Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Philips Medizin Systeme Boeblingen GmbH August 27, 2002 PMD Q&R Markus Stacha Tel: +49-(0)7031-463-2840 Fax: +49-(0)7031-463-2442 E-Mail: [email protected] New E-Mail as of 01-Sep-2002: [email protected] Re: Additional Exhibits to an Existing Equipment Authorization Application (Form 731) Device: Transmitters (transducers) for ‘M2720A Cordless Fetal Monitoring System - Avalon CTS’ Form 731 Confirmation No.: EA711900 FCC ID: PQCM2720A Dear Sir or Madam, The device ‘M2720A Cordless Fetal Monitoring System - Avalon CTS’ consists of the following components: - Transmitter (transducer) M2725A (Toco), - Transmitter (transducer) M2726A (ultrasound, US), - Transmitter (transducer) M2727A (ECG) - Receiver (base station) M2720A, The receiver (base station) will be operated under FCC Rule Part 15 and will be authorized under a Declaration of Conformity. The transmitters (transducers) M2725A (Toco), M2726A (ultrasound), and M2727A (ECG) which are subject of this application for a FCC certification are WMTS (608-614 MHz) devices that will be operated under FCC Rule Part 95. All three transmitters have very similar design. They contain identical RF/CPU boards and parameter specific front-end boards (Toco, US or ECG). For this reason all transmitters have the same RF behavior. In addition to the exhibits submitted on August 13, 2002 we are sending now the following documentation: 1. Internal photograph of the RF-CPU board showing its upper and bottom view (‘RFCPU_Board_bottom_top_am_PDF’). This photograph has much higher resolution than the one sent previously. 2. Internal photographs of all three transmitters/transducers M2725A Toco, M2726A ultrasound, and M2727A ECG (‘TOCO/US/ECG_open_am.JPG’) showing that all three transmitters/transducers contain respectively the same RF-CPU board and parameter dependent front-end boards. 3. Parts structure (‘PartsStructure_Tx_am.PDF) including the list of the transmitters/transducers components pointing up the identical RF-CPU board in each transmitter/transducer. If you require further information, please do not hesitate to contact us. Best regards, Markus Stacha Regulatory Affairs Engineer
Philips Medizin Systeme Boeblingen GmbH November 13, 2002 PMD Q&R Markus Stacha Tel: +49-(0)7031-463-2840 Fax: +49-(0)7031-463-2442 E-Mail: [email protected] Re: New Exhibits to an Existing Equipment Authorization Application (Form 731) Correspondence Reference No.: EA711900 Device: Transmitters (transducers) for ‘M2720A Cordless Fetal Transducer System - Avalon CTS’ FCC ID: PQCM2720A Dear Mr. Leimer, With reference to your latest e-mail dated 19-Sep-02 (see back side) we are sending you the following information and/or documentation: 1. SAR compliance. Due to the very low radiated power of the transmitter (max. 0.03 mW EIRP), the independent test house CETECOM decided that tests had not been required. This SAR compliance statement is contained in the attached test report on the transmitter on page 7. 2. Rated power output We applied for 0.1 mW radiated power. The test report has been fixed up so that you can see the detailed data concerning power output in the table on page 7 now. 3. Test Report A part of the measurements has been repeated with the final configuration and the test report has been divided into two parts. We are sending you two test reports: separate for the transmitter and for the receiver (for information). We apologize for keeping you waiting, but the test house hasn’t been able to provide the requested documentation earlier. We hope that the enclosed deliverables meet with your approval. We thank you in advance for your trouble and await your reply. Best regards, Markus Stacha Regulatory Affairs Engineer Enc.: - E-Mail from FCC (on the back side) - New test report on the transmitter (including SAR compliance statement) - New test report on the receiver E-Mail from FCC To: Markus Stacha, Philips Medizin Systeme From: Andy Leimer [email protected] FCC Application Processing Branch Re: FCC ID PQCM2720A Applicant: Philips Medical Systems North America Co. Correspondence Reference Number: 23963 731 Confirmation Number: EA711900 1) This device requires routine RF exposure evaluation. Submit a SAR Report. If the conducted power is less than 1.6 mW you can submit a letter exhibit requesting exclusion from SAR testing. You would have provide conducted power measurements to prove that you meet the criteria. Explain all circumstances. This letter would then be evaluated to determine if SAR testing is required. 2) You applied for 0.1 mW. Is this ERP or conducted. I could not determine from the report where this figure is derived. 3) The Test Report is unreadable and confusing. Some plots say "with a ferrite" and others say "without a ferrite." The test report should only contain data for the final configuration. Submit a readable Test Report showing data for the final configuration of the transmitter. The receiver should be in a separate test report. The items indicated above must be submitted before processing can continue on the above referenced application. Failure to provide the requested information within 60 days of the original e-mail date may result in application dismissal pursuant to Section 2.917 (c) and forfeiture of the filing fee pursuant to section 1.1108. DO NOT reply to this e-mail by using the Reply button. In order for your response to be processed expeditiously, you must upload your response via the Internet at www.fcc.gov, Electronic Filing, OET Equipment Authorization Electronic Filing. If the response is submitted through Add Attachments, in order to expedite processing, a message which informs the processing staff that a new exhibit has been submitted must also be submitted via Submit Correspondence. Also, please note that partial responses increase processing time and should not be submitted. Any questions about the content of this correspondence should be directed to the e-mail address listed below the name of the sender.
Philips Medizin Systeme Boeblingen GmbH November 20, 2002 PMD Q&R Markus Stacha Tel: +49-(0)7031-463-2840 Fax: +49-(0)7031-463-2442 E-Mail: [email protected] Re: Request for confidentiality Correspondence Reference No.: 24380 Device: Three transmitters (transducers) for ‘M2720A Cordless Fetal Transducer System - Avalon CTS’ FCC ID: PQCM2720A Dear Mr. Leimer, With reference to your latest e-mail dated 19-Nov-02 (see back side) we request the confidentiality for the following exhibits: Exhibit Explanation Internal photos Operational description Parts lists Schematics Philips confidential. The new product applies unique design solutions Best regards, Markus Stacha Regulatory Affairs Engineer Enc.: E-Mail from FCC (on the back side) E-Mail from FCC To: Markus Stacha, Philips Medizin Systeme From: Andy Leimer [email protected] FCC Application Processing Branch Re: FCC ID PQCM2720A Applicant: Philips Medical Systems North America Co. Correspondence Reference Number: 24380 731 Confirmation Number: EA711900 1) The confidentiality fee has been paid. However there is no letter requesting confidentiality. Please submit a signed letter requesting confidentiality. The letter should include a list of exhibits where confidentiality is required and include a brief explanation as to why confidentiality is requested. The items indicated above must be submitted before processing can continue on the above referenced application. Failure to provide the requested information within 60 days of the original e-mail date may result in application dismissal pursuant to Section 2.917 (c) and forfeiture of the filing fee pursuant to section 1.1108. DO NOT reply to this e-mail by using the Reply button. In order for your response to be processed expeditiously, you must upload your response via the Internet at www.fcc.gov, Electronic Filing, OET Equipment Authorization Electronic Filing. If the response is submitted through Add Attachments, in order to expedite processing, a message which informs the processing staff that a new exhibit has been submitted must also be submitted via Submit Correspondence. Also, please note that partial responses increase processing time and should not be submitted. Any questions about the content of this correspondence should be directed to the e-mail address listed below the name of the sender.
CETECOM ICT Services GmbH Radio Satelite Communication Untertürkheimer Straße 6-10 . D-66117 SaarbrückenTelefon: +49 (0)681 598-9100Telefax: -9075 RSC11issue test report consist of30 PagesPage 1 (30) TTI-P-G166/98-30 Accredited Bluetooth™ Test Facility (BQTF) Test report no.: 4_0602-01-03TX/02 FCC Part 15.242 / 95.1115 M2720A Avalon CTS Cordless Fetal Transducer System CETECOM – ICT Services GmbH Untertürkheimerstr. 6-10 66117 Saarbrücken, Germany Telephone: + 49 (0) 681 / 598-0 Fax: + 49 (0) 681 / 9075 BLUETOOTH is a trademark owned by Bluetooth SIG, Inc. and licensed to CETECOM CETECOM ICT Services GmbH Test report no.: 4_0602-01-03TX/02Issue Date: 11.11.2002Page 2 (30) Table of Contents 1 General information 1.1 Notes 1.2 Testing laboratory 1.3 Details of applicant 1.4 Application details 1.5 Test item 1.6 Test standards 2 Technical test 2.1 Summary of test results 2.2 Test report 1 General information 1.1 Notes The test results of this test report relate exclusively to the item tested as specified in 1.5. The test report may only be reproduced or published in full. Reproduction or publication of extracts from the report requires the prior written approval of the CETECOM ICT Services GmbH. CETECOM ICT Services GmbH Test report no.: 4_0602-01-03TX/02Issue Date: 11.11.2002Page 3 (30) 1.2Testing laboratory CETECOM ICT Services GmbH Untertürkheimer Straße 6 - 10 66117 Saarbrücken Deutschland Telefone: + 49 681 598 - 9100 Telefax : + 49 681 598 - 9075 E-mail : [email protected] Internet : www.cetecom.de Accredited testing laboratory DAR-registration number : TTI-P-G-166/98-30 Accredited Bluetooth™ Test Facility (BQTF) BLUETOOTH is a trademark owned by Bluetooth SIG, Inc. and licensed to CETECOM 1.3Details of applicant Name : Philips Medizinsysteme Böblingen GmbH Street : Hewlett-Packard-Str.2 City : D-71034 Böblingen Country : Germany Telephone : +49(0)7031 / 463-0 Telefax : +49(0)7031 / 463-2944 Contact : Mr. Hansjörg Geywitz Telephone : +49(0)7031 / 463-0 1.4Application details Date of receipt of application : 2002-07-25 Date of receipt of test item : 2002-07-25 Date of test: 2002-07-25 1.5Test item Type of equipment :Wireless medical telemetry system Type designation: M2720A Avalon CTS Cordless Fetal Transducer System consisting of three equal transmitters: M2725 Toco Transducer, M2726A US Transducer and M2727A ECG Transducer (tested) and M2720A Base Station (receiver) Product name:Avalon CTS Cordless Fetal Transducer System Additional informations: : Frequency:608.0125 – 613.9875 MHz/ 10K0F2D Channel separation:12.5 kHz we tested 608.0125 MHz, 611.0 MHz and 613.9875 MHz output power rad. max :QP: –15.4 dBm (0.03mW) / 82.1 dBμV/m at 3m EIRP Number of channels :478 (3 tested) Antenna:Printed antenna on PCB (TX) Power supply:Tx: Li-Ion rechargable battery 4.2 V 1.6Test standards FCC Part §15.242 / §95.1115 CETECOM ICT Services GmbH Test report no.: 4_0602-01-03TX/02Issue Date: 11.11.2002Page 4 (30) 2 Technical test The radiated measurements were performed vertical and horizontal over the whole frequency range.We start at 1 m high with vertical receiving antenna and rotate the dish continuously. During rotation we use the antenna lift system to vary the high from 1 to 4 m. So we find maximum radiation output. At this points we do manual remeasurements. After this we do the same measurements in horizontal position of the receiving antenna. This (horizontal and vertical) is made for all the three planes of the test sample. We use the maximum received results. The radiated power was measured by substitution method according to FCC standard. The detector function and selection of bandwidth are according ANSI C63.2-1996 / 8.2.1 and ANSI C63.4-1992 Item 4.2. Antennas are conform with ANSI C63.2-1996 item 15. 150 kHz - 30 MHz: Quasi Peak measurement, 9kHz Bandwidth, passive loop antenna. 30 MHz - 200 MHz: Quasi Peak measurement, 120KHz Bandwidth, biconical antenna 200MHz - 1GHz: Quasi Peak measurement, 120KHz Bandwidth, log periodic antenna >1GHz: Average, RBW 1MHz, VBW 10 MHz, waveguide horn 2.1Summary of test results No deviations from the technical specification(s) were ascertained in the course of the tests performed. FINAL VERDICT : PASS Technical responsibility for area of testing : 2002-11-11RSC8412Hausknecht D. DateSectionNameSignature 2002-11-11RSC8414Ames H. DateSectionNameSignature CETECOM ICT Services GmbH Test report no.: 4_0602-01-03TX/02Issue Date: 11.11.2002Page 5 (30) 2.2Testreport TEST REPORT FCC Part 15.242 / 95.1115 Testreport no.: 4_0602-01-03TX/02 CETECOM ICT Services GmbH Test report no.: 4_0602-01-03TX/02Issue Date: 11.11.2002Page 6 (30) TEST REPORT REFERENCE LIST OF MEASUREMENTS The list of measurements called for in FCC Part 15.242 / 95.1115 is given below. ParagraphPARAMETER TO BE MEASUREDPAGE Transmitter parameters § 15.242/95.1115Field strength - Radiated7 § 15.242/95.1115Spurious radiations - Radiated 7 SAR statement7 § 95.1115Channel use 20 Test equipment listing21 Photographs of the equipment23 CETECOM ICT Services GmbH Test report no.: 4_0602-01-03TX/02Issue Date:11.11.2002Page 7 (30) TRANSMITTER FIELD STRENGTH and OUTPUT POWERFCC Part15.242/95.1115 RADIATED TX: M2727A ECG-Transducer FIELD STRENGTH (μV/m) low channelmid channelhigh channel f (MHz) DetectorLevel dBμV/m f (MHz) Detect or Level dBμV/m f (MHz) DetectorLevel dBμV/m 608.0125 Carrier QP82.1611.0 Carrier QP80.0613.9875 Carrier QP80.9 128.5QP39.5126.8QP40.2141.5QP39.9 1217AV48.41222AV51.91229AV49.2 1824AV35.31833AV40.21844AV37.4 2433AV43.92444AV44.02456AV37.7 4864AV19.23055AV40.6 carrierQP -15.4 dBm EIRP carrierQP -17.5 dBm EIRP carrierQP -16.6 dBm EIRP 0.03mW EIRP 0.02 mW EIRP 0.02 mW EIRP Measurement uncertainty±3 dB f < 1 GHz : RBW/VBW: 100 kHz f ≥ ≥≥ ≥ 1GHz : RBW/VBW: 1 MHz Limit for carrier: 106 dBμV/m at 3m distance QP. (Part 95) Limit for spurious:46 dBμV/m at 3m distance QP below 960 MHz. (Part 95) Limit for spurious:54 dBμV/m at 3m distance AV above 960 MHz. (Part 95) Limit for carrier: 106 dBμV…
Text truncated - open the document above for the full version.
CETECOM ICT Services GmbH Radio Satelite Communication Untertürkheimer Straße 6-10 . D-66117 SaarbrückenTelefon: +49 (0)681 598-9100Telefax: -9075 RSC11issue test report consist of22 PagesPage 1 (22) TTI-P-G166/98-30 Accredited Bluetooth™ Test Facility (BQTF) Test report no.: 4_0602-01-03RX/02 FCC Part 15.109 / 95.1115 Avalon CTS Cordless Fetal Transducer System M2720A Base station (receiver) CETECOM – ICT Services GmbH Untertürkheimerstr. 6-10 66117 Saarbrücken, Germany Telephone: + 49 (0) 681 / 598-0 Fax: + 49 (0) 681 / 9075 BLUETOOTH is a trademark owned by Bluetooth SIG, Inc. and licensed to CETECOM CETECOM ICT Services GmbH Test report no.: 4_0602-01-03RX/02Issue Date: 11.11.2002Page 2 (22) Table of Contents 1 General information 1.1 Notes 1.2 Testing laboratory 1.3 Details of applicant 1.4 Application details 1.5 Test item 1.6 Test standards 2 Technical test 2.1 Summary of test results 2.2 Test report 1 General information 1.1 Notes The test results of this test report relate exclusively to the item tested as specified in 1.5. The test report may only be reproduced or published in full. Reproduction or publication of extracts from the report requires the prior written approval of the CETECOM ICT Services GmbH. CETECOM ICT Services GmbH Test report no.: 4_0602-01-03RX/02Issue Date: 11.11.2002Page 3 (22) 1.2Testing laboratory CETECOM ICT Services GmbH Untertürkheimer Straße 6 - 10 66117 Saarbrücken Deutschland Telefone: + 49 681 598 - 9100 Telefax : + 49 681 598 - 9075 E-mail : [email protected] Internet : www.cetecom.de Accredited testing laboratory DAR-registration number : TTI-P-G-166/98-30 Accredited Bluetooth™ Test Facility (BQTF) BLUETOOTH is a trademark owned by Bluetooth SIG, Inc. and licensed to CETECOM 1.3Details of applicant Name : Philips Medizinsysteme Böblingen GmbH Street : Hewlett-Packard-Str.2 City : D-71034 Böblingen Country : Germany Telephone : +49(0)7031 / 463-0 Telefax : +49(0)7031 / 463-2944 Contact : Mr. Hansjörg Geywitz Telephone : +49(0)7031 / 463-0 1.4Application details Date of receipt of application : 2002-07-25 Date of receipt of test item : 2002-07-25 Date of test: 2002-07-25 1.5Test item Type of equipment :Wireless medical telemetry system Type designation: M2720A Base station (receiver) Manufacturer:- applicant - Street: City: Country: Serial number: Additional informations: : Frequency:608.0125 – 613.9875 MHzChannel separation:12.5 kHz Number of channels :478 Antenna:rod antenna with BNC connector Power supply:Rx: 100 - 240V AC (110V tested) 1.6Test standards FCC Part §15.109 / §95.1115 CETECOM ICT Services GmbH Test report no.: 4_0602-01-03RX/02Issue Date: 11.11.2002Page 4 (22) 2 Technical test The radiated measurements were performed vertical and horizontal over the whole frequency range.We start at 1 m high with vertical receiving antenna and rotate the dish continuously. During rotation we use the antenna lift system to vary the high from 1 to 4 m. So we find maximum radiation output. At this points we do manual remeasurements. After this we do the same measurements in horizontal position of the receiving antenna. This (horizontal and vertical) is made for all the three planes of the test sample. We use the maximum received results. The radiated power was measured by substitution method according to FCC standard. The detector function and selection of bandwidth are according ANSI C63.2-1996 / 8.2.1 and ANSI C63.4-1992 Item 4.2. Antennas are conform with ANSI C63.2-1996 item 15. 150 kHz - 30 MHz: Quasi Peak measurement, 9kHz Bandwidth, passive loop antenna. 30 MHz - 200 MHz: Quasi Peak measurement, 120KHz Bandwidth, biconical antenna 200MHz - 1GHz: Quasi Peak measurement, 120KHz Bandwidth, log periodic antenna >1GHz: Average, RBW 1MHz, VBW 10 MHz, waveguide horn 2.1Summary of test results The receiver is able to receive parallel on three different frequencies. So we have got only one plot for receiving mode. No deviations from the technical specification(s) were ascertained in the course of the tests performed. FINAL VERDICT : PASS Technical responsibility for area of testing : 2002-08-01RSC8412Hausknecht D. DateSectionNameSignature 2002-08-01RSC8414Ames H. DateSectionNameSignature CETECOM ICT Services GmbH Test report no.: 4_0602-01-03RX/02Issue Date: 11.11.2002Page 5 (22) 2.2Testreport TEST REPORT FCC Part 15.109 / 95.1115 Testreport no.: 4_0602-01-03RX/02 CETECOM ICT Services GmbH Test report no.: 4_0602-01-03RX/02Issue Date: 11.11.2002Page 6 (22) TEST REPORT REFERENCE LIST OF MEASUREMENTS The list of measurements called for in FCC Part 15.109 / 95.1115 is given below. ParagraphPARAMETER TO BE MEASUREDPAGE Receiver parameters § 15.109Spurious radiations - Radiated7 Test equipment listing12 Photographs of the equipment14 CETECOM ICT Services GmbH Test report no.: 4_0602-01-03RX/02Issue Date: 11.11.2002Page 7 (22) Equipment under test : M2720A Base station (receiver) Ambient temperature : 22.9° °° °C Relative humidity : 35 % RECEIVER SPURIOUS RADIATION § 15.109 All measured peaks were > 10 dB peak below limit. We remeasured two frequencies, 122.7 MHz and 217.1 MHz with CISPR QP Detector. Results: 122.7 MHz peak:12.3 dBμV/m QP:9.3 dBμV/m cor. 3 to 10m :10.5 dB =19.8 dBμV/m 217.1 MHz peak:9.2 dBμV/m QP:8.1 dBμV/m cor. 3 to 10m :10.5 dB =18.6 dBμV/m Both results are far below limit. Plots see next pages. CETECOM ICT Services GmbH Test report no.: 4_0602-01-03RX/02Issue Date: 11.11.2002Page 8 (22) Equipment under test : M2720A Base station (receiver) Ambient temperature : 22.9° °° °C Relative humidity : 35 % RECEIVER SPURIOUS RADIATION § 15.109 RADIATED 30 – 200 MHz vertical RES BW 1 MHzVBW 1 MHzSWP 2.0 3 sec ATTEN0 dBREF 77.0 dBuV 10 dB/ POS PK START 25 MHzSTOP 20 3 MHz OFFSET -2 0 . 0 dB MKR 122.7 MHz 12.30 dBuV * FCC Part 15 Cl.B 10 m Fa.: Phillips Medizinsysteme Type: Mode:RX GNr:4-0602-1-1/02 CETECOM ICT SERVICES This plot shows peak values and the limit according to FCC15.109 at 10m distance. We made additional measurements with CISPR QP Dete…
Text truncated - open the document above for the full version.
Hewlett-Packard-Str. 2 · Boeblingen · Germany
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 1 | 95H | 608.0125 MHz - 613.9875 MHz | 100.00 µW | 10K0F2D | 2.5000000000 ppm |
AIM
Equipment Class
DTS - Digital Transmission System
Access Point
Equipment Class
DTS - Digital Transmission System
2.4G Radio Module
Equipment Class
DTS - Digital Transmission System
Intellivue MX40 1.4 GHz Patient Worn Device
Equipment Class
NII - Unlicensed National Information Infrastructure TX
CTG Base Station
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter