Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
FRONT VIEW Pr imar y Fun ction s 1 Power turn s ON / OFF wh en ever power suppl y s witch is pr essed. 2 Volume kn ob Adjusts th e volume level. 3 Dial Chan ges th e fr equen cy, memor y ch ann el an d 4 FUNC/SET Sets in th e fun ction mode to access ever y fun ction 5 V/M/MW Swit ch es between VFO mode an d memor y mode. 6 MHZ/S HIFT Chan ges th e fr equen cy in 1 MHz steps. 7 TSDCS/LOCK Sets th e ton e squelch an d DCS settin g. 8 CALL/ H/L Swit ch es to CALL mod e. 9 SQL/D Sets th e squelch level 10 DATA Ter minal Used in clon e an d burglar alar m fun ction s. 11 TX Light in dicator Ligh ts on dur in g tr an smission . 12 Mic. Conn ector Con n ects th e attach ed micr oph one. Fun ction s wh ich can be activated wh ile F appear s, after pr essin g th e FUCN Key. 4 FUNC/SET Con fir ms selection of oth er fun ction s an d exits th e fun ction mode. 5 V/M/MW Wr ite in to memor y ch ann el. 6 MHZ/S HIFT Sets th e shift settin g an d th e offs et fr equen cy. 7 TSDCS/LOCK Sets th e key lock fun ction . 8 CALL/ H/L Swit ch es between HI, MID, and LOW power tr an smission . 9 SQL/D Acces ses th e 9600 bps packet an d commun ication mode. Fun ction s that can be activated wh ile pr essin g th e FUNC Key 1 PWR Reset all th e settin g data 5 V/M/MW Erase th e memor y. 6 MHZ/S HIFT Swit ch es to wid e / n arr ow mod e r eception . 7 TSDCS/LOCK Sets th e auto dialer. 8 CALL/ H/L Acces ses th e clon e fun ction mode. 9 SQL/D Acces ses th e power supply voltage in dication mode. Fun ction s that r equir es con tin uous pr essin g to be activated. 4 FUNC/SET Wh en pr ess with in 2 secon ds, it access es th e set mode 9 SQL/D Wh en pr ess with in 1 secon d, th e mon itor fun ction wor ks on . 10 7 8 9 3 1 2 11 45612 06 DISPLAY 1 SQL Appears when s ett i ng t he sq uel ch l evel. 2 M Appears when i n me mor y mode 3 88 Indi cates t he me mor y no. i n me mor y mode 4 .Deci mal poi nt Appears when s ett i ng t he b urglar alarm functi on. 5 .Deci mal poi nt Appears when s ett i ng t he deci mal poi nt of s ki p l evel. 6 .Deci mal poi nt Indi cates t he deci mal poi nt of freq uency and t he sca nni ng move ment. 7 8888888 Indi cates t he freq uency a nd memor y na me 8 BUSY Appears when si gnal is bei ng recei ve. 9 S- met er Indi cates t he si gnal s trengt h level of trans miss i on / recepti on. 10 * Appears when i n 9600 b ps packet mode / communi cati on mode. 11 * Appears when s ett i ng t he key l ock. 12 DCS Appears when s ett i ng t he DCS. 13 TSQ Appears when s ett i ng t he t one sq uel ch 14 +- Appears when s ett i ng t he s hi ft. 15 A - 16 Nar Appears when i n narrow ba nd recept ion mode 17 Lo Appears when tra ns miss i on power is s et to LOW. 18 Mi Appears when tra ns miss i on power is s et to MID 19 F Appears when FUNC Key is pres sed. 10 11121314 151617 1819 2 34 5 78 9 1 6 M IC PTT DOWN GND M IC GND Remot e con tr ol DC 5V UP MICROPHONE DR-06T Option No. Key 1 UP key 2 DOWN key 3 PTT k ey 4 DTM F keys 5 DTM F ON/OFF s witch / Key Light ON/OFF s witch 6 UP/DOWN lockout s witch 7 M IC M ic. Connect or Diagram (While l ooking in th e fr ont vi ew of the conn ect or) OFF LOCK DTMF OFF LOCK OFF 7 6 1 2 3 6 5 4 7 3 1 2 4 1 2 35 6 7 8 REAR VIEW 1 Antenna Connect or Connecti on for 50 ohm coaxial cable and antenna. 2 DSUB9 Connect or Ter mi nal where market a vailable TNC is bei ng connected duri ng pa cket use. 3 External Spea ker Ter mi nal Ter mi nal for mar ket a vailable ext ernal s peaker. 4 External Input Power Suppl y Ter mi nal Ter mi nal for connecti ng opt i onal EDC-37 whi ch works as an AC power s uppl y when s wit ch on. 5 DC Power Suppl y Cable Please con n ect it in a 12V DC power suppl y or DC batter y. 14 5 3 2 SAFETY TRAINING INFORMATION Your Alinco Incorporated, Electronics Division radio generators RF electromagnetic energy during transmit mode. This radio is designed for and classified as “Occupational Use Only”, meaning it must be used only during the course of employment by individuals aware of the hazards, and the ways to minimize such hazards. This radio is NOT intended for use by the “General Population” in an uncontrolled environment. This radio has been tested and complies with the FCC RF exposure limits for “Occupational Use Only”. Inaddition , your Alinco Incorporated, Electronics Division radio complies with the following Standards and Guidelines with regard to RF energy and electromagnetic energy levels and evaluation of such levels for exposure to humans: � FCC OET Bulletin 65 Edition 97-01 Supplement C, Evaluating Compliance with FCC Guidelines for Human Exposure to Radio Frequency Electromagnetic Fields. � American National Standards Institute (C95.1-1992), IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. � American National Standards Institute (C95.3-1992), IEEE Recommended Practice for the Measurement of Potentially Hazardous Electromagnetic Fields– RF and Microwave. � The following accessories are authorized for use with this product. Use of accessories other than those (listed in the instruction) specified may result in RF exposure levels exceed the FCC requirements for wireless RF exposure. To ensure you’re your expose to RF electromagnetic energy is within the FCC allowable limits for occupational use, always adhere to the following guidelines: � DO NOT operate the radio without a proper antenna attached, as this may damaged the radio and may also cause you to exceed FCC RF exposure limits. A proper antenna is the antenna supplied with this radio by the manufacturer or antenna specifically authorized by the manufacturer for use with this radio. � DO NOT transmits for more than 50% of total radio use time (“50%duty cycle”). Transmitting more than 50% of the time can cause FCC RF exposure compliance requirements to be exceeded. The radio is transmitting when the “TX indicator” lights red. You can cause the radio to transmit by pressing the “PTT” switch. The information liste…
Text truncated - open the document above for the full version.
5/19/2020 MET Laboratories, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR FCC ID: PH3DR-06TA To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the (1) schematic diagrams, (2) detailed block diagrams, (3) detailed operational descriptions, (4) parts lists. (5)Tune-up Procedure required to be submitted with this application be permanently withheld from public review. Please contact me if there is any information you may need. Sincerely, Signature Kazuhiro Kusuhara Alinco Incorporated, Electronics Division
5/19/2020 Eurofins MET Labs 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize Attestation of Global Compliance (Shenzhen) Co., Ltd to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Signature Kazuhiro Kusuhara Alinco Incorporated, Electronics Division
Date: 19 May 2020 Federal Communication Commission Authorization and Evaluation Division FCC ID: PH3DR-06TA Subject: Declaration of compliance to the requirements of §15.121 We declare that, this scanning receiver is incapable of operating (tuning), or readily being altered by the users to operate, within the frequency bands allocated to the Cellular Radiotelephone Service in part 22 of this chapter (cellular telephone bands). This device will not be able to receive transmissions in the cellular telephone bands by means of clipping the leads of, or installing, a simple component such as a diode, resistor or jumper wire; replacing a plug-in semiconductor chip; or programming a semiconductor chip using special access codes or an external device, such as a personal computer. This device is also incapable of converting digital cellular communication transmissions to analog voice audio. This device is designed so that the tuning, control and filtering circuitry is inaccessible. Any attempts to modify the equipment to receive transmissions from the Cellular Radiotelephone Service will render the receiver inoperable. This scanning receiver rejects any signals from the Cellular Radiotelephone Service frequency bands that are 38 dB or lower based upon a 12 dB SINAD measurement. We are aware that the modification of this device to receive transmissions from Cellular Radiotelephone Service frequency bands will be considered to constitute manufacture of such equipment. This includes any individual, individuals, entity or organization that modifies one or more scanners. Any modification to receive transmissions from the Cellular Radiotelephone Service frequency bands voids the certification of the scanning receiver, regardless of the date of manufacture of the original unit. If you have any questions, please feel free to contact me. Thank you. Sincerely, Signatory Signature Kazuhiro Kusuhara Alinco Incorporated, Electronics Division
External Photos WHOLE VIEW OF EUT Part I TOP VIEW OF EUT Antenna Port BOTTOM VIEW OF EUT FRONT VIEW OF EUT BACK VIEW OF EUT LEFT VIEW OF EUT RIGHT VIEW OF EUT Hand microphone TOP VIEW OF EUT BOTTOM VIEW OF EUT FRONT VIEW OF EUT BACK VIEW OF EUT LEFT VIEW OF EUT RIGHT VIEW OF EUT
FCC ID Label Location FCC ID: PH3DR-06TA MODIFICATION OF THIS DEVICE TO RECEIVE CELLULAR RADIOTELEPHONE SERVICE SIGNALS IS PROHIBITED UNDER FCC RULES AND FEDERAL LAW.
Internal Photos OPEN VIEW OF EUT(FIGURE 1) OPEN VIEW OF EUT(FIGURE 2) OPEN VIEW OF EUT(FIGURE 3) INTERNAL VIEW OF EUT(FIGURE 1) INTERNAL VIEW OF EUT(FIGURE 2) INTERNAL VIEW OF EUT(FIGURE 3) INTERNAL VIEW OF EUT(FIGURE 4) INTERNAL VIEW OF EUT(FIGURE 5) INTERNAL VIEW OF EUT(FIGURE 6) INTERNAL VIEW OF EUT(FIGURE 7) INTERNAL VIEW OF EUT(FIGURE 8) INTERNAL VIEW OF EUT(FIGURE 9) INTERNAL VIEW OF EUT(FIGURE 10) INTERNAL VIEW OF EUT(FIGURE 11) INTERNAL VIEW OF EUT(FIGURE 12) INTERNAL VIEW OF EUT(FIGURE 13) INTERNAL VIEW OF EUT(FIGURE 14) Hand microphone OPEN VIEW OF EUT(FIGURE 1) OPEN VIEW OF EUT(FIGURE 2) INTERNAL VIEW OF EUT(FIGURE 1) INTERNAL VIEW OF EUT(FIGURE 2) INTERNAL VIEW OF EUT(FIGURE 3)
RF EXPOSURE EVALUATION 1. TEST RESULT CERTIFICATION Applicant Alinco Incorporated, Electronics Division Address Yodoyabashi Dai Building 13F,4-4-9 Korasibashi, Chuo-ku Osaka,541-0043 Japan manufacturer Alinco Incorporated, Electronics Division Address Yodoyabashi Dai Building 13F,4-4-9 Korasibashi, Chuo-ku Osaka,541-0043 Japan Factory Alinco Incorporated, Electronics Division Address Yodoyabashi Dai Building 13F,4-4-9 Korasibashi, Chuo-ku Osaka,541-0043 Japan Product Designation: VHF FM MOBILE TRANSCEIVER Brand Name: ALINCO Test Model: DR-06TA FCC ID: PH3DR-06TA Date of Test: Apr. 02, 2020~Apr. 30, 2020 2. TECHNICAL INFORMATION A major technical description of EUT is described as following: Operation Frequency 44.950 MHz to 47.930 MHz Modulation FM Antenna Designation Detachable Antenna type External antenna Output power 50W Antenna gain 0dBi Power Supply DC 13.8V 3. RF EXPOSURE MEASUREMENT 3.1 INTRODUCTION Human exposure to RF emissions from mobile devices (47 CFR §2.1091) may be evaluated based on the MPE limits adopted by the FCC for electric and magnetic field strength and/or power density, as appropriate, since exposures are assumed to occur at distances of 20 cm or more from persons. The 1992 ANSI/IEEE standard (See Listed limit table) specifies a minimum separation distance of 20 cm for performing reliable field measurements to determine adherence to MPE limits. If the minimum separation distance between a transmitter and nearby persons is more than 20 cm under normal operating conditions, compliance with MPE limits may be determined at such distance from the transmitter. When applicable, operation instructions and prominent warning labels may be used to alert the exposed persons to maintain a specified distance from the transmitter or to limit their exposure durations and usage conditions to ensure compliance. 3.2 FCC LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) LIMITS FOR GENERAL POPULATION / UNCONTROLLED EXPOSURE Frequency Range (MHz) E-field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/cm 2 ) Averaging Time |E| 2 , |H| 2 or S (Minutes) 0.3 -- 1.34 614 1.63 (100)* 30 1.34 -- 30 824/f 2.19/f (180/f 2 )* 30 30 -- 300 27.5 0.073 0.2 30 300 -- 1500 -- -- f/1500 30 1500 -- 100,000 -- -- 1.0 30 *Note: 1. f= Frequency in MHz * Plane-wave Equivalent Power Density 2.The averaging time for General Population/Uncontrolled exposure to fixed transmitters is not applicable for mobile and portable transmitters. See 47 CFR §§2.1091 and 2.1093 on source-based time-averaging requirement for mobile and portable transmitters. 4. CLASSIFICATION OF THE ASSESSMENT METHODS According to user manual, The antenna of the product, under normal use condition is at least 139.7 cm away from the body of the user. Warning statement to the user for keeping at least 139.7 cm separation distance and the prohibition of operating to a person has been printed on the user’s manual. So, this product under normal use is located on electromagnetic far field between the human body. S=PG/4πR² Where: S=power density P=power input to antenna G=power gain of the antenna in the direction of interest relative to an isotropic radiator R=distance to the center of radiation of the antenna 5. EUT OPERATION CONDITION Make the EUT to transmit at Bottom channel, Middle channel and Top channel individually. 6. TEST RESULTS Note: report the worst result in this part Antenna Gain=0 dBi (Numeric 1), π=3.141, Duty cycle=50% Frequency Output Power Output Power Correct Power Power Density Power Density Limit Result MHz dBm mW mW mW/cm 2 mW/cm 2 Pass/Fail 47.910 46.90 48980 24490 0.1998 0.2 Pass Note: 1.The output power is refer to AGC00725200401FE10. 2.Correct Power=Output Power*Duty cycle. 3.According to the user manual, the minimum separate distance which used for MPE calculate is 139.7cm.
Page 1 of 51 Report No.: AGC00725200401FE10 FCC ID : PH3DR-06TA PRODUCT DESIGNATION : VHF FM MOBILE TRANSCEIVER BRAND NAME : ALINCO MODEL NAME : DR-06TA APPLICANT : Alinco Incorporated, Electronics Division DATE OF ISSUE : Apr. 30, 2020 STANDARD(S) : FCC Part 90 Rules REPORT VERSION : V 1.0 Attestation of Global Compliance (Shenzhen) Co., Ltd CAUTION: This report shall not be reproduced except in full without the written permission of the test laboratory and shall not be quoted out of context. FCC Part 90 Rules Test Report Report No.: AGC00725200401FE10 Page 2 of 51 Report Revise Record Report Version Revise Time Issued Date Valid Version Notes V1.0 / Apr. 30, 2020 Valid Initial Release Report No.: AGC00725200401FE10 Page 3 of 51 TABLE OF CONTENTS 1. VERIFICATION OF COMPLIANCE ......................................................................................................... 5 2. GENERAL INFORMATION ..................................................................................................................... 6 2.1PRODUCT DESCRIPTION ............................................................................................................. 6 2.3 TEST METHODOLOGY ................................................................................................................. 9 2.4 TEST FACILITY ............................................................................................................................. 9 2.5 SPECIAL ACCESSORIES ............................................................................................................. 9 2.6 EQUIPMENT MODIFICATIONS ..................................................................................................... 9 3. SYSTEM TEST CONFIGURATION ....................................................................................................... 10 3.1EUT CONFIGURATION ................................................................................................................ 10 3.2 EUT EXERCISE ........................................................................................................................... 10 3.3 GENERAL TECHNICAL REQUIREMENTS ................................................................................. 10 3.4CONFIGURATION OF TESTED SYSTEM ..................................................................................... 11 4. SUMMARY OF TEST RESULTS ........................................................................................................... 12 5. DESCRIPTION OF TEST MODES ........................................................................................................ 14 6. FREQUENCY TOLERANCE ................................................................................................................. 15 6.1 PROVISIONS APPLICABLE ........................................................................................................ 15 6.2 MEASUREMENT PROCEDURE ................................................................................................. 15 6.3 TEST SETUP BLOCK DIAGRAM ................................................................................................ 16 6.4 TEST RESULTS ........................................................................................................................... 17 7.EMISSION BANDWIDTH ....................................................................................................................... 18 7.1 PROVISIONS APPLICABLE ........................................................................................................ 18 7.2 MEASUREMENT PROCEDURE ................................................................................................. 18 7.3 TEST SETUP BLOCK DIAGRAM ................................................................................................ 18 7.4 MEASUREMENT RESULT .......................................................................................................... 19 8. SPURIOUS RATIATED EMISSION ...................................................................................................... 21 8.1 PROVISIONS APPLICABLE ........................................................................................................ 21 8.2 MEASUREMENT PROCEDURE ................................................................................................. 21 8.3 TEST SETUP BLOCK DIAGRAM ................................................................................................ 22 8.4 MEASUREMENT RESULTS: ....................................................................................................... 23 8.5 EMISSION MASK PLOT .............................................................................................................. 27 9. MODULATION CHARACTERISTICS ................................................................................................... 30 9.1 PROVISIONS APPLICABLE ........................................................................................................ 30 9.2 MEASUREMENT METHOD ......................................................................................................... 30 9.3 MEASUREMENT RESULT .......................................................................................................... 31 Report No.: AGC00725200401FE10 Page 4 of 51 10. MAXIMUMN TRANSMITTER POWER (CONDUCTED OUTPUT POWER) PEAK POWER ................. 34 10.1 PROVISIONS APPLICABLE .......................................................................................................... 34 10.2 TEST PROCEDURE ...................................................................................................................... 34 10.3 TEST CONFIGURATION ............................................................................................................... 34 10.4 TEST RESULT .........................................................................................................…
Text truncated - open the document above for the full version.
Test Setup Photos RADIATED EMISSION TEST SETUP RADIATED EMISSION ABOVE 1G TEST SETUP CONDUCTED TEST SETUP
2F.,No.2 Building, Huafeng No.1 · Baoan District, Shenzhen · China
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 2 | 9 | 47 MHz - 47.93 MHz | 50 W | 16K0F3E | 1.083 ppm |
VHF FM TRANSCEIVER
Equipment Class
CSR - Scanning Receiver
VHF/UHF DUAL BAND FM TRANSCEIVER
Equipment Class
JAV - Other Non-Digital SDoC Devices
UHF FM TRANSCEIVER
Equipment Class
TNF - Licensed Non-Broadcast Transmitter Held to Face
VHF FM TRANSCEIVER
Equipment Class
CSR - Scanning Receiver
DMR VHF/UHF MOBILE TRANSCEIVER
Equipment Class
CSR - Scanning Receiver