Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Savant Technologies LLC, dba GE Lighting, a Savant company 1975 Noble Road, East Cleveland, OH 44112 USA * the applicant must designate a contact located in the United States for purposes of acting as the applicant’s agent for service of process, regardless of whether the applicant is a domestic or foreign entity. An applicant located in the United States may designate itself as the agent for service of process. U.S. Agent Designation for Service of Process - Certification Attestation Letter September 18, 2023 Nemko North America, Inc. 303 River Road Ottawa K1V 1H2 Canada ATTN.: Reviewing Engineer FCC ID: PUU-CFIXRSCR6C Per section 2.911(d)(7) of the FCC rules, Savant Technologies LLC, dba GE Lighting, a Savant company (“the applicant”) certifies that the equipment for which authorization is sought is designated to the following U.S. Designated agent* for service of process: Company Name: Savant Technologies LLC, dba GE Lighting, a Savant company Physical U.S. Company Address: 1975 Noble Road, East Cleveland, OH 44112 USA Agent name: Paul Smith Agent Email Address: [email protected] FRN: 0022026876 The above contact person accepts the obligation for service of process. The applicant accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Applicant Signed: Designated Agent Signed: (Required, if different to Applicant): Signed: Signed: Printed name: Paul Smith Printed name: Click here to enter text. Title: Lead Systems Engineer – Safety & Regulatory Title: Click here to enter text. Company Name: Savant Technologies LLC, dba GE Lighting, a Savant company Company Name: Click here to enter text. Date: September 18, 2023 Date: Click here to enter a date.
Savant Technologies LLC, dba GE Lighting, a Savant company 1975 Noble Road, East Cleveland, OH 44112 USA Covered Equipment Certification Attestation Letter 9/15/2023 Nemko North America, Inc. 303 River Road Ottawa K1V 1H2 Canada ATTN.: Reviewing Engineer FCC ID: PUU-CFIXRSCR6C Savant Technologies LLC, dba GE Lighting, a Savant company (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Note: If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, the applicant should include an explanation on why the equipment is not “covered” equipment. Savant Technologies LLC, dba GE Lighting, a Savant company (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Signed: Printed name: Paul Smith Title: Lead Systems Engineer – Safety & Regulatory Company Name: Savant Technologies LLC, dba GE Lighting, a Savant company Date: 9/15/2023
Savant Technologies LLC, dba GE Lighting, a Savant company 1975 Noble Road, East Cleveland, OH 44112 USA 5/25/2023 Nemko North America, Inc. 303 River Road Ottawa, Ontario, Canada K1V 1H2 AUTHORITY TO ACT AS AGENT - FCC On our behalf, I appoint Kamp Chen (Audix Technology (Shanghai) Co., Ltd.), to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in FCC regulations will have affixed to it a label identical to that submitted for approval with this application. In signing this letter, Applicant certifies that neither the applicant nor any party to the application is not subject to a denial of Federal benefits, that include FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. § 862 because of a conviction for possession or distribution of a controlled substance. See 47 CFR 1.2002(b) for the definition of a "party" for these purposes. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, as specified by Nemko North America Inc., still resides still resides with us. Sincerely, Printed name: Paul Smith
Savant Technologies LLC, dba GE Lighting, a Savant company 1975 Noble Road, East Cleveland, OH 44112 USA 9/18/2023 Nemko North America, Inc. 303 River Road Ottawa, Ontario, Canada K1V 1H2 REQUEST FOR CONFIDENTIALITY - FCC FCC ID: PUU-CFIXRSCR6C Pursuant to Sections 0.457(d)(1)(ii) and 0.459 of the Commission’s Rules and FCC Guidance document 726920, we hereby request confidential treatment of information accompanying this application as outlined below: PERMANENT LONG-TERM CONFIDENTIALITY: Schematics Bill of Materials/Parts List Block Diagrams Theory of Operation The above information contains trade secrets and proprietary information not customarily released to the public. The public disclosure of this information might be harmful to the applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457(d)(1)(ii), disclosure of this Application and all accompanying materials will not be made before the date of the Grant for this Application. Sincerely, Signed: Printed name: Paul Smith Title: Lead Systems Engineer – Safety & Regulatory
Appendix II Page 1 of 5 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F23170 APPENDIX II PHOTOGRAPHS OF EUT Appendix II Page 2 of 5 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F23170 FIGURE 1 D OWNLIGHT (CFIXRSCR6CRVD) GENERAL APPEARANCE FIGURE 2 DOWNLIGHT (CFIXRSCR6CRVD) BACK APPEARANCE
Label Location: Label A E C D B CFIXRSCR6CRVD 1150 lm 13W 110mA 120V 60Hz FCC ID: PUU-CFIXRSCR6C IC: 10798A-CFIXRSCR6C HVIN: CFIXRSCR6CRVD 23088FL CONVIENTAUX EMPLACEMENTS MOUILLÉS COVERED CEILING MOUNT ONLY INSTALLATION SUR PLAFOND COUVERT SEULEMENT DO NOT USE WITH STANDARD DIMMERS, SEE INSTRUCTIONS NE PAS UTILISER AVEC DES GRADATEURS STANDARD SE REPORTER AUX INSTRUCTIONS CONFORMS TO ANSI/UL STD.1598C/STD.1993 CERTIFIED TO CAN/CSA STD. C22.2 No.250.1/No.1993 8 mm 3 mm 15 mm 84 mm 3 mm3 mm 3 mm 3 mm 2 mm 1.6 mm SUITABLE FOR WET LOCATIONS MADE IN CHINA GM
Appendix II Page 3 of 5 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F23170 FIGURE 3 D OWNLIGHT (CFIXRSCR6CRVD) COVER REMOVE FIGURE 4 DOWNLIGHT (CFIXRSCR6CRVD) LED FRONT Appendix II Page 4 of 5 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F23170 FIGURE 5 D OWNLIGHT (CFIXRSCR6CRVD) LED BACK FIGURE 6 DOWNLIGHT (CFIXRSCR6CRVD) M AINBOARD FRONT Appendix II Page 5 of 5 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F23170 FIGURE 7 D OWNLIGHT (CFIXRSCR6CRVD) MAINBOARD BACK FIGURE 8 DOWNLIGHT (CFIXRSCR6CRVD) RF BOARD Antenna
Savant Technologies LLC, dba GE Lighting, a Savant company FCC ID: PUU-CFIXRSCR6C Page 1 of 2 Audix Technology (Shanghai) Co., Ltd. RADIO FRREQUENCY EXPOSURE EVALUATION Evaluation Method: KDB 447498 D01 v6 Applicable Standard: FCC CFR 47§1.1310 : Radiofrequency radiation exposure limits. Note: (1) Occupational/controlled exposure limits apply in situations in which persons are exposed as a consequence of their employment provided those persons are fully aware of the potential for exposure and can exercise control over their exposure. Limits for occupational/controlled exposure also apply in situations when a person is transient through a location where occupational/controlled limits apply provided he or she is made aware of the potential for exposure. (2) General population/uncontrolled exposure limits apply in situations in which the general public may be exposed, or in which persons who are exposed as a consequence of their employment may not be fully aware of the potential for exposure or cannot exercise control over their exposure. MPE Calculation Standard: MPE(S) = PG/(4휋푅 2 ) where: S = power density (in appropriate units, e.g. mW/ cm 2 ) P = power input to the antenna (in appropriate units, e.g., mW) G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna (appropriate units, e.g., cm) Savant Technologies LLC, dba GE Lighting, a Savant company FCC ID: PUU-CFIXRSCR6C Page 2 of 2 Audix Technology (Shanghai) Co., Ltd. Calculation Result: For this EUT, General population/uncontrolled exposure limits applied. The limit value 1.0mW/cm 2 is available for this EUT. The Evaluation distance (R) = 20cm. The Data derived from the RF test report. And for this EUT, the WIFI and BT function cannot simultaneously transmit. Modulation Peak Output Power Antenna Gain MPE Limit Verdict (dBm) (mW) (dBi) (Numeric) (mW/cm 2 ) (mW/cm 2 ) BLE 8.787 7.563 0.5 1.122 0.0017 1.0 Compliant 802.11b 12.86 19.320 0.5 1.122 0.0043 1.0 Compliant 802.11g 15.39 34.594 0.5 1.122 0.0077 1.0 Compliant 802.11n20 14.32 27.040 0.5 1.122 0.0060 1.0 Compliant
Savant Technologies LLC, dba GE Lighting, a Savant company FCC ID: PUU-CFIXRSCR6C Page 1 of 47 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F23170 Prepared For: Savant Technologies LLC, dba GE Lighting, a Savant company 1975 Noble Road Cleveland, Ohio United States 44112 Prepared By: Audix Technology (Shanghai) Co., Ltd. 3F, Building 34, No. 680 Guiping Rd., Caohejing, Hi-Tech Park, Shanghai 200233, China Tel: +86-21-64955500 File N o. : C1D2309030 Report N o. : ACI- F23170 Date of Test : 2023.04.28-09.02 Date of Report : 2023.09.18 TEST REPORT On behalf of Savant Technologies LLC, dba GE Lighting, a Savant company Product Name: Downlight Model No.: CFIXRSCR6CRVD@ FCC ID: PUU-CFIXRSCR6C The statement is based on a single evaluation of one sample of the above-mentioned products. It does not imply an assessment of the whole production and does not permit the use of the test lab logo. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Government. TESTING NVLAP LAB CODE 200371-0 Savant Technologies LLC, dba GE Lighting, a Savant company FCC ID: PUU-CFIXRSCR6C Page 2 of 47 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F23170 TABLE OF CONTENTS Page 1 SUMMARY OF STANDARDS AND RESULTS .......................................................................... 5 1.1 Description of Standards and Results ......................................................................................... 5 2 GENERAL INFORMATION .......................................................................................................... 6 2.1 Description of Equipment Under Test ........................................................................................ 6 2.2 EUT Specifications Assessed in Current Report ........................................................................ 7 2.3 Test Information ......................................................................................................................... 7 2.4 Duty Cycle Check ...................................................................................................................... 7 2.5 Sample Description .................................................................................................................... 8 2.6 Supported equipment .................................................................................................................. 8 2.7 Description of Test Facility ........................................................................................................ 8 3 CONDUCTED EMISSION TEST .................................................................................................. 9 3.1 Test Equipment........................................................................................................................... 9 3.2 Block Diagram of Test Setup ..................................................................................................... 9 3.3 Conducted Emission Limits (§15.207) ..................................................................................... 10 3.4 Test Configuration .................................................................................................................... 10 3.5 Operating Condition of EUT .................................................................................................... 10 3.6 Test Procedures ........................................................................................................................ 10 3.7 Test Results .............................................................................................................................. 11 4 RADIATED EMISSION TEST ..................................................................................................... 14 4.1 Test Equipment......................................................................................................................... 14 4.2 Block Diagram of Test Setup ................................................................................................... 15 4.3 Radiated Emission Limit (§15.209) ......................................................................................... 16 4.4 Test Configuration .................................................................................................................... 16 4.5 Operating Condition of EUT .................................................................................................... 16 4.6 Test Procedures ........................................................................................................................ 16 4.7 Test Results .............................................................................................................................. 18 5 6 DB BANDWIDTH MEASUREMENT ...................................................................................... 31 5.1 Test Equipment......................................................................................................................... 31 5.2 Block Diagram of Test Setup ................................................................................................... 31 5.3 Specification Limits (§15.247(a)(2)) ........................................................................................ 31 5.4 Operating Condition of EUT .................................................................................................... 31 5.5 Test Procedure .......................................................................................................................... 31 5.6 Test Results .............................................................................................................................. 32 6 MAXIMUM PEAK OUTPUT POWER MEASUREMENT ...................................................... 34 6.1 Test Equipment........................................................................................................…
Text truncated - open the document above for the full version.
Savant Technologies LLC, dba GE Lighting, a Savant company FCC ID: PUU-CFIXRSCR6C Page 1 of 79 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F23171 Prepared For: Savant Technologies LLC, dba GE Lighting, a Savant company 1975 Noble Road Cleveland, Ohio United States 44112 Prepared By: Audix Technology (Shanghai) Co., Ltd. 3F, Building 34, No. 680 Guiping Rd., Caohejing, Hi-Tech Park, Shanghai 200233, China Tel: +86-21-64955500 File No. : C1D2309030 Report No. : ACI- F23171 Date of Test : 2023.04.28-05.17 Date of Report : 2023.09.18 TEST REPORT On behalf of Savant Technologies LLC, dba GE Lighting, a Savant company Product Name: Downlight Model No.: CFIXRSCR6CRVD@ FCC ID: PUU-CFIXRSCR6C The statement is based on a single evaluation of one sample of the above-mentioned products. It does not imply an assessment of the whole production and does not permit the use of the test lab logo. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Government. TESTING NVLAP LAB CODE 200371-0 Savant Technologies LLC, dba GE Lighting, a Savant company FCC ID: PUU-CFIXRSCR6C Page 2 of 79 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F23171 TABLE OF CONTENTS Page 1 SUMMARY OF STANDARDS AND RESULTS .......................................................................... 5 1.1 Description of Standards and Results ......................................................................................... 5 2 GENERAL INFORMATION .......................................................................................................... 6 2.1 Description of Equipment Under Test ........................................................................................ 6 2.2 EUT Specifications Assessed in Current Report ........................................................................ 7 2.3 Test Information ......................................................................................................................... 7 2.4 Duty Cycle Check ...................................................................................................................... 8 2.5 Sample Description .................................................................................................................... 9 2.6 Supported equipment .................................................................................................................. 9 2.7 Description of Test Facility ........................................................................................................ 9 3 CONDUCTED EMISSION TEST ................................................................................................ 10 3.1 Test Equipment......................................................................................................................... 10 3.2 Block Diagram of Test Setup ................................................................................................... 10 3.3 Conducted Emission Limits (§15.207) ..................................................................................... 11 3.4 Test Configuration .................................................................................................................... 11 3.5 Operating Condition of EUT .................................................................................................... 11 3.6 Test Procedures ........................................................................................................................ 11 3.7 Test Results .............................................................................................................................. 12 4 RADIATED EMISSION TEST ..................................................................................................... 15 4.1 Test Equipment......................................................................................................................... 15 4.2 Block Diagram of Test Setup ................................................................................................... 16 4.3 Radiated Emission Limit (§15.209) ......................................................................................... 17 4.4 Test Configuration .................................................................................................................... 17 4.5 Operating Condition of EUT .................................................................................................... 17 4.6 Test Procedures ........................................................................................................................ 17 4.7 Test Results .............................................................................................................................. 19 5 99% OCCUPIED BANDWIDTH MEASUREMENT ................................................................ 44 5.1 Test Equipment......................................................................................................................... 44 5.2 Block Diagram of Test Setup ................................................................................................... 44 5.3 Operating Condition of EUT .................................................................................................... 44 5.4 Test Procedure .......................................................................................................................... 44 5.5 Test Results .............................................................................................................................. 45 6 6 DB BANDWIDTH MEASUREMENT ...................................................................................... 49 6.1 Test Equipment......................................................................................................................... 49 6.2 Block Diagram of Test Setup ..............................................................................…
Text truncated - open the document above for the full version.
1. Modle : ANT-JXC32-18 2. ANTENNASPECIFICATIONS ItemSpecifications Antenna Frequency Range2400~2483.5MHz PolarizationLinear Peak Gain0.5dBi V.S.W.R < 2.0 Impedance50Ω Return Loss-10dB ConnectorMicrostrip line connection Efficiency 25% TypeOnboard Size12.5x6.5mm Environmental Operating Temperature -10°C~+60°C 3.Manufacturer ManufacturerShenzhen Jingxun Techology Limited Co.,Ltd Manufacturer address 3/F,A5 Building Zhiyuan Community No.1001, Xueyuan Road, Nanshan District,Shenzhen City,China 4.ANTENNAPATTERN 5.Antenna Picture
Appendix I Page 1 of 5 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F23170 APPENDIX I PHOTOGRAPHS OF TEST Appendix I Page 2 of 5 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F23170 Test Set-Up Photos 1. Conducted Test F RONT VIEW B ACK VIEW Appendix I Page 3 of 5 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F23170 2. Radiated Test (BELOW 1GHZ) FRONT (B ELOW 1GHZ) BACK Appendix I Page 4 of 5 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F23170 (ABOVE 1GHZ) FRONT (ABOVE 1GHZ) BACK Appendix I Page 5 of 5 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F23170 3. Antenna-port Conducted Test
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15C | 2.41 GHz - 2.46 GHz | 34.60 mW |

Dual sockets indoor plug
Equipment Class
DTS - Digital Transmission System
CYNC Shoplight
Equipment Class
DTS - Digital Transmission SystemCync Direct Connect Strip
Equipment Class
DTS - Digital Transmission SystemPROSEO Sage LF module
Equipment Class
DTS - Digital Transmission System
Fan Switch
Equipment Class
DTS - Digital Transmission System