FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Savant Technologies LLC, dba GE Lighting, a Savant Company/
  3. PUU-QO260PWX

PUU-QO260PWX240 Vac 60 A Wiser Control Relay

Savant Technologies LLC, dba GE Lighting, a Savant Company
240 Vac 60 A Wiser Control Relay - FCC ID PUU-QO260PWX - Savant Technologies LLC, dba GE Lighting, a Savant Company
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Aug 23, 2023
Application Purpose
Original Equipment
Date of Application
Aug 23, 2023
Equipment Note
240 Vac 60 A Wiser Control Relay
Frequency Range
2405.00000000 - 2480.00000000
Company
Savant Technologies LLC, dba GE Lighting, a Savant Company
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Caution: Changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment.

Attestation Statements

Savant Technologies LLC, dba GE Lighting, a Savant company 1975 Noble Road, East Cleveland, OH 44112 USA * the applicant must designate a contact located in the United States for purposes of acting as the applicant’s agent for service of process, regardless of whether the applicant is a domestic or foreign entity. An applicant located in the United States may designate itself as the agent for service of process. U.S. Agent Designation for Service of Process - Certification Attestation Letter July 31, 2023 Nemko North America, Inc. 303 River Road Ottawa K1V 1H2 Canada ATTN.: Reviewing Engineer FCC ID: PUU-QO260PWX Per section 2.911(d)(7) of the FCC rules, Savant Technologies LLC, dba GE Lighting, a Savant company (“the applicant”) certifies that the equipment for which authorization is sought is designated to the following U.S. Designated agent* for service of process: Company Name: Savant Technologies LLC, dba GE Lighting, a Savant company Physical U.S. Company Address: 1975 Noble Road, East Cleveland, OH 44112 USA Agent name: Paul Smith Agent Email Address: [email protected] FRN: 0022026876 The above contact person accepts the obligation for service of process. The applicant accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Applicant Signed: Designated Agent Signed: (Required, if different to Applicant): Signed: Signed: Printed name: Paul Smith Printed name: Click here to enter text. Title: Lead Systems Engineer – Safety & Regulatory Title: Click here to enter text. Company Name: Savant Technologies LLC, dba GE Lighting, a Savant company Company Name: Click here to enter text. Date: July 31, 2023 Date: Click here to enter a date.

Cover Letter(s)

Savant Technologies LLC, dba GE Lighting, a Savant company 1975 Noble Road, East Cleveland, OH 44112 USA 5/25/2023 Nemko North America, Inc. 303 River Road Ottawa, Ontario, Canada K1V 1H2 AUTHORITY TO ACT AS AGENT - FCC On our behalf, I appoint Kamp Chen (Audix Technology (Shanghai) Co., Ltd.), to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in FCC regulations will have affixed to it a label identical to that submitted for approval with this application. In signing this letter, Applicant certifies that neither the applicant nor any party to the application is not subject to a denial of Federal benefits, that include FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. § 862 because of a conviction for possession or distribution of a controlled substance. See 47 CFR 1.2002(b) for the definition of a "party" for these purposes. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, as specified by Nemko North America Inc., still resides still resides with us. Sincerely, Printed name: Paul Smith

External Photos

Appendix II Page 1 of 8 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F23158 APPENDIX II P HOTOGRAPHS OF EUT Appendix II Page 2 of 8 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F23158 FIGURE 1 240 VAC 60 A WISER CONTROL RELAY (QO260PWX240) F RONT APPEARANCE F IGURE 2 240 VAC 60 A WISER CONTROL RELAY (QO260PWX240) BACK APPEARANCE Appendix II Page 3 of 8 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F23158 FIGURE 3 240 VAC 60 A WISER CONTROL RELAY (QO260PWX240) L EFT F IGURE 4 240 VAC 60 A WISER CONTROL RELAY (QO260PWX240) RIGHT Appendix II Page 4 of 8 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F23158 FIGURE 5 240 VAC 60 A WISER CONTROL RELAY (QO260PWX240) T OP F IGURE 6 240 VAC 60 A WISER CONTROL RELAY (QO260PWX240) BOTTOM

ID Label/Location Info

Label Location: Label CC G F E D B A H I J D E F G H I J 12345678 ANY PRINTED COPY OF THIS DOCUMENT USED WITHIN SCHNEIDER ELECTRIC IS CONSIDERED UNCONTROLLED. PRINTS State: Number: Revision: Sheet: Scale: Tolerancing Standard : Units of measure : The information is highly confidential and is the exclusive property of Schneider Electric Group copyright reserved. This drawing must not be used for any purpose other than that expressly permitted in writing by the owners and must not be disclosed or reproduced in any way without permission from the owners in writing. This drawing must be returned to the owners when the purpose has ceased. [mm] INCH 1:1 S1A1793900 FACEPLATE LABEL FACEPLATE LABEL BQT2512801 00 1/1 QO260PWX240 MODULE INPUT: 120VAC 60Hz LOAD INPUT: 240VAC 60Hz LOAD OUTPUT: 240VAC 60A / 3HP MAX LOAD TYPE: RES, MOTOR #14-4 AWG Min. 90°C CU ONLY SQUARE D Control Relay LISTED E523609 Type QO Home Automation Equipment Indoor use unless installed in a NEMA 3R rated enclosure FCC ID: PUU-QO260PWX IC: 10798A-QO260PWX S3-30°C to 50°C CUT LINE BLACKWHITE [45.72] 1.8 [70.4] 2.8

Internal Photos

Appendix II Page 5 of 8 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F23158 FIGURE 7 240 VAC 60 A WISER CONTROL RELAY (QO260PWX240) C OVER REMOVE F IGURE 8 240 VAC 60 A WISER CONTROL RELAY (QO260PWX240) MAINBOARD FRONT Appendix II Page 6 of 8 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F23158 FIGURE 9 240 VAC 60 A WISER CONTROL RELAY (QO260PWX240) M AINBOARD BACK F IGURE 10 240 VAC 60 A WISER CONTROL RELAY (QO260PWX240) CHIP&CRYSTAL ON MAINBOARD Appendix II Page 7 of 8 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F23158 FIGURE 11 240 VAC 60 A WISER CONTROL RELAY (QO260PWX240) RF BOARD FRONT F IGURE 12 240 VAC 60 A WISER CONTROL RELAY (QO260PWX240) RF BOARD BACK Appendix II Page 8 of 8 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F23158 FIGURE 13 240 VAC 60 A WISER CONTROL RELAY (QO260PWX240) C HIP&CRY S TA L ON RF BOARD F IGURE 14 240 VAC 60 A WISER CONTROL RELAY (QO260PWX240) RF BOARD Antenna

RF Exposure Info

Savant Technologies LLC, dba GE Lighting, a Savant company FCC ID: PUU-QO260PWX Page 1 of 2 Audix Technology (Shanghai) Co., Ltd. RADIO FRREQUENCY EXPOSURE EVALUATION Evaluation Method: KDB 447498 D01 v6 Applicable Standard: FCC CFR 47§1.1310 : Radiofrequency radiation exposure limits. Note: (1) Occupational/controlled exposure limits apply in situations in which persons are exposed as a consequence of their employment provided those persons are fully aware of the potential for exposure and can exercise control over their exposure. Limits for occupational/controlled exposure also apply in situations when a person is transient through a location where occupational/controlled limits apply provided he or she is made aware of the potential for exposure. (2) General population/uncontrolled exposure limits apply in situations in which the general public may be exposed, or in which persons who are exposed as a consequence of their employment may not be fully aware of the potential for exposure or cannot exercise control over their exposure. MPE Calculation Standard: MPE(S) = PG/(4휋푅 2 ) where: S = power density (in appropriate units, e.g. mW/ cm 2 ) P = power input to the antenna (in appropriate units, e.g., mW) G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna (appropriate units, e.g., cm) Savant Technologies LLC, dba GE Lighting, a Savant company FCC ID: PUU-QO260PWX Page 2 of 2 Audix Technology (Shanghai) Co., Ltd. Calculation Result: For this EUT, General population/uncontrolled exposure limits applied. The limit value 1.0mW/cm 2 is available for this EUT. The Evaluation distance (R) = 20cm. The Data derived from the RF test report. Modulation Peak Output Power Antenna Gain MPE Limit Verdict (dBm) (mW) (dBi) (Numeric) (mW/cm 2 ) (mW/cm 2 ) ZigBee -0.936 0.806 1.49 1.409 0.0002 1.0 Compliant

Test Report

Antenna Specification Manufacture Savant Technologies LLC, dba GE Lighting, a Savant company Address 1975 Noble Road, Cleveland, OH 44112 Model GEL_52840 Operating Band 2400~2483.5MHz Antenna Type inverted F PCB antenna Polarization Linear Impedance 50Ω Antenna peak gain 1.49dBi Antenna picture (unit: mm) Antenna pattern (2D/3D)

Test Report

Savant Technologies LLC, dba GE Lighting, a Savant company FCC ID: PUU-QO260PWX Page 1 of 48 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F23158 Prepared For: Savant Technologies LLC, dba GE Lighting, a Savant company 1975 Noble Road, Cleveland, OH 44112 Prepared By: Audix Technology (Shanghai) Co., Ltd. 3F, Building 34, No. 680 Guiping Rd., Caohejing, Hi-Tech Park, Shanghai 200233, China Tel: +86-21-64955500 File No. : C1D2307048 Report No. : ACI- F23158 Date of Test : 2023.07.20-24 Date of Report : 2023.08.18 TEST REPORT On behalf of Savant Technologies LLC, dba GE Lighting, a Savant company Product Name: 240 Vac 60 A Wiser Control Relay Model No.: QO260PWX240 FCC ID: PUU-QO260PWX The statement is based on a single evaluation of one sample of the above-mentioned products. It does not imply an assessment of the whole production and does not permit the use of the test lab logo. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Government. TESTING NVLAP LAB CODE 200371-0 Savant Technologies LLC, dba GE Lighting, a Savant company FCC ID: PUU-QO260PWX Page 2 of 48 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F23158 TABLE OF CONTENTS Page 1 SUMMARY OF STANDARDS AND RESULTS .......................................................................... 5 1.1 Description of Standards and Results ......................................................................................... 5 2 GENERAL INFORMATION .......................................................................................................... 6 2.1 Description of Equipment Under Test ........................................................................................ 6 2.2 EUT Specifications Assessed in Current Report ........................................................................ 7 2.3 Test Information ......................................................................................................................... 7 2.4 Duty Cycle Check ...................................................................................................................... 7 2.5 Sample Description .................................................................................................................... 8 2.6 Supported equipment .................................................................................................................. 8 2.7 Description of Test Facility ........................................................................................................ 8 3 CONDUCTED EMISSION TEST .................................................................................................. 9 3.1 Test Equipment........................................................................................................................... 9 3.2 Block Diagram of Test Setup ..................................................................................................... 9 3.3 Conducted Emission Limits (§15.207) ..................................................................................... 10 3.4 Test Configuration .................................................................................................................... 10 3.5 Operating Condition of EUT .................................................................................................... 10 3.6 Test Procedures ........................................................................................................................ 10 3.7 Test Results .............................................................................................................................. 11 4 RADIATED EMISSION TEST ..................................................................................................... 14 4.1 Test Equipment......................................................................................................................... 14 4.2 Block Diagram of Test Setup ................................................................................................... 15 4.3 Radiated Emission Limit (§15.209) ......................................................................................... 16 4.4 Test Configuration .................................................................................................................... 16 4.5 Operating Condition of EUT .................................................................................................... 16 4.6 Test Procedures ........................................................................................................................ 16 4.7 Test Results .............................................................................................................................. 18 5 6 DB BANDWIDTH MEASUREMENT ...................................................................................... 31 5.1 Test Equipment......................................................................................................................... 31 5.2 Block Diagram of Test Setup ................................................................................................... 31 5.3 Specification Limits (§15.247(a)(2)) ........................................................................................ 31 5.4 Operating Condition of EUT .................................................................................................... 31 5.5 Test Procedure .......................................................................................................................... 31 5.6 Test Results .............................................................................................................................. 32 6 MAXIMUM PEAK OUTPUT POWER MEASUREMENT ...................................................... 34 6.1 Test Equipment..............................................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Appendix I Page 1 of 5 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F23158 APPENDIX I P HOTOGRAPHS OF TEST Appendix I Page 2 of 5 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F23158 Test Set-Up Photos 1. Conducted Test FRONT VIEW BACK VIEW Appendix I Page 3 of 5 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F23158 2. Radiated Test (BELOW 1GHZ) FRONT (B ELOW 1GHZ) BACK Appendix I Page 4 of 5 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F23158 (ABOVE 1GHZ) FRONT (A BOVE 1GHZ) BACK Appendix I Page 5 of 5 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F23158 3. Antenna-port Conducted Test

Contact Information

Applicant

Paul Smith(Systems Engineer - Safety & Regulatory)
[email protected]2162662189Fax: 2162663003

Test Firm

Audix Technology (Shanghai) Co., Ltd.Kathy Wang
[email protected]86-21-64955500Fax: 86-21-64955491

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz800.00 µW
Confidentiality
Long Term
Grant Notes
Output power is conducted. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Savant Technologies LLC, dba GE Lighting, a Savant Company

Dual sockets indoor plug - FCC ID PUU-CPLGID2BLW1 - Savant Technologies LLC, dba GE Lighting, a Savant Company
PUU-CPLGID2BLW1

Dual sockets indoor plug

Aug 05, 2026

Equipment Class

DTS - Digital Transmission System
CYNC Shoplight - FCC ID PUU-CFIXSHP46 - Savant Technologies LLC, dba GE Lighting, a Savant Company
PUU-CFIXSHP46

CYNC Shoplight

Jul 31, 2026

Equipment Class

DTS - Digital Transmission System
PUU-STR-CBDMI

Cync Direct Connect Strip

Jul 30, 2026

Equipment Class

DTS - Digital Transmission System
PUU-GEL-HAL

PROSEO Sage LF module

May 19, 2026

Equipment Class

DTS - Digital Transmission System
Fan Switch - FCC ID PUU-CSWFSBLK3T1 - Savant Technologies LLC, dba GE Lighting, a Savant Company
PUU-CSWFSBLK3T1

Fan Switch

Sep 04, 2025

Equipment Class

DTS - Digital Transmission System