FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Airspan Networks Inc/
  3. PIDMARCONI4

PIDMARCONI4Wireless IP-Based Local Loop System

Airspan Networks Inc
Wireless IP-Based Local Loop System - FCC ID PIDMARCONI4 - Airspan Networks Inc
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Feb 06, 2002
Application Purpose
Original Equipment
Date of Application
Feb 04, 2002
Equipment Note
Wireless IP-Based Local Loop System
Frequency Range
2403.00000000 - 2477.00000000
Company
Airspan Networks Inc
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Operational Description

↗
↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

WipLL Wireless IP-Based Local Loop System Release 2.0.1 WipLL System Description 1QDF10134AAP-SYD-FCC Issue 03 4 Mbit - Draft 05 This product is marked with a CE Mark. This mark has been affixed to demonstrate full product compliance with the following European directives: a) Directive 73/23/EEC - Council Directive of 19/02/1973 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits. b) Directive 89/336/EEC - Council Directive of 3/05/1989 on the approximation of laws of the Member States relating to Electro- Magnetic Compatibility (EMC). This product has been tested and found to comply with the requirements listed in FCC Regulations Part 15 for Class “B” digital devices. Compliance with these requirements provides a reasonable level of assurance that use of this product in a residential environment will not result in harmful interference with other electronic devices. This equipment generates/uses radio frequencies and if not installed and used according to the instructions found in the manuals, may cause interference harmful to the operation of other electronic devices. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna • Increase the separation between the equipment and the receiver • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected • Consult the dealer or an experienced radio/TV technician for help Changes or modifications to this equipment not expressly approved by Marconi Ltd., could void the user’s authority to operate the equipment. The information contained in this document is proprietary and is subject to all relevant copyright, patent and other laws protecting intellectual property, as well as any specific agreement protecting MARCONI COMMUNICATIONS LTD.’s rights in the aforesaid information. Neither this document nor the information contained herein may be published, reproduced or disclosed to third parties, in whole or in part, without the express, prior, written permission of MARCONI COMMUNICATIONS LTD. In addition, any use of this document or the information contained herein for any purposes other than those for which it was disclosed is strictly forbidden. MARCONI COMMUNICATIONS LTD. reserves the right, without prior notice or liability, to make changes in equipment design or specifications. Information supplied by MARCONI COMMUNICATIONS LTD. is believed to be accurate and reliable. However, no responsibility is assumed by MARCONI COMMUNICATIONS LTD. for the use thereof nor for the rights of third parties which may be affected in any way by the use thereof. Any representation(s) in this document concerning performance of MARCONI COMMUNICATIONS LTD. product(s) are for informational purposes only and are not warranties of future performance, either express or implied. MARCONI COMMUNICATIONS LTD. standard limited warranty, stated in its sales contract or order confirmation form, is the only warranty offered by MARCONI COMMUNICATIONS LTD. in relation thereto. This document may contain flaws, omissions or typesetting errors; no warranty is granted nor liability assumed in relation thereto unless specifically undertaken in MARCONI COMMUNICATIONS LTD. sales contract or order confirmation. Information contained herein is periodically updated and changes will be incorporated into subsequent editions. If you have encountered an error, please notify MARCONI COMMUNICATIONS LTD. All specifications are subject to change without prior notice. Issue Date: 6-Feb-02 Revision Record: WipLL System Description Pub. Rev. Date Update Description 1.2 Nov-00 First edition and printing. Author: MCIL 1.4 Mar-01 WipLL Release 1.4 Issue 03 2.0 Apr-01 WipLL Release 2.0 Issue 01 Issue Date: 6-Feb-02 Publication No. 1QDF10134AAP-SYD-FCC  Copyright by MARCONI COMMUNICATIONS LTD, 2001. All rights reserved worldwide. QUESTIONS / COMMENTS If you have questions or comments about this publication, please e-mail to [email protected] Name Company Tel/Fax/e-mail: Publication Name: Catalogue No. My question/comment is: Thank you. Marconi Communications Ltd Marketing Department This page intentionally left blank Contents 1QDF10134AAP-SYD-FCC Issue 03 4 Mbit - Draft 05 i Contents 1 GENERAL OVERVIEW ............................................................................. 1-1 1.1. Components of the System ................................................................. 1-4 1.1.1. The Subscriber Site .............................................................. 1-5 1.1.2. Base Station Components .................................................... 1-6 1.1.3. Coverage .............................................................................. 1-7 1.2. Management, and Commissioning...................................................... 1-9 1.2.1. WipManage ........................................................................ 1-10 1.2.2. WipConfig ........................................................................... 1-10 2 MAIN FEATURES, PROTOCOL AND QoS .............................................. 2-1 2.1. Features .......................................................................................…

Text truncated - open the document above for the full version.

Block Diagram

26-Jul -9 8 R. E. SAW SAW - - Rx Rx 20 db Gai n cont rol 40 db Gai n cont rol SAW SAW - - Tx Tx Dat a Cl k Stb PLL GC T/R TGC Dat a Cl k Stb DAC x 8 1-Vtcxo 2-TGC 3-RGC 4-Vcgy121 5-V2126 1Vppon50 O Hm T/R TxPD TxPD Di v T/R Tx Di v T/R T/R VTCXO VTCXO +-20 PPM FrequencyCont rol To PLL 20 db Gai n cont rol TxPD Rx RSSI °C Tem p 6V RGC TGC DAC #5 DAC #1 DAC #3 DAC #2 DAC #4 20M Hz 2050M Hz – 20150M Hz 356M Hz

Cover Letter(s)

American Telecommunications Certification Body Inc. 6731 Whittier Ave, McLean, VA 22101 January 22, 2002 RE: Marconi Communications FCC ID: PIDMARCONI4 I have a few comments on this Application. 1.) Are all the antennas defined for this equipment? If so, could you please direct me where in this Application they exist? Please identify them by type and / or model number. 2.) Are you defining this as Fixed or Mobile for the purposes of RF Exposure? Are there any RF Exposure safety statements in the manual? If so, please indicate where they are located. 3.) Are the same antennas used for both the low and high power transmitters? If not, please provide a matrix of permitted antennas. 4.) There is a factor of 3 difference between low and high power units. Please provide a parts list noting differences between these two models. If just a software setting, please indicate. William H. Graff President and Examining Engineer mailto: [email protected] The items indicated above must be submitted before processing can continue on the above referenced application. Failure to provide the requested information may result in application termination. Correspondence should be considered part of the permanent submission and may be viewed from the Internet after a Grant of Equipment Authorization is issued. Please do not respond to this correspondence using the email reply button. In order for your response to be processed expeditiously, you must submit your documents through the AmericanTCB.com website. Also, please note that partial responses increase processing time and should not be submitted. Any questions about the content of this correspondence should be directed to the sender.

Cover Letter(s)

Marconi Communications Israel Limited Registered in Israel. No. 51-279477-7 Marconi Communications Israel Ltd 1 Hamlacha St., LOD 71293, Israel T: +972-8-9777000 ; F: +972-8-9777050 www.marconicomms.com American TCB 6731 Whittier Ave Suite C110 McLean, VA 22101 USA Subject: Application for certification of frequency hopping transceiver, model names BSR-2.4 (4 Mbit/s) and SPR-2.4 (4 Mbit/s), FCC ID:PIDMARCONI4 Dear Gentlemen, Please find attached our application for certification of frequency hopping transceiver, model names BSR- 2.4 (4 Mbit/s) and SPR-2.4 (Mbit/s), FCC ID:PIDMARCONI4, prepared in accordance with FCC Rules, parts 2 and 15. We apply to you with request to withhold Marconi Communications Ltd. trade secret in Application for Certification for FCC ID: PIDMARCONI. These trade secrets can be found in the BSR-2.4 and SPR-2.4 schematic diagram (5 pages of this Application). The product testing and this application for certification were performed by Hermon Laboratories, which is listed by FCC. Hermon Labs responsibleperson is Dr. Edward Usoskin, tel: 011 972 6628 8001, fax:011 972 6628 8277, e-mail: [email protected] We hope this application satisfies your requirements Sincerely yours Mr. Shmuel Bleichman, VP engineering Marconi Communications Ltd.

Cover Letter(s)

American Telecommunications Certification Body Inc. 6731 Whittier Ave, McLean, VA 22101 January 22, 2002 RE: Marconi Communications FCC ID: PIDMARCONI4 I have a few comments on this Application. 1.) Are all the antennas defined for this equipment? If so, could you please direct me where in this Application they exist? Please identify them by type and / or model number. 2.) Are you defining this as Fixed or Mobile for the purposes of RF Exposure? Are there any RF Exposure safety statements in the manual? If so, please indicate where they are located. 3.) Are the same antennas used for both the low and high power transmitters? If not, please provide a matrix of permitted antennas. 4.) There is a factor of 3 difference between low and high power units. Please provide a parts list noting differences between these two models. If just a software setting, please indicate. William H. Graff President and Examining Engineer mailto: [email protected] The items indicated above must be submitted before processing can continue on the above referenced application. Failure to provide the requested information may result in application termination. Correspondence should be considered part of the permanent submission and may be viewed from the Internet after a Grant of Equipment Authorization is issued. Please do not respond to this correspondence using the email reply button. In order for your response to be processed expeditiously, you must submit your documents through the AmericanTCB.com website. Also, please note that partial responses increase processing time and should not be submitted. Any questions about the content of this correspondence should be directed to the sender.

External Photos

FCC ID:PIDMARCONI Date: March, 2001 Page 1 of 4 EXTERNAL PHOTOGRAPHS This document contains 3 photographs FCC ID:PIDMARCONI Date: March, 2001 Page 2 of 4 Photograph No.1 BSR-2.4 with SDA general view FCC ID:PIDMARCONI Date: March, 2001 Page 3 of 4 Photograph No.2 BSR-2-4 general view FCC ID:PIDMARCONI Date: March, 2001 Page 4 of 4 Photograph No.3 SPR-2.4 general view

ID Label/Location Info

FCC ID:PIDMARCONI Date: March, 2001 Project number:14534, 14551 Page 1 of 1 LABEL The label shown below is affixed on the bottom of the BSR-2.4 (4 Mbit/s) and SPR-2.4 (4 Mbit/s) radio units. The label dimensions are 70 x 30 (mm), material - PVC with a permanent adhesive. The manufacturer and EUT names are silk screened on the bottom. The FCC part 15, §15.105 statement is placed in User Manual (System Description), page 1-9. Label placement on the EUT bottom Label FCC ID:PIDMARCONI4 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.

Internal Photos

FCC ID: PIDMARCONI; BSR-2.4 inside view with covers FCC ID:PIDMARCONI; BSR-2.4 inside view (antenna) FCC ID:PIDMARCONI; BSR-2.4 inside view without covers FCC ID:PIDMARCONI; BSR-2.4 inside view, rear side FCC ID:PIDMARCONI; BSR-2.4 main board front view FCC ID:PIDMARCONI; BSR-2.4 main board rear view FCC ID:PIDMARCONI; BSR-RF2.4 board, printed side FCC ID:PIDMARCONI; BSR-RF2.4 board, component side FCC ID:PIDMARCONI; SPR-2.4 inside view with covers FCC ID:PIDMARCONI; SPR-2.4 inside view (antenna) FCC ID:PIDMARCONI; SPR-2.4 inside view without covers FCC ID:PIDMARCONI; SPR-2.4 inside view, rear side FCC ID:PIDMARCONI; SPR-2.4 main board front view FCC ID:PIDMARCONI; SPR-2.4 main board front view FCC ID:PIDMARCONI; SPR-2.4 main board rear view FCC ID:PIDMARCONI; SPR-RF2.4 board, printed side FCC ID:PIDMARCONI; SPR-RF2.4 board, component side

Operational Description

Table #1Table #2Table #3Table #4Table #5Table #6Table #7Table #8Table #9 247524052411241724232429243524412447 242324292435244124472453245924652471 240724132419242524312437244324492455 247124772407241324192425243124372443 244524512457246324692475240524112417 241124172423242924352441244724532459 244324492455246124672473240324092415 245724632469247524052411241724232429 243524412447245324592465247124772407 241924252431243724432449245524612467 247324032409241524212427243324392445 240524112417242324292435244124472453 242524312437244324492455246124672473 244724532459246524712477240724132419 246724732403240924152421242724332439 240324092415242124272433243924452451 243924452451245724632469247524052411 246124672473240324092415242124272433 244124472453245924652471247724072413 241724232429243524412447245324592465 244924552461246724732403240924152421 242724332439244524512457246324692475 246524712477240724132419242524312437 243124372443244924552461246724732403 245924652471247724072413241924252431 242924352441244724532459246524712477 240924152421242724332439244524512457 247724072413241924252431243724432449 245324592465247124772407241324192425 243324392445245124572463246924752405 241324192425243124372443244924552461 245524612467247324032409241524212427 243724432449245524612467247324032409 245124572463246924752405241124172423 246924752405241124172423242924352441 242124272433243924452451245724632469 246324692475240524112417242324292435 241524212427243324392445245124572463 Table #10 Table #11 Table #12 245324592465 247724072413 246124672473 244924552461 242324292435 246524712477 242124272433 243524412447 241324192425 247324032409 245124572463 245924652471 240324092415 242524312437 244524512457 245724632469 241724232429 243924452451 241924252431 247124772407 242724332439 240524112417 244324492455 240924152421 243724432449 240724132419 246324692475 245524612467 243124372443 241124172423 246724732403 243324392445 241524212427 242924352441 244724532459 247524052411 244124472453 246924752405

Operational Description

Marconi Communications Israel Limited Registered in Israel. No. 51-279477-7 Marconi Communications Israel Ltd 1 Hamlacha St., LOD 71293, Israel T: +972-8-9777000 ; F: +972-8-9777050 www.marconicomms.com Subject: Hopping algorithm and compliance with FCC 15.247 (a) (1) 1. Hopping Algorithm description • The hopping algorithm is defined by a table of n frequencies, when n 75 when the system is configured for 1, 2 and 3Mb/s and 38 when the system configured for 4Mb/s. The hopping sequence follows cyclically the frequencies in the table, staying in each frequency for a constant period. The frequencies note the center frequencies in each hop. Each frequency in the table apearsonce. The frequencies in the table are all in the range 2402- 2482, with at least 1MHz between any two frequencies in the table when the system configured for 1, 2 and 3mb/s and at least 2MHz when system configured for 4Mb/s. The order of frequencies in the table is pseudorandom. • Attached two tables for the two modes 1MHz channel spacing and 2MHz channel spacing. 2. Hopping time The hopping time in a given is constant. (typically WipLL uses 50mSec) 3. Number of channels The number of channels is determined by the table size n which is at least 75 (WipLL uses n=79) when configured for 1, 2 and 3Mb/s and 38 frequencies when system configured for 4Mb/s. 4. Resolution The minimum difference between any two channels is 1 MHz at 1,2 and 3Mb/s. 2MHz when configured for 4Mb/s. 5. Channel distribution. Since any used channel is included once in the table, all the channels are equally used, each one occupies 1/n of the time. 6. Occupancy time. Each used channel is used once per cycle of n frequencies (n =79 see par. 3 above). The total occupancy time in 30 seconds is: (30sec)/n0.4sec 30/79 = 0.380 sec. 7. Receiver synchronization. The system receiver input bandwidth filter matches the hopping channel bandwidth and syncronized with the coresponding transmitter on the hopping sequence. 15.247 Spec.RequirementWipLL capabilityComply Spread SpecrumFHSS or DSSSFHSSyes Minimum Channel Seperation at 1,2 and 3Mb/s. Minimum Channel seperation at 4Mb/s -20dB bandwidth (1MHz) -20dB bandwidth -20dB bandwidth (1MHz) 2MHz Yes Yes List of Freq.Pseudo random ordered list.Pseudo random ordered listyes Use of Freq.Equal use of Freq.Constant hop period (50mS) each freq. used once in table. yes Frequency band2400- 2483.5MHz2402 – 2482MHzyes Number of frequencies at 1,2 and 3Mb/s Number of frequencies at Min. 75 15 non over lapping channels 79 38 Yes Yes Marconi Communications Israel Limited Registered in Israel. No. 51-279477-7 Marconi Communications Israel Ltd 1 Hamlacha St., LOD 71293, Israel T: +972-8-9777000 ; F: +972-8-9777050 www.marconicomms.com 4Mb/swith total span 75MHz Occupied BW per hop at 1,2 and 3Mb/s Occupied BW per hop at 4Mb/s <1MHz at –20dB > 1MHz <1MHz at –20dB 1MHz < BW < 2MHz at –20dB Yes Yes Average time of occupancy<0.4 sec see within 30 sec period- average. 50mSecyes Shmuel Bleichman Marconi Communications Israel Limited Registered in Israel. No. 51-279477-7 Marconi Communications Israel Ltd 1 Hamlacha St., LOD 71293, Israel T: +972-8-9777000 ; F: +972-8-9777050 www.marconicomms.com BSR flat panel Antenna at 2.45GHz ItemUnitValueNote Frequency RangeGHz2.4 to 2.5 ImpedanceOhm50 VSWR1:1.5Max PolarizationLinear / Vertical GaindBi11Min 3dB Beamwith E-plane (Ele)Deg33Max 3dB Beamwith H-plane (Az)Deg23Max Power HandlingW5Min Lightning protectionAll elements DC Grounded SidelobesETSI-TS3Min (15dB prefered) Front-to-back ratioDB25Min Cross PolarizationDB15Min Operating TemperatureºC-40 to 70 MechanicalAttached drawing RF ConnectorHuber-suhner 81MCX-50-0-6 SPR (Subscriber) flat panel Antenna at 2.45GHz ItemUnitValueNote Frequency RangeGHz2.4 to 2.5 ImpedanceOhm50 VSWR1:1.5Max PolarizationLinear / Vertical GaindBi15Min 3dB Beamwith E-plane (Ele)Deg33Max Marconi Communications Israel Limited Registered in Israel. No. 51-279477-7 Marconi Communications Israel Ltd 1 Hamlacha St., LOD 71293, Israel T: +972-8-9777000 ; F: +972-8-9777050 www.marconicomms.com 3dB Beamwith H-plane (Az)Deg23Max Power HandlingW5Min Lightning protectionAll elements DC Grounded SidelobesETSI-TS3Min (15dB prefered) Front-to-back ratioDB25Min Cross PolarizationDB15Min Operating TemperatureºC-40 to 70 MechanicalAttached drawing RF ConnectorHuber-suhner 81MCX-50-0-6

RF Exposure Info

FCC ID:PIDMARCONI Date: March, 2001 Project number:14534, 14551 Page 1 of 1 RF exposure information for BSR-2.4 (4 Mbit/s) and SPR-2.4 (4 Mbit/s) frequency hopping transceivers, operating in 2.402 – 2.480 GHz frequency band MPE limit for power density for general population/uncontrolled exposure according to FCC §1.1310 is 1 mW/cm 2 . P T A power density P (mW/cm 2 ) = ------------- , where 4 π r 2 P T - transmitted power. For BSR-2.4: P T is equal to transmitter output power 16 dBm plus maximum antenna gain 11 dBi, the maximum equivalent isotropically radiated power (e.i.r.p.) is 27 dBm = 501.2 mW. 1(mW/cm 2 ) = 501.2 mW / 4 π r 2 Allowed distance “r”, where RF exposure limits may not be exceeded, is 6.3 cm: r = √ P T / 4 π = √ 501.2/ 4 x 3.14 = 6.3 (cm). Public cannot be exposed to dangerous RF level. For SPR-2.4: P T is equal to transmitter output power 11.17 dBm plus maximum antenna gain 15 dBi, the maximum equivalent isotropically radiated power (e.i.r.p.) is 26.27 dBm = 423.6 mW. 1(mW/cm 2 ) = 423.6 mW / 4 π r 2 Allowed distance “r”, where RF exposure limits may not be exceeded, is 5.8 cm: r = √ P T / 4 π = √ 423.6/ 4 x 3.14 = 5.8(cm). Public cannot be exposed to dangerous RF level.

Test Report

This report is in conformity with ISO/IEC 17025. The A2LA logo endorsement applies only to the test methods and the standards that are listed in the scope of Hermon Laboratories accreditation. The test results relate only to the items tested. This test report must not be reproduced in any form except in full with the approval of Hermon Laboratories Ltd. Document ID: MARRAD_FCC.14551-4.doc Page 1 of 156 Date of Issue: November 01 HERMON LABORATORIES Electrical Electrical Hermon Laboratories Ltd. P.O.Box 23 Binyamina 30550, Israel Tel.+972 46288001 Fax.+972 46288277 e-mail: [email protected] ELECTROMAGNETIC EMISSIONS TEST REPORT according to FCC Part 15 subpart C, §15.247 for Marconi Communications LTD. EQUIPMENT UNDER TEST: Base Station Radio Unit of Wireless Local Loop System (WipLL), model BSR-2.4 (bit rate 4 Mbit/s) Document ID: MARRAD_FCC.14551-4.doc Page 2 of 156 Date of Issue: November 01 HERMON LABORATORIES Electrical Hermon Laboratories Ltd. P.O.Box 23 Binyamina 30550, Israel Tel.+972 46288001 Fax.+972 46288277 e-mail: [email protected] Description of equipment under test Test items Base station frequency hopping transceiver Manufacturer Marconi Communications Ltd. Types (Models) BSR-2.4 (with bit rate 4 Mbit/s) Receipt date September 5, 2001 Applicant information Applicant’s representative & responsible person Mr. Shmuel Bleichman, VP engineering Company Marconi Communications Ltd. Address 1 Hamelacha street Postal code 71293 City Lod Country Israel Telephone number +972 8977 7015 Telefax number +972 8977 7050 Test performance Project Number: 14551 Location Hermon Laboratories Test performed September 5 to September 23, 2001 Purpose of test EUT certification according to FCC requirements Test specification(s) FCC Part 15, subpart C, §15.247, §§15.205, 15.207, 15.209, subpart B §§15.107, 15.109 Document ID: MARRAD_FCC.14551-4.doc Page 3 of 156 Date of Issue: November 01 HERMON LABORATORIES Electrical Hermon Laboratories Ltd. P.O.Box 23 Binyamina 30550, Israel Tel.+972 46288001 Fax.+972 46288277 e-mail: [email protected] Contents 1 SUMMARY AND SIGNATURES...............................................................................................4 2 GENERAL INFORMATION.......................................................................................................5 2.1 A BBREVIATIONS AND ACRONYMS ...........................................................................................5 2.2 S PECIFICATION REFERENCES ................................................................................................6 2.3 EUT DESCRIPTION ...............................................................................................................6 2.4 EUT TEST CONFIGURATION ..................................................................................................7 3 TEST FACILITY DESCRIPTION ..............................................................................................8 3.1 G ENERAL .............................................................................................................................8 3.2 E QUIPMENT CALIBRATION .....................................................................................................8 3.3 S TATEMENT OF QUALIFICATION .............................................................................................9 4 EMISSION MEASUREMENTS ...............................................................................................10 4.1 F REQUENCY HOPPING CHANNELS SEPARATION AND HOPPING FREQUENCY USAGE TEST ACCORDING TO §15.247( A )(1)( III ) ......................................................................................10 4.2 O CCUPIED BANDWIDTH TEST ACCORDING TO §15.247( A )(1)( III )............................................15 4.3 T IME OF OCCUPANCY , DEFINITION ACCORDING TO § 15.247( A )(1)( III ) ...................................19 4.4 T OTAL SPAN OF HOPPING CHANNELS TEST ACCORDING TO § 15.247( A )(1)( III ).......................22 4.5 M AXIMUM PEAK OUTPUT POWER TEST ACCORDING TO §15.247 ( B )(1), (3)( I ) ........................25 4.6 B AND EDGE COMPLIANCE OF RF CONDUCTED EMISSIONS TEST ACCORDING TO §15.247( C )...30 4.7 O UT OF BAND ANTENNA CONDUCTED EMISSIONS TEST ACCORDING TO §15.247( C )................35 4.8 O UT OF BAND RADIATED EMISSIONS TEST ACCORDING TO §15.247( C ) AND § 15.205, §15.209( A ) .......................................................................................................................79 4.9 U NINTENTIONAL RADIATED EMISSIONS ( CLASS B DIGITAL DEVICE ) TEST ACCORDING TO §15.109, §15.209 ..........................................................................................................135 4.10 U NINTENTIONAL CONDUCTED EMISSIONS ( CLASS B DIGITAL DEVICE ) TEST ACCORDING TO §15.107 .........................................................................................................................147 APPENDIX A – TEST EQUIPMENT AND ANCILLARIES USED FOR TESTS ..........................153 Document ID: MARRAD_FCC.14551-4.doc Page 4 of 156 Date of Issue: November 01 HERMON LABORATORIES Electrical Hermon Laboratories Ltd. P.O.Box 23 Binyamina 30550, Israel Tel.+972 46288001 Fax.+972 46288277 e-mail: [email protected] 1 Summary and signatures The EUT, BSR-2.4 base station radio unit, was tested according to FCC part 15 subpart C, §.15.247, subpart B §§15.107, 15.109 and found to comply with the standard requirements. Test performed by: Mr. Y. Neuman, test engineer ________________________ Test report prepared by: Mr. A. Tsukerman, certification engineer ________________________ Test report approved by: Mr. M. Nikishin, EMC group leader ________________________ Dr. E. Usoskin, C.E.O. ________________________ Document ID: MARRAD_FCC.14551-4.doc Page 5 of 156 Date of Issue: November 01 HERMON LABORATORIES Electrical Hermon Laboratories Ltd. P.O.Box 23 Binyamina 30550, Israel Tel.+972 46288001 Fax.+972 46288277 e-mail: [email protected] 2 General in…

Text truncated - open the document above for the full version.

Test Report

This report is in conformity with ISO/IEC 17025. The A2LA logo endorsement applies only to the test methods and the standards that are listed in the scope of Hermon Laboratories accreditation. The test results relate only to the items tested. This test report must not be reproduced in any form except in full with the approval of Hermon Laboratories Ltd. Document ID: MARRAD_FCC.14534-4.doc Page 1 of 153 Date of Issue: November 01 Electrical HERMON LABORATORIES Hermon Laboratories Ltd. P.O.Box 23 Binyamina 30550, Israel Tel.+972 46288001 Fax.+972 46288277 e-mail: [email protected] ELECTROMAGNETIC EMISSIONS TEST REPORT according to FCC Part 15 subpart C, §15.247 for Marconi Communications LTD. EQUIPMENT UNDER TEST: Subscriber Premises Radio Unit of Wireless Local Loop System (WipLL), model SPR-2.4 (bit rate 4 Mbit/s) Document ID: MARRAD_FCC.14534-4.doc Page 2 of 153 Date of Issue: November 01 HERMON LABORATORIES Hermon Laboratories Ltd. P.O.Box 23 Binyamina 30550, Israel Tel.+972 46288001 Fax.+972 46288277 e-mail: [email protected] Description of equipment under test Test items Subscriber premises frequency hopping transceiver Manufacturer Marconi Communications Ltd. Types (Models) SPR-2.4 (with bit rate 4 Mbit/s) Receipt date September 6, 2001 Applicant information Applicant’s representative & responsible person Mr. Shmuel Bleichman, VP engineering Company Marconi Communications Ltd. Address 1 Hamelacha street Postal code 71293 City Lod Country Israel Telephone number +972 8977 7015 Telefax number +972 8977 7050 Test performance Project Number: 14534 Location Hermon Laboratories Test performed September 6 to September 23, 2001 Purpose of test EUT certification according to FCC requirements Test specification(s) FCC Part 15, subpart C, §15.247, §§15.205, 15.207, 15.209, subpart B §§15.107, 15.109 Document ID: MARRAD_FCC.14534-4.doc Page 3 of 153 Date of Issue: November 01 HERMON LABORATORIES Hermon Laboratories Ltd. P.O.Box 23 Binyamina 30550, Israel Tel.+972 46288001 Fax.+972 46288277 e-mail: [email protected] Contents 1 SUMMARY AND SIGNATURES...............................................................................................4 2 GENERAL INFORMATION.......................................................................................................5 2.1 A BBREVIATIONS AND ACRONYMS ...........................................................................................5 2.2 S PECIFICATION REFERENCES ................................................................................................6 2.3 EUT DESCRIPTION ...............................................................................................................6 2.4 EUT TEST CONFIGURATION ..................................................................................................7 3 TEST FACILITY DESCRIPTION ..............................................................................................8 3.1 G ENERAL .............................................................................................................................8 3.2 E QUIPMENT CALIBRATION .....................................................................................................8 3.3 S TATEMENT OF QUALIFICATION .............................................................................................9 4 EMISSION MEASU…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Grant Pottash(Technical Services Director)
[email protected]+1-561-443-1009Fax: +1 561 893 8671

Technical Contact

Hermon LaboratoriesEdward Usoskin
[email protected]+972 4 628 8001

Harakevet Industrial zone · Binyamina · Israel

Test Firm

Hermon Laboratories Ltd.Alexander Usoskin
[email protected]972-4628-8001Fax: 972-4628-8277

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz40.00 mW
Confidentiality
Long Term
Grant Notes
Power Output listed is Conducted. The antennas used for this transmitter must be fixed-mounted on outdoor permanent structures with a separation distance of at least 2 meters from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Airspan Networks Inc

LTE Base Station - FCC ID PIDAS1035 - Airspan Networks Inc
PIDAS1035

LTE Base Station

Sep 20, 2023

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
B42H/B43L/B48 - FCC ID PIDASPOT5410 - Airspan Networks Inc
PIDASPOT5410

B42H/B43L/B48

Jan 10, 2021

Equipment Class

CBD - Citizens Band Category A and B Devices
LTE Base Station Radio - FCC ID PIDAS1030 - Airspan Networks Inc
PIDAS1030

LTE Base Station Radio

Aug 23, 2020

Equipment Class

CBD - Citizens Band Category A and B Devices
Base station of LTE fixed cellular system - FCC ID PIDH4K25 - Airspan Networks Inc
PIDH4K25

Base station of LTE fixed cellular system

Jan 27, 2016

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
Base station of LTE fixed cellular system - FCC ID PIDAHR2500 - Airspan Networks Inc
PIDAHR2500

Base station of LTE fixed cellular system

Aug 23, 2015

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter