Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
GE Connected A19 CLEDA199LD1, input 120Vac, frequency was 60Hz, high efficiency, safety & stability output. Use Bluetooth 4.2 and Wi-Fi 2.4G Hz chip technology to realize the far distance control. Through the APP to control the PWM signal to dim and even control the switch on & off of the bulb. Product features: 1. Controlled by Bluetooth 4.2 and 2.4G Wi-Fi to realize the far distance control. 2. CCT is 2700K. 3. With advanced chips to make sure the bulb with high efficiency, low consumption and stability. 4. Internal constant current output to make sure the high power conversion efficiency and stability output. Product Name LED LAMP Brand Name GE Model No. CLEDA199LD1@, @ rates for package information, maybe 1P~10P Working Voltage 120Vac Bluetooth Specification Version 4.2 Wi-Fi Specification 2.4G Hz Frequency Range 2400- 2483.5MHz Channel Number Bluetooth 40 Channel Separation Bluetooth 2MHz Type of Modulation Bluetooth GFSK Data Rate Bluetooth 1Mbps(GFSK) Channel Number Wi-Fi 11 Channel Separation Wi-Fi 5MHz Data Rate Wi-Fi 802.11b:11, 5.5,2,1 Mbps 802.11g: 54,48,36,24,18,12,9,6 Mbps 802.11n: up to 65Mbps Antenna Type Metal Monopole and PCB Antenna Peak Antenna Gain Bluetooth -0.34dBi Peak Antenna Gain Wi-Fi -0.64dBi For additional help, regulatory and safety Information, please go to: Federal Communications Commission (FCC) Interference Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation. The grantee is not responsible for any changes or modifications not expressly approved by the party responsible for compliance. Such modifications could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance of 20 cm between the radiator and your body. CAUTION: - DO NOT USE WITH STANDARD DIMMERS, SEE INSTRUCTIONS -NOT FOR USE IN TOTALLY ENCLOSED LUMINAIRES -SUITABLE FOR DAMP LOCATIONS -THIS DEVICE IS NOT INTENDED FOR USE WITH EMERGENCY EXITS Only use the control provided with or specified by these instructions to control this lamp. This lamp will not operate properly when connected to a standard (incandescent) dimmer or dimming control. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Radiation Exposure Statement: This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator & your body. Déclaration d'exposition aux radiations: Cet équipement est conforme aux limites d'exposition aux rayonnements IC établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps.
DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 Report no.: 20A0599R-RF-External Photo Page 1 / 2 External Photographs EUT Photo(1) EUT Photo(2) DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 Report no.: 20A0599R-RF-External Photo Page 2 / 2 EUT Photo(3)
10798A-DMSWA19II CLEDA199LD1A IC HVIN: PUU-A19-DMSWII YYDDDTS4US7 95 CLEDA199LD1
DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 Report no.: 20A0599R-RF-Internal Photo Page 1 / 5 Internal Photographs EUT Photo(1) EUT Photo(2) DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 Report no.: 20A0599R-RF-Internal Photo Page 2 / 5 EUT Photo(3) EUT Photo(4) DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 Report no.: 20A0599R-RF-Internal Photo Page 3 / 5 EUT Photo(5) EUT Photo(6) DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 Report no.: 20A0599R-RF-Internal Photo Page 4 / 5 EUT Photo(7) EUT Photo(8) DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 Report no.: 20A0599R-RF-Internal Photo Page 5 / 5 EUT Photo(9)
DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 FCC Designation Number: CN1199 Test report No: 20A0599R-RF-US-P20V01 TEST REPORT C Rules&Requlations FCC Exposure Evaluation Declaration Product Name LED LAMP Trademark GE Model and /or type reference CLEDA199LD1@ FCC ID PUU-A19-DMSWII Applicant ́s name / address Savant Technologies LLC, dba GE Lighting, a Savant Company 1975 Noble Road Cleveland, OH 44112 United States Of America Test method requested, standard KDB 447498 D01V06 FCC Part1.1310 Verdict Summary IN COMPLIANCE Documented By (name / position & signature) Kitty Li/Project Assistant Reviewed by (name / position & signature) Frank He/ Technical Supervisor Approved by (name / position & signature) Jack Zhang/ Supervisor Date of issue 2020-12-01 Report template No Template_FCC MPE-RF-V1.0 DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 FCC Designation Number: CN1199 Report no.: 20A0599R-RF-US-P20V01 Page 2 / 8 INDEX page Competences and Guarantees ................................................................................................................................... 3 General conditions ...................................................................................................................................................... 3 Environmental conditions............................................................................................................................................ 3 Possible test case verdicts ......................................................................................................................................... 4 Abbreviations .............................................................................................................................................................. 4 Document History ....................................................................................................................................................... 5 Remarks and Comments ............................................................................................................................................ 5 1. RF Exposure Evaluation ......................................................................................................................................... 6 1.1. Limits ................................................................................................................................................................... 6 1.2. Test Procedure .................................................................................................................................................... 8 1.3. Test Result of RF Exposure Evaluation............................................................................................................... 8 DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 FCC Designation Number: CN1199 Report no.: 20A0599R-RF-US-P20V01 Page 3 / 8 COMPETENCES AND GUARANTEES DEKRA is a testing laboratory competent to carry out the tests described in this report. In order to assure the traceability to other national and international laboratories, DEKRA has a calibration and maintenance program for its measurement equipment. DEKRA guarantees the reliability of the data presented in this report, which is the result of the measurements and the tests performed to the item under test on the date and under the conditions stated in the report and it is based on the knowledge and technical facilities available at DEKRA at the time of performance of the test. DEKRA is liable to the client for the maintenance of the confidentiality of all information related to the item under test and the results of the test. The results presented in this Test Report apply only to the particular item under test established in this document. IMPORTANT: No parts of this report may be reproduced or quoted out of context, in any form or by any means, except in full, without the previous written permission of DEKRA. GENERAL CONDITIONS Test Location No. 99, Hongye Road, Suzhou Industrial Park Suzhou, 215006, P.R. China Date(receive sample) Oct. 22, 2020 Date (start test) Oct. 28, 2020 Date (finish test) Nov. 10, 2020 1. This report is only referred to the item that has undergone the test. 2. This report does not constitute or imply on its own an approval of the product by the Certification Bodies or Competent Authorities. 3. This document is only valid if complete; no partial reproduction can be made without previous written permission of DEKRA. 4. This test report cannot be used partially or in full for publicity and/or promotional purposes without previous written permission of DEKRA. ENVIRONMENTAL CONDITIONS The climatic conditions during the tests are within the limits specified by the manufacturer for the operation of the EUT and the test equipment. The climatic conditions during the tests were within the following limits: Ambient temperature 15 °C – 35 °C Relative Humidity air 30% - 60% If explicitly required in the basic standard or applied product / product family standard the climatic values are recorded and documented separately in this test report. DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 FCC Designation Number: CN1199 Report no.: 20A0599R-RF-US-P20V01 Page 4 / 8 POSSIBLE TEST CASE VERDICTS Test case does not apply to test object N/A Test object does meet requirement P (Pass) / PASS Test object does not meet requirement F (Fail) / FAIL Not measured N/M ABBREVIATIONS For the purposes of the present docume…
Text truncated - open the document above for the full version.
DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 Test report No: 20A0599R-RF-US-P06V01 FCC TEST REPORT & ISED TEST REPORT Product Name LED LAMP Trademark GE Model and /or type reference CLEDA199LD1@ FCC ID PUU-A19-DMSWII IC 10798A-DMSWA19II Applicant ́s name / address Savant Technologies LLC, dba GE Lighting, a Savant Company 1975 Noble Road Cleveland, OH 44112 United States Of America Test method requested, standard FCC CFR Title 47 Part 15 Subpart C Section 15.247 ANSI C63.10: 2013 KD558074 D01 15.247 Meas Guidance v05r02 RSS-Gen Issue 5 / RSS-247 Issue 2 Verdict Summary IN COMPLIANCE Documented by (name / position & signature) Kitty Li/Project Assistant Reviewed by (name / position & signature) Frank He/ Technical Supervisor Approved by (name / position & signature) Jack Zhang/ Supervisor Date of issue 2020-12-01 Report template No Template_FCC Part 15C-RF-V1.0 DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 Report no.: 20A0599R-RF-US-P06V01 Page 2 / 72 INDEX page General conditions ............................................................................................................................................................ 4 Environmental conditions .................................................................................................................................................. 4 Possible test case verdicts ................................................................................................................................................ 5 Abbreviations..................................................................................................................................................................... 5 Document History .............................................................................................................................................................. 6 Remarks and Comments .................................................................................................................................................. 6 Used Equipment ................................................................................................................................................................ 7 Uncertainty ........................................................................................................................................................................ 9 1 General Information ............................................................................................................................................... 10 1.1 General Description of the Item(s) ............................................................................................................... 10 1.2 Antenna Information .................................................................................................................................... 11 1.3 Channel List ................................................................................................................................................. 12 2 Description of Test Setup....................................................................................................................................... 13 2.1 Operating mode(s) used for tests ................................................................................................................ 13 2.2 Auxiliary equipment / Test software for the EUT ......................................................................................... 13 2.3 Test Configuration / Block diagram used for tests ....................................................................................... 14 2.4 Testing process ........................................................................................................................................... 15 3 Verdict summary section ........................................................................................................................................ 16 3.1 Standards .................................................................................................................................................... 16 3.2 Deviation(s) from the Standard(s) / Test Specification(s) ............................................................................ 16 3.3 Overview of results ...................................................................................................................................... 17 3.4 Test Facility .................................................................................................................................................. 18 4 Test Results ........................................................................................................................................................... 19 4.1 AC Power Line Conducted Emission ........................................................................................................... 19 4.1.1 Limit ................................................................................................................................................... 19 4.1.2 Test Setup ......................................................................................................................................... 19 4.1.3 Test Procedure .................................................................................................................................. 19 4.1.4 Test Data ........................................................................................................................................... 20 4.2 Emissions in restricted frequency bands ..................................................................................................... 22 4.2.1 Limit ...........…
Text truncated - open the document above for the full version.
DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 Test report No: 20A0599R-RF-US-P06V02 FCC&ISED TEST REPORT Product Name LED LAMP Trademark GE Model and /or type reference CLEDA199LD1@ FCC ID PUU-A19-DMSWII IC 10798A-DMSWA19II Applicant ́s name / address Savant Technologies LLC, dba GE Lighting, a Savant Company 1975 Noble Road Cleveland, OH 44112 United States Of America Test method requested, standard FCC CFR Title 47 Part 15 Subpart C Section 15.247 ANSI C63.10: 2013 KDB558074 D01v05r02 RSS-Gen Issue 5 / RSS-247 Issue 2 Verdict Summary IN COMPLIANCE Documented By (name / position & signature) Kitty Li/Project Assistant Reviewed by (name / position & signature) Frank He/ Technical Supervisor Approved by (name / position & signature) Jack Zhang/ Supervisor Date of issue 2020-12-01 Report template No Template_FCC Part 15C-RF-V1.0 DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 Report no.: 20A0599R-RF-US-P06V02 Page 2 / 103 INDEX page Competences and Guarantees ................................................................................................................................... 4 General conditions ...................................................................................................................................................... 4 Environmental conditions............................................................................................................................................ 4 Possible test case verdicts ......................................................................................................................................... 5 Abbreviations .............................................................................................................................................................. 5 Document History ....................................................................................................................................................... 6 Remarks and Comments ............................................................................................................................................ 6 Used Equipment ......................................................................................................................................................... 7 Uncertainty .................................................................................................................................................................. 9 1 General Information ......................................................................................................................................... 10 1.1 General Description of the Item(s) ........................................................................................................ 10 1.2 Antenna Information .............................................................................................................................. 11 1.3 Data Rate .............................................................................................................................................. 12 1.4 Channel List .......................................................................................................................................... 14 2.1 Operating mode(s) used for tests.......................................................................................................... 15 2.2 Support / Auxiliary equipment / unit / Test software for the EUT .......................................................... 15 2.3 Test Configuration / Block diagram used for tests ................................................................................ 16 2.4 Testing process ..................................................................................................................................... 17 3.1 Standards .............................................................................................................................................. 18 3.2 Overview of results ................................................................................................................................ 18 3.3 Test Facility ........................................................................................................................................... 19 4.1 AC Power Line Conducted Emission .................................................................................................... 20 4.1.1 Limit ............................................................................................................................................. 20 4.1.2 Test Setup ................................................................................................................................... 20 4.1.3 Test Procedure ........................................................................................................................... 20 4.1.4 Test Data..................................................................................................................................... 21 4.2 Emissions in restricted frequency bands .............................................................................................. 23 4.2.1 Limit ............................................................................................................................................. 23 4.2.2 Test Setup ................................................................................................................................... 25 4.2.3 Test Procedure ........................................................................................................................... 26 4.2.4 Test Data...................................................................................…
Text truncated - open the document above for the full version.
DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 Report no.: 20A0599R-RF-FCC-Setup Photo Page 1 / 3 Setup Photographs Description: Radiated emission(Below 1G) Description: Radiated emission(1-18G) DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 Report no.: 20A0599R-RF-FCC-Setup Photo Page 2 / 3 Description: Radiated emission(Above 18G) Description: AC Line conducted emission DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 Report no.: 20A0599R-RF-FCC-Setup Photo Page 3 / 3 Description: AC Line conducted emission
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15C | 2.41 GHz - 2.46 GHz | 146.20 mW |

Dual sockets indoor plug
Equipment Class
DTS - Digital Transmission System
CYNC Shoplight
Equipment Class
DTS - Digital Transmission SystemCync Direct Connect Strip
Equipment Class
DTS - Digital Transmission SystemPROSEO Sage LF module
Equipment Class
DTS - Digital Transmission System
Fan Switch
Equipment Class
DTS - Digital Transmission System