Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Product Name: Fast Wireless Charger Trade Name: Gigastone Model No.: WP-5210 User's manual 設備名稱:無線充電盤 型號(型式):WP-5210 單元Unit 限用物質及其化學符號 鉛Lead (Pb) 汞Mercury (Hg) 鎘Cadmium (Cd) 六價鉻 Hexavalent chromium (Cr +6 ) 多溴聯苯 Polybrominated biphenyls (PBB) 多溴二苯醚 Polybrominated diphenyl ethers (PBDE) 電路板 O O O O O O 外殼 O O O O O O 線材 O O O O O O 其它(包含 標籤及接頭 ) O O O O O O Equipment name Type designation (Type) Restricted substances and its chemical symbols Note 1:“Exceeding 0.1 wt %” and “exceeding 0.01 wt %” indicate that the percentage content of the restricted substanceexceeds the reference percentage value of presence condition. 備考1.〝超出0.1 wt %〞及〝超出0.01 wt %〞係指限用物質之百分比含量超出百分比含量基準值。 備考2.〝○〞係指該項限用物質之百分比含量未超出百分比含量基準值。 備考3.〝-〞係指該項限用物質為排除項目。 Note 2“○” indicates that the percentage content of the restricted substancedoes not exceed the percentage of reference value of presence. Note 3The “−” indicates that the restricted substance corresponds to the exemption. 「低功率電波輻射性電機管理辦法 」第十二條 經型式認證合格之低功率射頻電機,非經許可,公司、商號或使用者均不得擅自變更頻率、加大功率或變更原設計之 特性及功能。 「低功率電波輻射性電機管理辦法 」第十四條 低功率射頻電機之使用不得影響飛航安全及干擾合法通信;經發現有干擾現象時,應立即停用,並改善至無干擾時方 得繼續使用。前項合法通信,指依電信法規定作業之無線電通信。低功率射頻電機須忍受合法通信或工業、科學及醫 療用電波輻射性電機設備之干擾。 WP-5210 WP-5210 WP-5210 WP-5210 WP-5210 WP-5210 WP- 5210(IBW004) 1.12A(Max10Watt) 100x100x7mm WP-5210 WP-5210 WP-5210 WP-5210 WP-5210 WP-5210無線充電盤 WP-5210 WP-5210 WP- 5210(IBW004) WP-5210 WP-5210 WP-5210 12A (Max10Watt) 1.12A(Max10Watt) 100x100x7mm 100x100x7mm § 15.105 Information to the user. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equip ment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. This device complies with par t 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. *RF warning for Mobile device: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
SCS-F18: Project and Product Certification Representative Authorization Letter Page 1 of 2 Rev 6.0 775 Montague Expressway Milpitas, CA 95035 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Project and Product Certification Representative Authorization Letter Reason for Amendment (current / obsolete) Revision History Approved Date From To Initial Release (obsolete) 1.0 1.0 Nov-14-2006 Revised wording (obsolete) 1.0 2.0 Sept–25-2007 Updated company template (obsolete) 2.0 3.0 Jan-31-2012 Updated letter information (obsolete) 3.0 4.0 May-23-2014 Added FCC ID field (obsolete) 4.0 5.0 Sep-16-2014 Updated company name & logo (current) 5.0 6.0 Jun-27-2018 SCS-F18: Project and Product Certification Representative Authorization Letter Page 2 of 2 Rev 6.0 Gigastone Corporation ( 03/06/2020 To: BVCPS, INC. 775 Montague Expressway, Milpitas, CA 95035 USA Dear Sir/Madam, Re: Product Certification Representative Authorization Letter We, Gigastone Corporation hereby authorize Bureau Veritas Consumer Product Services, Inc. to act as a Certification Body for certifying for the following project(s): FCC ID: PLE-WP-5210 Product Description: Fast Wireless Charger Model: WP-5210 Sincerely, Client’s signature Client’s name / title Shifan Chang / Engineer Vice President Contact information / address 12F, No. 480, Rueiguang Road Neihu Distrist, Taipei 114, Taiwan, R.O.C.
SCS-F19: Confidentiality Request Letter Page 1 of 2 Rev 6.0 775 Montague Expressway Milpitas, CA 95035 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Confidentiality Request Letter Reason for Amendment (current / obsolete) Revision History Approved Date From To Initial Release (obsolete) 1.0 1.0 Nov-14-2006 Adding CFR 2.459 (obsolete) 1.0 2.0 August – 11 - 2008 Updated company template & Added text box (obsolete) 2.0 3.0 Jan-31-2012 Added IC confidentiality letter form (obsolete) 3.0 4.0 March-26-2015 Corrections to STC form. Added reference to KDB (obsolete) 4.0 5.0 Nov-19-2015 Updated company logo (current) 5.0 6.0 Jun-26-2019 SCS-F19: Confidentiality Request Letter Page 2 of 2 Rev 6.0 Gigastone Corporation ( 03/06/2020) To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD Subject: Permanent Confidentiality Request for FCC ID: PLE-WP-5210 Pursuant to sections 0.457 and 0.459 of CFR 47, we respectfully request permanent confidential treatment of the following Exhibits accompanying this application as: -Block Diagram -Schematics -Operational Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Client’s signature: Client’s name & title: Shifan Chang & Engineer Vice President Contact information / address: 12F, No. 480, Rueiguang Road Neihu Distrist, Taipei 114, Taiwan, R.O.C.
Gigastone Corporation 12F, No. 480, Rueiguang Road Neihu Distrist, Taipei 114, Taiwan, R.O.C. Date: 03/06/2020 To: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD FCC ID: PLE-WP-5210 To Whom It May Concern: This letter is to ascertain that Gigastone Corporation. Product Fast Wireless Charger, PLE- WP-5210, has been the units used for conducting FCC compliance testing, and it meets KDB 680106 D01, Clause 5(b) all 6 conditions as stated below hence PAG is not required. 1 Power transfer frequency is less that 1 MHz 2 Output power from each primary coil is less than or equal to 15 watts 3 The transfer system includes only single primary and secondary coils. This includes charging systems that may have multiple primary coils and clients that are able to detect and allow coupling only between individual pairs of coils 4 Client device is placed directly in contact with the transmitter. 5 Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion). 6 The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit. If you have any question or concerns, pls. contact us. Sincerely, Signature: Company: name: Gigastone Corporation Address : 12F, No. 480, Rueiguang Road Neihu Distrist, Taipei 114, Taiwan, R.O.C.
WH Technology Corp. Date of Issue: Jan. 15, 2020 Report No.: WH-FCC-R19122704-C Page 1/4 External Photos WH Technology Corp. Date of Issue: Jan. 15, 2020 Report No.: WH-FCC-R19122704-C Page 2/4 WH Technology Corp. Date of Issue: Jan. 15, 2020 Report No.: WH-FCC-R19122704-C Page 3/4 WH Technology Corp. Date of Issue: Jan. 15, 2020 Report No.: WH-FCC-R19122704-C Page 4/4
Product Name: Fast Wireless Charger Trade Name: Gigastone Model No.: WP-5210 Label Location B 23.114 mm x 22.764 mm 38.567 mm 38.64438.582 mm 39.008 mm SN:01948 FCC ID:PLE-WP-5210 CCAH20LP0640T4 Made in China Design in Taiwan Fast wireless charger SN:01948 FCC ID:PLE-WP-5210 CCAH20LP0640T4 Made in China Design in Taiwan Fast wireless charger
WH Technology Corp. Date of Issue: Jan. 15, 2020 Report No.: WH-FCC-R19122704-C Page 1/3 Internal Photos WH Technology Corp. Date of Issue: Jan. 15, 2020 Report No.: WH-FCC-R19122704-C Page 2/3 WH Technology Corp. Date of Issue: Jan. 15, 2020 Report No.: WH-FCC-R19122704-C Page 3/3
WH Technology Corp. Date of Issue: Jan. 15, 2020 Report No.: WH-FCC-R19122704-C1 FCC ID: PLE-WP-5210 Page 1/8 RF EXPOSURE REPORT FOR Fast Wireless Charger Model: WP-5210 Trade Mark: Gigastone Issued to Gigastone Corporation. 12F, No. 480, Rueiguang Road Neihu Distrist, Taipei 114, Taiwan, R.O.C. Issued by WH Technology Corp. Open Site No.120, Ln. 5, Hudong St., Xizhi Dist., New Taipei City 221, Taiwan (R.O.C.) EMC Test Site Xizhi Office and Lab 7F., No.262, Sec. 3, Datong Rd., Xizhi Dist., New Taipei City 221, Taiwan (R.O.C.) Tel.: +886-2-7729-7707 Fax: +886-2- 8648-1311 Note: This test refers exclusively to the test presented test model and sample. This report shall not be reproduced except in full, without the written approval of WH Technology Corp.This document may be altered or revised by WH Technology Corp.Personnel only, and shall be noted in the revision section of the document. WH Technology Corp. Date of Issue: Jan. 15, 2020 Report No.: WH-FCC-R19122704-C1 FCC ID: PLE-WP-5210 Page 2/8 TABLE OF CONTENTS --------------------------------------------------------------------------------------------------- 2 1. GENERAL INFORMATION --------------------------------------------------------------------------------------------------------- 3 1.1 TEST MODE: ------------------------------------------------------------------------------------------------------------------------ 4 1.2 DESCRIPTION OF THE TESTED SAMPLES --------------------------------------------------------------------------------------- 4 2. LIST OF TEST AND MEASUREMENT INSTRUMENTS -------------------------------------------------------------------- 5 3. METHOD OF MEASUREMENT ---------------------------------------------------------------------------------------------------- 5 3.1 APPLICABLE STANDARD ---------------------------------------------------------------------------------------------------------- 5 3.2 TEST SETUP ------------------------------------------------------------------------------------------------------------------------ 5 3.3 TEST PROCEDURE: ---------------------------------------------------------------------------------------------------------------- 5 3.4 EQUIPMENT APPROVAL CONSIDERATIONS: ----------------------------------------------------------------------------------- 6 4. TEST DATA ----------------------------------------------------------------------------------------------------------------------------- 6 TEST SETUP PHOTOS WH Technology Corp. Date of Issue: Jan. 15, 2020 Report No.: WH-FCC-R19122704-C1 FCC ID: PLE-WP-5210 Page 3/8 1. GENERAL INFORMATION Applicant : Gigastone Corporation. Address : 12F, No. 480, Rueiguang Road Neihu Distrist, Taipei 114, Taiwan, R.O.C. Manufacturer : Gigastone Corporation. Address : 12F, No. 480, Rueiguang Road Neihu Distrist, Taipei 114, Taiwan, R.O.C. EUT : Fast Wireless Charger Model Name : WP-5210 Model Differences : N/A Standard : FCC Part 1 (Section 1.1307(b), 1.1310) Receipt Date: 12/27/2019 Final Test Date: 01/15/2020 Tested by: Reviewed by: Bing Chang/ Engineer Bell Wei / Manager Designation Number: TW2954 WH Technology Corp. Date of Issue: Jan. 15, 2020 Report No.: WH-FCC-R19122704-C1 FCC ID: PLE-WP-5210 Page 4/8 1.1 TEST MODE: 115kHz 1.2 DESCRIPTION OF THE TESTED SAMPLES EUT Name : Fast Wireless Charger Model Number FCC ID Number :: WP-5210 PLE-WP-5210 Receipt Date : 12/27/2019 Input Voltage : I/P: 5Vdc, 2A; 9Vdc, 2A O/P: 5Vdc, 1.5A; 9Vdc, 1.12A 10W Max Operate Frequency : 110KHz-205KHz Antenna Type : Coil Antenna WH Technology Corp. Date of Issue: Jan. 15, 2020 Report No.: WH-FCC-R19122704-C1 FCC ID: PLE-WP-5210 Page 5/8 2. LIST OF TEST AND MEASUREMENT INSTRUMENTS Equipment Model Manufacture Last Cal. Next Cal. EMF Meter ELT-400 NARDA Oct. 22, 2019 Oct. 21, 2020 Probe E-Field EF0691 Narda Safety Test Solutions Jul. 13, 2019 Jul. 12, 2020 3. METHOD OF MEASUREMENT 3.1 APPLICABLE STANDARD According to §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. According to §1.1310 and §2.1093 RF exposure is calculated. According KDB680106 D01 RF Exposure Wireless Charging Apps v03. 3.2 TEST SETUP 3.3 TEST PROCEDURE: a. For devices designed for typical desktop applications, such a wireless charging pads, RF exposure evaluation should be conducted assuming a user separation distance 20 cm from the top, and 15cm from other directions (Left, Right, Front, Rear, Bottom). E and H field strength measurements or numerical modeling may be used to demonstrate compliance. Measurements should be made from all sides and the top of the primary/client pair, with the 15 cm measured from the center of the probe(s) to the edge of the device. WH Technology Corp. Date of Issue: Jan. 15, 2020 Report No.: WH-FCC-R19122704-C1 FCC ID: PLE-WP-5210 Page 6/8 3.4 EQUIPMENT APPROVAL CONSIDERATIONS: The EUT does comply with item 5 of KDB 680106 D01v03 (1) Power transfer frequency is less than 1 MHz. (Conform) (2) Output power from each primary coil is less than or equal to 15 watts. (Conform) (3) The transfer system includes only single primary and secondary coils. This includes charging systems that may have multiple primary coils and clients that are able to detect and allow coupling only between individual pairs of coils. (Conform) (4) Client device is placed directly in contact with the transmitter. (Conform) (5) Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion). (Intended for desk top use) (6) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit. 4. TEST DATA E-Filed Strength Charging Probe from EUT Side Test Distance (cm) Calculated Value (A/m) Calculated Value (V/m) 50% Limits Test(V/m) Limits Test (V/m) Result < 1% Battery Front 15 0.111 0…
Text truncated - open the document above for the full version.
WH Technology Corp. Date of Issue: Jan 15, 2020 Report No. : WH-FCC-R19122704-C FCC ID. : PLE-WP-5210 Page 1/25 FCC 47 CFR PART 15 SUBPART C TEST REPORT FOR Fast Wireless Charger Model : WP-5210 Trade Name: Gigastone Issued to Gigastone Corporation. 12F, No. 480, Rueiguang Road Neihu Distrist, Taipei 114, Taiwan, R.O.C. Issued by WH Technology Corp. EMC Test Site Xizhi Office and Lab 7F., No.262, Sec. 3, Datong Rd., Xizhi Dist., New Taipei City 221, Taiwan (R.O.C.) Tel.: +886-7729-7707 Fax: +886-2- 8648-1311 Note: This test refers exclusively to the test presented test model and sample. This report shall not be reproduced except in full, without the written approval of WH Technology Corp.. This document may be altered or revised by WH Technology Corp.. Personnel only, and shall be noted in the revision section of the document. WH Technology Corp. Date of Issue: Jan 15, 2020 Report No. : WH-FCC-R19122704-C FCC ID. : PLE-WP-5210 Page 2/25 1. GENERAL INFORMATION ......................................................................................................................................... 3 2. REPORT OF MEASUREMENTS AND EXAMINATIONS ....................................................................................... 4 2.1 LIST OF MEASUREMENTS AND EXAMINATIONS .................................................................................................... 4 3. TEST CONFIGURATION OF EQUIPMENT UNDER TEST ................................................................................... 5 3.1 DESCRIPTION OF THE TESTED SAMPLES ........................................................................................... 5 3.3 TEST MODE AND TEST SOFTWARE ........................................................................................................ 5 3.4 TEST METHODOLOGY & GENERAL TEST PROCEDURES ................................................................. 6 4. TEST AND MEASUREMENT EQUIPMENT ............................................................................................................... 8 4.1 CALIBRATION .................................................................................................................................................. 8 4.2 EQUIPMENT ..................................................................................................................................................... 8 5. ANTENNA REQUIREMENTS ..................................................................................................................................... 10 5.1 STANDARD APPLICABLE ........................................................................................................................... 10 5.2 ANTENNA CONSTRUCTION AND DIRECTIONAL GAIN ...................................................................... 10 6. TEST OF CONDUCTED EMISSION ......................................................................................................................... 11 6.1 TEST LIMIT ..................................................................................................................................................... 11 6.2 TEST PROCEDURES ................................................................................................................................... 11 6.3 TYPICAL TEST SETUP ................................................................................................................................ 12 6.4 TEST RESULT AND DATA .......................................................................................................................... 13 7. TEST OF RADIATED EMISSION .............................................................................................................................. 19 7.1 TEST LIMIT ........................................................................................................................................................ 19 7.2 TEST PROCEDURES ............................................................................................................................................. 19 7.3 TYPICAL TEST SETUP ......................................................................................................................................... 20 7.4 TEST RESULT AND DATA (9KHZ ~ 30MHZ) ....................................................................................................... 21 7.5 TEST RESULT AND DATA (30MHZ ~ 1GHZ, WORST EMISSIONS FOUND) ............................................................ 23 8. RESTRICTED BANDS OF OPERATION .................................................................................................................. 25 8.1 LABELING REQUIREMENT .................................................................................................................................. 25 WH Technology Corp. Date of Issue: Jan 15, 2020 Report No. : WH-FCC-R19122704-C FCC ID. : PLE-WP-5210 Page 3/25 1. GENERAL INFORMATION Applicant : Gigastone Corporation. Address : 12F, No. 480, Rueiguang Road Neihu Distrist, Taipei 114, Taiwan, R.O.C. Manufacturer/ Factory : Gigastone Corporation. Address : 12F, No. 480, Rueiguang Road Neihu Distrist, Taipei 114, Taiwan, R.O.C. EUT : Fast Wireless Charger Model Name : WP-5210 Trade Name : Gigastone Model Differences : N/A Is here with confirmed to comply with the requirements set out in the FCC Rules and Regulations Part 15 Subpart C and the measurement procedures were according to ANSI C63.10-2013. The said equipment in the configuration described in this report shows the maximum emission levels emanatin g FCC part 15 Subpart C Receipt Date : 12/27/2019 Final Test Date :01/15/2020 Tested By: Reviewed by: Jan 15, 2020 Jan 15, 2020 (Date) Bing Chang/ Engineer (Date) Bell Wei / Manager Designation Number: TW2954 WH Technology Corp. Date of Issue: Jan 15, 2020 Report No. : WH-FCC-R19122704-C FCC ID. : PLE-WP-5210 Page 4/25 2. REPORT OF MEASUREMENTS AND EXAMINATIONS 2.1 LIST OF MEASUREMEN…
Text truncated - open the document above for the full version.
WH Technology Corp. Date of Issue: July. 15, 2019 Report No.: WH-FCC-R19062401-C Page 1/3 Test Setup Photos Photograph –Conduction Emission Test Setup WH Technology Corp. Date of Issue: July. 15, 2019 Report No.: WH-FCC-R19062401-C Page 2/3 Photograph – Radiated Emission 9kHz~30MHz Test Setup WH Technology Corp. Date of Issue: July. 15, 2019 Report No.: WH-FCC-R19062401-C Page 3/3 Photograph – Radiated Emission 30MHz ~ 1000MHz Test Setup
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.11 MHz - 0.205 MHz | - |

Qi2 3in1 Wireless Charging Pad
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
15Watt Fast Charger
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Qi Travel Power Bank
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Karaoke Microphone
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Smart Box, Media Streamer, Smart Battery
Equipment Class
DTS - Digital Transmission System