.4 Configuration of Tested System ...................................................................................................... 7 3 AC Conducted Emissions - FCC Rules and Regulations Part 15 §15.107(b): Conducted Limits .............................................................................................................................................................. 8 3.1 Site and Test Description ................................................................................................................ 8 3.2 Test Limits ....................................................................................................................................... 8 3.3 Conducted Emissions Test Data ..................................................................................................... 9 4 Radiated Emissions – FCC Rules and Regulations Part 15 §15.109(a): Radiated Emissions Limits; RSS-215 §7 - Receiver Spurious Emissions ............................................................................. 11 4.1 Test Methodology for Radiated Emissions Measurements .......................................................... 11 4.2 Radiated Emissions Data .............................................................................................................. 12 5 FCC Rules and Regulations Part 15 §15.121(b) - 38 dB Rejection Test ...................................... 15 5.1 38 dB Rejection Test Data for Base Band (869.04-893.970 MHz) ............................................... 16 5.2 38 dB Rejection Test Data for Mobile Band (824.04-848.970 MHz) ............................................ 16 6 Conclusion ........................................................................................................................................ 17 Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DJ-G29T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2011180 Page 3 of 58 Table Index Table 2-1: Equipment Under Test (EUT) ................................................................................................. 6 Table 2-2: Auxiliary Equipment ................................................................................................................ 6 Table 3-1: Equipment Used for Testing Conducted Emissions ............................................................. 10 Table 4-1: Radiated Emissions – Mode RX Ch 216 MHz ..................................................................... 12 Table 4-2: Radiated Emissions – Mode RX Ch 232.995 MHz .............................................................. 12 Table 4-3: Radiated Emissions – Mode RX Ch 249.995 MHz .............................................................. 12 Table 4-4: Radiated Emissions – Mode RX Ch 902 MHz ..................................................................... 13 Table 4-5: Radiated Emissions – Mode RX Ch 915 MHz ..........................…

Text truncated - open the document above for the full version.

Test Setup Photos

Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DJ-G29T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2011180 Page 30 of 58 Appendix M: Test Configuration Photographs Photograph 2: Radiated Emissions Test Configuration (Front View) Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DJ-G29T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2011180 Page 31 of 58 Photograph 3: Radiated Emissions Test Configuration (Rear View) Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DJ-G29T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2011180 Page 32 of 58 Photograph 4: Conducted AC Emissions Test Configuration (Front View) Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DJ-G29T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2011180 Page 33 of 58 Photograph 5: Conducted AC Emissions Test Configuration (Rear View)

Contact Information

Applicant

Kazuhiro Kusuhara(General Manager, Production, Electronics Div.)
[email protected]06-7636-2360Fax: 06-6208-3801

Technical Contact

Rhein Tech LabsRick McMurray
[email protected]703-689-0459

360 Herndon Parkway · Herndon, Virginia · United States

Test Firm

Rhein Tech Laboratories, Inc.Richard McMurray
[email protected]703-689-0368Fax: 703-689-2056

Technical Specifications

#Rule PartsFrequency RangePower Output
215B902 MHz - 927.995 MHz-
Confidentiality
Long Term

Other Applications from Alinco Incorporated, Electronics Division

PH3-DR-B185TMKII

VHF FM TRANSCEIVER

Apr 15, 2026

Equipment Class

CSR - Scanning Receiver
VHF/UHF DUAL BAND FM TRANSCEIVER - FCC ID PH3-DJ-W70HT - Alinco Incorporated, Electronics Division
PH3-DJ-W70HT

VHF/UHF DUAL BAND FM TRANSCEIVER

Jun 06, 2025

Equipment Class

JAV - Other Non-Digital SDoC Devices
UHF FM TRANSCEIVER - FCC ID PH3DJ-G46T - Alinco Incorporated, Electronics Division
PH3DJ-G46T

UHF FM TRANSCEIVER

Nov 19, 2023

Equipment Class

TNF - Licensed Non-Broadcast Transmitter Held to Face
VHF FM TRANSCEIVER - FCC ID PH3DR-CS25 - Alinco Incorporated, Electronics Division
PH3DR-CS25

VHF FM TRANSCEIVER

Dec 14, 2022

Equipment Class

CSR - Scanning Receiver
DMR VHF/UHF MOBILE TRANSCEIVER - FCC ID PH3DR-MD520T - Alinco Incorporated, Electronics Division
PH3DR-MD520T

DMR VHF/UHF MOBILE TRANSCEIVER

May 31, 2021

Equipment Class