Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Savant Technologies LLC, dba GE Lighting, a Savant company Covered Equipment Certification Attestation Letter June 6, 2024 Nemko North America, Inc. 303 River Road Ottawa K1V 1H2 Canada ATTN.: Reviewing Engineer FCC ID: PUU-STR-CDID Savant Technologies LLC, dba GE Lighting, a Savant Company (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Note: If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, the applicant should include an explanation on why the equipment is not “covered” equipment. Savant Technologies LLC, dba GE Lighting, a Savant Company (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Signed: Printed name: Paul Smith Title: Systems Engineer – Safety & Regulatory Company Name: Savant Technologies LLC, dba GE Lighting, a Savant Company Date: June 6, 2024
Savant Technologies LLC, dba GE Lighting, a Savant company * the applicant must designate a contact located in the United States for purposes of acting as the applicant’s agent for service of process, regardless of whether the applicant is a domestic or foreign entity. An applicant located in the United States may designate itself as the agent for service of process. U.S. Agent Designation for Service of Process - Certification Attestation Letter June 27, 2024 Nemko North America, Inc. 303 River Road Ottawa K1V 1H2 Canada ATTN.: Reviewing Engineer FCC ID: PUU-STR-CDID Per section 2.911(d)(7) of the FCC rules, Savant Technologies LLC, dba GE Lighting, a Savant company (“the applicant”) certifies that the equipment for which authorization is sought is designated to the following U.S. Designated agent* for service of process: Company Name: Savant Technologies LLC, dba GE Lighting, a Savant company Physical U.S. Company Address: 1975 Noble Road, Cleveland, Ohio 44112, United States Agent name: Paul Smith Agent Email Address: [email protected] FRN: 0022026876 The above contact person accepts the obligation for service of process. The applicant accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Applicant Signed: Designated Agent Signed: (Required, if different to Applicant): Signed: Printed name: Paul Smith Title: Systems Engineer – Safety & Regulatory Company Name: Savant Technologies LLC, dba GE Lighting, a Savant company Date: June 27, 2024
Savant Technologies LLC, dba GE Lighting, a Savant company 6/6/2024 Nemko North America, Inc. 303 River Road Ottawa, Ontario, Canada K1V 1H2 AUTHORITY TO ACT AS AGENT - FCC On our behalf, I appoint DEKRA Testing and Certification (Shanghai) Ltd. Guangzhou Branch, to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in FCC regulations will have affixed to it a label identical to that submitted for approval with this application. In signing this letter, Applicant certifies that neither the applicant nor any party to the application is not subject to a denial of Federal benefits, that include FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. § 862 because of a conviction for possession or distribution of a controlled substance. See 47 CFR 1.2002(b) for the definition of a "party" for these purposes. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, as specified by Nemko North America Inc., still resides still resides with us. Sincerely, Printed name: Paul Smith
Savant Technologies LLC, dba GE Lighting, a Savant company June 27, 2024 Nemko North America, Inc. 303 River Road Ottawa, Ontario, Canada K1V 1H2 REQUEST FOR CONFIDENTIALITY - FCC FCC ID: PUU-STR-CDID Pursuant to Sections 0.457(d) and 0.459 of the Commission’s Rules and FCC Guidance document 726920, we hereby request permanent confidential treatment of exhibits identified as such in the table below and request they are permanently withheld from public review based on the documents containing trade secrets and proprietary information not customarily released to the public. The public disclosure of this information might be harmful to the applicant and provide unjustified benefits to its competitors. We also request short-term confidentiality on certain exhibits until the intended date of marketing as outlined below. We request the exhibits be withheld from public view for a period of 180 days. We attest marketing of the product will only commence after the period of short-term confidentiality expires, or if marketing is to commence before the requested number of days listed above, the grantee will inform Nemko to release the Short-Term Confidentiality information withheld on the FCC equipment authorization website. Exhibit Type of Confidentiality Requested Block Diagrams ☒ Permanent ☐ Short Term External Photos ------------------ ☒ Short Term Internal Photos ☐ Permanent* ☒ Short Term Operation Description ☒ Permanent ☐ Short Term Parts List & Placement/BOM ☐ Permanent ☐ Short Term Tune-Up Procedure ☐ Permanent ☐ Short Term Schematic Diagrams ☒ Permanent ☐ Short Term Test Setup Photos ------------------ ☒ Short Term User’s Manual ☐ Permanent* ☒ Short Term The asterisked items (*) require further information to be provided in this justification letter before permanent confidentiality will be extended to these exhibits. Please refer to FCC KDB 726920 D01 found at: https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=41731 and review section II, 3) regarding specific information that must accompany these requests. Note: any documents held under the Short-Term confidentiality will automatically become public after the requested time if an appropriate extension request has not been received. Any exhibits (i.e., schematic diagrams) that may have already been requested to have “Permanent” confidentiality as shown above need not be repeated under Short-Term confidentiality request. Sincerely, Signed: Printed name: Paul Smith Title: Systems Engineer – Safety & Regulatory Company Name: Savant Technologies LLC, dba GE Lighting, a Savant company
Savant Technologies LLC, dba GE Lighting, a Savant company Family Certification Attestation Letter 6/27/2024 Nemko Canada Inc 303 River Road Ottawa K1V 1H2 Canada ATTN.: Reviewing Engineer FCC : PUU-STR-CDID IC: 10798A-STRCDID HVINs/Models: CSTR16CDID/ENS; CSTR32CDID/ENS We hereby request Family Certification for the above mentioned HVINs/Models based on them being electrically identical apart from model name/number. Above models are identical in schematic and structure, The circuit, RF Chip, PCB, component and the specifications of wireless functions are the same. which are not affect the RF characteristics. Only the Length of LED strip is different for all the models, therefore the test performed on the model _CSTR32CDID/ENS__. Signed: Printed name: Paul Smith Title: Systems Engineer – Safety & Regulatory Date: 6/27/2024
25mm24mm48mm Model No.:CSTR16CDID/ENS Input:24V 1A IC:10798A-STRCDID FCC ID:PUU-STR-CDID Made in China YYDDD ZYCN Indoor premium 16ft 国内版 25mm24mm48mm Model No.:CSTR16CDID/ENS Input:24V 1A IC:10798A-STRCDID FCC ID:PUU-STR-CDID Made in Vietnam YYDDD ZYVN 越南版 25mm24mm48mm Model No.:CSTR32CDID/ENS Input:24V 1A IC:10798A-STRCDID FCC ID:PUU-STR-CDID Made in China YYDDD ZYCN Indoor premium 32ft 国内版 25mm24mm48mm Model No.:CSTR32CDID/ENS Input:24V 1A IC:10798A-STRCDID FCC ID:PUU-STR-CDID Made in Vietnam YYDDD ZYVN 越南版 电源镭射图 22mm 22mm 6mm 8mm8mm 22mm GE Lighting,a Savant Company
JXC8720-18 ANTENNASPECIFICATIONS ItemSpecifications Antenna FrequencyRange2400~2483.5MHz PolarizationLinear PeakGain0.5dBi V.S.W.R < 2.0 Impedance50Ω ReturnLoss-10dB ConnectorMicrostriplineconnection Efficiency 25% Type Onboard:ANT0 Size 12.5x6.5mm Manufacturer ShenzhenJingxunTechologyLimited Co.,Ltd Manufactureraddress 3/F,A5BuildingZhiyuanCommunityNo.1001, XueyuanRoad,NanshanDistrict,Shenzhen City,China EnvironmentalOperatingTemperature-40°C~+105°C ANTENNAPATTERN AntennaPicture :
DEKRA Testing and Certification (Shanghai) Ltd. Guangzhou Branch Block 5, No.3, Qiyun Road, Huangpu District, Guangzhou, Guangdong, China Tel +86 20 6661 2000 Fax +86 20 6661 2001 https://www.dekra.com Report no.: RF Exposure Page 1 / 12 Test report No: RF Exposure TEST REPORT Radio Spectrum Matters (RF) Identification of item tested Cync dynamic effect indoor strip Trademark GE Model and /or type reference CSTR16CDID/ENS, CSTR32CDID/ENS FCC ID PUU-STR-CDID Features Adaptor: CLASS 2 POWER UNIT MODEL NO: XY24SR-240100VQ-UW INPUT: 100-240Vac, 50/60Hz, 0.6A MAX OUTPUT: 24Vdc, 1.0A Applicant ́s name / address Savant Technologies LLC, dba GE Lighting, a Savant Company 1975 Noble Road, Cleveland, OH, 44112, US. Test method requested, standard KDB 447498 D01V06 FCC Part 1.1310 Verdict Summary COMPLIANCE Tested by (name & signature) Jazz Liang Approved by (name & signature) Tim Yan Date of issue 2024-06-19 Report template No TRF_EMC 2017-06- FCC_Exposure DEKRA Testing and Certification (Shanghai) Ltd. Guangzhou Branch Block 5, No.3, Qiyun Road, Huangpu District, Guangzhou, Guangdong, China Tel +86 20 6661 2000 Fax +86 20 6661 2001 https://www.dekra.com Report no.: RF Exposure Page 2 / 12 INDEX page General conditions ............................................................................................................................................... 3 Uncertainty .......................................................................................................................................................... 3 Environmental conditions ..................................................................................................................................... 3 Possible test case verdicts ................................................................................................................................... 3 Definition of symbols used in this test report ......................................................................................................... 4 Abbreviations ....................................................................................................................................................... 4 Document History ................................................................................................................................................ 4 Remarks and Comments ..................................................................................................................................... 4 1 General Information .................................................................................................................................... 5 1.1 General Description of the Item(s) ..................................................................................................... 5 1.2 Test data ........................................................................................................................................... 8 1.3 The environment(s) in which the EUT is intended to be used ............................................................. 8 2 Description of Test Setup ............................................................................................................................ 9 2.1 Operating mode(s) used for tests ...................................................................................................... 9 2.2 Support / Auxiliary equipment / unit / software for the EUT ................................................................. 9 2.3 Test Configuration / Block diagram used for tests .............................................................................. 9 2.4 Measurement procedure ................................................................................................................. 10 3 RF Exposure Evaluation ............................................................................................................................ 11 3.1 Limits .............................................................................................................................................. 11 3.2 Test Procedure ............................................................................................................................... 12 3.3 Test Result ...................................................................................................................................... 12 DEKRA Testing and Certification (Shanghai) Ltd. Guangzhou Branch Block 5, No.3, Qiyun Road, Huangpu District, Guangzhou, Guangdong, China Tel +86 20 6661 2000 Fax +86 20 6661 2001 https://www.dekra.com Report no.: RF Exposure Page 3 / 12 GENERAL CONDITIONS 1. This report is only referred to the item that has undergone the test. 2. This report does not constitute or imply on its own an approval of the product by the Certification Bodies or Competent Authorities. 3. This document is only valid if complete; no partial reproduction can be made without previous written permission of DEKRA. 4. This test report cannot be used partially or in full for publicity and/or promotional purposes without previous written permission of DEKRA. 5. This report will not be used for social proof function in China market. UNCERTAINTY For all measurements where guidance for the calculation of the instrumentation uncertainty of a measurement is specified in EN 55016-4-2 (CISPR 16-4-2), EN/IEC 61000-4 series or a product standard, the measurement instrumentation uncertainty has been calculated and applied in accordance with these standards. Uncertainties have been calculated according to the DEKRA internal document. The reported expanded uncertainties are based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95%. ENVIRONMENTAL CONDITIONS The climatic conditions during the tests are within the limits specified by the manufacturer for the operation of the EUT and the test equipment. The climatic conditions during the tes…
Text truncated - open the document above for the full version.
DEKRA Testing and Certification (Shanghai) Ltd. Guangzhou Branch Block 5, No.3, Qiyun Road, Huangpu District, Guangzhou, Guangdong, China Tel +86 20 6661 2000 Fax +86 20 6661 2001 https://www.dekra.com Report no.: 4918539.50 Page 1 / 51 Test report No: 4918539.50 TEST REPORT Radio Spectrum Matters (RF) Identification of item tested Cync dynamic effect indoor strip Trademark GE Model and /or type reference CSTR16CDID/ENS, CSTR32CDID/ENS FCC ID PUU-STR-CDID Features Adaptor: CLASS 2 POWER UNIT MODEL NO: XY24SR-240100VQ-UW INPUT: 100-240Vac, 50/60Hz, 0.6A MAX OUTPUT: 24Vdc, 1.0A Applicant ́s name / address Savant Technologies LLC, dba GE Lighting, a Savant Company 1975 Noble Road, Cleveland, OH, 44112, US. Test method requested, standard FCC CFR Title 47 Part15 Subpart C Section 15.247; KDB558074 D01v05r02; Verdict Summary COMPLIANCE Tested by (name & signature) Jazz Liang Approved by (name & signature) Tim Yan Date of issue 2024-06-19 Report template No TRF_EMC 2017-06- FCC_Part15C_247 DEKRA Testing and Certification (Shanghai) Ltd. Guangzhou Branch Block 5, No.3, Qiyun Road, Huangpu District, Guangzhou, Guangdong, China Tel +86 20 6661 2000 Fax +86 20 6661 2001 https://www.dekra.com Report no.: 4918539.50 Page 2 / 51 INDEX page General conditions ............................................................................................................................................... 3 Uncertainty .......................................................................................................................................................... 3 Environmental conditions ..................................................................................................................................... 3 Possible test case verdicts ................................................................................................................................... 3 Definition of symbols used in this test report ......................................................................................................... 4 Abbreviations ....................................................................................................................................................... 4 Document History ................................................................................................................................................ 4 Remarks and Comments ..................................................................................................................................... 4 1 General Information .................................................................................................................................... 5 1.1 General Description of the Item(s) ..................................................................................................... 5 1.2 Test data ........................................................................................................................................... 8 1.3 The environment(s) in which the EUT is intended to be used ............................................................. 8 2 Description of Test Setup ............................................................................................................................ 9 2.1 Operating mode(s) used for tests ...................................................................................................... 9 2.2 Support / Auxiliary equipment / unit / software for the EUT ................................................................. 9 2.3 Test Configuration / Block diagram used for tests .............................................................................. 9 2.4 Measurement procedure ................................................................................................................... 9 3 Verdict summary section ........................................................................................................................... 10 3.1 Standards ....................................................................................................................................... 10 3.2 Deviation(s) from the Standard(s) / Test Specification(s).................................................................. 10 3.3 Overview of results .......................................................................................................................... 10 4 Transmitter Test Results ........................................................................................................................... 11 4.1 AC Power Line Conducted Emission ............................................................................................... 11 4.2 Emissions in non-restricted frequency bands ................................................................................... 14 4.3 Emissions in restricted frequency bands .......................................................................................... 25 4.4 Band Edge ...................................................................................................................................... 32 4.5 Duty cycle ....................................................................................................................................... 35 4.6 DTS Bandwidth ............................................................................................................................... 37 4.7 Fundamental emission output power ............................................................................................... 42 4.8 Power Density ................................................................................................................................. 45 5 Identification of the Equipment Under Test ................................................................................................ 47 Annex 1 – Measurement Uncertainty..........................................................................................…
Text truncated - open the document above for the full version.
DEKRA Testing and Certification (Shanghai) Ltd. Guangzhou Branch Block 5, No.3, Qiyun Road, Huangpu District, Guangzhou, Guangdong, China Tel +86 20 6661 2000 Fax +86 20 6661 2001 https://www.dekra.com Report no.: 4918539.51 Page 1 / 88 Test report No: 4918539.51 TEST REPORT Radio Spectrum Matters (RF) Identification of item tested Cync dynamic effect indoor strip Trademark GE Model and /or type reference CSTR16CDID/ENS, CSTR32CDID/ENS FCC ID PUU-STR-CDID Features Adaptor: CLASS 2 POWER UNIT MODEL NO: XY24SR-240100VQ-UW INPUT: 100-240Vac, 50/60Hz, 0.6A MAX OUTPUT: 24Vdc, 1.0A Applicant ́s name / address Savant Technologies LLC, dba GE Lighting, a Savant Company 1975 Noble Road, Cleveland, OH, 44112, US. Test method requested, standard FCC CFR Title 47 Part15 Subpart C Section 15.247; KDB558074 D01v05r02; Verdict Summary COMPLIANCE Tested by (name & signature) Jazz Liang Approved by (name & signature) Tim Yan Date of issue 2024-06-19 Report template No TRF_EMC 2017-06- FCC_Part15C_247 DEKRA Testing and Certification (Shanghai) Ltd. Guangzhou Branch Block 5, No.3, Qiyun Road, Huangpu District, Guangzhou, Guangdong, China Tel +86 20 6661 2000 Fax +86 20 6661 2001 https://www.dekra.com Report no.: 4918539.51 Page 2 / 88 INDEX page General conditions ............................................................................................................................................... 3 Uncertainty .......................................................................................................................................................... 3 Environmental conditions ..................................................................................................................................... 3 Possible test case verdicts ................................................................................................................................... 3 Definition of symbols used in this test report ......................................................................................................... 4 Abbreviations ....................................................................................................................................................... 4 Document History ................................................................................................................................................ 4 Remarks and Comments ..................................................................................................................................... 4 1 General Information .................................................................................................................................... 5 1.1 General Description of the Item(s) ..................................................................................................... 5 1.2 Test data ........................................................................................................................................... 8 1.3 The environment(s) in which the EUT is intended to be used ............................................................. 8 2 Description of Test Setup ............................................................................................................................ 9 2.1 Operating mode(s) used for tests ...................................................................................................... 9 2.2 Support / Auxiliary equipment / unit / software for the EUT ................................................................. 9 2.3 Test Configuration / Block diagram used for tests .............................................................................. 9 2.4 Measurement procedure ................................................................................................................... 9 3 Verdict summary section ........................................................................................................................... 10 3.1 Standards ....................................................................................................................................... 10 3.2 Deviation(s) from the Standard(s) / Test Specification(s).................................................................. 10 3.3 Overview of results .......................................................................................................................... 10 4 Transmitter Test Results ........................................................................................................................... 11 4.1 AC Power Line Conducted Emission ............................................................................................... 11 4.2 Emissions in non-restricted frequency bands ................................................................................... 14 4.3 Emissions in restricted frequency bands .......................................................................................... 37 4.4 Band Edge ...................................................................................................................................... 52 4.5 Duty cycle ....................................................................................................................................... 59 4.6 DTS Bandwidth ............................................................................................................................... 62 4.7 Fundamental emission output power ............................................................................................... 75 4.8 Power Density ................................................................................................................................. 80 5 Identification of the Equipment Under Test ................................................................................................ 84 Annex 1 – Measurement Uncertainty..........................................................................................…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15C | 2.41 GHz - 2.46 GHz | 73.50 mW |

Dual sockets indoor plug
Equipment Class
DTS - Digital Transmission System
CYNC Shoplight
Equipment Class
DTS - Digital Transmission SystemCync Direct Connect Strip
Equipment Class
DTS - Digital Transmission SystemPROSEO Sage LF module
Equipment Class
DTS - Digital Transmission System
Fan Switch
Equipment Class
DTS - Digital Transmission System