Date: 8/12/2025 Federal Communications Commissions Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 RE: CFR 47 §2.911 (d)(5) Attestation FCC ID: PUU-CSWFSBLK3T1 FRN:0031674708 1.Savant Technologies LLC, dba GE Lighting, a Savant Company (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. 2.Savant Technologies LLC, dba GE Lighting, a Savant Company (“the applicant”) certifies that, the device does not have cybersecurity and / or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, identified on the Covered List installed on the device, nor will it be installed by the applicant anytime after certification. 3.Savant Technologies LLC, dba GE Lighting, a Savant Company (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment and is not an affiliate or subsidiary of an entity identified on the Covered List. Sincerely yours, Name: Paul Smith Job Title: Principal System Engineer – Safety & Regulatory Company Name: Savant Technologies LLC, dba GE Lighting, a Savant Company
Date: 8/12/2025 Federal Communications Commissions Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 RE: CFR 47 §2.911 (d)(7) Agent Designation Attestation Grantee Code: PUU ,FRN:0031674708 To whom it may concern: Savant Technologies LLC, dba GE Lighting, a Savant Company (“the applicant”) as required by section §2.911(d)(7), will also serve as the agent for service of process for the above referenced grantee code. The applicant acknowledges that they will maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. The applicant further acknowledges their responsibility under CFR 47 §2.929(c) to inform the FCC whenever the agent information changes. Contact Person: Paul Smith Company Name: Savant Technologies LLC, dba GE Lighting, a Savant Company FCC FRN: 0031674708 Company US Address: 1975 Noble Road Cleveland Ohio 44112 United States Email: [email protected] Sincerely yours, Contact Person: Paul Smith Company Name: Savant Technologies LLC, dba GE Lighting, a Savant Company Company Address: 1975 Noble Road Cleveland Ohio 44112 United States
Savant Technologies LLC, dba GE Lighting, a Savant Company Date: 8/12/2025 Federal Communications Commission 7435 Oakland Mills Road Columbia MD 21046 To whom it may concern: I, the undersigned, hereby authorize UL Verification Services Inc. to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by UL Verification Services Inc. on our behalf shall have the same effect as acts of our own. I, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). In authorizing UL Verification Services Inc. as our representative, we still recognize that we are responsible to: a) comply with the relevant provisions of the certification program; b) make all necessary arrangements for the conduct of the evaluation, including provision for examining documentation and access to all areas, records (including internal audit reports) and personnel for the purposes of evaluation (e.g. testing, inspection, assessment, surveillance, reassessment) and resolution of complaints; c) make claims regarding certification only in respect of the scope for which certification has been granted; d) do not use our product certification in such a manner as to bring the Certification Division into disrepute and not make any statement regarding our product certification which the Certification Division may consider misleading or unauthorized; e) upon suspension or cancellation of certification, discontinue use of all advertising matter that contains any reference thereto and return any certification documents as required by the Certification Division; f) use certification only to indicate the products are certified as being in conformity with specified standards; g) endeavor to ensure that no certificate or report nor any part thereof is used in a misleading manner; h) ensure that any reference to our product certification in communication media such as documents, brochures or advertising, complies with the requirements of the Certification Division; i) keep a record of all complaints made known to us relating to the product’s compliance with requirements of the relevant standard and to make these records available to the when requested; j) take appropriate action with respect to such complaints and any deficiencies found in products or services that affect compliance with the requirements for certification; k) document the actions taken. This authorization is valid until further written notice from the applicant. Sincerely Yours, Signed by: Company Name: Savant Technologies LLC, dba GE Lighting, a Savant Company Contact Name: Paul Smith Title of Person:Principal System Engineer – Safety & Regulatory Address: 1975 Noble Road Cleveland Ohio 44112 United States
Savant Technologies LLC, dba GE Lighting, a Savant Company Federal Communications Commission 7435 Oakland Mills Road Columbia MD 21046 Subject: Request for Confidentiality FCC ID: PUU-CSWFSBLK3T1 To Whom It May Concern: Pursuant to the provisions of Sections 0.457 and 0.459 of the Commission’s rules (47 CFR §§ 0.457, 0.459), we are requesting the Commission to withhold the following attachments as confidential document from public disclosure indefinitely. Schematic Diagram Block Diagram Theory of Operation Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Best Regards Company Name: Savant Technologies LLC, dba GE Lighting, a Savant Company Contact Name: Paul Smith Title of Person:Principal System Engineer – Safety & Regulatory Address: 1975 Noble Road Cleveland Ohio 44112 United States Date: 8/12/2025
Appendix I External Photographs Page 2 of 5 External Page 3 of 5 Page 4 of 5 Page 5 of 5
2025.07.25 V1.0 Fan switch Proseo YYDDDLS 3mm 8*8mm Arial BoId,4.5pt Model: CSWFSBLK3T1/MSWF Rating: 120V AC 60Hz Max FLA 1.5A FCC ID: PUU-CSWFSBLK3T1 IC: 10798A-CSWFSBLK3T1 Designed in U.S.A Made in China 1mm GROUND LOADTRV NEUTRAL LINE For use only in 15-ampere branch circuits. Solid-State Fan Speed Control. Use Control with a ceiling paddle fan only. Not for use with exhaust fans or DC motor fans. Do not use to control a fan and light that can be operated by same switch. Arial,5pt 4.5mm CONFORMS TO UL STD. 1917 CERTIFIED TO CSA STD. C22.2#156 0.5mm 1mm 6.8mm 6.8mm : YY: DDD LS: :, !。 #$ %& Arial,4pt 5025146 Arial,6pt WIFI MAC:XXXXXXXXXXXX :'()*+ *+ WIFI MAC xxArial,4pt 1mm CSWFSBLK3T1/MSWF .Montserrat8BoId Montserrat BoId5. Arial,4pt Note:This label will be permanently engraved on this device.
Appendix II Internal Photographs Page 2 of 5 Internal Page 3 of 5 Page 4 of 5 Page 5 of 5 Antenna
The results reported herein have been performed in accordance with the laboratory’s terms of accreditation. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report apply to the test sample(s) mentioned above at the time of the testing period only and are not to be used to indicate applicability to other similar products. FCC RF EXPOSURE REPORT For Fan Switch FCC MODEL NUMBER: CSWFSBLK3T1/MSWF REPORT NUMBER: 4791828481-1-RF-3 ISSUE DATE: July 24, 2025 FCC ID: PUU-CSWFSBLK3T1 Prepared for Savant Technologies LLC, dba GE Lighting, a Savant Company 1975 Noble Road Cleveland OH 44112 United States Prepared by UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch Room 101, Building 2, No.4, Information Road, Songshan Lake, Dongguan, Guangdong, China Tel: +86 769 22038881 Fax: +86 769 33244054 Website: www.ul.com REPORT NO.: 4791828481-1-RF-3 Page 2 of 8 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM No.: 10-SL-F0112 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Revision History Rev. Issue Date Revisions Revised By V0 July 24, 2025 Initial Issue REPORT NO.: 4791828481-1-RF-3 Page 3 of 8 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM No.: 10-SL-F0112 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. TABLE OF CONTENTS 1. ATTESTATION OF TEST RESULTS .................................................................................... 4 2. TEST METHODOLOGY ........................................................................................................ 5 3. FACILITIES AND ACCREDITATION .................................................................................... 5 4. DESCRIPTION OF EUT ........................................................................................................ 6 5. REQUIREMENT .................................................................................................................... 7 REPORT NO.: 4791828481-1-RF-3 Page 4 of 8 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM No.: 10-SL-F0112 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 1. ATTESTATION OF TEST RESULTS Applicant Information Company Name: Savant Technologies LLC, dba GE Lighting, a Savant Company Address: 1975 Noble Road Cleveland OH 44112 United States Manufacturer Information Company Name: Savant Technologies LLC, dba GE Lighting, a Savant Company Address: 1975 Noble Road Cleveland OH 44112 United States EUT Information EUT Name: Fan Switch FCC Model: CSWFSBLK3T1/MSWF Sample Received Date: June 11, 2025 Sample Status: Normal Sample ID: 8576227 Date of Tested: June 11, 2025 to July 23, 2025 APPLICABLE STANDARDS STANDARD TEST RESULTS 447498 D04 Interim General RF Exposure Guidance v01 PASS Prepared By: Checked By: Wite Chen Kebo Zhang Engineer Project Associate Senior Project Engineer Approved By: Stephen Guo Operations Manager REPORT NO.: 4791828481-1-RF-3 Page 5 of 8 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM No.: 10-SL-F0112 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 2. TEST METHODOLOGY The tests documented in this report were performed in accordance with 47 CFR FCC Part 1 Subpart I, section 1.1307 and KDB 447498 D04 Interim General RF Exposure Guidance v01. 3. FACILITIES AND ACCREDITATION Accreditation Certificate A2LA (Certificate No.: 4102.01) UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch. has been assessed and proved to be in compliance with A2LA. FCC (FCC Designation No.: CN1187) UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch. Has been recognized to perform compliance testing on equipment subject to the Commission's Declaration of Conformity (DoC) and Certification rules ISED (Company No.: 21320) UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch. has been registered and fully described in a report filed with ISED. The Company Number is 21320 and the test lab Conformity Assessment Body Identifier (CABID) is CN0046. VCCI (Registration No.: C-20202, G-20240, R-20248 and T-20202) UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch. has been assessed and proved to be in compliance with VCCI, the Membership No. is 3793. Facility Name: Chamber E, the VCCI registration No. is G-20240 and R-20248 Shielding Room F, the VCCI registration No. is C-20202 and T-20202 Note 1: All tests measurement facilities use to collect the measurement data are located at Room 101, Building 2, No.4, Information Road, Songshan Lake, Dongguan, Guangdong, China. Note 2: The test anechoic chamber in UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch had been calibrated and compared to the open field sites and the test anechoic chamber is shown to be equivalent to or worst case from the open field site. Note 3: For below 30MHz, lab had performed measurements at test anechoic chamber and comparing to measurements obtained on an open field site. And these measurements below 30MHz had been correlated to measurements performed on an OFS. REPORT NO.: 4791828481-1-RF-3 Page 6 of 8 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM No.: 10-SL-F0112 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 4. DESCRIPTION OF EUT EUT Name Fan Switch Model CSWFSBLK3T1/MSWF Product Description (BLE) Frequency Range: 2402 MHz to 2480 MHz Type of Modulation: GFSK Data Rate: 1Mbps Product Descripti…
Text truncated - open the document above for the full version.
The results reported herein have been performed in accordance with the laboratory’s terms of accreditation. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report apply to the test sample(s) mentioned above at the time of the testing period only and are not to be used to indicate applicability to other similar products. CFR 47 FCC PART 15 SUBPART C ISED RSS-247 Issue 4 TEST REPORT For Fan Switch MODEL NUMBER: CSWFSBLK3T1/MSWF REPORT NUMBER: 4791828481-1-RF-1 ISSUE DATE: July 24, 2025 FCC ID: PUU-CSWFSBLK3T1 IC:10798A-CSWFSBLK3T1 Prepared for Savant Technologies LLC, dba GE Lighting, a Savant Company 1975 Noble Road Cleveland OH 44112 United States Prepared by UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch Room 101, Building 2, No.4, Information Road, Songshan Lake, Dongguan, Guangdong, China Tel: +86 769 22038881 Fax: +86 769 33244054 Website: www.ul.com REPORT NO.: 4791828481-1-RF-1 Page 2 of 100 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Revision History Rev. Issue Date Revisions Revised By V0 July 24, 2025 Initial Issue REPORT NO.: 4791828481-1-RF-1 Page 3 of 100 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Summary of Test Results Test Item Clause Limit/Requirement Result Antenna Requirement N/A FCC Part 15.203/15.247 (c) RSS-GEN Clause 6.8 Pass AC Power Line Conducted Emission ANSI C63.10-2013, Clause 6.2 FCC Part 15.207 RSS-GEN Clause 8.8 Pass Conducted Output Power ANSI C63.10-2013, Clause 11.9.2.3.1 FCC Part 15.247 (b)(3) RSS-247 Clause 5.4 (d) Pass 6dB Bandwidth and 99% Occupied Bandwidth ANSI C63.10-2013, Clause 11.8.1 FCC Part 15.247 (a)(2) RSS-247 Clause 5.2 (a) ISED RSS-Gen Clause 6.7 Pass Power Spectral Density ANSI C63.10-2013, Clause 11.10.5 FCC Part 15.247 (e) RSS-247 Clause 5.2 (b) Pass Conducted Band edge and spurious emission ANSI C63.10-2013, Clause 11.11 FCC Part 15.247(d) RSS-247 Clause 5.5 Pass Radiated Band edge and Spurious Emission ANSI C63.10-2013, Clause 11.12 & Clause 11.13 FCC Part 15.247 (d) FCC Part 15.205/15.209 RSS-247 Clause 5.5 RSS-GEN Clause 8.9 Pass Duty Cycle ANSI C63.10-2013, Clause 11.6 None; for reporting purposes only. Pass *This test report is only published to and used by the applicant, and it is not for evidence purpose in China. *The measurement result for the sample received is <Pass> according to <CFR 47 FCC PART 15 SUBPART C, ISED RSS-247 Issue 4> when <Simple Acceptance> decision rule is applied. REPORT NO.: 4791828481-1-RF-1 Page 4 of 100 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. CONTENTS 1. ATTESTATION OF TEST RESULTS..................................................................................... 6 2. TEST METHODOLOGY......................................................................................................... 7 3. FACILITIES AND ACCREDITATION..................................................................................... 7 4. CALIBRATION AND UNCERTAINTY ................................................................................... 8 4.1. MEASURING INSTRUMENT CALIBRATION ........................................................... 8 4.2. MEASUREMENT UNCERTAINTY ............................................................................ 8 5. EQUIPMENT UNDER TEST .................................................................................................. 9 5.1. DESCRIPTION OF EUT ........................................................................................... 9 5.2. CHANNEL LIST ........................................................................................................ 9 5.3. MAXIMUM POWER .................................................................................................. 9 5.4. TEST CHANNEL CONFIGURATION ...................................................................... 10 5.5. THE WORSE CASE POWER SETTING PARAMETER .......................................... 10 5.6. DESCRIPTION OF AVAILABLE ANTENNAS ......................................................... 11 5.7. SUPPORT UNITS FOR SYSTEM TEST ................................................................. 11 5.8. SETUP DIAGRAM .................................................................................................. 12 6. MEASURING EQUIPMENT AND SOFTWARE USED......................................................... 13 7. ANTENNA PORT TEST RESULTS ..................................................................................... 16 7.1. CONDUCTED OUTPUT POWER ........................................................................... 16 7.2. 6DB BANDWIDTH AND 99% OCCUPIED BANDWIDTH ........................................ 17 7.3. POWER SPECTRAL DENSITY .............................................................................. 19 7.4. CONDUCTED BAND EDGE AND SPURIOUS EMISSION ..................................... 21 7.5. DUTY CYCLE ......................................................................................................... 23 8. RADIATED TEST RESULTS ............................................................................................... 24 8.1. RESTRICTED BANDEDGE .................................................................................... 32 8.2. SPURIOUS EMISSIONS(1 GHZ~3 GHZ) ............................................................... 39 8.3. SPURIOUS EMISSIONS(3 GHZ~18 GHZ) .....…
Text truncated - open the document above for the full version.
REPORT NO.: 4791828481-1-RF-1 Page 84 of 100 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. OBW NVNT n20 2412MHz Ant1 OBW NVNT n20 2437MHz Ant1 OBW NVNT n20 2462MHz Ant1 REPORT NO.: 4791828481-1-RF-1 Page 85 of 100 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Appendix E:Maximum Power Spectral Density Level Mode Frequency (MHz) Antenna Conducted PSD (dBm/3kHz) Duty Factor (dB) Total PSD (dBm/3kHz) Limit (dBm/3kHz) Verdict b 2412 Ant1 -14.81 0 -14.81 ≤8 Pass b 2437 Ant1 -14.73 0 -14.73 ≤8 Pass b 2462 Ant1 -14.75 0 -14.75 ≤8 Pass g 2412 Ant1 -16.78 0.26 -16.52 ≤8 Pass g 2437 Ant1 -16.26 0.26 -16.00 ≤8 Pass g 2462 Ant1 -16.26 0.26 -16.00 ≤8 Pass n20 2412 Ant1 -16.35 0.28 -16.07 ≤8 Pass n20 2437 Ant1 -16.6 0.28 -16.32 ≤8 Pass n20 2462 Ant1 -16.03 0.28 -15.75 ≤8 Pass REPORT NO.: 4791828481-1-RF-1 Page 86 of 100 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Test Graphs PSD NVNT b 2412MHz Ant1 PSD NVNT b 2437MHz Ant1 PSD NVNT b 2462MHz Ant1 REPORT NO.: 4791828481-1-RF-1 Page 87 of 100 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. PSD NVNT g 2412MHz Ant1 PSD NVNT g 2437MHz Ant1 PSD NVNT g 2462MHz Ant1 REPORT NO.: 4791828481-1-RF-1 Page 88 of 100 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. PSD NVNT n20 2412MHz Ant1 PSD NVNT n20 2437MHz Ant1 PSD NVNT n20 2462MHz Ant1 REPORT NO.: 4791828481-1-RF-1 Page 89 of 100 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Appendix F:Band Edge Mode Frequency (MHz) Antenna Verdict b 2412 Ant1 Pass b 2462 Ant1 Pass g 2412 Ant1 Pass g 2462 Ant1 Pass n20 2412 Ant1 Pass n20 2462 Ant1 Pass REPORT NO.: 4791828481-1-RF-1 Page 90 of 100 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Test Graphs Band Edge NVNT b 2412MHz Ant1 Ref Band Edge NVNT b 2412MHz Ant1 Emission Band Edge NVNT b 2462MHz Ant1 Ref REPORT NO.: 4791828481-1-RF-1 Page 91 of 100 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Band Edge NVNT b 2462MHz Ant1 Emission Band Edge NVNT g 2412MHz Ant1 Ref Band Edge NVNT g 2412MHz Ant1 Emission REPORT NO.: 4791828481-1-RF-1 Page 92 of 100 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Band Edge NVNT g 2462MHz Ant1 Ref Band Edge NVNT g 2462MHz Ant1 Emission Band Edge NVNT n20 2412MHz Ant1 Ref REPORT NO.: 4791828481-1-RF-1 Page 93 of 100 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Band Edge NVNT n20 2412MHz Ant1 Emission Band Edge NVNT n20 2462MHz Ant1 Ref Band Edge NVNT n20 2462MHz Ant1 Emission REPORT NO.: 4791828481-1-RF-1 Page 94 of 100 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Appendix G:Conducted RF Spurious Emission Mode Frequency (MHz) Antenna Verdict b 2412 Ant1 Pass b 2437 Ant1 Pass b 2462 Ant1 Pass g 2412 Ant1 Pass g 2437 Ant1 Pass g 2462 Ant1 Pass n20 2412 Ant1 Pass n20 2437 Ant1 Pass n20 2462 Ant1 Pass REPORT NO.: 4791828481-1-RF-1 Page 95 of 100 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Test Graphs Tx. Spurious NVNT b 2412MHz Ant1 Ref Tx. Spurious NVNT b 2412MHz Ant1 Emission Tx. Spurious NVNT b 2437MHz Ant1 Ref REPORT NO.: 4791828481-1-RF-1 Page 96 of 100 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Tx. Spurious NVNT b 2437MHz Ant1 Emission Tx. Spurious NVNT b 2462MHz Ant1 Ref Tx. Spurious NVNT b 2462MHz Ant1 Emission REPORT NO.: 4791828481-1-RF-1 Page 97 of 100 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Tx. Spurious NVNT g 2…
Text truncated - open the document above for the full version.
The results reported herein have been performed in accordance with the laboratory’s terms of accreditation. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report apply to the test sample(s) mentioned above at the time of the testing period only and are not to be used to indicate applicability to other similar products. CFR 47 FCC PART 15 SUBPART C ISED RSS-247 Issue 4 TEST REPORT For Fan Switch MODEL NUMBER: CSWFSBLK3T1/MSWF REPORT NUMBER: 4791828481-1-RF-2 ISSUE DATE: July 24, 2025 FCC ID: PUU-CSWFSBLK3T1 IC:10798A-CSWFSBLK3T1 Prepared for Savant Technologies LLC, dba GE Lighting, a Savant Company 1975 Noble Road Cleveland OH 44112 United States Prepared by UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch Room 101, Building 2, No.4, Information Road, Songshan Lake, Dongguan, Guangdong, China Tel: +86 769 22038881 Fax: +86 769 33244054 Website: www.ul.com REPORT NO.: 4791828481-1-RF-2 Page 2 of 70 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Revision History Rev. Issue Date Revisions Revised By V0 July 24, 2025 Initial Issue REPORT NO.: 4791828481-1-RF-2 Page 3 of 70 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Summary of Test Results Test Item Clause Limit/Requirement Result Antenna Requirement N/A FCC Part 15.203/15.247 (c) RSS-GEN Clause 6.8 Pass AC Power Line Conducted Emission ANSI C63.10-2013, Clause 6.2 FCC Part 15.207 RSS-GEN Clause 8.8 Pass Conducted Output Power ANSI C63.10-2013, Clause 11.9.1.3 FCC Part 15.247 (b)(3) RSS-247 Clause 5.4 (d) Pass 6dB Bandwidth and 99% Occupied Bandwidth ANSI C63.10-2013, Clause 11.8.1 FCC Part 15.247 (a)(2) RSS-247 Clause 5.2 (a) RSS-Gen Clause 6.7 Pass Power Spectral Density ANSI C63.10-2013, Clause 11.10.2 FCC Part 15.247 (e) RSS-247 Clause 5.2 (b) Pass Conducted Band edge and spurious emission ANSI C63.10-2013, Clause 11.11 FCC Part 15.247(d) RSS-247 Clause 5.5 Pass Radiated Band edge and Spurious Emission ANSI C63.10-2013, Clause 11.12 & Clause 11.13 FCC Part 15.247 (d) FCC Part 15.205/15.209 RSS-247 Clause 5.5 RSS-GEN Clause 8.9 Pass Duty Cycle ANSI C63.10-2013, Clause 11.6 None; for reporting purposes only. Pass *This test report is only published to and used by the applicant, and it is not for evidence purpose in China. *The measurement result for the sample received is <Pass> according to <CFR 47 FCC PART 15 SUBPART C, ISED RSS-247 Issue 4> when <Simple Acceptance> decision rule is applied. REPORT NO.: 4791828481-1-RF-2 Page 4 of 70 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. CONTENTS 1. ATTESTATION OF TEST RESULTS..................................................................................... 6 2. TEST METHODOLOGY......................................................................................................... 7 3. FACILITIES AND ACCREDITATION..................................................................................... 7 4. CALIBRATION AND UNCERTAINTY ................................................................................... 8 4.1. MEASURING INSTRUMENT CALIBRATION ........................................................... 8 4.2. MEASUREMENT UNCERTAINTY ............................................................................ 8 5. EQUIPMENT UNDER TEST .................................................................................................. 9 5.1. DESCRIPTION OF EUT ........................................................................................... 9 5.2. CHANNEL LIST ..................................…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 8.60 mW |
| 2 | 15C | 2.41 GHz - 2.46 GHz | 50.00 mW |

Dual sockets indoor plug
Equipment Class
DTS - Digital Transmission System
CYNC Shoplight
Equipment Class
DTS - Digital Transmission SystemCync Direct Connect Strip
Equipment Class
DTS - Digital Transmission SystemPROSEO Sage LF module
Equipment Class
DTS - Digital Transmission System
Cync Dynamic Effects Smart Cafe Lights
Equipment Class
DTS - Digital Transmission System