FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Savant Technologies LLC, dba GE Lighting, a Savant Company/
  3. PUU-CAN06DW

PUU-CAN06DWModule

Savant Technologies LLC, dba GE Lighting, a Savant Company
Module - FCC ID PUU-CAN06DW - Savant Technologies LLC, dba GE Lighting, a Savant Company
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Feb 14, 2023
Application Purpose
Original Equipment
Date of Application
Feb 13, 2023
Equipment Note
Module
Frequency Range
2402.00000000 - 2480.00000000
Company
Savant Technologies LLC, dba GE Lighting, a Savant Company
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Witch-AK801-A1.0 Module FOSHAN ELECTRICAL & LIGHTING CO., LTD Witch-AK801-A1.0 Module Datasheet Version: 1.0 Date:2022-12-10 佛山电器照明股份有限公司 http://www.chinafsl.com FOSHAN ELECTRICAL & LIGHTING CO., LTD 地址:广东省佛山市禅城区汾江北路 64 号 ADD : 64 North Fenjiang Road, Foshan China This device complies with Industry Canada licence-exempt RSS standard(s). Witch-AK801-A1.0 Module FOSHAN ELECTRICAL & LIGHTING CO., LTD Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement Radiation Exposure Statement: This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. Déclaration d'exposition aux radiations: Cet équipement est conforme aux limites d'exposition aux rayonnements IC établies pour un environnement non contrôlé. Witch-AK801-A1.0 Module FOSHAN ELECTRICAL & LIGHTING CO., LTD FCCStatements This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)Thisdevicemaynotcauseharmfulinterference,and (2)thisdevicemustacceptanyinterferencereceived,includinginterferencethatmaycauseundesired operation. Changesor modificationsnot expressly approved by the party responsible for compliance couldvoid theuser'sauthoritytooperatetheequipment. FCCRadiationExposureStatement The modular can be installed or integrated in mobile or fix devices only. This modular cannot be installedinanyportabledevice,forexample,USBdongleliketransmittersisforbidden. This modular complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This transmitter must not be co-located or operating in conjunction with any other antennaortransmitter. IftheFCCidentificationnumberisnotvisiblewhenthemoduleisinstalledinsideanotherdevice,then theoutsideof thedevice into whichthemoduleis installedmust also displaya label referringtothe enclosed module. This exterior label can use wording such as the following: “Contains Transmitter ModuleFCCID:PUU-CAN06DW When the module is installed inside another device, the user manual of this device must contain belowwarningstatements: 1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)Thisdevicemaynotcauseharmfulinterference,and (2) This device must accept any interference received, including interference that may cause undesiredoperation. 2. Changes or modifications not expressly approved by the party responsible for compliance could voidtheuser'sauthoritytooperatetheequipment. The devices must be installed and used in strict accordance with the manufacturer's instructions as describedintheuserdocumentationthatcomeswiththeproduct. ThehostproductmanufacturerisresponsibleforcompliancetoanyotherFCCrulesthatapplytothe hostnotcoveredbythemodulartransmittergrantofcertification.Thefinalhostproductstillrequires Part15SubpartBcompliancetestingwiththemodulartransmitterinstalled. The end user manual shall include all required regulatory information/warning as shown in this manual,include: Witch-AK801-A1.0 Module FOSHAN ELECTRICAL & LIGHTING CO., LTD This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. Witch-AK801-A1.0 Module FOSHAN ELECTRICAL & LIGHTING CO., LTD 1. Product overview ■Witch-AK801-A1.0 isanembeddedlow-power BLE B eacon modulethatFSLhas developed. The module works in 2.400 ~ 2.480GHz general ISM frequency band. Compatible with BLE iBeacon protocol, it can realize bidirectional data transmission with smart phones through iBeacon protocol, with good performance, especially suitable for short data communication with mobile phones. ■Witch-AK801-A1.0 module in low power mode standby current is very low, and rich peripheral resources. Based on these, you can develop smart products that meet your needs. ■SMT patches are supported for the half hole of Witchy-AK801-A1.0 module. Goldfinger can insert the board and vertically install the module through wave soldering. Easy to use and reduce the development cycle. 2. Features ■Emission mode(8dBm )Working current18mA@8dBm ■Receiving mode(1Mbps)Working current18mA ■Dormant current2.5uA ■The receiving sensitivity is -90dBm in 1Mbps mode ■Transmitting maximum power8dBm ■Good anti-interference ■The receiving filter has high adjacent channel inhibition ■Antenna gain2dBi ■ Workingtemperature: :-40 to 105 °C 3.Application field ■ Smarthouseholdandhomeappliances ■ Smartsocketandlight ■ Industrialwirelesscontrol ■Security monitor Witch-AK801-A1.0 Module FOSHAN ELECTRICAL & LI…

Text truncated - open the document above for the full version.

Attestation Statements

GE Lighting, a Savant company Savant Technologies LLC 1975 Noble Rd., East Cleveland, OH 44112 Certification Application Attestation Statements Date: February 8, 2023 American Certification Body, Inc. 313 Park Avenue Suite 300 Falls Church, VA 22046 To Whom It May Concern: Statement for 47 CFR section 2.911(d)(5)(i) Savant Technologies LLC dba GE Lighting, a Savant company certifies that as of the date of the application the equipment for which authorization is sought is not “covered” equipment 1 prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, including affiliates or subsidiaries of the named companies, the applicant must include an explanation on why the equipment is not “covered” equipment. Additional Explanation: <N/A> Statement for 47 CFR section 2.911(d)(5)(ii) Savant Technologies LLC dba GE Lighting, a Savant company (“the applicant”) certifies that, as of the date of the filing of this application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Thank you, By: __________________________ _________Paul Smith____________ (Signature 2 ) (Print name) Title: _Lead Systems Engineer – safety & Regulatory_ Company: _ Savant Technologies LLC dba GE Lighting, a Savant company Telephone: _(1) 216 266 2189__________ 1 - The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist . 2 - Letters should be placed on appropriate letterhead.

Attestation Statements

GE Lighting, a Savant company Savant Technologies LLC 1975 Noble Rd., East Cleveland, OH 44112 U.S. Agent Designation for Service of Process (Applicant is Both Grantee and U.S. Agent) TO: American Certification Body, Inc. 313 Park Avenue Suite 300 Falls Church, VA 22046 ATTENTION: FCC Certification – Section 2.911(d)(7) Information This letter is to confirm that the Applicant will also serve as the U.S. Agent for Service of Process as required by 47 CFR 2.911(d)(7). The Applicant acknowledges that they must maintain an agent for no less than one year after terminating all marketing and importation OR the conclusion of any Commission-related proceeding involving the equipment. The Applicant further acknowledges their responsibility to inform the FCC whenever the Designated U.S. Agent information changes. Savant Technologies LLC dba GE Lighting, a Savant company PUU 0022026876 Paul Smith 1975 Noble Road Cleveland, Ohio, United States, 44112 (1) 216 266 2189 [email protected] Applicant Company name: Grantee Code: FRN: Contact Name: Street Address: City/Province/Zip: Telephone No: Email: Applicant Signature: Date: 8 February 2023 Signed by (Printed Name/Title): Paul Smith Lead Systems Engineer – Safety & Regulatory

Cover Letter(s)

THIS MUST BE SIGNED BY THE APPLICANT/AGENT AND SHOULD BE PLACED ON APPROPRIATE LETTERHEAD 070920-02b Request for Modular/Limited Modular Approval Date: February 10, 2023 Subject: Manufacturer’s Declaration for ☒ - Modular Approval ☐ - Split Modular Approval ☐ - Limited Modular Approval ☐ - Limited Split Modular Approval Confidentiality Request for: ______( PUU-CAN06DW)______ 8 Basic Requirements – FCC Part 15.212(a)(1) For Items Marked “NO(*)”, the Limited Module Description Must be Filled Out on the Following Pages Modular Approval Requirement Requirement Met 1. The modular transmitter must have its own RF shielding. This is intended to ensure that the module does not have to rely upon the shielding provided by the device into which it is installed in order for all modular transmitter emissions to comply with FCC limits. It is also intended to prevent coupling between the RF circuitry of the module and any wires or circuits in the device into which the module is installed. Such coupling may result in non-compliant operation. The physical crystal and tuning capacitors may be located external to the shielded radio elements. 15.212(a)(1)(i) ☒ - YES ☐ - NO(*) Details: <example – The module contains a metal shield which covers all RF components and circuitry. The shield is located on the top of the board next to antenna connector> 2. The modular transmitter must have buffered modulation/data inputs (if such inputs are provided) to ensure that the module will comply with FCC requirements under conditions of excessive data rates or over-modulation. 15.212(a)(1)(ii) ☒ - YES ☐ - NO(*) Details: <example – Data to the modulation circuit is buffered as described in the operational description provided with the application> 3. The modular transmitter must have its own power supply regulation on the module. This is intended to ensure that the module will comply with FCC requirements regardless of the design of the power supplying circuitry in the device into which the module is installed. 15.212(a)(1)(iii) ☒ - YES ☐ - NO(*) Details: <example – The module contains its own power supply regulation. Please refer to schematic filed with this application> 4. The modular transmitter must comply with the antenna and transmission system requirements of §§ 15.203, 15.204(b), 15.204(c), 15.212(a), and 2.929(b). The antenna must either be permanently attached or employ a ‘‘unique’’ antenna coupler (at all connections between the module and the antenna, including the cable). The ‘‘professional installation’’ provision of § 15.203 is not applicable to modules but can apply to limited modular approvals under paragraph 15.212(b). 15.212(a)(1)(iv) ☒ - YES ☐ - NO(*) Details: <example – The module connects to its antenna using an UFL connector which is considered a non-standard connector. A list of antennas tested and approved with this device may be found in users manual provided with the application> 5. The modular transmitter must be tested in a stand-alone configuration, i.e., the module must not be inside another device during testing. This is intended to demonstrate that the module is capable of complying with Part 15 emission limits regardless of the device into which it is eventually installed. Unless the transmitter module will be battery powered, it must comply with the AC line conducted requirements found in Section 15.207. AC or DC power lines and data input/output lines connected to the module must not contain ferrites, unless they will be marketed with the module (see Section 15.27(a)). The length of these lines shall be length typical of actual use or, if that length is unknown, at least 10 centimeters to insure that there is no coupling between the case of the module and supporting equipment. Any accessories, peripherals, or support equipment connected to the module during testing shall be unmodified or commercially available (see Section 15.31(i)). 15.212(a)(1)(v) ☒ - YES ☐ - NO(*) Details: <example – The module was tested stand-alone as shown in test setup photographs filed with this application> THIS MUST BE SIGNED BY THE APPLICANT/AGENT AND SHOULD BE PLACED ON APPROPRIATE LETTERHEAD 070920-02b Modular Approval Requirement Requirement Met 6. The modular transmitter must be labeled with its own FCC ID number, or use an electron display (see KDB Publication 784748). If using a permanently affixed label with its own FCC ID number, if the FCC ID is not visible when the module is installed inside another device, then the outside of the device into which the module is installed must also display a label referring to the enclosed module. This exterior label can use wording such as the following: “Contains Transmitter Module FCC ID: XYZMODEL1” or “Contains FCC ID: XYZMODEL1.” Any similar wording that expresses the same meaning may be used. The Grantee may either provide such a label, an example of which must be included in the application for equipment authorization, or, must provide adequate instructions along with the module which explain this requirement. In the latter case, a copy of these instructions must be included in the application for equipment authorization. If the modular transmitter uses an electronic display of the FCC identification number, the information must be readily accessible and visible on the modular transmitter or on the device in which it is installed. If the module is installed inside another device, then the outside of the device into which the module is installed must display a label referring to the enclosed module. This exterior label can use wording such as the following: “Contains FCC certified transmitter module(s).” Any similar wording that expresses the same meaning may be used. The user manual must include instructions on how to access the electronic display. A copy of these instructions must be included in the application for equipment authorization. 15.212(a)(1)(vi) ☒ - YES ☐ - NO(*) Details: <example – There is a label on the module as shown in the labeling exhibit fi…

Text truncated - open the document above for the full version.

Cover Letter(s)

Savant Technologies LLC dba GE Lighting, a Savant company 050222-17 Request for Confidentiality Date: January 31, 2023 Subject: Confidentiality Request for: ___FCC ID: PUU-CAN06DW and IC ID:_ 10789A-CAN06DW _ Pursuant to FCC 47 CFR 0.457(d) and 0.459 and/or IC RSP-100, Section 12.4, the applicant requests that a part of the subject application(s) be held confidential. Type of Confidentiality Requested Exhibit ☐ Short Term ☒ Permanent Block Diagrams ☐ Short Term --------------------------- External Photos ☐ Short Term ☐ Permanent * 1 Internal Photos ☐ Short Term ☒ Permanent Operation Description/Theory of Operation ☐ Short Term ☐ Permanent Parts List & Placement/BOM ☐ Short Term ☐ Permanent Tune-Up Procedure ☐ Short Term ☒ Permanent Schematics ☐ Short Term --------------------------- Test Setup Photos ☐ Short Term ☐ Permanent * 1 User’s Manual Savant Technologies LLC dba GE Lighting, a Savant company has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Short-Term Confidentiality for FCC Applications: The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of __ (specify number of days not to exceed 180) 2 ___ days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify ACB in the event information regarding the product or the product is made available to the public before the requested period has expired. ACB will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. Short Term Confidentiality for Industry Canada Applications: Starting May 2022, ISED will recognize short term confidentiality on certain exhibits until the intended date of marketing. The applicant requests the exhibits selected above as short term confidential be withheld from public view until: (specify ISED expiration date / date of marketing) . Sincerely, By: Lead Systems Engineer – Safety & Regulatory __Paul Smith_______ (Signature/Title 3 ) (Print name) 1 - The asterisked items (*) require further information to be provided to ACB before permanent confidentiality will be extended to these exhibits. Please refer to FCC KDB 726920 and the specific Document link for D01 found at: https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=41731 and review section II, 3) regarding specific information that must accompany these requests. 2 - Please refer to https://acbcert.com/documents/misc-docs/Memo-Short-Term-Vs-Standard-Confidentiality.pdf for complete details. 3 - Must be signed by applicant contact given for applicant on the FCC site, or by the authorized agent if an appropriate authorized agent letter has been provided. Letters should be placed on appropriate letterhead.

Cover Letter(s)

THIS MUST BE SIGNED BY THE APPLICANT/AGENT AND SHOULD BE PLACED ON APPROPRIATE LETTERHEAD 050222-17 Authority to Act as Agent Date: December 28, 2022 American Certification Body, Inc. 313 Park Avenue Suite 300 Falls Church, VA 22046 To Whom It May Concern: _DEKRA Testing and Certification (Shanghai) Ltd. Guangzhou Branch is authorized to act on our behalf, until otherwise notified, for applications to American Certification Body, Inc. (ACB). We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. We also declare that the information provided to the FCC is true and correct to the best of our knowledge (47 CFR 2.911(d)) and we have been informed of the grantee responsibilities (47 CFR 2.909) with regard to certified equipment. Thank you, By: __________________________ __Paul Smith______________________ (Signature 1 ) (Print name) Title: Lead Systems Engineer – Safety & Regulatory__________________________ On behalf of: _ Savant Technologies LLC, dba GE Lighting, a Savant Company ___________ (Company Name) Telephone: __+1 216 266 2189_________________________ 1 - Must be signed by applicant contact given for applicant on the FCC site, or by the authorized agent if an appropriate authorized agent letter has been provided. Letters should be placed on appropriate letterhead.

External Photos

Overall view

ID Label/Location Info

FCC ID and IC ID, HVIN are laser etched to the device FCC ID: PUU-CAN06DW IC: 10789A-CAN06DW HVIN: ZXWCAK801AE-M3-01 PMN: Module The FCC ID, IC, HVIN, PMN will be laser etched here:

Internal Photos

Internal view

RF Exposure Info

DEKRA Testing and Certification (Shanghai) Ltd. Guangzhou Branch Block 5, No.3, Qiyun Road, Huangpu District, Guangzhou, Guangdong, China Tel +86 20 6661 2000 Fax +86 20 6661 2001 www.dekra-certification.com Report no.: 4394326.55 Page 1 / 9 Test report No: 4394326.55 TEST REPORT Radio Spectrum Matters (RF) Identification of item tested Module Trademark / Model and /or type reference ZXWCAK801AE-M3-01 FCC ID PUU-CAN06DW Features 3,3 Vdc Applicant ́s name / address Savant Technologies LLC dba GE Lighting, a Savant company 1975 Noble Road, Cleveland, Ohio, United States, 44112 Test method requested, standard KDB 447498 D01V06 FCC Part 1.1310 Verdict Summary COMPLIANCE Tested by (name & signature) Johnny Bo Approved by (name & signature) Tim Yan Date of issue 2023-02-05 Report template No TRF_EMC 2017-06- FCC_Exposure DEKRA Testing and Certification (Shanghai) Ltd. Guangzhou Branch Block 5, No.3, Qiyun Road, Huangpu District, Guangzhou, Guangdong, China Tel +86 20 6661 2000 Fax +86 20 6661 2001 www.dekra-certification.com Report no.: 4394326.55 Page 2 / 9 INDEX page General conditions ...................................................................................................................................................... 3 Uncertainty .................................................................................................................................................................. 3 Environmental conditions............................................................................................................................................ 3 Possible test case verdicts ......................................................................................................................................... 3 Definition of symbols used in this test report .............................................................................................................. 4 Abbreviations .............................................................................................................................................................. 4 Document History ....................................................................................................................................................... 4 Remarks and Comments ............................................................................................................................................ 4 1 General Information ........................................................................................................................................... 5 1.1 General Description of the Item(s) .......................................................................................................... 5 1.2 Test data ................................................................................................................................................. 6 1.3 The environment(s) in which the EUT is intended to be used ................................................................ 6 2 Description of Test Setup .................................................................................................................................. 7 2.1 Operating mode(s) used for tests............................................................................................................ 7 2.2 Support / Auxiliary equipment / unit / software for the EUT .................................................................... 7 2.3 Test Configuration / Block diagram used for tests .................................................................................. 7 3 RF Exposure Evaluation .................................................................................................................................... 8 3.1 Limits ....................................................................................................................................................... 8 3.2 Test Procedure ........................................................................................................................................ 9 3.3 Test Result .............................................................................................................................................. 9 DEKRA Testing and Certification (Shanghai) Ltd. Guangzhou Branch Block 5, No.3, Qiyun Road, Huangpu District, Guangzhou, Guangdong, China Tel +86 20 6661 2000 Fax +86 20 6661 2001 www.dekra-certification.com Report no.: 4394326.55 Page 3 / 9 GENERAL CONDITIONS 1. This report is only referred to the item that has undergone the test. 2. This report does not constitute or imply on its own an approval of the product by the Certification Bodies or Competent Authorities. 3. This document is only valid if complete; no partial reproduction can be made without previous written permission of DEKRA. 4. This test report cannot be used partially or in full for publicity and/or promotional purposes without previous written permission of DEKRA. 5. This report will not be used for social proof function in China market. UNCERTAINTY For all measurements where guidance for the calculation of the instrumentation uncertainty of a measurement is specified in EN 55016-4-2 (CISPR 16-4-2), EN/IEC 61000-4 series or a product standard, the measurement instrumentation uncertainty has been calculated and applied in accordance with these standards. Uncertainties have been calculated according to the DEKRA internal document. The reported expanded uncertainties are based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95%. ENVIRONMENTAL CONDITIONS The climatic conditions during the tests are within the limits specified by the manufacturer for the operation of the EUT and the test equipment. The climatic conditions during the tests were within the following limits: Ambient temperature 15 °C – 35 °C Relative Humidity air 30% - 60% Atmospheric pressure 86 kPa – 106 kPa If exp…

Text truncated - open the document above for the full version.

Test Report

深圳市合拓科技有限公司 Frequency ID 1 2 3 4 5 6 7 8 9 10 11 Frequency (MHz) 2400.0 2410.0 2420.0 2430.0 2440.0 2450.0 2460.0 2470.0 2480.0 2490.0 2500.0 Efficiency (dBi) -5.68 -5.70 -5.71 -5.48 -5.25 -5.05 -5.11 -4.95 -5.46 -5.27 -5.37 Gain (dBi) 1.79 1.94 2.12 2.17 1.97 2.16 1.73 1.89 1.23 1.47 1.64 Efficiency (%) 27.03 26.92 26.88 28.31 29.83 31.29 30.85 31.96 28.42 29.72 29.05 Directivity (dB) 7.47 7.64 7.82 7.65 7.22 7.21 6.83 6.85 6.70 6.74 7.01 Peak Gain Position (Theta) 135.00 135.00 135.00 135.00 135.00 135.00 120.00 120.00 120.00 135.00 135.00 Peak Gain Position (Phi) 150.00 150.00 165.00 150.00 165.00 180.00 150.00 150.00 135.00 165.00 150.00 Efficiency ThetaPol (%) 21.70 21.82 21.65 23.09 24.43 25.88 25.29 26.21 23.24 24.35 23.70 Efficiency PhiPol (%) 5.33 5.10 5.24 5.22 5.40 5.42 5.56 5.74 5.18 5.37 5.35 Upper Hem. Efficiency (%) 4.79 4.93 5.08 5.57 6.10 6.64 6.46 6.42 5.64 5.82 5.38 Lower Hem. Efficiency (%) 22.24 21.98 21.80 22.74 23.73 24.66 24.38 25.54 22.78 23.89 23.66 VER7 T90(H)圆度 13.44 17.61 15.95 18.32 16.31 16.14 15.84 11.35 9.52 9.55 9.82 Gain 15deg (dBi) E1(XZ)波瓣宽度 58.00 59.00 61.00 61.00 67.00 68.00 67.00 72.00 62.00 63.00 63.00 E1(XZ)前后比 1.09 0.68 0.60 0.31 0.41 0.53 0.65 0.67 0.78 0.84 0.78 E2(YZ)波瓣宽度 40.00 46.00 43.00 49.00 49.00 51.00 54.00 55.00 51.00 58.00 55.00 E2(YZ)前后比 0.00 0.00 0.00 0.00 0.00 0.00 0.13 0.07 0.56 0.03 0.06 最大增益处轴比(P) 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 仰角10度最差(大)轴比(P) 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 Hc(XY)波瓣宽度 100.00 98.00 101.00 80.00 77.00 92.00 105.00 101.00 110.00 113.00 112.00 Hc(XY)前后比 6.00 6.57 6.31 7.64 8.62 6.35 5.02 4.72 4.79 3.95 2.41 Empty 26.88 31.96 0.00 10.00 20.00 30.00 40.00 50.00 60.00 70.00 80.00 90.00 100.00 2400.02410.02420.02430.02440.02450.02460.02470.02480.02490.02500.0 Efficiency (%) 2.17 1.23 -7.00 -6.00 -5.00 -4.00 -3.00 -2.00 -1.00 0.00 1.00 2.00 3.00 2400.02410.02420.02430.02440.02450.02460.02470.02480.02490.02500.0 0.00 10.00 20.00 30.00 40.00 50.00 60.00 70.00 80.00 90.00 100.00 2400.02410.02420.02430.02440.02450.02460.02470.02480.02490.02500.0 Efficiency ThetaPol (%) 0.00 10.00 20.00 30.00 40.00 50.00 60.00 70.00 80.00 90.00 100.00 2400.02410.02420.02430.02440.02450.02460.02470.02480.02490.02500.0 Upper Hem. Efficiency (%)

Test Report

DEKRA Testing and Certification (Shanghai) Ltd. Guangzhou Branch Block 5, No.3, Qiyun Road, Huangpu District, Guangzhou, Guangdong, China Tel +86 20 6661 2000 Fax +86 20 6661 2001 www.dekra-certification.com Report no.: 4394326.50 Page 1 / 46 Test report No: 4394326.50 TEST REPORT Radio Spectrum Matters (RF) Identification of item tested Module Trademark / Model and /or type reference ZXWCAK801AE-M3-01 FCC ID PUU-CAN06DW Features 3.3 Vdc Applicant ́s name / address Savant Technologies LLC dba GE Lighting, a Savant company 1975 Noble Road, Cleveland, Ohio, United States, 44112 Test method requested, standard FCC CFR Title 47 Part15 Subpart C Section 15.247; KDB558074 D01v05r02; Verdict Summary COMPLIANCE Tested by (name & signature) Johnny Bo Approved by (name & signature) Jazz Liang Date of issue 2023-02-05 Report template No TRF_EMC 2017-06- FCC_Part15C_247 DEKRA Testing and Certification (Shanghai) Ltd. Guangzhou Branch Block 5, No.3, Qiyun Road, Huangpu District, Guangzhou, Guangdong, China Tel +86 20 6661 2000 Fax +86 20 6661 2001 www.dekra-certification.com Report no.: 4394326.50 Page 2 / 46 INDEX page General conditions ...................................................................................................................................................... 4 Uncertainty .....................................................................................................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Paul Smith(Systems Engineer - Safety & Regulatory)
[email protected]2162662189Fax: 2162663003

Technical Contact

Savant Technologies LLC dba GE Lighting, a SavantDavid Dai
[email protected]

1975 Noble Road, Cleveland · United States

Test Firm

DEKRA Testing and Certification (Shanghai) Ltd.Johnson Liu
[email protected]+86 20 66642980

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz330.00 µW
Modular Type
Single Modular Approval
Confidentiality
Long Term
Grant Notes
Power Output listed is conducted. Modular Approval. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Savant Technologies LLC, dba GE Lighting, a Savant Company

Dual sockets indoor plug - FCC ID PUU-CPLGID2BLW1 - Savant Technologies LLC, dba GE Lighting, a Savant Company
PUU-CPLGID2BLW1

Dual sockets indoor plug

Aug 05, 2026

Equipment Class

DTS - Digital Transmission System
CYNC Shoplight - FCC ID PUU-CFIXSHP46 - Savant Technologies LLC, dba GE Lighting, a Savant Company
PUU-CFIXSHP46

CYNC Shoplight

Jul 31, 2026

Equipment Class

DTS - Digital Transmission System
PUU-STR-CBDMI

Cync Direct Connect Strip

Jul 30, 2026

Equipment Class

DTS - Digital Transmission System
PUU-GEL-HAL

PROSEO Sage LF module

May 19, 2026

Equipment Class

DTS - Digital Transmission System
Fan Switch - FCC ID PUU-CSWFSBLK3T1 - Savant Technologies LLC, dba GE Lighting, a Savant Company
PUU-CSWFSBLK3T1

Fan Switch

Sep 04, 2025

Equipment Class

DTS - Digital Transmission System