FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Savant Technologies LLC, dba GE Lighting, a Savant Company/
  3. PUU-STR-CBDM

PUU-STR-CBDMCync Direct Connect Strip

Savant Technologies LLC, dba GE Lighting, a Savant Company
Cync Direct Connect Strip - FCC ID PUU-STR-CBDM - Savant Technologies LLC, dba GE Lighting, a Savant Company
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Apr 17, 2024
Application Purpose
Original Equipment
Date of Application
Apr 17, 2024
Equipment Note
Cync Direct Connect Strip
Frequency Range
2412.00000000 - 2462.00000000
Company
Savant Technologies LLC, dba GE Lighting, a Savant Company
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Operational Description

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Savant Technologies LLC, dba GE Lighting, a Savant company Covered Equipment Certification Attestation Letter COMPANY Letterhead: 4/15/2024 Nemko North America, Inc. 303 River Road Ottawa K1V 1H2 Canada ATTN.: Reviewing Engineer FCC ID: PUU-STR-CBDM Savant Technologies LLC, dba GE Lighting, a Savant company (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Note: If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, the applicant should include an explanation on why the equipment is not “covered” equipment. Savant Technologies LLC, dba GE Lighting, a Savant company (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Signed: Printed name: Paul Smith Title: Systems Engineer – Safety & Regulatory Company Name: Savant Technologies LLC, dba GE Lighting, a Savant company Date: 4/11/2024

Attestation Statements

Savant Technologies LLC, dba GE Lighting, a Savant company * the applicant must designate a contact located in the United States for purposes of acting as the applicant’s agent for service of process, regardless of whether the applicant is a domestic or foreign entity. An applicant located in the United States may designate itself as the agent for service of process. U.S. Agent Designation for Service of Process - Certification Attestation Letter DATE Nemko North America, Inc. 303 River Road Ottawa K1V 1H2 Canada ATTN.: Reviewing Engineer FCC ID: PUU-STR-CBDM Per section 2.911(d)(7) of the FCC rules, Savant Technologies LLC, dba GE Lighting, a Savant company (“the applicant”) certifies that the equipment for which authorization is sought is designated to the following U.S. agent* for service of process: Company Name: Savant Technologies LLC, dba GE Lighting, a Savant company Physical U.S. Company Address: 1975 Noble Road, East Cleveland, Ohio 44112 Agent name: Paul Smith Agent Email Address: [email protected] The above contact person accepts the obligation for service of process. The applicant accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Applicant Signed: Agent Signed (if different to Applicant): Signed: Signed: Printed name: Paul Smith Printed name: Click here to enter text. Title: Systems Engineer – Safety & Regulatory Title: Click here to enter text. Company Name: GE Lighting, a Savant company Company Name: Click here to enter text. Date: 4/2/2024 Date: Click here to enter a date.

Cover Letter(s)

Savant Technologies LLC, dba GE Lighting, a Savant company 4/2/2024 Nemko North America, Inc. 303 River Road Ottawa, Ontario, Canada K1V 1H2 AUTHORITY TO ACT AS AGENT - FCC On our behalf, I appoint DEKRA Testing and Certification (Shanghai) Ltd. Guangzhou Branch, to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in FCC regulations will have affixed to it a label identical to that submitted for approval with this application. In signing this letter, Applicant certifies that neither the applicant nor any party to the application is not subject to a denial of Federal benefits, that include FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. § 862 because of a conviction for possession or distribution of a controlled substance. See 47 CFR 1.2002(b) for the definition of a "party" for these purposes. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, as specified by Nemko North America Inc., still resides still resides with us. Sincerely, Printed name: Paul Smith

Cover Letter(s)

Savant Technologies LLC, dba GE Lighting, a Savant company Family Certification Attestation Letter DATE Nemko Canada Inc 303 River Road Ottawa K1V 1H2 Canada ATTN.: Reviewing Engineer FCC ID: PUU-STR-CBDM Models: CSTR16CBDM, CSTR32CBDM We hereby request Family Certification for the above-mentioned Models based on them being electrically identical. The controller boxes of both models are the same and are made of ABS material, which has no effect on RF characteristics. Signed: Printed name: Paul Smith Title: Systems Engineer – Safety & Regulatory Date: 4/12/2024

Cover Letter(s)

Savant Technologies LLC, dba GE Lighting, a Savant company 4/16/2024 Nemko North America, Inc. 303 River Road Ottawa, Ontario, Canada K1V 1H2 REQUEST FOR CONFIDENTIALITY - FCC FCC ID: PUU-STR-CBDM Pursuant to Sections 0.457(d)(1)(ii) and 0.459 of the Commission’s Rules and FCC Guidance document 726920, we hereby request confidential treatment of information accompanying this application as outlined below: PERMANENT LONG-TERM CONFIDENTIALITY: Schematics Block Diagrams Theory of Operation SHORT TERM CONFIDENTIALITY FOR A PERIOD OF 180 DAYS (Note: for the X number of days, you can list up to 180 days, but should not go past the date you start product marketing/sale): Internal Photos External Photos User Manual Test Set-up Photographs When the device is marketed before the requested number of days listed above, the grantee will inform the TCB to release the Short-Term Confidentiality information withheld on the FCC equipment authorization website. The above information contains trade secrets and proprietary information not customarily released to the public. The public disclosure of this information might be harmful to the applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457(d)(1)(ii), disclosure of this Application and all accompanying materials will not be made before the date of the Grant for this Application. Sincerely, Signed: Printed name: Paul Smith Title: Systems Engineer – Safety & Regulatory

External Photos

CSTR16CBDM: Overall view Front view Rear view Side view Side view Side view Side view Front view Rear view Side view Side view Side view CSTR32CBDM: Overall view Front view Rear view Side view Side view Side view Side view Front view Rear view Side view Side view Side view Side view

ID Label/Location Info

Direct Connect Indoor Light Strip 68 mm 36 mm Model No.: CSTR16CBDM IC: 10798A-STRCBDM FCC ID: PUU-STR-CBDM Made in China 23336FL GM 13 mm 13 mm 42 mm 12 mm Input: 24V 0.5A 2.5 mm 1.9 mm 2 mm CYNC Direct Connect Indoor Light Strip 8 mm 21 mm 8.6 mm 8.6 mm 10.00 mm 2.2 mm 14 mm 6 mm - - 33.00 mm 12 mm 5 mm 2 mm

ID Label/Location Info

5 mm 2 mm Direct Connect Indoor Light Strip 68 mm 36 mm Model No.: CSTR32CBDM IC: 10798A-STRCBDM FCC ID: PUU-STR-CBDM Made in China 23336FL GM 13 mm 13 mm 42 mm 12 mm Input: 24V 0.5A 2.5 mm 1.9 mm 2 mm CYNC Direct Connect Indoor Light Strip 8 mm 21 mm 8.6 mm 8.6 mm 10.00 mm 2.2 mm 14 mm 6 mm - - 33.00 mm 12 mm

Internal Photos

CSTR32CBDM: Controller Controller Internal view Control PCB Control PCB LED driver LED driver Internal view Drive PCB Driver PCB CSTR16CBDM Controller Controller Internal view Control PCB Control PCB LED driver LED driver LED driver PCB LED driver PCB

Operational Description

ANTENNASPECIFICATIONS ItemSpecifications Antenna FrequencyRange2400~2483.5MHz PolarizationLinear PeakGain0.5dBi V.S.W.R < 2.0 Impedance50Ω ReturnLoss-10dB ConnectorMicrostriplineconnection Efficiency 25% Type Onboard:ANT0 Size 12.5x6.5mm Manufacturer ShenzhenJingxunTechologyLimited Co.,Ltd Manufactureraddress 3/F,A5BuildingZhiyuanCommunityNo.1001, XueyuanRoad,NanshanDistrict,Shenzhen City,China EnvironmentalOperatingTemperature-40°C~+105°C ANTENNAPATTERN AntennaPicture :

RF Exposure Info

DEKRA Testing and Certification (Shanghai) Ltd. Guangzhou Branch Block 5, No.3, Qiyun Road, Huangpu District, Guangzhou, Guangdong, China Tel +86 20 6661 2000 Fax +86 20 6661 2001 https://www.dekra.comv Report no.: 4915190.55 Page 1 / 10 Test report No: 4915190.55 TEST REPORT Radio Spectrum Matters (RF) Identification of item tested Cync Direct Connect Strip Trademark GE Model and /or type reference CSTR16CBDM, CSTR32CBDM FCC/IC ID FCC ID: PUU-STR-CBDM; IC: 10798A-STRCBDM HVIN N/A Features 120Vac, 60Hz Applicant ́s name / address Savant Technologies LLC dba GE Lighting, a Savant company 1975 Noble Road, Cleveland, Ohio, United States, 44112 Test method requested, standard FCC CFR Title 47 Part15 Subpart C Section 15.247; KDB558074 D01v05r02; RSS-Gen Issue 5; RSS-247 Issue 3 Verdict Summary COMPLIANCE Tested by (name & signature) Johnny Bo Approved by (name & signature) Tim Yan Date of issue 2024-04-11 Report template No TRF_EMC 2017-06- FCC_Exposure DEKRA Testing and Certification (Shanghai) Ltd. Guangzhou Branch Block 5, No.3, Qiyun Road, Huangpu District, Guangzhou, Guangdong, China Tel +86 20 6661 2000 Fax +86 20 6661 2001 https://www.dekra.comv Report no.: 4915190.55 Page 2 / 10 INDEX page General conditions ................................................................................................................................. 3 Uncertainty............................................................................................................................................. 3 Environmental conditions ....................................................................................................................... 3 Possible test case verdicts ..................................................................................................................... 3 Definition of symbols used in this test report .......................................................................................... 4 Abbreviations ......................................................................................................................................... 4 Document History .................................................................................................................................. 4 Remarks and Comments ....................................................................................................................... 4 1 General Information ........................................................................................................................ 5 1.1 General Description of the Item(s) ......................................................................................... 5 1.2 Test data ............................................................................................................................... 7 1.3 The environment(s) in which the EUT is intended to be used ................................................ 7 2 Description of Test Setup ................................................................................................................ 8 2.1 Operating mode(s) used for tests .......................................................................................... 8 2.2 Port(s) of the EUT ................................................................................................................. 8 2.3 Support / Auxiliary equipment / unit / software for the EUT .................................................... 8 2.4 Test Configuration / Block diagram used for tests ................................................................. 8 3 RF Exposure Evaluation .................................................................................................................. 9 3.1 Limits .................................................................................................................................... 9 3.2 Test Procedure ................................................................................................................... 10 3.3 Test Result .......................................................................................................................... 10 DEKRA Testing and Certification (Shanghai) Ltd. Guangzhou Branch Block 5, No.3, Qiyun Road, Huangpu District, Guangzhou, Guangdong, China Tel +86 20 6661 2000 Fax +86 20 6661 2001 https://www.dekra.comv Report no.: 4915190.55 Page 3 / 10 GENERAL CONDITIONS 1. This report is only referred to the item that has undergone the test. 2. This report does not constitute or imply on its own an approval of the product by the Certification Bodies or Competent Authorities. 3. This document is only valid if complete; no partial reproduction can be made without previous written permission of DEKRA. 4. This test report cannot be used partially or in full for publicity and/or promotional purposes without previous written permission of DEKRA. 5. This report will not be used for social proof function in China market. UNCERTAINTY For all measurements where guidance for the calculation of the instrumentation uncertainty of a measurement is specified in EN 55016-4-2 (CISPR 16-4-2), EN/IEC 61000-4 series or a product standard, the measurement instrumentation uncertainty has been calculated and applied in accordance with these standards. Uncertainties have been calculated according to the DEKRA internal document. The reported expanded uncertainties are based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95%. ENVIRONMENTAL CONDITIONS The climatic conditions during the tests are within the limits specified by the manufacturer for the operation of the EUT and the test equipment. The climatic conditions during the tests were within the following limits: Ambient temperature 15 °C – 35 °C Relative Humidity air 30% - 60% Atmospheric pressure 86 kPa – 106 kPa If explicitly required in the basic standard or applied product / product family standard the climatic values are reco…

Text truncated - open the document above for the full version.

Test Report

DEKRA Testing and Certification (Shanghai) Ltd. Guangzhou Branch Block 5, No.3, Qiyun Road, Huangpu District, Guangzhou, Guangdong, China Tel +86 20 6661 2000 Fax +86 20 6661 2001 https://www.dekra.com Report no.: 4915190.50 Page 1 / 50 Test report No: 4915190.50 TEST REPORT Radio Spectrum Matters (RF) Identification of item tested Cync Direct Connect Strip Trademark GE Model and /or type reference CSTR16CBDM, CSTR32CBDM FCC ID PUU-STR-CBDM Features 120Vac, 60Hz Applicant ́s name / address Savant Technologies LLC dba GE Lighting, a Savant company 1975 Noble Road, Cleveland, Ohio, United States, 44112 Test method requested, standard FCC CFR Title 47 Part15 Subpart C Section 15.247; KDB558074 D01v05r02; Verdict Summary COMPLIANCE Tested by (name & signature) Johnny Bo Approved by (name & signature) Tim Yan Date of issue 2024-04-08 Report template No TRF_EMC 2017-06- FCC_Part15C_247 DEKRA Testing and Certification (Shanghai) Ltd. Guangzhou Branch Block 5, No.3, Qiyun Road, Huangpu District, Guangzhou, Guangdong, China Tel +86 20 6661 2000 Fax +86 20 6661 2001 https://www.dekra.com Report no.: 4915190.50 Page 2 / 50 INDEX page General conditions ...................................................................................................................................................... 4 Uncertainty .................................................................................................................................................................. 4 Environmental conditions............................................................................................................................................ 4 Possible test case verdicts ......................................................................................................................................... 4 Definition of symbols used in this test report .............................................................................................................. 5 Abbreviations .............................................................................................................................................................. 5 Document History ....................................................................................................................................................... 5 Remarks and Comments ............................................................................................................................................ 5 General Information .................................................................................................................................................... 6 1.1 General Description of the Item(s) .......................................................................................................... 6 1.2 Test data ................................................................................................................................................. 8 1.3 The environment(s) in which the EUT is intended to be used ................................................................ 8 1.4 Channel List ............................................................................................................................................ 8 2 Description of Test Setup ................................................................................................................................ 10 2.1 Operating mode(s) used for tests.......................................................................................................... 10 2.2 Support / Auxiliary equipment / unit / software for the EUT .................................................................. 10 2.3 Test Configuration / Block diagram used for tests ................................................................................ 10 2.4 Measurement procedure ....................................................................................................................... 10 3 Verdict summary section ................................................................................................................................. 11 3.1 Standards .............................................................................................................................................. 11 3.2 Deviation(s) from the Standard(s) / Test Specification(s) ..................................................................... 11 3.3 Overview of results ................................................................................................................................ 11 4 Transmitter Test Results ................................................................................................................................. 12 4.1 AC Power Line Conducted Emission .................................................................................................... 12 4.2 Emissions in non-restricted frequency bands ....................................................................................... 15 4.3 Emissions in restricted frequency bands .............................................................................................. 24 4.4 Band Edge ............................................................................................................................................. 31 4.5 Duty cycle .............................................................................................................................................. 34 4.6 DTS Bandwidth ..................................................................................................................................... 36 4.7 Fundamental emission output power .................................................................................................... 40 4.8 Power Density ....................................................................................................................................... 43 5 Identification of the Equipment Under T…

Text truncated - open the document above for the full version.

Test Report

DEKRA Testing and Certification (Shanghai) Ltd. Guangzhou Branch Block 5, No.3, Qiyun Road, Huangpu District, Guangzhou, Guangdong, China Tel +86 20 6661 2000 Fax +86 20 6661 2001 https://www.dekra.com Report no.: 4915190.51 Page 1 / 80 Test report No: 4915190.51 TEST REPORT Radio Spectrum Matters (RF) Identification of item tested Cync Direct Connect Strip Trademark GE Model and /or type reference CSTR16CBDM, CSTR32CBDM FCC ID PUU-STR-CBDM Features 120Vac, 60Hz Applicant ́s name / address Savant Technologies LLC dba GE Lighting, a Savant company 1975 Noble Road, Cleveland, Ohio, United States, 44112 Test method requested, standard FCC CFR Title 47 Part15 Subpart C Section 15.247; KDB558074 D01v05r02; Verdict Summary COMPLIANCE Tested by (name & signature) Johnny Bo Approved by (name & signature) Tim Yan Date of issue 2024-04-08 Report template No TRF_EMC 2017-06- FCC_Part15C_247 DEKRA Testing and Certification (Shanghai) Ltd. Guangzhou Branch Block 5, No.3, Qiyun Road, Huangpu District, Guangzhou, Guangdong, China Tel +86 20 6661 2000 Fax +86 20 6661 2001 https://www.dekra.com Report no.: 4915190.51 Page 2 / 80 INDEX page General conditions ...................................................................................................................................................... 4 Uncertainty .................................................................................................................................................................. 4 Environmental conditions............................................................................................................................................ 4 Possible test case verdicts ......................................................................................................................................... 4 Definition of symbols used in this test report .............................................................................................................. 5 Abbreviations .............................................................................................................................................................. 5 Document History ....................................................................................................................................................... 5 Remarks and Comments ............................................................................................................................................ 5 1 General Information ........................................................................................................................................... 6 1.1 General Description of the Item(s) .......................................................................................................... 6 1.2 Test data ................................................................................................................................................. 8 1.3 The environment(s) in which the EUT is intended to be used ................................................................ 8 1.4 Channel List ............................................................................................................................................ 8 2 Description of Test Setup ................................................................................................................................ 10 2.1 Operating mode(s) used for tests.......................................................................................................... 10 2.2 Support / Auxiliary equipment / unit / software for the EUT .................................................................. 10 2.3 Test Configuration / Block diagram used for tests ................................................................................ 10 2.4 Measurement procedure ....................................................................................................................... 10 3 Verdict summary section ................................................................................................................................. 11 3.1 Standards .............................................................................................................................................. 11 3.2 Deviation(s) from the Standard(s) / Test Specification(s) ..................................................................... 11 3.3 Overview of results ................................................................................................................................ 11 4 Transmitter Test Results ................................................................................................................................. 12 4.1 AC Power Line Conducted Emission .................................................................................................... 12 4.2 Emissions in non-restricted frequency bands ....................................................................................... 15 4.3 Emissions in restricted frequency bands .............................................................................................. 32 4.4 Band Edge ............................................................................................................................................. 47 4.5 Duty cycle .............................................................................................................................................. 54 4.6 DTS Bandwidth ..................................................................................................................................... 57 4.7 Fundamental emission output power .................................................................................................... 67 4.8 Power Density ....................................................................................................................................... 69 5 Identification of the Equipment Under Test ...…

Text truncated - open the document above for the full version.

Test Setup Photos

Radiated measurements <1G Radiated measurements >1G Conducted measurements Conducted RF measurements ---END---

Contact Information

Applicant

Paul Smith(Systems Engineer - Safety & Regulatory)
[email protected]2162662189Fax: 2162663003

Test Firm

DEKRA Testing and Certification (Shanghai) Ltd.Johnson Liu
[email protected]+86 20 66642980

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.41 GHz - 2.46 GHz44.66 mW
Confidentiality
Long Term
Grant Notes
Power listed is conducted.

Other Applications from Savant Technologies LLC, dba GE Lighting, a Savant Company

Dual sockets indoor plug - FCC ID PUU-CPLGID2BLW1 - Savant Technologies LLC, dba GE Lighting, a Savant Company
PUU-CPLGID2BLW1

Dual sockets indoor plug

Aug 05, 2026

Equipment Class

DTS - Digital Transmission System
CYNC Shoplight - FCC ID PUU-CFIXSHP46 - Savant Technologies LLC, dba GE Lighting, a Savant Company
PUU-CFIXSHP46

CYNC Shoplight

Jul 31, 2026

Equipment Class

DTS - Digital Transmission System
PUU-STR-CBDMI

Cync Direct Connect Strip

Jul 30, 2026

Equipment Class

DTS - Digital Transmission System
PUU-GEL-HAL

PROSEO Sage LF module

May 19, 2026

Equipment Class

DTS - Digital Transmission System
Fan Switch - FCC ID PUU-CSWFSBLK3T1 - Savant Technologies LLC, dba GE Lighting, a Savant Company
PUU-CSWFSBLK3T1

Fan Switch

Sep 04, 2025

Equipment Class

DTS - Digital Transmission System