PQC-MX40WLANINTELLIVUE MX40 WLAN PATIENT WORN DEVICE

Philips Medical Systems North America Co.
INTELLIVUE MX40 WLAN PATIENT WORN DEVICE - FCC ID PQC-MX40WLAN - Philips Medical Systems North America Co.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Aug 10, 2011
Application Purpose
Original Equipment
Date of Application
Aug 10, 2011
Equipment Note
INTELLIVUE MX40 WLAN PATIENT WORN DEVICE
Frequency Range
2405.00000000 - 2480.00000000
Company
Philips Medical Systems North America Co.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

IntelliVue MX40 Instructions for Use Draft Copy ii Notice Proprietary Information This document contains proprietary information, which is protected by copyright. Copyright Copyright © 2011 Koninklijke Philips Electronics N.V. All rights reserved. Reproduction in whole or in part is prohibited without the prior written consent of the copyright holder. Philips Medical Systems Nederland B.V. reserves the right to make changes in specifications and/or to discontinue any products at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication. OxiCliq ® and OxiMax ® are registered trademarks of Nellcor Incorporated. Duracell ® is a registered trademark of Procter & Gamble Incorporated. STERRAD ® is a registered trademark of Advanced Sterilization Products. GORE-TEX ® is a registered trademark of W.L. Gore & Assoc.Incorporated Tone modulation is licensed under US patent 4,653,498 from Nellcor Puritan Bennett Incorporated. Manufacturer Philips Medical Systems 3000 Minuteman Road Andover, MA 01810-1099 (978) 687-1501 Printed in USA Document number 453 564 242 441 Warranty The information contained in this document is subject to change without notice. Philips Medical Systems makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties or merchantability and fitness for a particular purpose. Philips Medical Systems shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. Draft Copy iii FCC This device complies with Part 15 and/or Part 95 of the FCC Rules. Operation is subject to the following two conditions: (1) these devices may not cause harmful interference, and (2) these devices must accept any interference received, including interference that may cause undesired operation. Changes and modifications not expressly approved by Philips Medical Systems can void your authority to operate this equipment under Federal Communications Commissions rules Printing History New editions of this document will incorporate all material updated since the previous edition. Update packages may be issued between editions and contain replacement and additional pages to be merged by a revision date at the bottom of the page. Note that pages which are rearranged due to changes on a previous page are not considered revised. The documentation printing date and part number indicate its current edition. The printing date changes when a new edition is printed. (Minor corrections and updates which are incorporated at reprint do not cause the date to change.) The document part number changes when extensive technical changes are incorporated. First Edition June 2011 Document Conventions In this guide: Warnings Warning A Warning alerts you to a potential serious outcome, adverse event or safety hazard. Failure to observe a warning may result in death or serious injury to the user or patient. Draft Copy iv Cautions Caution A Caution alerts you to where special care is necessary for the safe and effective use of the product. Failure to observe a caution may result in minor or moderate personal injury or damage to the product or other property, and possibly in a remote risk of more serious injury. Notes A Note contains additional information on the product's usage. Draft Copy Contents - 1 Contents 1. Introducing the IntelliVue MX40 1-1 MX40 Features -------------------------------------------------------------------------- 1-2 MX40 Models ---------------------------------------------------------------------------- 1-3 MX40 Compatibility -------------------------------------------------------------------- 1-4 2. Product Safety 2-1 General Safety -------------------------------------------------------------------------- 2-2 Safety Symbols & Other Marks ----------------------------------------------------- 2-4 3. Basic Operation 3-1 Controls, Indicators and Connectors ---------------------------------------------- 3-2 MX40 Controls and Indicators -------------------------------------------------- 3-2 Operating and Navigating ------------------------------------------------------------ 3-7 Power-On Self Test --------------------------------------------------------------- 3-7 Navigating --------------------------------------------------------------------------- 3-7 Selecting Display Elements ----------------------------------------------------- 3-8 Locking the Display---------------------------------------------------------------- 3-8 Measurement Area ---------------------------------------------------------------- 3-8 Measurement Area Display Configurations --------------------------------- 3-8 Connecting/Disconnecting the Patient Cable ------------------------------ 3-9 Understanding Settings -------------------------------------------------------------- 3- 10 Changing Measurement Settings --------------------------------------------- 3- 10 ECG Settings at the MX40 ----------------------------------------------------- 3- 10 Waveform Settings at the MX40 ---------------------------------------------- 3- 11 Battery Information -------------------------------------------------------------------- 3- 12 Battery Safety Information ------------------------------------------------------ 3- 12 Lithium-ion Rechargeable Battery Care ------------------------------------ 3- 13 Inserting/Removing Batteries -------------------------------------------------- 3- 14 Inserting Batteries ---------------------------------------------------------------- 3- 15 Removing the Batteries --------------------------------------------------------- 3- 16 Battery Charge Status ----------------------------------------------------------- 3- 17 Pouch Use------------------------------------------------------------------------------- 3- 19 Securing the Pouch -------------------------------------------------------------- 3- 19 Showering -----------…

Text truncated - open the document above for the full version.

External Photos

External Photos, MX40, FCC ID: PQC-MX40WLAN Front Back

Internal Photos

Internal Photos, MX40, FCC ID: PQC-MX40WLAN Component side: SpO2 board Solder Side: SpO2 board Main board Main board with SRR and WLAN SRR and WLAN Module

RF Exposure Info

Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873 COMPLIANCE WORLDWIDE INC. TEST REPORT 304-11A In Accordance with the Requirements of MPE Calculation for FCC Part 15.247, Subpart C IC RSS-210, Issue 8 Issued to Philips Medical Systems 3000 Minuteman Drive Andover, MA 01810 978-659-2800 for the Philips Telemetry System MX40 Patient Worn Monitor 2.4 GHz 802.11b/g WLAN FCC ID: PQC-MX40WLAN IC: 3549B-MX40WLAN Report Issued on August 5, 2011 Tested by This test report shall not be reproduced, except in full, without written permission from Compliance Worldwide, Inc. (603) 887 3903 Fax 887 6445 http://www.complianceworldwide.com Test Number: 304-11A Issue Date: 07/20/2011 Page 2 of 6 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873 (603) 887 3903 Fax 887 6445 http://www.cw-inc.com RF Exposure Requirements: 1.1307(b)(1) and 1.1.307(b)(2): Systems operating under the provision of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess of the Commission’s guidelines. RF Radiation Exposure Limit: 1.1310: As specified in this section, the Maximum Permissible Exposure (MPE) limit shall be used to evaluate the environmental impact of human exposure to radio frequency (RF) radiation as specified in Section 1.1307(b), except in the case of portable devices which shall be evaluated according to the provisions of Sec 2.1093 of this chapter. Test Results: Compliant. A summation of the power densities of each of the individual radios shows that the combination of the two radios are in compliance with the limit. Channel MPE Distance (cm) DUT Output Power (dBm) DUT Antenna Gain (dBi) Power Density (mW/cm2) Power Density (W/m2) Limit (mW/cm2) Result (1) (2) (3) (4) (4) (5) SRR 2.5 0.60 0.3 0.0156591 0.1565914 1.00 Compliant WLAN 2.5 13.64 1.0 0.3707075 3.7070750 1.00 Compliant SUM 2.5 N/A N/A 0.3863666 3.8636664 1.00 Compliant Test Number: 304-11A Issue Date: 07/20/2011 Page 3 of 6 7. Measurement Data for SRR Radio from Test Report #264-11R1 7.10. Public Exposure to Radio Frequency Energy Levels (15.247(i) (1.1307 (b)(1)) RSS- GEN 5.5, RSS 102 Power Density MPE Distance (cm) DUT Output Power (dBm) DUT Antenna Gain (dBi) (mW/cm2) (W/m2) Limit (mW/cm2) Channel Frequency (1) (2) (3) (4) (5) Result 2405 2.5 -5.83 0.3 0.00356 0.03565 1 Compliant 2440 2.5 -4.50 0.3 0.00484 0.04842 1 Compliant 2480 2.5 -2.23 0.3 0.00817 0.08166 1 Compliant OP + AG (4 x π x d²) PD = • PD = Power Density (mW/cm 2 ) • OP = DUT Output Power (dBm) • AG = DUT Antenna Gain (dBi) • d = MPE Distance (cm) 1. Reference CFR 2.1093(b): For purposes of this section, a portable device is defined as a transmitting device designed to be used so that the radiating structure(s) of the device is/are within 2.5 centimeters of the body of the user. 2. Section 7.4 of this test report. 3. Data supplied by the client. Antenna specification data of worst case antenna used by the DUT. 4. Power density is calculated from field strength measurement and antenna gain. 5. Reference CFR 1.1310, Table 1: Limits for Maximum Permissible Exposure (MPE), Section (B): Limits for General Population/Uncontrolled Exposure. RSS-102 Section 2.5, 2.5.1 & 2.5.2 Requirements: 2.5 - All transmitters are exempt from routine SAR and RF exposure evaluations provided that output power complies with the power levels of sections 2.5.1 or 2.5.2. If the equipment under test (EUT) meets the requirements of sections 2.5.1 or 2.5.2, applicants are only required to submit a properly signed declaration of compliance (see Annex C). 2.5.1 - SAR evaluation is required if the separation distance between the user and the radiating element of the device is less than or equal to 20 cm, except when the device operates as follows: • above 2.2 GHz and up to 3 GHz inclusively, and with output power (i.e. the higher of the conducted or radiated (e.i.r.p.) source-based, time-averaged output power) that is less than or equal to 20 mW for general public use and 100 mW for controlled use 2.5.2 - RF exposure evaluation is required if the separation distance between the user and the device’s radiating element is greater than 20 cm, except when the device operates as follows: • at or above 1.5 GHz and the maximum EIRP of the device is equal to or less than 5 W. Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873 (603) 887 3903 Fax 887 6445 http://www.cw-inc.com Test Number: 304-11A Issue Date: 07/20/2011 Page 4 of 6 7. Measurement Data (continued) for WLAN from Test Report #304-11R2 7.10. Public Exposure to Radio Frequency Energy Levels (15.247(i) (1.1307 (b)(1)) RSS- GEN 5.5, RSS 102 Power Density MPE Distance (cm) DUT Output Power (dBm) DUT Antenna Gain (dBi) (mW/cm2) (W/m2) Limit (mW/cm2) Channel Frequency (1) (2) (3) (4) (5) Result 2412 2.5 0.64 1.0 0.01858 0.18579 1 Compliant 2437 2.5 0.94 1.0 0.01991 0.19908 1 Compliant 2462 2.5 0.48 1.0 0.01791 0.17907 1 Compliant 2412 2.5 12.37 1.0 0.27671 2.76714 1 Compliant 2437 2.5 12.37 1.0 0.27671 2.76714 1 Compliant 2462 2.5 12.05 1.0 0.25706 2.57058 1 Compliant 2412 2.5 -0.87 1.0 0.01312 0.13123 1 Compliant 2437 2.5 -1.20 1.0 0.01216 0.12163 1 Compliant 2462 2.5 -1.20 1.0 0.01216 0.12163 1 Compliant 2412 2.5 13.07 1.0 0.32511 3.25111 1 Compliant 2437 2.5 13.15 1.0 0.33116 3.31155 1 Compliant 2462 2.5 13.64 1.0 0.37071 3.70708 1 Compliant Note: 802.11b and 802.11g analyzed with both energy in a 1 MHz RBW and integrated 26 dB BW power. OP + AG (4 x π x d²) PD = • PD = Power Density (mW/cm 2 ) • OP = DUT Output Power (dBm) • AG = DUT Antenna Gain (dBi) • d = MPE Distance (cm) 1. Reference CFR 2.1093(b): For purposes of this section, a portable device is defined as a transmitting device designed to be used so that the radiating structure(s) of the device is/are within 2.5 centimeters of the body of the user. 2. Section 7.4 of this test report. 3. Data supplied by the client. Antenna specification data of worst case antenna used by the DUT. 4. Power d…

Text truncated - open the document above for the full version.

Test Report

Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873 (603) 887 3903 Fax 887 6445 http://www.complianceworldwide.com COMPLIANCE WORLDWIDE INC. TEST REPORT 264-11R1 In Accordance with the Requirements of FCC PART 15.247, SUBPART C INDUSTRY CANADA RSS 210, ISSUE 8 Low Power License-Exempt Radio Communication Devices Intentional Radiators Issued to Philips Medical Systems 3000 Minuteman Drive Andover, MA 01810 978-659-2800 for the Philips Telemetry System MX40 Patient Worn Monitor 2.4 GHz Short Range Radio (SRR) FCC ID: PQC-MX40WLAN IC: 3549B-MX40WLAN Tested by This test report shall not be reproduced, except in full, without written permission from Compliance Worldwide, Inc. Test Number: 264-11R1 Issue Date: 08/01/2011 Page 2 of 30 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873 (603) 887 3903 Fax 887 6445 http://www.cw-inc.com Table of Contents 1. Scope .................................................................................................................................. 3 2 .Product Details.................................................................................................................... 3 2.1 Manufacturer ............................................................................................................................ 3 2.3 Serial Number........................................................................................................................... 3 2.4 Description................................................................................................................................ 3 2.5 Power Source ........................................................................................................................... 3 2.6 EMC Modifications.................................................................................................................... 3 3. Product Configuration ......................................................................................................... 3 3.1 Operational Characteristics & Software ................................................................................... 3 3.2 EUT Hardware.......................................................................................................................... 4 3.3 . EUT Hardware/Software/Firmware Revision Level................................................................ 4 3.4 EUT Cables/Transducers ......................................................................................................... 4 3.5 Support Equipment................................................................................................................... 4 3.6 Support Equipment Cables/Transducers ................................................................................. 4 3.7 Miscellaneous........................................................................................................................... 4 3.7 Block Diagram .......................................................................................................................... 5 4. Measurements Parameters.................................................................................................6 4.1 Measurement Equipment Used to Perform Test...................................................................... 6 4.2 Measurement & Equipment Setup ........................................................................................... 6 4.3 Measurement Procedure .......................................................................................................... 6 5. Choice of Equipment for Test Suits..................................................................................... 7 5.1 Choice of Model........................................................................................................................ 7 5.2 Presentation ............................................................................................................................. 7 5.3 Choice of Operating Frequencies.............................................................................................7 6. Measurement Summary......................................................................................................8 7. Measurement Data.............................................................................................................. 8 7.1 Antenna Requirement .............................................................................................................. 8 7.2 Minimum 6 dB Bandwidth......................................................................................................... 8 7.3 99% Bandwidth....................................................................................................................... 11 7.4 Maximum Peak Conducted Output Power ............................................................................. 13 7.5 Operation with directional antenna gains greater than 6 dBi ................................................. 16 7.6 Transmitter Spurious Radiated Emissions ............................................................................. 16 7.7 Receiver Spurious Radiated Emissions ................................................................................. 19 7.8 Band Edge Measurements.....................................................................................................22 7.9 Power Spectral Density .......................................................................................................... 25 7.10 Public Exposure to Radio Frequency Energy Levels ........................................................... 27 8. Test Setup Photographs.............................................................................................................. 28 9. Test Site Description..................................................................................................................... 30 Test Number: 264-11R1 Issue Date: 08/01/…

Text truncated - open the document above for the full version.

Test Report

Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873 (603) 887 3903 Fax 887 6445 http://www.complianceworldwide.com COMPLIANCE WORLDWIDE INC. TEST REPORT 304-11R2 In Accordance with the Requirements of FCC PART 15.247, SUBPART C INDUSTRY CANADA RSS 210, ISSUE 8 Low Power License-Exempt Radio Communication Devices Intentional Radiators Issued to Philips Medical Systems 3000 Minuteman Drive Andover, MA 01810 978-659-2800 for the Philips Telemetry System MX40 Patient Worn Monitor 2.4 GHz 802.11b/g WLAN FCC ID: PQC-MX40WLAN IC: 3549B-MX40WLAN Report Issued on August 5, 2011 Tested by This test report shall not be reproduced, except in full, without written permission from Compliance Worldwide, Inc. Test Number: 304-11R2 Issue Date: 08/05/2011 Page 2 of 42 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873 (603) 887 3903 Fax 887 6445 http://www.cw-inc.com Table of Contents 1. Scope .................................................................................................................................. 3 2 .Product Details.................................................................................................................... 3 2.1 Manufacturer ............................................................................................................................ 3 2.3 Serial Number........................................................................................................................... 3 2.4 Description................................................................................................................................ 3 2.5 Power Source ........................................................................................................................... 3 2.6 EMC Modifications.................................................................................................................... 3 3. Product Configuration ......................................................................................................... 3 3.1 Operational Characteristics & Software ................................................................................... 3 3.2 EUT Hardware.......................................................................................................................... 4 3.3 . EUT Hardware/Software/Firmware Revision Level................................................................ 4 3.4 EUT Cables/Transducers ......................................................................................................... 4 3.5 Support Equipment................................................................................................................... 4 3.6 Support Equipment Cables/Transducers ................................................................................. 4 3.7 Miscellaneous........................................................................................................................... 5 3.8 Block Diagram .......................................................................................................................... 5 4. Measurements Parameters.................................................................................................6 4.1 Measurement Equipment Used to Perform Test...................................................................... 6 4.2 Measurement & Equipment Setup ........................................................................................... 6 4.3 Measurement Procedure .......................................................................................................... 6 5. Choice of Equipment for Test Suits..................................................................................... 7 5.1 Choice of Model........................................................................................................................ 7 5.2 Presentation ............................................................................................................................. 7 5.3 Choice of Operating Frequencies.............................................................................................7 6. Measurement Summary......................................................................................................8 7. Measurement Data.............................................................................................................. 8 7.1 Antenna Requirement .............................................................................................................. 8 7.2 Minimum 6 dB Bandwidth......................................................................................................... 9 7.3 99% Bandwidth....................................................................................................................... 13 7.4 Maximum Peak Conducted Output Power ............................................................................. 17 7.5 Operation with directional antenna gains greater than 6 dBi ................................................. 22 7.6 Transmitter Spurious Radiated Emissions ............................................................................. 22 7.7 Receiver Spurious Radiated Emissions ................................................................................. 25 7.8 Band Edge Measurements.....................................................................................................28 7.9 Power Spectral Density .......................................................................................................... 33 7.10 Public Exposure to Radio Frequency Energy Levels ........................................................... 37 8. Test Setup Photographs.............................................................................................................. 40 9. Test Site Description..................................................................................................................... 41 Test Number: 304-…

Text truncated - open the document above for the full version.

Test Setup Photos

Test Number: 304-11 Issue Date: 07/20/2011 8. Test Setup Photographs 8.1. Radiated Emissions Front: Page 39 of 41 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873 (603) 887 3903 Fax 887 6445 http://www.cw-inc.com Test Number: 304-11 Issue Date: 07/20/2011 8. Test Setup Photographs 8.2. Radiated Emissions Rear: Page 40 of 41 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873 (603) 887 3903 Fax 887 6445 http://www.cw-inc.com Test Number: 264-11 Issue Date: 06/24/2011 8. Test Setup Photographs 8.1. Radiated Emissions Front: Page 27 of 29 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873 (603) 887 3903 Fax 887 6445 http://www.cw-inc.com Test Number: 264-11 Issue Date: 06/24/2011 8. Test Setup Photographs 8.2. Radiated Emissions Rear: Page 28 of 29 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873 (603) 887 3903 Fax 887 6445 http://www.cw-inc.com

Contact Information

Applicant

Delroy Smith(Principal Architect)
[email protected]1-617-798-0865Fax: 1-617-798-0865

Test Firm

Compliance Worldwide, Inc.Deb Bourbeau
[email protected]603-887-3903Fax: 603 887 6445

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.40 GHz - 2.48 GHz1.00 mW
Confidentiality
Long Term
Grant Notes
Power listed is conducted. This device is approved for operation in the Wireless Medical Telemetry Service. This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter product procedures. End-users must be provided with specific operating instructions for satisfying RF exposure compliance.

Other Applications from Philips Medical Systems North America Co.

PQC-AIM

AIM

Apr 14, 2024

Equipment Class

DTS - Digital Transmission System
Access Point - FCC ID PQC-867216A - Philips Medical Systems North America Co.
PQC-867216A

Access Point

Jan 15, 2023

Equipment Class

DTS - Digital Transmission System
2.4G Radio Module - FCC ID PQC-IITBV1 - Philips Medical Systems North America Co.
PQC-IITBV1

2.4G Radio Module

Mar 08, 2021

Equipment Class

DTS - Digital Transmission System
Intellivue MX40 1.4 GHz Patient Worn Device - FCC ID PQC-MX40SH1C4 - Philips Medical Systems North America Co.
PQC-MX40SH1C4

Intellivue MX40 1.4 GHz Patient Worn Device

Mar 31, 2014

Equipment Class

NII - Unlicensed National Information Infrastructure TX
CTG Base Station - FCC ID PQC-OBRBSBV1 - Philips Medical Systems North America Co.
PQC-OBRBSBV1

CTG Base Station

Nov 17, 2013

Equipment Class