Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DR-06T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2007223 Page 26 of 42 Appendix J: Manual Please see the following pages. 40-70
Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DR-06T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2007223 Page 18 of 42 Appendix C: FCC Attestation Letter Please refer to the following page.
Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DR-06T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2007223 Page 16 of 42 Appendix A: Agency Authorization Letter Please refer to the following page.
Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DR-06T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2007223 Page 17 of 42 Appendix B: Confidentiality Request Letter Please refer to the following page.
Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DR-06T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2007223 Page 32 of 42 Appendix L: External Photographs Photograph 8: Front View Photograph 9: Back View Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DR-06T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2007223 Page 33 of 42 Photograph 10: Right Side View Photograph 11: Left Side View Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DR-06T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2007223 Page 34 of 42 Photograph 12: Top View Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DR-06T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2007223 Page 35 of 42 Photograph 13: Bottom View
Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DR-06T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2007223 Page 21 of 42 Appendix F: Label & Location FCC & IC ID Label Location Warning Label Location Photograph 1: FCC/IC ID and Warning Label Locations Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DR-06T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2007223 Page 22 of 42 Photograph 2: FCC/IC ID Label Sample
Engineering and Testing for EMC and Safety Compliance Accredited under NVLAP Lab Code 200061-0 360 Herndon Parkway, Suite 1400 Herndon, VA 20170 Tel: 703-689-0368 Fax: 703-689-2056 C C e e r r t t i i f f i i c c a a t t i i o o n n R R e e p p o o r r t t VHF FM Transceiver Model: DR-06T FCC ID: PH3DR-06T IC: 3070C-DR06T Alinco Incorporated Electronics Division Shin-Dai Building 9F 2-6, 1-Chome, Dojimahama, Kita-ku Osaka 530-0004 Japan August 8, 2007 Standards Referenced for this Report Part 2: 2006 Frequency Allocations and Radio Treaty Matters; General Rules and Regulations Part 15.121: 2006 Radio Frequency Devices; Scanning Receivers and Frequency Converters Used with Scanning Receivers ANSI C63.4-2003 Standard Format Measurement/Technical Report Personal Computer and Peripherals RSS-215; Issue 1 (Provisional) Analogue Scanner Receivers Frequency Range (MHz) Output Power (W) Frequency Tolerance Emission Designator 40 - 69.995 N/A N/A N/A REPORT PREPARED BY: Test Engineer:Daniel Baltzell Administrative Writer:Daniel Baltzell Rhein Tech Laboratories, Inc. Document Number: 2007223 This report may not be reproduced, except in full, without the full written approval of Rhein Tech Laboratories, Inc. The test results relate only to the EUT tested. This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DR-06T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2007223 Page 2 of 42 Table of Contents 1 General Information............................................................................................................................4 1.1 Modifications.................................................................................................................................................. 4 1.2 Related Submittal(s)/Grant(s) ........................................................................................................................ 4 1.3 Test Methodology .......................................................................................................................................... 4 1.4 Test Facility.................................................................................................................................................... 4 2 System Test Configuration ................................................................................................................5 2.1 Justification .................................................................................................................................................... 5 2.2 Exercising the EUT ........................................................................................................................................ 5 2.3 Test System Details ....................................................................................................................................... 5 2.4 Configuration of Tested System..................................................................................................................... 7 3 AC Conducted Emissions - FCC Rules and Regulations Part 15 ยง15.107(b): Conducted Limits ..............................................................................................................................................................8 3.1 Site and Test Description............................................................................................................................... 8 3.2 Test Limits ..................................................................................................................................................... 8 3.3 Conducted Emissions Test Data.................................................................................................................... 9 4 Radiated Emissions โ FCC Rules and Regulations Part 15 ยง15.109(a): Radiated Emissions Limits; RSS-215 Section 7 - Receiver Spurious Emissions .........................................................10 4.1 Test Methodology for Radiated Emissions Measurements .......................................................................... 10 4.2 Radiated Emissions Data............................................................................................................................. 11 5 FCC Rules and Regulations Part 15 ยง15.121(b) - 38 dB Rejection Test ......................................13 5.1 38 dB Rejection Test Data for Base Band (869.040-893.970 MHz)............................................................. 14 5.2 38 dB Rejection Test Data for Mobile Band (824.040-848.970 MHz) .......................................................... 14 6 Conclusion ........................................................................................................................................15 Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DR-06T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2007223 Page 3 of 42 Table Index Table 2-1: Equipment Under Test (EUT) ............................................................................................................... 6 Table 2-2: Support Equipment Used in Testing..................................................................................................... 6 Table 3-1: Conducted Emissions Test Data โ Mode RX, Neutral Side Line .......................................................... 9 Table 3-2: Conducted Emissions Test Data โ Mode RX, Hot Side Line ................................................................ 9 Table 3-3: Equipment Used for Testing ................................................................................................................. 9 Table 4-1: Radiated Emissions โ Mode RX...............................................โฆ
Text truncated - open the document above for the full version.
Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DR-06T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2007223 Page 27 of 42 Appendix K: Test Configuration Photographs Photograph 3: Radiated Emissions Test Configuration (Front View) Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DR-06T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2007223 Page 28 of 42 Photograph 4: Radiated Emissions Test Configuration (Rear View) Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DR-06T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2007223 Page 29 of 42 Photograph 5: 38 dB Rejection Test Configuration Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DR-06T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2007223 Page 30 of 42 Photograph 6: Conducted AC Emissions Test Configuration (Front View) Rhein Tech Laboratories, Inc. Client: Alinco, Inc. 360 Herndon Parkway Model: DR-06T Suite 1400 Standards: FCC 15.121 Herndon, VA 20170 & IC RSS-215 http://www.rheintech.com Report: 2007223 Page 31 of 42 Photograph 7: Conducted AC Emissions Test Configuration (Rear View)
360 Herndon Parkway ยท Herndon, Virginia ยท United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | 40 MHz - 69.995 MHz | - |
VHF FM TRANSCEIVER
Equipment Class
CSR - Scanning Receiver
VHF/UHF DUAL BAND FM TRANSCEIVER
Equipment Class
JAV - Other Non-Digital SDoC Devices
UHF FM TRANSCEIVER
Equipment Class
TNF - Licensed Non-Broadcast Transmitter Held to Face
VHF FM TRANSCEIVER
Equipment Class
CSR - Scanning Receiver
DMR VHF/UHF MOBILE TRANSCEIVER
Equipment Class
CSR - Scanning Receiver