Savant Technologies LLC, dba GE Lighting, a Savant company 1975 Noble Road, East Cleveland, OH 44112 USA 1/11/2023 Nemko North America, Inc. 303 River Road Ottawa, Ontario, Canada K1V 1H2 AUTHORITY TO ACT AS AGENT - FCC On our behalf, I appoint Audix Technology (Shanghai) Co., Ltd., to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in FCC regulations will have affixed to it a label identical to that submitted for approval with this application. In signing this letter, Applicant certifies that neither the applicant nor any party to the application is not subject to a denial of Federal benefits, that include FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. § 862 because of a conviction for possession or distribution of a controlled substance. See 47 CFR 1.2002(b) for the definition of a "party" for these purposes. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, as specified by Nemko North America Inc., still resides still resides with us. Sincerely, Printed name: Paul Smith
Savant Technologies LLC, dba GE Lighting, a Savant company 1975 Noble Road, East Cleveland, OH 44112 USA 1/11/2023 Nemko North America, Inc. 303 River Road Ottawa, Ontario, Canada K1V 1H2 REQUEST FOR CONFIDENTIALITY - FCC FCC ID: PUU-A19-DMFCVI Pursuant to Sections 0.457(d)(1)(ii) and 0.459 of the Commission’s Rules and FCC Guidance document 726920, we hereby request confidential treatment of information accompanying this application as outlined below: PERMANENT LONG-TERM CONFIDENTIALITY: Schematics Bill of Materials/Parts List Block Diagrams Theory of Operation SHORT TERM CONFIDENTIALITY FOR A PERIOD OF 0 DAYS (Note: for the X number of days, you can list up to 180 days, but should not go past the date you start product marketing/sale): When the device is marketed before the requested number of days listed above, the grantee will inform the TCB to release the Short-Term Confidentiality information withheld on the FCC equipment authorization website. The above information contains trade secrets and proprietary information not customarily released to the public. The public disclosure of this information might be harmful to the applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457(d)(1)(ii), disclosure of this Application and all accompanying materials will not be made before the date of the Grant for this Application. Sincerely, Signed: Printed name: Paul Smith Title: Lead Systems Engineer – Safety & Regulatory
Savant Technologies LLC, dba GE Lighting, a Savant company 1975 Noble Road, East Cleveland, OH 44112 USA Family Certification Attestation Letter 1/12/2023 Nemko Canada Inc 303 River Road Ottawa K1V 1H2 Canada ATTN.: Reviewing Engineer IC: 10798A-DMFCA19VI HVINs/Models: CLEDA199CD1E, CLEDA199CDRVB We hereby request Family Certification for the above mentioned HVINs/Models based on them being electrically identical. The CLEDA199CD1E and CLEDA199CDRVB are the same except for Model Name as sale purpose. Signed: Printed name: Paul Smith Title: Lead Systems Engineer – Safety & Regulatory Date: 1/12/2023
Appendix II Page 2 of 7 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F23003 FIGURE 1 D IRECT CONNECT FULL COLOR A19 (M/N: CLEDA199CD1) GENERAL VIEW FIGURE 2 DIRECT CONNECT FULL COLOR A19 (M/N: CLEDA199CD1) B ACK VIEW
FCCID:PUU-A19-DMFCVI IC:10798A-DMFCA19VI ICHVIN:CLEDA199CD1E MADE IN CHINAYYDDDFL GM Full Color A19-Single chip 2022.12.07 V1.0 9.5W 0.11A 120V 60Hz 2000K-7000K CLEDA199CD1 1 7mm. 2.3mm LED LAMP 4US7 LNT 4. YYDDDFL GM为批次信息,需逐单替换, 字体:Arial narrow, 字号5pt 1234 567 8910 12mm ±0.5mm QR-code manual-code 1、QR-code为一灯一码在数据库上获取, Module Size 25*25,纠错等级Q 25%。 2、manual-code在数据库上获取,使用CSA Digits font字体, 字体最少6pt 3、图标数字和二维码等宽。
FCCID:PUU-A19-DMFCVI IC:10798A-DMFCA19VI ICHVIN:CLEDA199CDRVB MADE IN CHINA YYDDDFL GM Full Color A19-Single chip 2022. 12.08 V1.1 9.5W 0.11A 120V 60Hz 2000K-7000K CLEDA199CDRV 1 7mm. 2.3mm LED LAMP 4US7 LNT 4.YYDDDFL GM为批次信息,需逐单替换, 字体:Arial narr ow, 字号5pt 1234 567 8910 12mm ±0.5mm QR-code manual-code 1、QR-code为一灯一码在数据库上获取, Module Size 25*25,纠错等级Q 25%。 2、manual-code在数据库上获取, 使用CSA Digits font字体,字体最少6pt 3、图标数字和二维码等宽。
Appendix II Page 3 of 7 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F23003 FIGURE 3 D IRECT CONNECT FULL COLOR A19 (M/N: CLEDA199CD1) COVER REMOVED FIGURE 4 DIRECT CONNECT FULL COLOR A19 (M/N: CLEDA199CD1) LED FRONT Appendix II Page 4 of 7 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F23003 FIGURE 5 D IRECT CONNECT FULL COLOR A19 (M/N: CLEDA199CD1) LED BACK FIGURE 6 DIRECT CONNECT FULL COLOR A19 (M/N: CLEDA199CD1) M AINBOARD FRONT Appendix II Page 5 of 7 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F23003 FIGURE 7 D IRECT CONNECT FULL COLOR A19 (M/N: CLEDA199CD1) MAINBOARD BACK FIGURE 8 DIRECT CONNECT FULL COLOR A19 (M/N: CLEDA199CD1) R FBOARD FRONT Appendix II Page 6 of 7 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F23003 FIGURE 9 D IRECT CONNECT FULL COLOR A19 (M/N: CLEDA199CD1) RFBOARD BACK FIGURE 10 DIRECT CONNECT FULL COLOR A19 (M/N: CLEDA199CD1) C HIP&CRYSTAL ON BOARD Appendix II Page 7 of 7 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F23003 FIGURE 11 D IRECT CONNECT FULL COLOR A19 (M/N: CLEDA199CD1) ANTENNA Antenna
Applicant: Savant Technologies LLC, dba GE Lighting, a Savant company Product Name: Direct Connect Full Color A19 Model Number: CLEDA199CD1, CLEDA199CDRV FCC ID: PUU-A19-DMFCVI RADIO FRREQUENCY EXPOSURE COMPLIANCE RESULT: Te s t Standard: FCC CFR 47 §1.1310 : Radiofrequency radiation exposure limits. Note: (1) Occupational/controlled exposure limits apply in situations in which persons are exposed as a consequence of their employment provided those persons are fully aware of the potential for exposure and can exercise control over their exposure. Limits for occupational/controlled exposure also apply in situations when a person is transient through a location where occupational/controlled limits apply provided he or she is made aware of the potential for exposure. (2) General population/uncontrolled exposure limits apply in situations in which the general public may be exposed, or in which persons who are exposed as a consequence of their employment may not be fully aware of the potential for exposure or cannot exercise control over their exposure. MPE Calculation Standard: MPE(S) = PG/(4휋푅 2 ) where: S = power density (in appropriate units, e.g. mW/ cm 2 ) P = power input to the antenna (in appropriate units, e.g., mW) G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna (appropriate units, e.g., cm) Calculation Result: For this EUT, General population/uncontrolled exposure limits applied. The limit value 1.0mW/cm 2 is available for this EUT. Modulation Peak Output Power Antenna Gain MPE Limit Verdict (dBm) (mW) (dBi) (Numeric) (mW/cm 2 ) (mW/cm 2 ) BLE 6.795 4.78079 0.5 1.12202 0.00107 1.0 Compliant 802.11b 15.78 37.8443 0.5 1.12202 0.00845 1.0 Compliant 802.11g 15.12 32.5087 0.5 1.12202 0.00726 1.0 Compliant 802.11n20 14.03 25.293 0.5 1.12202 0.00565 1.0 Compliant 802.11n40 13.31 21.4289 0.5 1.12202 0.00478 1.0 Compliant For R = 20cm
Savant Technologies LLC, dba GE Lighting, a Savant company FCC ID: PUU-A19-DMFCVI Page 1 of 45 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F23003 Prepared For: Savant Technologies LLC, dba GE Lighting, a Savant company 1975 Noble Road, Cleveland, OH 44112 Prepared By: Audix Technology (Shanghai) Co., Ltd. 3F and 4F, 34Bldg, 680 Guiping Rd., Caohejing Hi-Tech Park, Shanghai 200233, China Tel: +86-21-64955500 File No. : C1D2211043 Report No. : ACI-F23003 Date of Test : 2022.12.18-2023.01.10 Date of Report : 2023.01.17 TEST REPORT On behalf of Savant Technologies LLC, dba GE Lighting, a Savant company Product Name: Direct Connect Full Color A19 Model No.: CLEDA199CD1, CLEDA199CDRV FCC ID: PUU-A19-DMFCVI The statement is based on a single evaluation of one sample of the above-mentioned products. It does not imply an assessment of the whole production and does not permit the use of the test lab logo. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. TESTING NVLAP LAB CODE 200371-0 Savant Technologies LLC, dba GE Lighting, a Savant company FCC ID: PUU-A19-DMFCVI Page 2 of 45 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F23003 TABLE OF CONTENTS Page 1 SUMMARY OF STANDARDS AND RESULTS .......................................................................... 5 1.1 Description of Standards and Results ......................................................................................... 5 2 GENERAL INFORMATION .......................................................................................................... 6 2.1 Description of Equipment Under Test ........................................................................................ 6 2.2 EUT Specifications Assessed in Current Report ........................................................................ 7 2.3 Test Information ......................................................................................................................... 7 2.4 Sample Description .................................................................................................................... 7 2.5 Supported equipment .................................................................................................................. 8 2.6 Description of Test Facility ........................................................................................................ 8 3 CONDUCTED EMISSION TEST .................................................................................................. 9 3.1 Test Equipment ........................................................................................................................... 9 3.2 Block Diagram of Test Setup ..................................................................................................... 9 3.3 Conducted Emission Limits (§15.207) ..................................................................................... 10 3.4 Test Configuration .................................................................................................................... 10 3.5 Operating Condition of EUT .................................................................................................... 10 3.6 Test Procedures ........................................................................................................................ 10 3.7 Test Results .............................................................................................................................. 11 4 RADIATED EMISSION TEST ..................................................................................................... 13 4.1 Test Equipment ......................................................................................................................... 13 4.2 Block Diagram of Test Setup ................................................................................................... 13 4.3 Radiated Emission Limit (§15.209) ......................................................................................... 14 4.4 Test Configuration .................................................................................................................... 14 4.5 Operating Condition of EUT .................................................................................................... 15 4.6 Test Procedures ........................................................................................................................ 15 4.7 Test Results .............................................................................................................................. 16 5 6 DB BANDWIDTH MEASUREMENT ...................................................................................... 22 5.1 Test Equipment ......................................................................................................................... 22 5.2 Block Diagram of Test Setup ................................................................................................... 22 5.3 Specification Limits (§15.247(a)(2)) ........................................................................................ 22 5.4 Operating Condition of EUT .................................................................................................... 22 5.5 Test Procedure .......................................................................................................................... 22 5.6 Test Results .............................................................................................................................. 23 6 MAXIMUM PEAK OUTPUT POWER MEASUREMENT ...................................................... 26 6.1 Test Equipment ......................................................................................................................... 26 6.2 Block Diagram of Test Setup ...................................................................…
Text truncated - open the document above for the full version.
GENERAL INFORMATION Manufacturer: Savant Technologies LLC, dba GE Lighting, a Savant company Address: 1975 Noble Road, Cleveland, OH 44112 Name: JXC32-18 ANTENNA SPECIFICATIONS Item Specifications Antenna Frequency Range 2400~2483.5MHz Polarization Linear Peak Gain 0.5dBi V.S.W.R <2.0 Impedance 50Ω Return Loss -10dB Connector PCB Efficiency 25% Environmental Operating Temperature -10°C~+60°C ANTENNA PATTERN Antenna Picture:
Savant Technologies LLC, dba GE Lighting, a Savant company FCC ID: PUU-A19-DMFCVI Page 1 of 92 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F23004 Prepared For: Savant Technologies LLC, dba GE Lighting, a Savant company 1975 Noble Road, Cleveland, OH 44112 Prepared By: Audix Technology (Shanghai) Co., Ltd. 3F and 4F, 34Bldg, 680 Guiping Rd., Caohejing Hi-Tech Park, Shanghai 200233, China Tel: +86-21-64955500 File No. : C1D2211043 Report No. : ACI- F23004 Date of Test : 2022.12.18-2023.01.08 Date of Report : 2023.01.17 TEST REPORT On behalf of Savant Technologies LLC, dba GE Lighting, a Savant company Product Name: Direct Connect Full Color A19 Model No.: CLEDA199CD1, CLEDA199CDRV FCC ID: PUU-A19-DMFCVI The statement is based on a single evaluation of one sample of the above-mentioned products. It does not imply an assessment of the whole production and does not permit the use of the test lab logo. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NI S T, or any agency of the Federal Government. TESTING NVLAP LAB CODE 200371-0 Savant Technologies LLC, dba GE Lighting, a Savant company FCC ID: PUU-A19-DMFCVI Page 2 of 92 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F23004 TABLE OF CONTENTS Page 1 SUMMARY OF STANDARDS AND RESULTS .......................................................................... 5 1.1 Description of Standards and Results ......................................................................................... 5 2 GENERAL INFORMATION .......................................................................................................... 6 2.1 Description of Equipment Under Test ........................................................................................ 6 2.2 EUT Specifications Assessed in Current Report ........................................................................ 7 2.3 Test Information ......................................................................................................................... 7 2.4 Sample Description .................................................................................................................... 7 2.5 Supported equipment .................................................................................................................. 8 2.6 Description of Test Facility ........................................................................................................ 8 3 CONDUCTED EMISSION TEST .................................................................................................. 9 3.1 Test Equipment........................................................................................................................... 9 3.2 Block Diagram of Test Setup ..................................................................................................... 9 3.3 Conducted Emission Limits (§15.207) ..................................................................................... 10 3.4 Test Configuration .................................................................................................................... 10 3.5 Operating Condition of EUT .................................................................................................... 10 3.6 Test Procedures ........................................................................................................................ 10 3.7 Test Results .............................................................................................................................. 11 4 RADIATED EMISSION TEST ..................................................................................................... 13 4.1 Test Equipment......................................................................................................................... 13 4.2 Block Diagram of Test Setup ................................................................................................... 13 4.3 Radiated Emission Limit (§15.209) ......................................................................................... 14 4.4 Test Configuration .................................................................................................................... 14 4.5 Operating Condition of EUT .................................................................................................... 15 4.6 Test Procedures ........................................................................................................................ 15 4.7 Test Results .............................................................................................................................. 16 5 99% OCCUPIED BANDWIDTH MEASUREMENT ................................................................ 30 5.1 Test Equipment......................................................................................................................... 30 5.2 Block Diagram of Test Setup ................................................................................................... 30 5.3 Operating Condition of EUT .................................................................................................... 30 5.4 Test Procedure .......................................................................................................................... 30 5.5 Test Results .............................................................................................................................. 31 6 6 DB BANDWIDTH MEASUREMENT ...................................................................................... 38 6.1 Test Equipment......................................................................................................................... 38 6.2 Block Diagram of Test Setup ................................................................................................... 38 6.3 Specification Limits (§15.247(a)(2)) ..................................................…
Text truncated - open the document above for the full version.
Appendix I Page 2 of 4 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F23003 Test Set-Up Photos 1. Conducted Te s t Appendix I Page 3 of 4 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F23003 2. Radiated Test (BELOW 1GHZ) (ABOVE 1GHZ) Appendix I Page 4 of 4 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F23003 3. Antenna-port Conducted Test
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15C | 2.41 GHz - 2.46 GHz | 37.84 mW |

Dual sockets indoor plug
Equipment Class
DTS - Digital Transmission System
CYNC Shoplight
Equipment Class
DTS - Digital Transmission SystemCync Direct Connect Strip
Equipment Class
DTS - Digital Transmission SystemPROSEO Sage LF module
Equipment Class
DTS - Digital Transmission System
Fan Switch
Equipment Class
DTS - Digital Transmission System