GE Connected Full Color CLEDST196CDGS, input 120Vac, frequency was 60Hz, high efficiency, safety & stability output. Use Bluetooth 5.0 and Wi-Fi 2.4G Hz chip technology to realize the far distance control. Through the APP to control the PWM signal to dim and even control the switch on & off of the bulb. Product features: 1. Controlled by Bluetooth 5.0 and 2.4G Wi-Fi to realize the far distance control. 2. CCT is 2700K, 2000K-7000K, millions of colors. 3. With advanced chips to make sure the bulb with high efficiency, low consumption and stability. 4. Internal constant current output to make sure the high power conversion efficiency and stability output. Product Name LED LAMP Brand Name GE Model No. CLEDST196CDGS@, @ rates for package information, maybe 1P~10P Working Voltage 120Vac Bluetooth Specification Version 5.0 Wi-Fi Specification 2.4G Hz Frequency Range 2400- 2483.5MHz Channel Number Bluetooth 40 Channel Separation Bluetooth 2MHz Type of Modulation Bluetooth GFSK Data Rate Bluetooth 1Mbps(GFSK)οΌ2Mbps,512Kbps Channel Number Wi-Fi 11 Channel Separation Wi-Fi 5MHz Data Rate Wi-Fi 802.11b:11, 5.5,2,1 Mbps 802.11g: 54,48,36,24,18,12,9,6 Mbps 802.11n: up to 20Mbps Antenna Type Microstrip line antenna Peak Antenna Gain Bluetooth 1.3dBi Peak Antenna Gain Wi-Fi 1.3dBi For additional help, regulatory and safety Information, please go to: Federal Communications Commission (FCC) Interference Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation. The grantee is not responsible for any changes or modifications not expressly approved by the party responsible for compliance. Such modifications could void the userβs authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance of 20 cm between the radiator and your body. CAUTION: - DO NOT USE WITH STANDARD DIMMERS, SEE INSTRUCTIONS -NOT FOR USE IN TOTALLY ENCLOSED LUMINAIRES -SUITABLE FOR DAMP LOCATIONS -THIS DEVICE IS NOT INTENDED FOR USE WITH EMERGENCY EXITS Only use the control provided with or specified by these instructions to control this lamp. This lamp will not operate properly when connected to a standard (incandescent) dimmer or dimming control. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le prΓ©sent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisΓ©e aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioΓ©lectrique subi, mΓͺme si le brouillage est susceptible d'en compromettre le fonctionnement. Radiation Exposure Statement: This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator & your body. DΓ©claration d'exposition aux radiations: Cet Γ©quipement est conforme aux limites d'exposition aux rayonnements IC Γ©tablies pour un environnement non contrΓ΄lΓ©. Cet Γ©quipement doit Γͺtre installΓ© et utilisΓ© avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps.
Savant Technologies LLC, dba GE Lighting, a Savant company To: Federal Communications Commission Date: 2024/01/17 7435 Oakland Mills Road Columbia, MD 21046 USA Attestation Certification designating a U.S. Agent for Service of Process Section 2.911(d)(7) (KDB 986446 D01 Covered Equipment) Savant Technologies LLC, dba GE Lighting, a Savant company (βthe applicantβ) as required by section 2.911(d)(7), designate below contact located in the United States for purposes of acting as the applicantβs agent for service of process. The applicant also acceptance to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission- related proceeding involving the equipment. Type of Equipment subject to FCC Certification: LED LAMP FCC ID: PUU-ST19-DMFCI / PUU-G25-DMFCI PUU-ST19-DMSWI / PUU-G25-DMSWI Sincerely yours, Applicant/Grantee US Agent FRN: 0022026876 FRN: 0022026876 _________________ ___________________ Savant Technologies LLC, dba Savant Technologies LLC, dba GE Lighting, a Savant company GE Lighting, a Savant company Paul Smith Paul Smith Systems Engineer - Safety & Regulatory Systems Engineer - Safety & Regulatory [email protected] [email protected] 1975 Noble Road , Cleveland , 1975 Noble Road , Cleveland , Ohio, United States 44112 Ohio, United States 44112
Savant Technologies LLC, dba GE Lighting, a Savant company To: Federal Communications Commission Date: 2024/01/17 7435 Oakland Mills Road Columbia, MD 21046 USA Attestation Section 2.911(d)(5)(i) and Section 2.911(d)(5)(ii) (KDB 986446 D01 Covered Equipment) Section 2.911(d)(5)(i) Savant Technologies LLC, dba GE Lighting, a Savant company certifies that the equipment for which authorization is sought is not βcoveredβ equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Section 2.911(d)(5)(ii) Savant Technologies LLC, dba GE Lighting, a Savant company certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing βcoveredβ equipment. Type of Equipment subject to FCC Certification: LED LAMP FCC ID: PUU-ST19-DMFCI If you have any questions, please feel free to contact me Contact Person: Paul Smith Position in the Company: Systems Engineer - Safety & Regulatory Date of Signature: 2024-01-17 ___________________________ Signatory (signature of the applicant)
Savant Technologies LLC, dba GE Lighting, a Savant company Date:2024-01-17 To: Federal Communications Commission, Authorization & Evaluation Division, 7435 Oakland Mills Road, Columbia, MD 21046 Re: Request of Confidentiality for FCC ID: PUU-ST19-DMFCI To Whom it may concern: Pursuant to sections 0.457 and 0.459 of Commissionβs Rules(CFR 47), and Section 552(b)(4) of the Freedom of Information Act, Savant Technologies LLC, dba GE Lighting, a Savant company hereby requests confidentiality and treatment of certain information accompanying this application. The materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. We are also hereby request Short-Term Confidentiality for 180 days from grant date as outlined in Public Notice DA04-1705. This provision will give Savant Technologies LLC, dba GE Lighting, a Savant company temporary confidentiality of commercially sensitive information prior to product release. The requested Permanent and Short-Term Confidential exhibits are listed as follows: The Applicant understands that pursuant to Rule 0.457, disclosure of this application and all accompanying documentations, where applicable, will not be made public before the date of the Grant for this application. NameοΌPaul Smith Company nameοΌSavant Technologies LLC, dba GE Lighting, a Savant company AddressοΌ1975 Noble Road , Cleveland , Ohio, United States 44112 TelοΌ2162662189 EmailοΌ[email protected]
Savant Technologies LLC, dba GE Lighting, a Savant company Date: 2024/01/17 To: Federal Communications Commission, Authorization & Evaluation Division, 7435 Oakland Mills Road, Columbia, MD 21046 To Whom It May Concern: The Savant Technologies LLC, dba GE Lighting, a Savant company, the undersigned, hereby authorizes Mrs. Wendy Zhan from Shenzhen Morlab Communications Technology Co., Ltd., to act on the behalf of the Savant Technologies LLC, dba GE Lighting, a Savant company solely in matters relating to the application for an FCC equipment authorization for FCC ID: PUU-ST19-DMFCI including the signing of documents in connection with this Application. Necessary acts carried out Shenzhen Morlab Communications Technology Co., Ltd. on our behalf of the Savant Technologies LLC, dba GE Lighting, a Savant company in connection with the Application shall have the same effect as acts of the Savant Technologies LLC, dba GE Lighting, a Savant company. Savant Technologies LLC, dba GE Lighting, a Savant company also hereby certify that no party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Thank you for your attention to this matter. Yours Sincerely, Contact name: Paul Smith Title: Systems Engineer - Safety & Regulatory Tel: 2162662189 Email: [email protected] Company name: Savant Technologies LLC, dba GE Lighting, a Savant company
Savant Technologies Llc, dba Ge lighting, a Savant Company Savant Technologies Llc, dba Ge lighting, a Savant Company Confirmation Letter We, Savant Technologies Llc, dba Ge lighting, a Savant Company declare that for Product name: LED LAMP Model CLEDST196CDGS CLEDG256CDGS CLEDST196LDGF CLEDG256LDGF only have differences in appearance , model, the mechanism of the filament, LED (light source), and dimmable (color temperature) of the product. Except for the differences shown above. Their electrical circuit design, layout, components used and internal wiring are identical. No other changes. Date: 2024-02-06 City: America Name: Paul Smith Signature:
Savant Technologies LLC, dba GE Lighting, a Savant company Ad-Hoc Country Code Cover Letter We, <Savant Technologies LLC, dba GE Lighting, a Savant company>, declare that this EUT (FCC ID: PUU-ST19-DMFCI, IC IDοΌ10798A-DMFCST19I) doesnβt have Ad Hoc Mode function on βnon-US/Canada frequenciesβ. In addition, the frequency selection feature is disable by firmware for device marketed to the US/Canada. For DTS part of this device, only channel 1~11 will be used in North America. Country code selection is disabled. Should you have any questions or comments regarding this matter, please have my best attention. Sincerely yours, Paul Smith Company nameοΌSavant Technologies LLC, dba GE Lighting, a Savant company Tel: 2162662189 Fax: 2162663003 Email: [email protected]
FCC ID: PUU-ST19-DMFCI IC: 10798A-DMFCST19I External Photos 1. EUT front view 2. EUT rear view 3. EUT left side view 4. EUT right side view 5. EUT top view 6. EUT bottom view
15+-2mm 29mm 5mm YNC β’ Soft White 5mm 1mm 1.6mm C ID Arial narrow,5pt/1.3mm FCC ID:PUU-ST19-DMFCI IC:10798A-DMFCST19I HVIN:CLEDST196CDGSA MADE IN CHINA YYDDDTS 500 LUMENS 6.2W 80mA 120V 60Hz 2700K-7000K CLEDST196CDGS LED LAMP 4US7 Patents: gelighting.com/patents DO NOT USE WITH STANDARD DIMMERS,SEE INSTRUCTIONS -NOT FOR TOTALLY ENCLOSED OR RECESSED LUMINAIRES -FOR DAMP LOCATIONS.NE PAS UTILISER AVEC DES GRADATEURS STANDARD. SE REPORTER AUX INSTRUCTIONS -NE PAS UTILISER DANS UN LUMINAIRE ENCASTRE OU FERME-CONVIENT AUX EMPLACEMENTS HUMIDES Direct Conne ct
FCC ID: PUU-ST19-DMFCI IC: 10798A-DMFCST19I Internal Photos 1. EUT uncover view 2. Antenna view Bluetooth/2.4G WIFI Antenna
NOTE: This document is issued by Shenzhen Morlab Communications Technology Co., Ltd., the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 1 of 8 REPORT No.οΌSZ23100319S01 RF EXPOSURE EVALUATION REPORT APPLICANT : Savant Technologies Llc, dba Ge lighting, a Savant Company PRODUCT NAME : LED LAMP MODEL NAME : CLEDST196CDGS BRAND NAME : GE FCC ID : PUU-ST19-DMFCI STANDARD(S) : 47 CFR Part 2(2.1091) RECEIPT DATE : 2023-12-04 TEST DATE : 2023-12-06 to 2023-12-27 ISSUE DATE : 2024-01-31 Edited by: Zeng Xiaoying (Rapporteur) Approved by: Shen Junsheng (Supervisor) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.οΌSZ23100319S01 Page 2of 8 DIRECTORY 1. Technical Information ββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 3 1.1 Applicant and Manufacturer Information βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 3 1.2 Equipment under Test (EUT) Description ββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 3 1.3 Applied Reference Documents βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 4 2. Device Category and RF Exposure Limit βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 5 3. Maximum Average Power Summary βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 6 4. RF Exposure Assessment ββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 7 Annex A Testing Laboratory Information βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ 8 Change History Version Date Reason for change 1.0 2024-01-31 First edition MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.οΌSZ23100319S01 Page 3of 8 1. Technical Information Note: Provide by applicant. 1.1 Applicant and Manufacturer Information Applicant: Savant Technologies Llc, dba Ge lighting, a Savant Company Applicant Address: 1975 Noble Road Cleveland Ohio United States 44112 Manufacturer: Xiamen Topstar lighting Co.,Ltd. Manufacturer Address: 676 Meixi Avenue,Tong'an District,Xiamen,China 1.2 Equipment under Test (EUT) Description Product Name: LED LAMP Sample No.: 6# Hardware Version: 1 Software Version: V11004 Modulation Technology: Bluetooth GFSK WLAN 2.4GHz DSSS, OFDM Operating Frequency Range: Bluetooth 2402MHz-2480MHz WLAN 2.4GHz 2412MHz-2462MHz Antenna Type: Microstrip Line Antenna Antenna Gain: 1.3dBi MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.οΌSZ23100319S01 Page 4of 8 1.3 Applied Reference Documents Leading reference documents for testing: Identity Document Title Method determination /Remark 47 CFR Part 2(2.1091) Radio Frequency Radiation Exposure Assessment: mobile devices No deviation KDB 447498 D01v06 General RF Exposure Guidance No deviation Note 1: Additions to, deviation, or exclusions from the method shall be judged in the "method determination" column of add, deviate or exclude from the specific method shall be explained in the "Remark" of the above table. Note 2: When the test result is a critical value, we will use the measurement uncertainty give the judgment result based on the 95% confidence intervals. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.οΌSZ23100319S01 Page 5of 8 2. Device Category and RF Exposure Limit Per user manual, based on 47 CFR 2.1091, this device belongs to mobile device category with General Population/Uncontrolled exposure. Mobile Devices: 47 CFR 2.1091(b) For purposes of this section, a mobile device is defined as a transmitting device designed to be used in other than fixed locations and to generally be used in such a way that a separation distance of at least 20 centimeters is normally maintained between the transmitter's radiating structure(s) and the body of the user or nearby persons. In this context, the term βfixed locationβ means that the device is physically secured at one location and is not able to be easily moved to another location. Transmitting devices designed to be used by consumers or workers that can be easily re-located, such as wireless devices associated with a personal computer, are considered to be mobile devices if they meet the 20 centimeter separation requirement. General Population/Uncontrolled Exposure: The general population/uncontrolled exposure limits are applicable to situations in which the general public may be exposed or in which persons who are exposed as a consequence of their employment may not be made fully aware of the potential for exposure or cannot exercise cβ¦
Text truncated - open the document above for the full version.
ANTENNA SPECIFICATIONS Item Specifications Antenna Frequency Range 2400~2483.5MHz Polarization Linear Peak Gain 1.3dBi V.S.W.R 1.32~1.49 Impedance 50Ξ© Return Loss -12~-17dB Connector External antenna Efficiency 26.9% Type External antenna Size 28x1.15mm Antenna typeοΌATWE-11 -0008-060 ProducerοΌ Shenzhen Jingxun Technology Co. , Ltd. AddressοΌ3/F,A5 Building Zhiyuan Community No.1001,Xueyuan Road Nanshan District,Shenzhen City ANTENNA PATTERN Antenna PictureοΌ
NOTE: This document is issued by Shenzhen Morlab Communications Technology Co., Ltd., the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 1 of 93 REPORT No.οΌSZ23100319W01 TEST REPORT APPLICANT : Savant Technologies Llc, dba Ge lighting, a Savant Company PRODUCT NAME : LED LAMP MODEL NAME : CLEDST196CDGS BRAND NAME : GE FCC ID : PUU-ST19-DMFCI STANDARD(S) : 47 CFR Part 15 Subpart C RECEIPT DATE : 2023-12-04 TEST DATE : 2023-12-06 to 2023-12-27 ISSUE DATE : 2024-01-31 Edited by: Zeng Xiaoying (Rapporteur) Approved by: Shen Junsheng (Supervisor) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 2 of 93 REPORT No.οΌSZ23100319W01 DIRECTORY 1. Summary of Test Result κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 4 1.1. Testing Applied Standards κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 5 1.2. Test Equipment List κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 6 1.3. Measurement Uncertainty κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 8 1.4. Testing Laboratory κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 8 2. General Description κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 9 2.1. Information of Applicant and Manufacturer κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 9 2.2. Information of EUT κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 9 2.3. Channel List of EUT κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 10 2.4. Test Configuration of EUT κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 11 2.5. Test Conditions κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 11 2.6. Test Setup Layout Diagram κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 11 3. Test Results κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 14 3.1. Antenna Requirement κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 14 3.2. Duty Cycle of Test Signal κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 15 3.3. Maximum Peak Conducted Output Power κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 16 3.4. Maximum Average Conducted Output Power κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 17 3.5. 6 dB Bandwidth κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 18 3.6. Conducted Spurious Emissions and Band Edge κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 19 3.7. Power Spectral Density κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 20 3.8. Conducted Emission κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 21 3.9. Restricted Frequency Bands κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 22 3.10. Radiated Emission κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 23 Annex A Test Data and Result κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 25 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 3 of 93 REPORT No.οΌSZ23100319W01 Change History Version Date Reason for change 1.0 2024-01-31 First edition MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 4 of 93 REPORT No.οΌSZ23100319W01 1. Summary of Test Result No. Section Description Test Date Test Engineer Result Method Determination /Remark 1 15.203 Antenna Requirement N/A N/A PASS No deviation 2 N/A Duty Cycle of Test Signal Dec. 06&14, 2023 He Yuyang PASS No deviation 3 15.247(b) Maximum Peak Conducted Output Power Dec. 06&14, 2023 He Yuyang PASS No deviation 4 15.247(b) Maximum Average Conducted Output Power Dec. 06&14, 2023 He Yuyang PASS No deviation 5 15.247(a) Bandwidth Dec. 06&14, 2023 He Yuyang PASS No deviation 6 15.247(d) Conducted Spurious Emission and Band Edge Dec. 06&14, 2023 He Yuyang PASS No deviation 7 15.247(e) Power Spectral Density Dec. 06&14, 2023 He Yuyang PASS No deviation 8 15.207 Conducted Emission Dec. 12, 2023 Fan Zehang PASS No deviation 9 15.247(d) Restricted Frequency Bands Dec. 20, 2023 Lin Hanbin PASS No deviation 10 15.209, 15.247(d) Radiated Emission Dec. 20, 2023 Lin Hanbin PASS No deviation Note 1: The tests were performed according to the method of measurements prescribed in ANSI C63.10-2013 and KDB 558074 D01 v05r02. Note 2: Additions to, deviation, or exclusions from the method shall be judged in the "method determination" column of add, deviate or exclude from the specific method shall be explained in the "Remark" of the above table. Note 3: When the test result is a critiβ¦
Text truncated - open the document above for the full version.
NOTE: This document is issued by Shenzhen Morlab Communications Technology Co., Ltd., the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 1 of 109 REPORT No.οΌSZ23100319W02 TEST REPORT APPLICANT : Savant Technologies Llc, dba Ge lighting, a Savant Company PRODUCT NAME : LED LAMP MODEL NAME : CLEDST196CDGS BRAND NAME : GE FCC ID : PUU-ST19-DMFCI STANDARD(S) : 47 CFR Part 15 Subpart C RECEIPT DATE : 2023-12-04 TEST DATE : 2023-12-06 to 2023-12-27 ISSUE DATE : 2024-01-31 Edited by: Zeng Xiaoying (Rapporteur) Approved by: Shen Junsheng (Supervisor) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 2 of 109 REPORT No.οΌSZ23100319W02 DIRECTORY 1. Summary of Test Result κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 4 1.1. Testing Applied Standards κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 5 1.2. Test Equipment List κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 6 1.3. Measurement Uncertainty κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 8 1.4. Testing Laboratory κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 8 2. General Description κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 9 2.1. Information of Applicant and Manufacturer κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 9 2.2. Information of EUT κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 9 2.3. Channel List of EUT κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 10 2.4. Test Configuration of EUT κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 11 2.5. Test Conditions κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 11 2.6. Test Setup Layout Diagram κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 12 3. Test Results κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 15 3.1. Antenna Requirement κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 15 3.2. Duty Cycle of Test Signal κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 16 3.3. Maximum Peak and Average Conducted Output Power κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 17 3.4. 6 dB Bandwidth κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 18 3.5. Conducted Spurious Emissions and Band Edge κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 19 3.6. Power Spectral Density κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 20 3.7. Conducted Emission κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 21 3.8. Restricted Frequency Bands κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 22 3.9. Radiated Emission κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 23 Annex A Test Data and Result κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 25 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 3 of 109 REPORT No.οΌSZ23100319W02 Change History Version Date Reason for change 1.0 2024-01-31 First edition MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 4 of 109 REPORT No.οΌSZ23100319W02 1. Summary of Test Result No. Section Description Test Date Test Engineer Result Method Determination /Remark 1 15.203 Antenna Requirement N/A N/A PASS No deviation 2 N/A Duty Cycle of Test Signal Dec. 14, 2023 He Yuyang PASS No deviation 3 15.247(b) Maximum Peak Conducted Output Power Dec. 06&14, 2023 He β¦
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15C | 2.41 GHz - 2.46 GHz | 263.63 mW |

Dual sockets indoor plug
Equipment Class
DTS - Digital Transmission System
CYNC Shoplight
Equipment Class
DTS - Digital Transmission SystemCync Direct Connect Strip
Equipment Class
DTS - Digital Transmission SystemPROSEO Sage LF module
Equipment Class
DTS - Digital Transmission System
Fan Switch
Equipment Class
DTS - Digital Transmission System