Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
TM ADSL 201ER User’s Manual CONTENTS Important Safeguards ----------------------------------------------------------------------- 4 FCC Information ------------------------------------------------------------------------------ Preparing to Install --------------------------------------------------------------------------- 1. Introduction ----------------------------------------------------------------------------------------------------------- 2. System Requirements --------------------------------------------------------------------------------------------- 3. Front Panel ----------------------------------------------------------------------------------------------------------- 4 Rear Panel ------------------------------------------------------------------------------------------------------------ 5. LEDs ------------------------------------------------------------------------------------------------------------------- Installation -------------------------------------------------------------------------------------- 1. Parts Included -------------------------------------------------------------------------------------------------------- 2. Connecting the Hardware ----------------------------------------------------------------------------------------- 3. Verifying Connections --------------------------------------------------------------------------------------------- 4. Question and Answer (Q & A) ----------------------------------------------------------------------------------- Configuration Settings ---------------------------------------------------------------------- 1. Configuring You PC to Access the 201ER -------------------------------------------------------------------- 2. Accessing the 201ER ---------------------------------------------------------------------------------------------- 3. Quick Setup ---------------------------------------------------------------------------------------------------------- 4 System Configuration ---------------------------------------------------------------------------------------------- 5. System Status ------------------------------------------------------------------------------------------------------- 6. System Administration --------------------------------------------------------------------------------------------- Appendix --------------------------------------------------------------------------------------- Warranty Information ------------------------------------------------------------------------ INDUSTRY CANADA (IC)NOTICE ------------------------------------------------------ Technical Support and Modem Returns ------------------------------------------------ 6 8 8 8 9 9 10 10 10 11 12 12 14 14 25 26 30 44 54 62 64 65 66 Important Safeguards Please read and understand all instructions. Follow all warnings and instructions marked on the product. Environment The VisionNet 201ER is intended for in-house stationary use (desktop or wall-mounted). The maximum ambient temperature may not exceed 40C (104F) external to the housing. The VisionNet 201ER must not be mounted in a location exposed to direct heat or excessive solar or radiation. The VisionNet 201ER should not be exposed to heat trap conditions and must not be subjected to water or condensation. The VisionNet 201ER must be installed in a Pollution Degree 2 environment. Cleaning Unplug the 201ER from the wall outlet before cleaning. Do not use liquid or aerosol cleaners. Use a damp cloth for cleaning. Water and Moisture Do not use the 201ER near water (near a bathtub, wash bowl, kitchen sink, laundry tub, in a wet basement or near a swimming pool). Power Sources The 201ER should be operated only from the type of power source indicated on the marking labels. If you are not sure of type of power supply to your home, consult technical support or your local power company. The main socket outlet should be near the equipment and easily accessible. The router equipment is not intended to be connected to an IT-type power system. Power Cord Protection Do not allow anything to rest on the power cord. Do not locate this product where the cord will be subject to persons walking on it. Overloading Do not overload wall (mains) outlets and extension cords as this can result in fire or electric shock. Servicing To reduce the risk of electric shock, do not disassemble this product. None of its parts are user replaceable; therefore, no reason exists to access the interior. Opening or removing the cover may expose you to dangerous voltages or other risks. In addition, incorrect reassembly can cause electric shock when the appliance is subsequently used. If service or repair work is required, take it to qualified service personnel. Damage Requiring Service Unplug the product from the wall outlet and refer servicing to qualified service personnel under the following conditions: If liquid has been spilled into the product. If the product has been exposed to rain or water. If the product does not operate normally when following the operating instructions. If the product has been dropped and damaged. If the product exhibits a distinct change in performance. Modem / Telephone Use Avoid using a modem/telephone during an electrical storm. There may be a remote risk of electric shock from lightning. Do not use the telephone to report a gas leak in the vicinity of the leak. If telephone service is required on the same line and for optimum ADSL performance, distributed filters must be installed. Depending on your ADSL configuration and type of filters, installation may be required by qualified service personnel. Consult your telephone company or ADSL service provider for instructions. FCC Information Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment ge…
Text truncated - open the document above for the full version.
25.000 1.8432
E E M M C C T T E E S S T T R R E E P P O O R R T T Report reference No: KST-FCC0404 KOSTEC Co.,Ltd. 180-254,Annyung-Ri, Taean-Yup, Hwasung-shi, Kyunggi-do, Korea Tel : +82-31-222-4251 Fax: +82-31-222-4252 http://www.kosteclab.com Page : 18 of 18 EUT Front Rear E E M M C C T T E E S S T T R R E E P P O O R R T T Report reference No: KST-FCC0404 KOSTEC Co.,Ltd. 180-254,Annyung-Ri, Taean-Yup, Hwasung-shi, Kyunggi-do, Korea Tel : +82-31-222-4251 Fax: +82-31-222-4252 http://www.kosteclab.com Page : 21 of 21 I/O Port veiw I/O Port view ( without console port ) E E M M C C T T E E S S T T R R E E P P O O R R T T Report reference No: KST-FCC0404 KOSTEC Co.,Ltd. 180-254,Annyung-Ri, Taean-Yup, Hwasung-shi, Kyunggi-do, Korea Tel : +82-31-222-4251 Fax: +82-31-222-4252 http://www.kosteclab.com Page : 22 of 22 I/O Port view ( without usb port ) I/O Port view ( without console & usb port )
E E M M C C T T E E S S T T R R E E P P O O R R T T Report reference No: KST-FCC0404 KOSTEC Co.,Ltd. 180-254,Annyung-Ri, Taean-Yup, Hwasung-shi, Kyunggi-do, Korea Tel : +82-31-222-4251 Fax: +82-31-222-4252 http://www.kosteclab.com Page : 23 of 23 Appendix – Sample Label
TM DC5V 1.2A Made in Korea FCC ID : PWVW201ER Tested To Comply With FCC standards For Home or Office Use Bar-cord and S/N DQ Technology, Inc. ADSL Modem This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions : (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. M/N : W201 & W201ES & W201ER W707 & W707ER & W707EUR Manufacture: Wellink Corporati on / NETUS Technologeis Co., Ltd
E E M M C C T T E E S S T T R R E E P P O O R R T T Report reference No: KST-FCC0404 KOSTEC Co.,Ltd. 180-254,Annyung-Ri, Taean-Yup, Hwasung-shi, Kyunggi-do, Korea Tel : +82-31-222-4251 Fax: +82-31-222-4252 http://www.kosteclab.com Page : 20 of 20 Mainboard(ADSL Modem) (Front) Mainboard(ADSL Modem) (Rear) E E M M C C T T E E S S T T R R E E P P O O R R T T Report reference No: KST-FCC0404 KOSTEC Co.,Ltd. 180-254,Annyung-Ri, Taean-Yup, Hwasung-shi, Kyunggi-do, Korea Tel : +82-31-222-4251 Fax: +82-31-222-4252 http://www.kosteclab.com Page : 19 of 21 Inside AC/DC adapter
Q'ty Maker NOTE Component Name Q'ty Maker NOTE Component Name Q'ty Maker Component Name NOTE Q'ty Maker Q'ty Maker NOTE Component Name Component Name NOTE Q'ty Maker Component Name NOTE Q'ty Maker NOTE Component Name Q'ty Maker NOTE Component Name Q'ty Maker NOTE Component Name Q'ty Maker NOTE Component Name
E E M M I I T T E E S S T T R R E E P P O O R R T T FCC EVALUATION REPORT FOR CERTIFICATION Korea Standard Technology Test report No.: KST-FCC0404 Manufacturer’s Name : Wellink Corporation Manufacturer’s Address201,A-Dong, PundangTechnopark, 150, YatapDong, Pundang-Gu, Sungnam-Si, Kyungki-Do, Korea EUT’s : FCC ID : PWVW201ER Product Name : ADSL Modem Model Number(s) : W201 & W201ES & W201ER & W707 & W707ER & W707EUR Product Options : Request for enter a multi list of model name by manufacturer. & Consumer have a option items that Without USB port or Console port or both ports. Category : FCC Part 15 sub. part B Class B Digital Device Supplementary Information The device bearing the brand name and FCC ID specified above has been shown to comply with the applicable technical standards as indicated in the measurement report and was tested in accordance with measurement procedures specified in ANSI C63.4-1992 . I attest to the accuracy of data and all measurements reported herein were performed by or were made under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. Issue Date : February 14, 2004 Te s t e d b y : Approved by: Kim, Ha-Hyoung Lee, Woen-woo E E M M C C T T E E S S T T R R E E P P O O R R T T Report reference No: KST-FCC0404 KOSTEC Co.,Ltd. 180-254,Annyung-Ri, Taean-Yup, Hwasung-shi, Kyunggi-do, Korea Tel : +82-31-222-4251 Fax: +82-31-222-4252 http://www.kosteclab.com Page : 2 of 2 Contents 1. Description of Device 2. Test Facility 3. MAP 4. Facility Environment 5. Description of E.U.T. 6. Summary of test results. 7. Test results. 8. Photographs. Appendix. Sample Label E E M M C C T T E E S S T T R R E E P P O O R R T T Report reference No: KST-FCC0404 KOSTEC Co.,Ltd. 180-254,Annyung-Ri, Taean-Yup, Hwasung-shi, Kyunggi-do, Korea Tel : +82-31-222-4251 Fax: +82-31-222-4252 http://www.kosteclab.com Page : 3 of 3 1. Description of Device 1) Kind of equipment: ADSL Modem 2) FCC ID: PWVW201ER 3) Model Name: W201 & W201ES & W201ER & W707 & W707ER & W707EUR 4) Serial No.: None 5) Type of Sample Tested: Pre-production / addition & alteration of parts(component) 6) High Frequency Used: 1.8432 MHz 25.000 MHz 35.328 MHz 7) Adapter Model name: DSA-006-05A Manufacturer: DVE. Serial no: 3403 8) Power Rating: 1phase AC90-132V, A, 47/63Hz Output: DC 5V, 1.2A 9) Tested Power supply: 1phase AC110V, 60Hz 10) Date of Manufacture: February 2004 11) Manufacture: Wellink Corporation 12) Description of Operating: Use to direct spread spectrum transmitters & hyper-terminal for data transmission 13) Dates of Test: February 10 ~ 13 , 2004 14) Place of Tests: Korea Standard Technology EMC site 15) Test Report No: KST-FCC0404 E E M M C C T T E E S S T T R R E E P P O O R R T T Report reference No: KST-FCC0404 KOSTEC Co.,Ltd. 180-254,Annyung-Ri, Taean-Yup, Hwasung-shi, Kyunggi-do, Korea Tel : +82-31-222-4251 Fax: +82-31-222-4252 http://www.kosteclab.com Page : 4 of 4 2. Test Facility The open field test site and conducted measurement facility are used for these testing, where are located following address and drawing. This site was fully described in a report dated November 14, 2002, that was submitted to the FCC. Korea Standard Technology ( KOSTEC Co., Ltd) Head office: 302 City Bild, 1600-3 Kwanyang-dong, Dongan-gu, Anyang-shi, Kyunggi-do, Korea Telephone No : 82-31-388-2051 Facsimile No: 82-31-388-2052 Test Lab :180-254, Annyung-Ri, Taean-Yup, Hwasung-shi, Kyunggi-do, Korea Telephone No : 82-31-222-4251 Facsimile No: 82-31-222-4252 MIC(Ministry of Information and Communication) No: KR0042 FCC Filing No. : 525762 VCCI Membership Number : 2005 VCCI Registration Number : R-1657 / C-1763 E E M M C C T T E E S S T T R R E E P P O O R R T T Report reference No: KST-FCC0404 KOSTEC Co.,Ltd. 180-254,Annyung-Ri, Taean-Yup, Hwasung-shi, Kyunggi-do, Korea Tel : +82-31-222-4251 Fax: +82-31-222-4252 http://www.kosteclab.com Page : 5 of 5 3. MAP Korea Hwasung-shi (open area test site) KOSTEC Co., Ltd E E M M C C T T E E S S T T R R E E P P O O R R T T Report reference No: KST-FCC0404 KOSTEC Co.,Ltd. 180-254,Annyung-Ri, Taean-Yup, Hwasung-shi, Kyunggi-do, Korea Tel : +82-31-222-4251 Fax: +82-31-222-4252 http://www.kosteclab.com Page : 6 of 6 4. . Facility Environment Operation Environment Ambient Temperature ( C ) Humidity ( % ) Pressure ( hPa ) 10m Open Area site 12.9 45 1020 Shielded room: 19.1 42 1023 Test site These testing were performed following locations ; Shielded room : Conducted Emission, 10m Open Area Site: Radiated Emission Measurement Uncertainty All measurements involve certain levels of uncertainties, especially in field of EMC. The factors contributing to uncertainties are test receiver, Cable loss, antenna factor calibration, Antenna directivity, antenna factor variation with height, antenna phase center variation, antenna frequency interpolation, measurement distance variation, ite imperfection, mismatch, and system repeatability. Based on NIS 80,81, The measurement uncertainty level with a 95% confidence level were applied. sample calculation Conducted emission The field strength is calculated by adding the LISN factor, cable loss from the measured reading. The sample calculation is as follows: FS = MR + LF + CL MR = Meter Reading LF = LISN Factor CL = Cable Loss If MR is 30dB, LISN Factor 1dB, CL 1dB The result (MR) is 30 + 1 + 1 = 32dBuV E E M M C C T T E E S S T T R R E E P P O O R R T T Report reference No: KST-FCC0404 KOSTEC Co.,Ltd. 180-254,Annyung-Ri, Taean-Yup, Hwasung-shi, Kyunggi-do, Korea Tel : +82-31-222-4251 Fax: +82-31-222-4252 http://www.kosteclab.com Page : 7 of 7 5. Description of E.U.T. Product Description Manufactured By: Wellink Corporation Address: 201 A-Dong, Pundang Technopark 150, Yatop-Dong, Pundang-Gu, Seongnam-Shi, Kyunggi-Do, Korea Model: W201 & W201ES & W201ER & W707 & W707ER & W707EUR Serial Number: None Used Peripherals D…
Text truncated - open the document above for the full version.
E E M M C C T T E E S S T T R R E E P P O O R R T T Report reference No: KST-FCC0404 KOSTEC Co.,Ltd. 180-254,Annyung-Ri, Taean-Yup, Hwasung-shi, Kyunggi-do, Korea Tel : +82-31-222-4251 Fax: +82-31-222-4252 http://www.kosteclab.com Page : 8 of 8 Operating : After Connected from Hub to LAN port of E.U.T. by UTP cable(RJ-45 to RJ-45) And connected from E.U.T to PC by USB & UTP cable(RJ-45). And connected from TEL line of wall to E.U.T. by UTP cable(RJ-11). And connected from E.U.T to Telephone by UTP cable(RJ- 11). And then use to direct spread spectrum transmitters & hyper-terminal program for data transmission. 4.4 Test Configuration of E.U.T. (Example) 6. Summary of Test Results Modification to the E.U.T. - Consumer have a option items that without USB port or Console port or both ports. - We have each test of four times. The first test with USB & Console port and second test without console port and third test without usb port. And the last test without usb & console port Result : - PASS E E M M C C T T E E S S T T R R E E P P O O R R T T Report reference No: KST-FCC0404 KOSTEC Co.,Ltd. 180-254,Annyung-Ri, Taean-Yup, Hwasung-shi, Kyunggi-do, Korea Tel : +82-31-222-4251 Fax: +82-31-222-4252 http://www.kosteclab.com Page : 16 of 16 9. PHOTOGRAPHS Conducted emission ( Front ) Conducted emission ( Rear ) E E M M C C T T E E S S T T R R E E P P O O R R T T Report reference No: KST-FCC0404 KOSTEC Co.,Ltd. 180-254,Annyung-Ri, Taean-Yup, Hwasung-shi, Kyunggi-do, Korea Tel : +82-31-222-4251 Fax: +82-31-222-4252 http://www.kosteclab.com Page : 17 of 17 Radiated Emission ( Front ) Radiated Emission ( Rear )
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | - | - |

adsl modem
Equipment Class
JBP - Part 15 Class B Computing Device Peripheral
ADSL Modem
Equipment Class
JBP - Part 15 Class B Computing Device Peripheral
Dual-Port ADSL Bridge Router
Equipment Class
JBP - Part 15 Class B Computing Device Peripheral
ADSL Modem
Equipment Class
JBP - Part 15 Class B Computing Device Peripheral
ADSL Modem
Equipment Class
JBP - Part 15 Class B Computing Device Peripheral