
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
PK-00116133-1 Let's Get Started Scan QR code to download the Cync app and compl ete set up: Enable all Cync features Get Started With Cync Plug in and power on your Smart Plug. Fo r se t up hel p, visi t support.gelighting.com or call 1-844-302-2943 Indoor 2-Outlet Smart Plug Quick Start Setup Guide FC C Compliance Statement Compliance Notice: • Reorient or relocate the receiving antenna. • Increase th e separation between the equi pment and receiver. • Connect the equi pment into an outlet on a circuit different from that to which the receiver is connected. • Consult th e deale r or an experienced radio/TV technician fo r help. 1. This device may not caus e harmful interference. 2. This device must accept any interference received, including interference that may caus e undesired operation. Changes or modifications that are not expressly approved by the manufacturer could voi d the user’s authority to operate the equi pment. To comply with FCC and (ISED) Canada RF exposure compliance requirements, the device should be located at a distance of at least 20 cmfrom all persons during normal operation. The antennas used for this product must not be co-located or operated in conjunctionwith any other antenna or transmitter. Le dispositif doit être placé à une distance d’au moins 20 cm à partir de toutes les personnes au cours de son fonctionnementnormal. Les antennes utilisées pour ce produit ne doivent pas être situés ou exploités conjointement avec une autre antenne outransmetteur. CAUTION - High Voltage - Disconnect pow er supply before servicing Operation temperature: 0-40°C Type 1 Enclosure IP20 Pollution Degree 2 Impulse Voltage: 1500V Type 1. B action Use the indoor plug only in conjunction with 15A circuit breakers. Ind oo r us e only. Cync Matter Savant Set schedules & control away from home Connect to Amazon Alexa & Google Assistant Connect to Apple Home & Samsung SmartThings Personalized app experience 3 Ways to Get Started Please note: You may see a “s et up using Matter” noti fication on your phone. To set up in th e Cync App, powered by Savant, dismiss the notification. Like your new Smart Plug? Share your experience! Leave a review where you purchased the product. Enhance your smart home experience Left Outlet On/Off Button USB-C Port USB-A Port Outlet Status Indicator Right Outlet On/Off Button Get Started With SavantDevice Control & Charging To learn more about Savant, visit ww w.savant.com Connect with othe r smart products Get Started With Matter If you already have Cync devices in the Cync App, add your new device to the Cync App, then enable your voice assistant. Plug in and power on your Smart Plug. Open your preferred smart home app: • Google Home • Samsung SmartThings • Amazon Alexa • Apple Home and scan the Matter QR code or enter the 11-digit code on the device sticker to compl ete setup. You’ve chosen a great way to make your home more comfortable, convenient and easier to control. Select the set up option that works best for you: 1. Cync App Setup Use the Cync app to connect and control all your Cync smart home products in one place and access the full range of features. 2. Matter Setup Connect with Matter to easily work with compatible smart home devices and platforms across your home. 3. Savant App Setup Unlock enhanced features and connect to more smart home devices using the Savant App (hub required and sold separately). The quick start guide can help you choose the one that works best for your home. Charge phones and tablets using the USB ports. • USB-A output: up to 12W • USB-C output: up to 15W • USB charging ports remain powered even when the outlets are turned off. Plug Reset: Cync app: Press and hold either On/Off Button until the LED indicator turns red. Savant app: Press and hold either On/Off Button until the LED indicator alternates red and green. Upgrade to the Savant app*. Unify your connected environment into one integrated experience controlled by intuitive, award-winning software, including: • Lighting • Climate • Entertainment • Security Scan to learn more about the Savant Smart Home experience. *Requires hub/host (sold separately). Enhanced control, connectivity & compatibility Use of the Works with Apple badge means that an accessory has been designed to work specifically with the technology identified in the badge and has been certified by the developer to meet Apple’s performance standards. Apple is not responsible for the operation of this device or its compliance with safety and regulatory standards. Works with Apple Home logo™ is a trademark of Apple Inc. Amazon, Alexa and all related logos are trademarks of Amazon.com, Inc. or its affiliates. Google, Android, and Google Home are trademarks of Google LLC. GE is a trademark of General Electric Company, used under trademark license. This device complies with FCC Rules Part 15 and with Innovation, Science and Economic Development (ISED) Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: Le présent appareil est conforme aux FCC Règles Partie 15 et CNR d’Innovation, Sciences et Développement économique (ISDE) Canada applicables aux appareils radio exempts de licence. L’exploitationest autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doitaccepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interferen…
Text truncated - open the document above for the full version.
Savant Technologies LLC, dba GE Lighting, a Savant company 1975 Noble Road, East Cleveland, OH 44112 USA Covered Equipment Certification Attestation Letter 6/10/2026 Nemko North America, Inc. 303 River Road Ottawa K1V 1H2 Canada ATTN.: Reviewing Engineer FCC ID: PUU-CPLGID2BLW1 Savant Technologies LLC, dba GE Lighting, a Savant company (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Note: If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, the applicant should include an explanation on why the equipment is not “covered” equipment. Savant Technologies LLC, dba GE Lighting, a Savant company (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Savant Technologies LLC, dba GE Lighting, a Savant company (“the applicant”) certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Signed: Printed name: Paul Smith Title: Lead Systems Engineer – Safety & Regulatory Company Name: Savant Technologies LLC, dba GE Lighting, a Savant company Date: 7/7/2026
Savant Technologies LLC, dba GE Lighting, a Savant company 1975 Noble Road, East Cleveland, OH 44112 USA * the applicant must designate a contact located in the United States for purposes of acting as the applicant’s agent for service of process, regardless of whether the applicant is a domestic or foreign entity. An applicant located in the United States may designate itself as the agent for service of process. U.S. Agent Designation for Service of Process - Certification Attestation Letter 6/10/2026 Nemko North America, Inc. 303 River Road Ottawa K1V 1H2 Canada ATTN.: Reviewing Engineer FCC ID: PUU-CPLGID2BLW1 Per section 2.911(d)(7) of the FCC rules, Savant Technologies LLC, dba GE Lighting, a Savant company (“the applicant”) certifies that the equipment for which authorization is sought is designated to the following U.S. Designated agent* for service of process: Company Name: Savant Technologies LLC, dba GE Lighting, a Savant company Physical U.S. Company Address: 1975 Noble Road, East Cleveland, OH 44112 USA Agent name: Paul Smith Agent Email Address: [email protected] FRN: 0022026876 The abo ve contact person accepts the obligation for service of process. The applicant accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment . Applicant Signed/Designated Agent Signed: Signed: Printed name: Paul Smith Title: Lead Systems Engineer – Safety & Regulatory Company Name: Savant Technologies LLC, dba GE Lighting, a Savant company Date: July 7, 2026 FRN Code: 0022026876 :
Savant Technologies LLC, dba GE Lighting, a Savant company 1975 Noble Road, East Cleveland, OH 44112 USA 6/10/2026 Nemko North America, Inc. 303 River Road Ottawa, Ontario, Canada K1V 1H2 AUTHORITY TO ACT AS AGENT - FCC On our behalf, I appoint Kathy Wang (Audix Technology (Shanghai) Co., Ltd.), to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in FCC regulations will have affixed to it a label identical to that submitted for approval with this application. In signing this letter, Applicant certifies that neither the applicant nor any party to the application is not subject to a denial of Federal benefits, that include FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. § 862 because of a conviction for possession or distribution of a controlled substance. See 47 CFR 1.2002(b) for the definition of a "party" for these purposes. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, as specified by Nemko North America Inc., still resides still resides with us. Sincerely, Printed name: Paul Smith
Savant Technologies LLC, dba GE Lighting, a Savant company 1975 Noble Road, East Cleveland, OH 44112 USA July 7, 2026 Nemko North America, Inc. 303 River Road Ottawa, Ontario, Canada K1V 1H2 REQUEST FOR CONFIDENTIALITY - FCC FCC ID: PUU-CPLGID2BLW1 Pursuant to Sections 0.457(d) and 0.459 of the Commission’s Rules and FCC Guidance document 726920, we hereby request permanent confidential treatment of exhibits identified as such in the table below and request they are permanently withheld from public review based on the documents containing trade secrets and proprietary information not customarily released to the public. The public disclosure of this information might be harmful to the applicant and provide unjustified benefits to its competitors. We also request short-term confidentiality on certain exhibits until the intended date of marketing as outlined below. We request the exhibits be withheld from public view for a period of 180 days. We attest marketing of the product will only commence after the period of short-term confidentiality expires, or if marketing is to commence before the requested number of days listed above, the grantee will inform Nemko to release the Short-Term Confidentiality information withheld on the FCC equipment authorization website. Exhibit Type of Confidentiality Requested Block Diagrams ☒Permanent ☐Short Term External Photos ------------------ ☐Short Term Internal Photos ☐Permanent*☐Short Term Operation Description ☒Permanent ☐Short Term Parts List & Placement/BOM ☐Short Term Tune-Up Procedure ☐Permanent☐Short Term Schematic Diagrams ☒Permanent ☐Short Term Test Setup Photos ------------------ ☐Short Term User’s Manual ☐Permanent*☐Short Term The asterisked items (*) require further information to be provided in this justification letter before permanent confidentiality will be extended to these exhibits. Please refer to FCC KDB 726920 D01 found at: https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=41731 and review section II, 3) regarding specific information that must accompany these requests. Note: any documents held under the Short-Term confidentiality will automatically become public after the requested time if an appropriate extension request has not been received. Any exhibits (i.e., schematic diagrams) that may have already been requested to have “Permanent” confidentiality as shown above need not be repeated under Short-Term confidentiality request. Sincerely, Signed : Printed name: Paul Smith Title: Lead Systems Engineer – Safety & Regulatory Company Name: Savant Technologies LLC, dba GE Lighting, a Savant company ☒Permanent
Appendix II Page 1 of 12 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F26126 APPENDIX II PHOTOGRAPHS OF EUT Appendix II Page 2 of 12 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F26126 FIGURE 1 DUAL SOCKETS INDOOR PLUG (M/N: CPLGID2BLW1MS) OUT-1 FIGURE 2 DUAL SOCKETS INDOOR PLUG (M/N: CPLGID2BLW1MS) OUT-2 Appendix II Page 3 of 12 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F26126 FIGURE 3 DUAL SOCKETS INDOOR PLUG (M/N: CPLGID2BLW1MS) OUT-3 FIGURE 4 DUAL SOCKETS INDOOR PLUG (M/N: CPLGID2BLW1MS) OUT-4 Appendix II Page 4 of 12 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F26126 FIGURE 5 DUAL SOCKETS INDOOR PLUG (M/N: CPLGID2BLW1MS) OUT-5 FIGURE 6 DUAL SOCKETS INDOOR PLUG (M/N: CPLGID2BLW1MS) OUT-6
29.6mm 6mm 6mm 6mm 19239CHMY为“YYDDDCHMY” 19是YY为年,239是DDD为一年中的第几日, CHMY为ChangHong MianYang 具体时间随订单要求时间变化 字体:Arial 字号:5pt PC 945 UL94V0 白色表面幼纹 镭雕二维码 技术要求: 1.镭射位置准确。 2.内容正确、不允许出现漏雕 、烧焦、白点、边沿模糊等不良现象。 4.公差+/-0.5mm 3.YY为年,DDD为日,CHMY为ChangHong MianYang,YYDDD需按订单要求时间变化。 CYNC Dual socket indoor plug 10.7mm 6mm 方框为二维码,尺寸大小为8X8mm; XXXXXXXXXXXX为MAC地址,字高1.1mm,总长12.7mm WiFi MAC: XXXXXXXXXXXX 8.5mm 6mm Model:CPLGID2BLW1MS Rating:120V AC 60Hz Max Load:General use 15A; Motor 1/3HP 1 port output:USB-C:5V 3A USB-A:5V 2.4A 2 ports output:USB-C+USB-A:15W max. in total FCC ID:PUU-CPLGID2BLW1 IC: 10798A-CPLGID2BLW1 CAN ICES-003(B)/NMB-003(B) Designed in U.S.A. Made in China 19239CHMY 7pt 6pt 1234 567 8910 TM 13.7mm 6mm CONFORMS TO UL STD. 60730-1 CERTIFIED TO CSA STD. E60730-1 字体:Arial 字号:4.5pt
29.6mm 6mm 6mm 6mm 19239CHVN为“YYDDDCHVN” 19是YY为年,239是DDD为一年中的第几日, CHVN为ChangHong Vietnam 具体时间随订单要求时间变化 字体:Arial 字号:5pt PC 945 UL94V0 白色表面幼纹 镭雕二维码 技术要求: 1.镭射位置准确。 2.内容正确、不允许出现漏雕 、烧焦、白点、边沿模糊等不良现象。 4.公差+/-0.5mm 3.YY为年,DDD为日,CHVN为ChangHong Vietnam,YYDDD需按订单要求时间变化。 CYNC Dual socket indoor plug 10.7mm 6mm 方框为二维码,尺寸大小为8X8mm; XXXXXXXXXXXX为MAC地址,字高1.1mm,总长12.7mm WiFi MAC: XXXXXXXXXXXX 8.5mm 6mm Model:CPLGID2BLW1MS Rating:120V AC 60Hz Max Load:General use 15A; Motor 1/3HP 1 port output:USB-C:5V 3A USB-A:5V 2.4A 2 ports output:USB-C+USB-A:15W max. in total FCC ID:PUU-CPLGID2BLW1 IC: 10798A-CPLGID2BLW1 CAN ICES-003(B)/NMB-003(B) Designed in U.S.A. Made in Vietnam 19239CHVN 7pt 6pt 1234 567 8910 TM 13.7mm 6mm CONFORMS TO UL STD. 60730-1 CERTIFIED TO CSA STD. E60730-1 字体:Arial 字号:4.5pt
Appendix II Page 5 of 12 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F26126 FIGURE 7 DUAL SOCKETS INDOOR PLUG (M/N: CPLGID2BLW1MS) COVER REMOVED FIGURE 8 DUAL SOCKETS INDOOR PLUG (M/N: CPLGID2BLW1MS) PCB SPLIT Appendix II Page 6 of 12 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F26126 FIGURE 9 DUAL SOCKETS INDOOR PLUG (M/N: CPLGID2BLW1MS) POWER BOARD FRONT FIGURE 10 DUAL SOCKETS INDOOR PLUG (M/N: CPLGID2BLW1MS) POWER BOARD BACK Appendix II Page 7 of 12 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F26126 FIGURE 11 DUAL SOCKETS INDOOR PLUG (M/N: CPLGID2BLW1MS) USB-C BOARD FRONT FIGURE 12 DUAL SOCKETS INDOOR PLUG (M/N: CPLGID2BLW1MS) USB-C BOARD BACK Appendix II Page 8 of 12 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F26126 FIGURE 13 DUAL SOCKETS INDOOR PLUG (M/N: CPLGID2BLW1MS) RF BOARD FRONT FIGURE 14 DUAL SOCKETS INDOOR PLUG (M/N: CPLGID2BLW1MS) RF BOARD BACK Appendix II Page 9 of 12 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F26126 FIGURE 15 DUAL SOCKETS INDOOR PLUG (M/N: CPLGID2BLW1MS) SHIELDED REMOVE FIGURE 16 DUAL SOCKETS INDOOR PLUG (M/N: CPLGID2BLW1MS) CHIP&CRYSTAL Appendix II Page 10 of 12 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F26126 FIGURE 17 DUAL SOCKETS INDOOR PLUG (M/N: CPLGID2BLW1MS) ANTENNA1 FRONT FIGURE 18 DUAL SOCKETS INDOOR PLUG (M/N: CPLGID2BLW1MS) ANTENNA1 BACK Appendix II Page 11 of 12 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F26126 FIGURE 19 DUAL SOCKETS INDOOR PLUG (M/N: CPLGID2BLW1MS) ANTENNA2 FRONT FIGURE 20 DUAL SOCKETS INDOOR PLUG (M/N: CPLGID2BLW1MS) ANTENNA2 BACK Appendix II Page 12 of 12 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F26126 ---END OF APPENDIX II---
Savant Technologies LLC, dba GE Lighting, a Savant company FCC ID: PUU-CPLGID2BLW1 Page 1 of 3 Audix Technology (Shanghai) Co., Ltd. JAREY LU / Deputy Assistant Manager HUIMIN YAN / Assistant RADIO FREQUENCY EXPOSURE EVALATION General Information Applicant : Savant Technologies LLC, dba GE Lighting, a Savant company EUT Description : Dual sockets indoor plug Model No. : CPLGID2BLW1MS Radio Tech : BLE, WIFI2.4G Frequency : 2402MHz-2480MHz, 2412MHz-2462MHz Description of Test Facility Name of Firm : Audix Technology (Shanghai) Co., Ltd. Site Location : 3F, Building 34, No. 680 Guiping Rd., Caohejing, Hi-Tech Park, Shanghai 200233, China NVLAP, Lab Code : 200371-0 FCC Designation Number : CN5027 Test Firm Registration Number: 954668 Results The EUT is operated as one mobile device with separation distance is 20 cm, and it is compliant with the RF Exposure Exemption. Producer : Savant Technologies LLC, dba GE Lighting, a Savant company FCC ID: PUU-CPLGID2BLW1 Page 2 of 3 Audix Technology (Shanghai) Co., Ltd. Evaluation Method KDB 447498 D04 Interim General RF Exposure Guidance v01 Applicable Standard: FCC CFR 47 §1.1307(b)(3)(i)(B): A single RF source is exempt if the available maximum time-averaged power or effective radiated power (ERP), whichever is greater, is less than or equal to the threshold P th (mW) described in the following formula. This method shall only be used at separation distances (cm) from 0.5 centimeters to 40 centimeters and at frequencies from 0.3 GHz to 6 GHz (inclusive). P th is given by: Savant Technologies LLC, dba GE Lighting, a Savant company FCC ID: PUU-CPLGID2BLW1 Page 3 of 3 Audix Technology (Shanghai) Co., Ltd. SAR evaluation: Mode Frequency Max output power Max Ant. Gain Max E.I.R.P P th MHz dBm mW dBi dBm mW mW BLE 2442 8.858 7.69 4.74 13.598 22.898 3060 802.11b 2462 14.69 29.44 4.74 19.43 87.700 3060 802.11g 2437 14.67 29.31 4.74 19.41 87.297 3060 802.11n20 2437 13.47 22.23 4.74 18.21 66.222 3060 Note1: For this EUT, and the separation distance is 20 cm. And the Bluetooth and WIFI can not transmit at the same time. Note2: The Conducted output power and Maximum EIRP both no greater than the threshold P th , that meets the exemption, the RF exposure evaluation is not required. -END-
Savant Technologies LLC, dba GE Lighting, a Savant company FCC ID: PUU-CPLGID2BLW1 Page 1 of 56 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F26126 Prepared For: Savant Technologies LLC, dba GE Lighting, a Savant company 1975 Noble Road Cleveland, Ohio United States 44112 Prepared By: Audix Technology (Shanghai) Co., Ltd. 3F, Building 34, No. 680 Guiping Rd., Caohejing, Hi-Tech Park, Shanghai 200233, China Tel: +86-21-64955500 File No. : C1D2605003 Report No. : ACI-F26126 Date of Test : 2026.05.18-07.13 Date of Report : 2026.07.13 TEST REPORT On behalf of Savant Technologies LLC, dba GE Lighting, a Savant company Product Name: Dual sockets indoor plug Model No.: CPLGID2BLW1MS FCC ID: PUU-CPLGID2BLW1 The statement is based on a single evaluation of one sample of the above-mentioned products. It does not imply an assessment of the whole production and does not permit the use of the test lab logo. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Government. TESTING NVLAP LAB CODE 200371-0 Savant Technologies LLC, dba GE Lighting, a Savant company FCC ID: PUU-CPLGID2BLW1 Page 2 of 56 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F26126 TABLE OF CONTENTS Page 1 SUMMARY OF STANDARDS AND RESULTS .......................................................................... 5 1.1 Description of Standards and Results ......................................................................................... 5 2 GENERAL INFORMATION .......................................................................................................... 6 2.1 Description of Equipment Under Test ........................................................................................ 6 2.2 EUT Specifications Assessed in Current Report ........................................................................ 7 2.3 Test Information ......................................................................................................................... 7 2.4 Duty Cycle Check ...................................................................................................................... 8 2.5 Sample Description .................................................................................................................... 8 2.6 Supported equipment .................................................................................................................. 8 2.7 Description of Test Facility ........................................................................................................ 9 3 CONDUCTED EMISSION TEST ................................................................................................ 10 3.1 Test Equipment ......................................................................................................................... 10 3.2 Block Diagram of Test Setup ................................................................................................... 10 3.3 Conducted Emission Limits (§15.207) ..................................................................................... 11 3.4 Test Configuration .................................................................................................................... 11 3.5 Operating Condition of EUT .................................................................................................... 11 3.6 Test Procedures ........................................................................................................................ 11 3.7 Test Results .............................................................................................................................. 12 4 RADIATED EMISSION TEST ..................................................................................................... 15 4.1 Test Equipment ......................................................................................................................... 15 4.2 Block Diagram of Test Setup ................................................................................................... 15 4.3 Radiated Emission Limit (§15.209) ......................................................................................... 17 4.4 Test Configuration .................................................................................................................... 18 4.5 Operating Condition of EUT .................................................................................................... 18 4.6 Test Procedures ........................................................................................................................ 18 4.7 Test Results .............................................................................................................................. 19 5 6 DB BANDWIDTH MEASUREMENT ...................................................................................... 40 5.1 Test Equipment ......................................................................................................................... 40 5.2 Block Diagram of Test Setup ................................................................................................... 40 5.3 Specification Limits (§15.247(a)(2)) ........................................................................................ 40 5.4 Operating Condition of EUT .................................................................................................... 40 5.5 Test Procedure .......................................................................................................................... 40 5.6 Test Results .............................................................................................................................. 41 6 MAXIMUM PEAK OUTPUT POWER MEASUREMENT ...................................................... 43 6.1 Test Equipment .........................................................................................…
Text truncated - open the document above for the full version.
Savant Technologies LLC, dba GE Lighting, a Savant company FCC ID: PUU-CPLGID2BLW1 Page 1 of 106 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F26127 Prepared For: Savant Technologies LLC, dba GE Lighting, a Savant company 1975 Noble Road Cleveland, Ohio United States 44112 Prepared By: Audix Technology (Shanghai) Co., Ltd. 3F, Building 34, No. 680 Guiping Rd., Caohejing, Hi-Tech Park, Shanghai 200233, China Tel: +86-21 -64955500 File No. : C1D2605003 Report No. : AC I-F26127 Date of Test : 202 6.05.27-07.16 Date of Report : 2026.07.22 TEST REPORT On behalf of Savant Technologies LLC, dba GE Lighting, a Savant company Product Name: Dual sockets indoor plug Model No.: CPLGID2BLW1MS FCC ID: PUU-CPLGID2BLW1 The statement is based on a single evaluation of one sample of the above-mentioned products. It does not imply an assessment of the whole production and does not permit the use of the test lab logo. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Government. TESTING NVLAP LAB CODE 200371-0 Savant Technologies LLC, dba GE Lighting, a Savant company FCC ID: PUU-CPLGID2BLW1 Page 2 of 106 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F26127 TABLE OF CONTENTS Page 1 SUMMARY OF STANDARDS AND RESULTS .......................................................................... 5 1.1 Description of Standards and Results ......................................................................................... 5 2 GENERAL INFORMATION .......................................................................................................... 6 2.1 Description of Equipment Under Test ........................................................................................ 6 2.2 EUT Specifications Assessed in Current Report ........................................................................ 7 2.3 Test Information ......................................................................................................................... 7 2.4 Duty Cycle Check ...................................................................................................................... 8 2.5 Sample Description .................................................................................................................... 9 2.6 Supported equipment .................................................................................................................. 9 2.7 Description of Test Facility ........................................................................................................ 9 3 CONDUCTED EMISSION TEST ................................................................................................ 10 3.1 Test Equipment ......................................................................................................................... 10 3.2 Block Diagram of Test Setup ................................................................................................... 10 3.3 Conducted Emission Limits (§15.207) ..................................................................................... 11 3.4 Test Configuration .................................................................................................................... 11 3.5 Operating Condition of EUT .................................................................................................... 11 3.6 Test Procedures ........................................................................................................................ 11 3.7 Test Results .............................................................................................................................. 12 4 RADIATED EMISSION TEST ..................................................................................................... 15 4.1 Test Equipment ......................................................................................................................... 15 4.2 Block Diagram of Test Setup ................................................................................................... 15 4.3 Radiated Emission Limit (§15.209) ......................................................................................... 17 4.4 Test Configuration ...........................................................................…
Text truncated - open the document above for the full version.
1975 Noble Road · Cleveland, 44112 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 7.70 mW |
| 2 | 15C | 2.41 GHz - 2.46 GHz | 29.40 mW |

CYNC Shoplight
Equipment Class
DTS - Digital Transmission SystemCync Direct Connect Strip
Equipment Class
DTS - Digital Transmission SystemPROSEO Sage LF module
Equipment Class
DTS - Digital Transmission System
Fan Switch
Equipment Class
DTS - Digital Transmission System
Cync Dynamic Effects Smart Cafe Lights
Equipment Class
DTS - Digital Transmission System