Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
User Manual WiMAX Modem Manual Version: 1.3 Manual Date: Feb. 20 2009 Software Version: R4.6.0.0-17743-v5.7.0 Software Date: Feb. 20 2009 i CONTENTS Chapter 1 Overview ..................................................................1-1 1.1. Indoor CPE............................................................................................. 1-1 1.2. Outdoor CPE .......................................................................................... 1-2 Chapter 2 WEB-GUI.................................................................2-3 2.1. System Configuration Login.................................................................. 2-3 2.2. System Logout ....................................................................................... 2-6 2.3. Account .................................................................................................. 2-7 2.4. Date ........................................................................................................ 2-8 2.5. Language................................................................................................ 2-9 2.6. Scanner................................................................................................. 2-10 2.7. Authentication.......................................................................................2-11 2.8. Bridge Mode ........................................................................................ 2-13 2.9. NAT Mode ........................................................................................... 2-14 2.10. Firewall ................................................................................................ 2-15 2.11. DHCP Server........................................................................................ 2-17 2.12. NAT ALG ............................................................................................. 2-19 2.13. Port Forwarding ................................................................................... 2-20 2.14. Port Trigger .......................................................................................... 2-21 2.15. DDNS................................................................................................... 2-22 2.16. TR-069 ................................................................................................. 2-24 2.17. SNMP................................................................................................... 2-26 2.18. Log ....................................................................................................... 2-27 2.19. Upgrade................................................................................................ 2-28 2.20. Recovery .............................................................................................. 2-30 2.21. Reboot .................................................................................................. 2-31 ii FIGURES Figure 1-1 Indoor CPE Front Panel LED ............................................... 1-1 Figure 1-2 Outdoor CPE installation ...................................................... 1-2 Figure 2-1 Login Page ............................................................................ 2-3 Figure 2-2 WiMAX Status ...................................................................... 2-4 Figure 2-3 WiMAX Status-Service Flow ............................................... 2-4 Figure 2-4 Network Status ...................................................................... 2-5 Figure 2-5 Device Status......................................................................... 2-5 Figure 2-6 Logout ................................................................................... 2-6 Figure 2-7 Account ................................................................................. 2-7 Figure 2-8 Date ....................................................................................... 2-8 Figure 2-9 Language ............................................................................... 2-9 Figure 2-10 Scanner with Bandwidth range ......................................... 2-10 Figure 2-11 Authentication ....................................................................2-11 Figure 2-12 Authentication-View Certificates...................................... 2-12 Figure 2-13 Bridge Mode...................................................................... 2-13 Figure 2-14 NAT Mode......................................................................... 2-14 Figure 2-15 Firewall ............................................................................. 2-15 Figure 2-16 Firewall Filter.................................................................... 2-16 Figure 2-17 DHCP Server Enabled....................................................... 2-17 Figure 2-18 DHCP Server Disabled...................................................... 2-18 Figure 2-19 NAT ALG .......................................................................... 2-19 Figure 2-20 Port Forwarding ................................................................ 2-20 Figure 2-21 Port Trigger ....................................................................... 2-21 Figure 2-22 DDNS Enabled.................................................................. 2-22 Figure 2-23 DDNS Disabled................................................................. 2-23 Figure 2-24 TR-069 .............................................................................. 2-25 Figure 2-25 TR-069-Certificate File Upload ........................................ 2-25 Figure 2-26 SNMP enabled................................................................... 2-26 Figure 2-27 SNMP disabled.................................................................. 2-26 Figure 2-28 Log .................................................................................... 2-27 Figure 2-29 Web/FTP Upgrade ............................................................. 2-28 Figure …
Text truncated - open the document above for the full version.
Airspan Networks Inc. 777 Yamato Rd Suite 310, Boca Raton, Florida, United States, 33431 F C C D F S D E C L A R A T I O N L E T T E R FCC ID: PIDASMAX2300 Date: 2011.07.19 To whom it may concern: We, the undersigned, declare that the M-PRO-V72-235I doesn’t have“Ad Hoc on non-US frequencies” and/or “on DFS frequencies”. By M-PRO-V72-235I hardware configuration, the maximum ratio of DL:UL is 31:16. That means it can not support the higher ratio then 31:16. The ratio can mot be modified to higher ratio then 31:16 by any method. Sincerely, Richard Tier Engineering Dept. Airspan Networks Inc. Tel: +1 561 893 8686 Fax: +1 561 893 8671 e-mail: [email protected]
Airspan Networks Inc. 777 Yamato Rd Suite 310, Boca Raton, Florida, United States, 33431 FCC ID: PIDASMAX2300 Date: 2011.07.19 F E D E R A L C O M M U N I C A T I O N S C O M M I S S I O N Authorization and Evaluation Division C o n f i d e n t i a l i t y R e q u e s t Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, the applicant hereby requests confidential treatment of information accompanying this application as outlined below: Schematics Block Diagram BOM Tune up procedure Operational description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Rule 0.457, disclosure of this application and all accompanying documentation will not be made before the date of the grant for this application. Sincerely, Richard Tier Engineering Dept. Airspan Networks Inc. Tel: +1 561 893 8686 Fax: +1 561 893 8671 e-mail: [email protected]
Airspan Networks Inc. 777 Yamato Rd Suite 310, Boca Raton, Florida, United States, 33431 A G E N C Y A U T H O R I Z A T I O N L E T T E R FCC ID: PIDASMAX2300 Date: 2011.07.19 To whom it may concern: We, the undersigned, hereby authorize Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch (BV CPS Taoyuan) of Taiwan to act on our behalf, as our agent, in the following matters related to the FCC approval of our products: report submittal, related correspondence, the signing of all documents relating to these matters, and any other lawful activity necessary to obtain such certification. Any act carried out by BV CPS Taoyuan within the scope of this authorization shall have the same effects as our own. This authorization shall expire 6 months from original date. If you have any questions regarding the authorization, please don’t hesitate to contact us. Thank you. Sincerely, Richard Tier Engineering Dept. Airspan Networks Inc. Tel: +1 561 893 8686 Fax: +1 561 893 8671 e-mail: [email protected]
Airspan Networks Inc. 777 Yamato Rd Suite 310, Boca Raton, Florida, United States, 33431 FCC DFS DECLARATION LETTER FCC ID: PIDASMAX2300 Date: 2011.11.04 To whom it may concern: We, the undersigned, declare that the M-PRO-V72-235I hardware configuration, used for 2316.75 MHz and 2348.25 MHz as well as 3.5 MHz emission bandwidth only. The Frequency can not be modified by any method. Sincerely, Richard Tier Engineering Dept. Airspan Networks Inc. Tel: +1 561 893 8686 Fax: +1 561 893 8671 e-mail: [email protected]
Airspan Networks Inc. 777 Yamato Rd Suite 310, Boca Raton, Florida, United States, 33431 F C C D E C L A R A T I O N L E T T E R FCC ID: PIDASMAX2300 Date: 2011.11.08 To whom it may concern: By M-PRO-V72-235I hardware configuration, the maximum ratio of DL:UL is 31:16. That means it can not support the higher ratio then 31:16. The ratio can not be modified to higher ratio then 31:16 by any method. The device do not support mobile station FDD mode. Sincerely, Richard Tier Engineering Dept. Airspan Networks Inc. Tel: +1 561 893 8686 Fax: +1 561 893 8671 e-mail: [email protected]
FCC Home | Search | RSS | Updates | E-Filing | Initiatives | Consumers | Find People Office of Engineering and Technology To: Gary Chang, Bureau Veritas CPS (H.K.) Ltd. Taoyuan Branch [email protected] From: Jyun-Cheng Chen [email protected] Re: FCC ID: PIDASMAX2300 Applicant: Airspan Networks Inc Correspondence Reference Number: 40466 Form 731 Confirmation Number: EA879194 Date of Original E-mail: 10/25/2011 Thank you for your 10/14 response to my 9/23 request for clarification. After review of your application, please address the following issues: 1. The WiMAX duty cycle attestation letter is incorrectly titled "DFS Declaration." Please also clarify what is considered to be "higher ratio than 31:16" in the letter? Is 32:15 a higher or lower ratio? The ratio in our original description is “upload symbol length divided by frame length (i.e. ratio=UL/frame length=16/48 for DL/UL ration of 31:16)” 2. Does the device support mobile station FDD mode? If not, please add in the above TDD duty cycle attestation letter. If yes, please describe the FDD usage. The device does not support FDD mode. 3. Please elaborate on "Hardware configuration for the device is only for 2316.75 MHz and 2348.25 MHz and can not be modified by any method to support any other frequency." (10/14 Letter) Unfortunately, we could not verify this statement with the block diagram and the schematics. Due to this and information presented elsewhere in the application, an attestation statement is required that the EUT will only operate on the two fixed frequencies 2316.75 MHz and 2348.25 MHz as well as 5 MHz emission bandwidth only. In addition, please explain how this hardware configuration is accomplished. The channel limitation is implemented by both software and hardware. The system software is programmed to limit the selection only from channel 2316.75MHz or 2348.25MHz. Also, an external dual band‐pass filter is attached to the system as show in the attached block diagram. The band‐pass filter is such designed that it will allow only mentioned two channel frequency (with 5MHz channel BW, please refer to attached filter spec) to pass through the system for signal purity enhancement. As explained, either from software or hardware limitation, the system will allow only two mentioned channels and BW to work and there is no other combination for user to select from. We hope this clarify the concern. 4. Per 47 CFR 27.50(a)(2), fixed CPE equipment must employ automatic transmit power control (ATPC). Please attest ATPC has been implemented or elaborate on the reason for exemption. ATPC is a test item for WiMAX forum CRT. Please check following requirement from WiMAX forum RCT test and also check attached WiMAX certificate. 5. Please correct inconsistency of different MPE distances listed. On the FCC label it is stated to be 20 cm, and 50 cm on Page 2‐34 of the User Manual. Based on calculation, actually 21 cm (20.48 cm to be exact) is sufficient to meet the MPE limit. 50cm is the safety distance defined by client. And we find 20 cm is mentioned on label sample only. Revised label sample will be provided to FCC website. 6. Please explain why QPSK is selected for emission bandwidth, peak‐to‐average ration, band edge and spurious emission measurement while 16QAM is known to have higher peak‐to‐average ratio and more susceptible to noise and hardware imperfection and thus would result in wider bandwidth? Adding 16QAM test for peak‐to average, bandwidth and band edge measurement. P23~24 of revised report is for bandwidth measurement P27 of revised report is for peak to average ratio. P34`37 of revised report is for band edge measurement.
Page 1 CONSTRUCTION PHOTOS OF EUT Page 2 Page 3 Page 4 Page 5 Page 6 Page 7
Airspan M-Pro-V72-235I Product Label
Page 8 Page 9 Page 10 Page 11 Page 12
Report No.: SA110616C18 Report Format Version 4.0.0 1 RF EXPOSURE REPORT REPORT NO.: SA110616C18 MODEL NO.: M-PRO-V72-235I FCC ID: PIDASMAX2300 APPLICANT: Gemtek Technology Co., Ltd. ADDRESS: No. 15-1, Zhonghua Rd, Hsinchu Industrial Park, Hsinchu County, Taiwan, R.O.C. 303 ISSUED BY: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch LAB ADDRESS: No. 47, 14th Ling, Chia Pau Tsuen, Lin Kou Hsiang, Taipei Hsien 244, Taiwan, R.O.C. TEST LOCATION: No. 19, Hwa Ya 2nd Rd, Wen Hwa Tsuen, Kwei Shan Hsiang, Taoyuan Hsien 333, Taiwan, R.O.C. This test report consists of 5 pages in total. It may be duplicated completely for legal use with the approval of the applicant. It should not be reproduced, except in full, without the written approval of our laboratory. The client should not use it to claim product certification, approval or endorsement by any government agency. The test results in the report only apply to the tested sample. Report No.: SA110616C18 Report Format Version 4.0.0 2 TABLE OF CONTENTS RELEASE CONTROL RECORD ............................................................................................. 3 1. CERTIFICATION .......................................................................................................... 4 2. RF EXPOSURE............................................................................................................ 5 2.1 LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)...................................... 5 2.2 MPE CALCULATION FORMULA ................................................................................. 5 2.3 CLASSIFICATION ........................................................................................................ 5 2.4 CALCULATION RESULT OF MAXIMUM CONDUCTED POWER............................... 5 Report No.: SA110616C18 Report Format Version 4.0.0 3 RELEASE CONTROL RECORD ISSUE NO. REASON FOR CHANGE DATE ISSUED Original release NA Aug. 16, 2011 Report No.: SA110616C18 Report Format Version 4.0.0 4 1. CERTIFICATION PRODUCT: WiMAX Outdoor CPE MODEL: M-PRO-V72-235I BRAND: Airspan APPLICANT: Airspan Networks Inc. TESTED: Jul. 06 ~ Aug. 15, 2011 TEST SAMPLE: ENGINEERING SAMPLE TEST STANDARDS: FCC Part 2 (Section 2.1091) FCC OET Bulletin 65, Supplement C (01-01) IEEE C95.1 The above equipment (Model: M-PRO-V72-235I) has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample’s EMC characteristics under the conditions specified in this report. PREPARED BY : , DATE :Aug. 16, 2011 Pettie Chen / Specialist APPROVED BY : , DATE : Aug. 16, 2011 Gary Chang / Technical Manager Report No.: SA110616C18 Report Format Version 4.0.0 5 2. RF EXPOSURE 2.1 LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) FREQUENCY RANGE (MHz) ELECTRIC FIELD STRENGTH (V/m) MAGNETIC FIELD STRENGTH (A/m) POWER DENSITY (mW/cm 2 ) AVERAGE TIME (minutes) LIMITS FOR GENERAL POPULATION / UNCONTROLLED EXPOSURE 300-1500 ... ... F/1500 30 1500-100,000 ... ... 1.0 30 F = Frequency in MHz 2.2 MPE CALCULATION FORMULA Pd = (Pout*G) / (4*pi*r2) where Pd = power density in mW/cm2 Pout = output power to antenna in mW G = gain of antenna in linear scale Pi = 3.1416 R = distance between observation point and center of the radiator in cm 2.3 CLASSIFICATION The antenna of this product, under normal use condition, is at least 50cm away from the body of the user. So, this device is classified as Mobile Device. 2.4 CALCULATION RESULT OF MAXIMUM CONDUCTED POWER MAX POWER (dBm) MAXIMUM ANTENNA GAIN (dBi) DISTANCE (cm) POWER DENSITY (mW/cm 2 ) LIMIT (mW/cm 2 ) 24.22 13 50 0.168 1.00
Report No.: SA110616C18 Report Format Version 4.0.0 1 RF EXPOSURE REPORT REPORT NO.: SA110616C18 MODEL NO.: M-PRO-V72-235I FCC ID: PIDASMAX2300 APPLICANT: Gemtek Technology Co., Ltd. ADDRESS: No. 15-1, Zhonghua Rd, Hsinchu Industrial Park, Hsinchu County, Taiwan, R.O.C. 303 ISSUED BY: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch LAB ADDRESS: No. 47, 14th Ling, Chia Pau Tsuen, Lin Kou Hsiang, Taipei Hsien 244, Taiwan, R.O.C. TEST LOCATION: No. 19, Hwa Ya 2nd Rd, Wen Hwa Tsuen, Kwei Shan Hsiang, Taoyuan Hsien 333, Taiwan, R.O.C. This test report consists of 5 pages in total. It may be duplicated completely for legal use with the approval of the applicant. It should not be reproduced, except in full, without the written approval of our laboratory. The client should not use it to claim product certification, approval or endorsement by any government agency. The test results in the report only apply to the tested sample. Report No.: SA110616C18 Report Format Version 4.0.0 2 TABLE OF CONTENTS RELEASE CONTROL RECORD ............................................................................................. 3 1. CERTIFICATION .......................................................................................................... 4 2. RF EXPOSURE............................................................................................................ 5 2.1 LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)...................................... 5 2.2 MPE CALCULATION FORMULA ................................................................................. 5 2.3 CLASSIFICATION ........................................................................................................ 5 2.4 CALCULATION RESULT OF MAXIMUM CONDUCTED POWER............................... 5 Report No.: SA110616C18 Report Format Version 4.0.0 3 RELEASE CONTROL RECORD ISSUE NO. REASON FOR CHANGE DATE ISSUED Original release NA Aug. 16, 2011 Report No.: SA110616C18 Report Format Version 4.0.0 4 1. CERTIFICATION PRODUCT: WiMAX Outdoor CPE MODEL: M-PRO-V72-235I BRAND: Airspan APPLICANT: Airspan Networks Inc. TESTED: Jul. 06 ~ Aug. 15, 2011 TEST SAMPLE: ENGINEERING SAMPLE TEST STANDARDS: FCC Part 2 (Section 2.1091) FCC OET Bulletin 65, Supplement C (01-01) IEEE C95.1 The above equipment (Model: M-PRO-V72-235I) has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample’s EMC characteristics under the conditions specified in this report. PREPARED BY : , DATE :Aug. 16, 2011 Pettie Chen / Specialist APPROVED BY : , DATE : Aug. 16, 2011 Gary Chang / Technical Manager Report No.: SA110616C18 Report Format Version 4.0.0 5 2. RF EXPOSURE 2.1 LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) FREQUENCY RANGE (MHz) ELECTRIC FIELD STRENGTH (V/m) MAGNETIC FIELD STRENGTH (A/m) POWER DENSITY (mW/cm 2 ) AVERAGE TIME (minutes) LIMITS FOR GENERAL POPULATION / UNCONTROLLED EXPOSURE 300-1500 ... ... F/1500 30 1500-100,000 ... ... 1.0 30 F = Frequency in MHz 2.2 MPE CALCULATION FORMULA Pd = (Pout*G) / (4*pi*r2) where Pd = power density in mW/cm2 Pout = output power to antenna in mW G = gain of antenna in linear scale Pi = 3.1416 R = distance between observation point and center of the radiator in cm 2.3 CLASSIFICATION The antenna of this product, under normal use condition, is at least 50cm away from the body of the user. So, this device is classified as Fixed Device. 2.4 CALCULATION RESULT OF MAXIMUM CONDUCTED POWER MAX POWER (dBm) MAXIMUM ANTENNA GAIN (dBi) DISTANCE (cm) POWER DENSITY (mW/cm 2 ) LIMIT (mW/cm 2 ) 24.22 13 50 0.168 1.00
Report No.: SA110616C18 Report Format Version 4.0.0 1 RF EXPOSURE REPORT REPORT NO.: SA110616C18 MODEL NO.: M-PRO-V72-235I FCC ID: PIDASMAX2300 APPLICANT: Gemtek Technology Co., Ltd. ADDRESS: No. 15-1, Zhonghua Rd, Hsinchu Industrial Park, Hsinchu County, Taiwan, R.O.C. 303 ISSUED BY: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch LAB ADDRESS: No. 47, 14th Ling, Chia Pau Tsuen, Lin Kou Hsiang, Taipei Hsien 244, Taiwan, R.O.C. TEST LOCATION: No. 19, Hwa Ya 2nd Rd, Wen Hwa Tsuen, Kwei Shan Hsiang, Taoyuan Hsien 333, Taiwan, R.O.C. This test report consists of 5 pages in total. It may be duplicated completely for legal use with the approval of the applicant. It should not be reproduced, except in full, without the written approval of our laboratory. The client should not use it to claim product certification, approval or endorsement by any government agency. The test results in the report only apply to the tested sample. Report No.: SA110616C18 Report Format Version 4.0.0 2 TABLE OF CONTENTS RELEASE CONTROL RECORD ............................................................................................. 3 1. CERTIFICATION .......................................................................................................... 4 2. RF EXPOSURE............................................................................................................ 5 2.1 LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)...................................... 5 2.2 MPE CALCULATION FORMULA ................................................................................. 5 2.3 CLASSIFICATION ........................................................................................................ 5 2.4 CALCULATION RESULT OF MAXIMUM CONDUCTED POWER............................... 5 Report No.: SA110616C18 Report Format Version 4.0.0 3 RELEASE CONTROL RECORD ISSUE NO. REASON FOR CHANGE DATE ISSUED Original release NA Nov. 17, 2011 Report No.: SA110616C18 Report Format Version 4.0.0 4 1. CERTIFICATION PRODUCT: WiMAX Outdoor CPE MODEL: M-PRO-V72-235I BRAND: Airspan APPLICANT: Airspan Networks Inc. TESTED: Jul. 06 ~ Nov. 17, 2011 TEST SAMPLE: ENGINEERING SAMPLE TEST STANDARDS: FCC Part 2 (Section 2.1091) FCC OET Bulletin 65, Supplement C (01-01) IEEE C95.1 The above equipment (Model: M-PRO-V72-235I) has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample’s EMC characteristics under the conditions specified in this report. PREPARED BY : , DATE :Nov. 17, 2011 Pettie Chen / Specialist APPROVED BY : , DATE : Nov. 17, 2011 Gary Chang / Technical Manager Report No.: SA110616C18 Report Format Version 4.0.0 5 2. RF EXPOSURE 2.1 LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) FREQUENCY RANGE (MHz) ELECTRIC FIELD STRENGTH (V/m) MAGNETIC FIELD STRENGTH (A/m) POWER DENSITY (mW/cm 2 ) AVERAGE TIME (minutes) LIMITS FOR GENERAL POPULATION / UNCONTROLLED EXPOSURE 300-1500 ... ... F/1500 30 1500-100,000 ... ... 1.0 30 F = Frequency in MHz 2.2 MPE CALCULATION FORMULA Pd = (Pout*G) / (4*pi*r2) where Pd = power density in mW/cm2 Pout = output power to antenna in mW G = gain of antenna in linear scale Pi = 3.1416 R = distance between observation point and center of the radiator in cm 2.3 CLASSIFICATION The antenna of this product, under normal use condition, is at least 50cm away from the body of the user. So, this device is classified as Fixed Device. 2.4 CALCULATION RESULT OF MAXIMUM CONDUCTED POWER MAX POWER (dBm) MAXIMUM ANTENNA GAIN (dBi) DISTANCE (cm) POWER DENSITY (mW/cm 2 ) LIMIT (mW/cm 2 ) 29.8 13 50 0.607 1.00
Report No.: RF110616C18 1 Report Format Version 4.0.0 FCC TEST REPORT (PART 27) REPORT NO.: RF110616C18 MODEL NO.: M-PRO-V72-235I FCC ID: PIDASMAX2300 RECEIVED: Jun. 16, 2011 TESTED: Jul. 06 ~ Aug. 15, 2011 ISSUED: Aug. 16, 2011 APPLICANT: Airspan Networks Inc. ADDRESS: 777 Yamato Rd Suite 310, Boca Raton, Florida, United States, 33431 ISSUED BY: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch LAB ADDRESS: No. 47, 14th Ling, Chia Pau Tsuen, Lin Kou Hsiang, Taipei Hsien 244, Taiwan, R.O.C. TEST LOCATION: No. 19, Hwa Ya 2nd Rd, Wen Hwa Tsuen, Kwei Shan Hsiang, Taoyuan Hsien 333, Taiwan, R.O.C. This test report consists of 48 pages in total. It may be duplicated completely for legal use with the approval of the applicant. It should not be reproduced except in full, without the written approval of our laboratory. The client should not use it to claim product certification, approval, or endorsement by TAF or any government agency. The test results in the report only apply to the tested sample. Report No.: RF110616C18 2 Report Format Version 4.0.0 TABLE OF CONTENTS RELEASE CONTROL RECORD..............................................................................................4 1 CERTIFICATION...........................................................................................................5 2 SUMMARY OF TEST RESULTS ..................................................................................6 2.1 MEASUREMENT UNCERTAINTY................................................................................6 3 GENERAL INFORMATION ...........................................................................................7 3.1 GENERAL DESCRIPTION OF EUT .............................................................................7 3.2 DESCRIPTION OF TEST MODES ...............................................................................8 3.2.1 CONFIGURATION OF SYSTEM UNDER TEST ..........................................................8 3.2.2 TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL ...............................9 3.3 GENERAL DESCRIPTION OF APPLIED STANDARDS ............................................12 3.4 DESCRIPTION OF SUPPORT UNITS .......................................................................12 4 TEST TYPES AND RESULTS ....................................................................................13 4.1 OUTPUT POWER MEASUREMENT .........................................................................13 4.1.1 LIMITS OF OUTPUT POWER MEASUREMENT .......................................................13 4.1.2 TEST INSTRUMENTS................................................................................................13 4.1.3 TEST PROCEDURES ................................................................................................14 4.1.4 TEST SETUP..............................................................................................................14 4.1.5 EUT OPERATING CONDITIONS ...............................................................................14 4.1.6 TEST RESULTS .........................................................................................................15 4.2 FREQUENCY STABILITY MEASUREMENT..............................................................16 4.2.1 LIMITS OF FREQUENCY STABILIITY MEASUREMENT ..........................................16 4.2.2 TEST INSTRUMENTS................................................................................................16 4.2.3 TEST PROCEDURE...................................................................................................17 4.2.4 TEST SETUP..............................................................................................................17 4.2.5 EUT OPERATING CONDITIONS ...............................................................................17 4.2.6 TEST RESULTS .........................................................................................................18 4.3 EMISSION BANDWIDTH MEASUREMENT ..............................................................19 4.3.1 LIMITS OF EMISSION BANDWIDTH MEASUREMENT ............................................19 4.3.2 TEST INSTRUMENTS................................................................................................19 4.3.3 TEST PROCEDURE...................................................................................................19 4.3.4 TEST SETUP..............................................................................................................20 4.3.5 EUT OPERATING CONDITIONS ...............................................................................20 4.3.6 TEST RESULTS .........................................................................................................21 4.4 PEAK TO AVERAGE RATIO...........................…
Text truncated - open the document above for the full version.
No. 19, Hwa Ya 2nd Rd., Kwei Shan Hsiang · Taoyuan Hsien · Taiwan
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 2 | 27 | 2.35 GHz - 2.35 GHz | 5.272 W | 3M49W7D | 2.5 ppm |

LTE Base Station
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
B42H/B43L/B48
Equipment Class
CBD - Citizens Band Category A and B Devices
LTE Base Station Radio
Equipment Class
CBD - Citizens Band Category A and B Devices
Base station of LTE fixed cellular system
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Base station of LTE fixed cellular system
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter