FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

ยฉ 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Alinco Incorporated, Electronics Division/
  3. PH3DJ-V47T

PH3DJ-V47TDJ-V47T VHF Scanning Receiver

Alinco Incorporated, Electronics Division
DJ-V47T VHF Scanning Receiver - FCC ID PH3DJ-V47T - Alinco Incorporated, Electronics Division
Click to zoom

Application Details

Equipment Class
CSR - Scanning Receiver
Date of Grant
Oct 16, 2006
Application Purpose
Original Equipment
Date of Application
Oct 16, 2006
Equipment Note
DJ-V47T VHF Scanning Receiver
Frequency Range
400.00000000 - 479.99500000
Company
Alinco Incorporated, Electronics Division
Country
Japan

Documents & Files

Select a file to view

Users Manual

โ†—

Attestation Statements

โ†—

Cover Letter(s)

โ†—
โ†—
โ†—

External Photos

โ†—

ID Label/Location Info

Test Report

โ†—

Test Setup Photos

โ†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DJ-V47T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2006162 Page 25 of 45 Appendix J: Manual Please see the following pages.

Attestation Statements

Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DJ-V47T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2006162 Page 17 of 45 Appendix C: FCC Attestation Letter Please refer to the following page.

Cover Letter(s)

Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DJ-V47T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2006162 Page 15 of 45 Appendix A: Agency Authorization Letter Please refer to the following page.

Cover Letter(s)

Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DJ-V47T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2006162 Page 16 of 45 Appendix B: Confidentiality Request Letter Please refer to the following page.

Cover Letter(s)

Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DJ-V47T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2006162 Page 17 of 45 Appendix C: FCC Attestation Letter Please refer to the following page.

External Photos

Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DJ-V47T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2006162 Page 31 of 45 Appendix L: External Photographs Photograph 8: Front View Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DJ-V47T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2006162 Page 32 of 45 Photograph 9: Back View Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DJ-V47T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2006162 Page 33 of 45 Photograph 10: Right Side View Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DJ-V47T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2006162 Page 34 of 45 Photograph 11: Left Side View Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DJ-V47T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2006162 Page 35 of 45 Photograph 12: Top View Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DJ-V47T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2006162 Page 36 of 45 Photograph 13: Bottom View Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DJ-V47T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2006162 Page 37 of 45 Photograph 14: EDC-146 AC Adapter Top View Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DJ-V47T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2006162 Page 38 of 45 Photograph 15: EBP-63, EBP-65, EBP-66 Battery Labels Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DJ-V47T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2006162 Page 39 of 45 Photograph 16: EDH-34, EBP-64 Battery Labels Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DJ-V47T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2006162 Page 40 of 45 Photograph 17: Antenna

Test Report

Engineering and Testing for EMC and Safety Compliance 360 Herndon Parkway, Suite 1400 Herndon, VA 20170 Tel: 703-689-0368 Fax: 703-689-2056 CERTIFICATION APPLICATION TEST REPORT VHF FM TRANSCEIVER FCC ID: PH3DJ-V47T IC: 3070C-DJV47T MODEL: DJ-V47T Alinco Incorporated Electronics Division Shin-Dai Building 9F 2-6, 1-Chome, Dojimahama, Kita-ku Osaka 530-0004 Japan October 10, 2006 Standards Referenced for this Report Part 2: 2006 Frequency Allocations and Radio Treaty Matters; General Rules and Regulations Part 15.121: 2006 Radio Frequency Devices; Scanning Receivers and Frequency Converters Used with Scanning Receivers ANSI C63.4-2003 Standard Format Measurement/Technical Report Personal Computer and Peripherals RSS-215; Issue 1 (Provisional) Analogue Scanner Receivers Frequency Range (MHz) Output Power (W) Frequency Tolerance Emission Designator 400-479.995 N/A N/A N/A REPORT PREPARED BY: Test Engineer:Daniel Baltzell Administrative Writer:Daniel Baltzell Rhein Tech Laboratories, Inc. Document Number: 2006162 This report may not be reproduced, except in full, without the full written approval of Rhein Tech Laboratories, Inc. The test results relate only to the EUT tested. Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DJ-V47T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2006162 Page 2 of 45 Table of Contents 1 General Information ........................................................................................................................... 4 1.1 Modifications.................................................................................................................................................. 4 1.2 Related Submittal(s)/Grant(s) ........................................................................................................................ 4 1.3 Test Methodology .......................................................................................................................................... 4 1.4 Test Facility ................................................................................................................................................... 4 2 System Test Configuration................................................................................................................ 5 2.1 Justification .................................................................................................................................................... 5 2.2 Exercising the EUT ........................................................................................................................................ 5 2.3 Test System Details....................................................................................................................................... 5 2.4 Configuration of Tested System .................................................................................................................... 7 3 AC Conducted Emissions - FCC Rules and Regulations Part 15 ยง15.107(b): Conducted Limits8 3.1 Site and Test Description............................................................................................................................... 8 3.2 Test Limits ..................................................................................................................................................... 8 3.3 Conducted Emissions Test Data ................................................................................................................... 9 4 Radiated Emissions โ€“ FCC Rules and Regulations Part 15 ยง15.109(a): Radiated Emissions Limits; RSS-215 Section 7 - Receiver Spurious Emissions ............................................................ 10 4.1 Test Methodology for Radiated Emissions Measurements .......................................................................... 10 4.2 Radiated Emissions Data ............................................................................................................................ 11 5 FCC Rules and Regulations Part 15 ยง15.121(b) - 38 dB Rejection Test ..................................... 12 5.1 38 dB Rejection Test Data for Base Band (869.040-893.970 MHz) ............................................................ 13 5.2 38 dB Rejection Test Data for Mobile Band (824.040-848.970 MHz) .......................................................... 13 6 Conclusion ........................................................................................................................................ 14 Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DJ-V47T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2006162 Page 3 of 45 Table Index Table 2-1: Equipment Under Test (EUT)............................................................................................................... 6 Table 3-1: Conducted Emissions Test Data โ€“ Mode RX, Neutral Side Line 1, 440 MHz ...................................... 9 Table 3-2: Conducted Emissions Test Data โ€“ Mode RX, Hot Side Line 2, 440 MHz ............................................ 9 Table 3-3: Equipment Used for Testing................................................................................................................. 9 Table 4-1: Radiated Emissions โ€“ Mode RX......................................................................................................... 11 Table 4-2: Equipment Used for Testing............................................................................................................... 11 Table 5-1: 38 dB Rejection {Frequency Injected: 869.040 MHz} (Cellular Band) ............................................... 13 Table 5-2: 38 dB Rejection {Frequency Injected: 881.500 MHz} (Cellular Band) ............................................... 13 Table 5-3: 38 dB Rejection {Frequency Injected: 893.970 MHz} (Cellular Band) ......โ€ฆ

Text truncated - open the document above for the full version.

Test Setup Photos

Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DJ-V47T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2006162 Page 26 of 45 Appendix K: Test Configuration Photographs Photograph 3: Radiated Emissions Test Configuration (Front View) Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DJ-V47T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2006162 Page 27 of 45 Photograph 4: Radiated Emissions Test Configuration (Rear View) Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DJ-V47T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2006162 Page 28 of 45 Photograph 5: 38 dB Rejection Test Configuration Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DJ-V47T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2006162 Page 29 of 45 Photograph 6: Conducted AC Emissions Test Configuration (Front View) Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DJ-V47T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2006162 Page 30 of 45 Photograph 7: Conducted AC Emissions Test Configuration (Rear View)

Contact Information

Applicant

Kazuhiro Kusuhara(General Manager, Production, Electronics Div.)
[email protected]06-7636-2360Fax: 06-6208-3801

Technical Contact

Rhein TechRichard McMurray
[email protected]703-689-0368

360 Herndon Parkway Suite 1400 ยท Herndon, Virginia ยท United States

Test Firm

Rhein Tech Laboratories, Inc.Rick McMurray
[email protected]703-689-0368Fax: 703-689-2056

Technical Specifications

#Rule PartsFrequency RangePower Output
115B400 MHz - 479.995 MHz-
Confidentiality
Long Term

Other Applications from Alinco Incorporated, Electronics Division

PH3-DR-B185TMKII

VHF FM TRANSCEIVER

Apr 15, 2026

Equipment Class

CSR - Scanning Receiver
VHF/UHF DUAL BAND FM TRANSCEIVER - FCC ID PH3-DJ-W70HT - Alinco Incorporated, Electronics Division
PH3-DJ-W70HT

VHF/UHF DUAL BAND FM TRANSCEIVER

Jun 06, 2025

Equipment Class

JAV - Other Non-Digital SDoC Devices
UHF FM TRANSCEIVER - FCC ID PH3DJ-G46T - Alinco Incorporated, Electronics Division
PH3DJ-G46T

UHF FM TRANSCEIVER

Nov 19, 2023

Equipment Class

TNF - Licensed Non-Broadcast Transmitter Held to Face
VHF FM TRANSCEIVER - FCC ID PH3DR-CS25 - Alinco Incorporated, Electronics Division
PH3DR-CS25

VHF FM TRANSCEIVER

Dec 14, 2022

Equipment Class

CSR - Scanning Receiver
DMR VHF/UHF MOBILE TRANSCEIVER - FCC ID PH3DR-MD520T - Alinco Incorporated, Electronics Division
PH3DR-MD520T

DMR VHF/UHF MOBILE TRANSCEIVER

May 31, 2021

Equipment Class

CSR - Scanning Receiver