FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. AeroScout/
  3. Q3HBS2040-1

Q3HBS2040-1EXCITER

AeroScout
EXCITER - FCC ID Q3HBS2040-1 - AeroScout
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Feb 23, 2006
Application Purpose
Original Equipment
Date of Application
Feb 23, 2006
Equipment Note
EXCITER
Frequency Range
0.12500000 - 0.12500000
Company
AeroScout
Country
Israel

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗
↗
↗

Internal Photos

↗

Operational Description

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

AeroScout Exciter EX3100 User Manuel EX3100-UM-160106-01 901 Mariner's Island Blvd. Suite 725 San Mateo, CA 94404 Tel: 650-571-0800 Fax: 650-571-6660 www.aeroscout.com Disclaimer The information and know-how included in this document are the exclusive property of AeroScout Inc. and are intended for the use of the addressee or the user alone. The addressees shall not forward to another their right of using the information, know-how or document forwarded herewith, in whole or in part in all matters relating or stemming from or involved therein, whether for consideration or without consideration, and shall not permit any third party to utilize the information, know-how or the documents forwarded herewith or copies or duplicates thereof, unless at the company’s consent in advance and in writing. Any distribution, advertisement, copying or duplication in any form whatsoever is absolutely prohibited. The Company reserves the right to sue the addressee, user and/or any one on their behalves, as well as third parties, in respect to breaching its rights pertaining to the intellectual rights in particular and its rights of whatever kind or type in the information, know-how or the documents forwarded by them herewith in general, whether by act or by omission. This document is confidential and proprietary to AeroScout Inc. and is not to be distributed to any persons other than licensed AeroScout Visibility System users or other persons appointed in writing by AeroScout Inc. Trademark Acknowledgements AeroScout™ is a registered trademark of AeroScout Inc. Other brand products and service names are trademarks or registered trademarks of their respective holders. Copyright 2004-2006 AeroScout Inc. All rights reserved. Table of Contents | 3 Table of Contents Introduction........................................................................................................5 Application and Industry Examples ...................................................................6 Features ............................................................................................................6 EX3100 Exciter Hardware .................................................................................7 LED Indications .......................................................................................................... 7 Connectors Panel....................................................................................................... 8 Power Supply Options................................................................................................ 9 Chaining Exciters.............................................................................................10 Mounting the Exciter........................................................................................10 Exciter Specifications ......................................................................................11 Introduction | 5 Introduction The AeroScout EX3100 Exciter is a component of the AeroScout suite of enterprise visibility solutions that enables location-based applications. The EX3100 Exciter extends the AeroScout suite to provide robust and sophisticated RFID detection capabilities, using the same AeroScout tags that can also be accurately located in real time by the AeroScout system. The EX3100 Exciter triggers AeroScout’s T2 tags in range, and those transmit a message to AeroScout Location Receivers or compatible Access Points. This provides instant acknowledgment that a tagged asset was present in a well- defined area. The detection and programming capabilities of the Exciter, combined with the location features of the AeroScout Visibility System, make the AeroScout suite the most sophisticated enterprise visibility solution for a wide variety of industries. The EX3100 Exciter can be utilized in one of the following ways: 1. Standalone: The EX3100 Exciter can trigger Tags located within a spherical area around it. 2. Chained: Several EX3100 Exciters can be used to cover a larger area and to operate as a single entity. 6 | Application and Industry Examples Application and Industry Examples High value asset tracking Health care facilities and general enterprises can tag valuable assets that are intended to stay within a certain area. The AeroScout system can track the location of those assets, and if they leave through an exit or enter a restricted area, the Exciter EX3100 triggers a tag message. Process control Manufacturing and supply chain facilities can track the location and presence of equipment and in-process inventory as it moves through the production process. This gives an enterprise a real-time view of which (and how many) assets have passed each step in the process, enabling better supply chain management. Inventory management Logistics and manufacturing enterprises can automatically update inventory records as inventory enters and leaves the warehouse, ensuring real-time knowledge of levels without manual checks or physical scanning. Reduced searching time Exciters can identify an individual asset among many similar assets, such as WIP items on a shelf in manufacturing, or multiple beds in a hospital room. The person initiating the search will not only know the location of the asset, but can also make the Tag physically identify itself through a blinking light. Security applications Government agencies and enterprises can tag secure assets and people that are restricted to certain areas or require historical location tracking. If those assets leave through an exit or enter a restricted area, EX3100 Exciter triggers a tag message. Features RFID detection of AeroScout T2 Tags Triggering the tags to transmit as they pass through a defined area, EX3100 Exciters reach up to a 3m (10 ft) range. Exciters can also be chained one to another, thus increasing the RFID detection range for accommodating even very large areas. Configurability The EX3100 Exciter Manager is a Windows application designed to configure the …

Text truncated - open the document above for the full version.

Cover Letter(s)

10 Oppenheimer St. Park Tamar, Rehovot, Israel, 76701 Tel: 972-8-936-3136 Fax: 972-8-936-5977 www.aeroscout.com Attn: Reviewing Engineer Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 RE: Confidentiality Request for: “AeroScout Exciter” model No. EX-3100 with FCC ID No. Q3H BS2040-1 To Whom It May Concern: This letter serves as an official request for confidentiality under FCC Rule Section 0.459. We have requested that the block diagram, schematics and part list required to be submit with this application be withheld from public review. This product includes Aeroscout intellectual property and a patent which was file is still pending. Please contact me if there is any information you may need. Sincerely, Edward Mirodin Senior RF Engineer AeroScout, Ltd Signature: Date: 06/02/2006

External Photos

External Photographs of Tested E.U.T. Figure 1 Front View Figure 2 Rear View Figure 3 Connectors

ID Label/Location Info

10 Oppenheimer St. Park Tamar, Rehovot, Israel, 76701 Tel: 972-8-936-3136 Fax: 972-8-936-5977 www.aeroscout.com Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 To whom it may concern: The AeroScout Exciter (EX-3100) label is too small to include the statement as specified in FCC part 15 Sub-part A section 15.19(a)(3): "This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference and (2) This device must accept any interference received, including interference that may cause undesired operation." Due to this reason we used the provisions of FCC Part 15 Sub-part A Section 15.19 (a)(5) and we placed this statement in a prominent location in the users manual. Sincerely, Edward Mirodin Senior RF Engineer Aeroscout, Ltd Signature: Date: 06/02/2006

ID Label/Location Info

Label EX-3100 Bar Code P/N: 100-2035-0103 S/N: 430-1000-0001 MAC: 000CCC620214 Exciter www.aeroscout.com Made in Israel FCC ID: Q3H BS2040-1 This device complies with Part 15 of the FCC Rules 5V/12V0.5A/1.0A Label Dimension : 50x60 mm

ID Label/Location Info

page 1 Location of the label on the Exciter Back Side Label

Internal Photos

Figure 1 PCB in Cover Figure 2 PCB Side 1 Figure 3 PCB Side 2

Operational Description

The Exciter is a 125kHz transmitter which is powered from either 5VDC or 12 VDC source. The Exciter can be connected to another Exciter for chaining or programming or can act as standalone Exciter with no connection to the server. The Exciter is a 125kHz ASK modulated beacon which transmits the same message in a preprogrammed transmission interval. The messages transmitted by Exciter cause the AeroScout Tag to wakeup and transmit a reply message to the AeroScout location receivers. In order to cover large gates or chokepoints several Exciters may be chained one to the other.

Test Report

Cert. No. 1152.01 Electrical (EMC) Test Report E64270.01 AeroScout Ltd. Page 1 of 50 FCC ACC M Ver 1.1 05Mayl 2000 DATE: 23 February 2006 I.T.L. (PRODUCT TESTING) LTD. FCC EMC/Radio Test for AeroScout Ltd. Equipment under test: Exciter EX-3100 Written by: _____________________________ D. Shidlowsky, Documentation Approved by: _____________________________ E. Pitt, Test Engineer Approved by: _____________________________ I. Raz, EMC Laboratory Manager This report must not be reproduced, except in full, without the written permission of I.T.L. (Product Testing) Ltd. This report relates only to items tested. Cert. No. 1152.01 Electrical (EMC) Test Report E64270.01 AeroScout Ltd. Page 2 of 50 FCC ACC M Ver 1.1 05Mayl 2000 Measurement/Technical Report for AeroScout Ltd. Exciter EX-3100 FCC ID:Q3H BS2040-1 23 February 2006 This report concerns: Original Grant x Class II change Class B verification Class A verification Class I change Equipment type: Low Power Transmitter Below 1705kHz Request Issue of Grant: x Immediately upon completion of review Limits used: CISPR 22 Part 15 x Measurement procedure used is ANSI C63.4-2003. Application for Certification Applicant for this device: prepared by: (different from "prepared by") Ishaishou Raz Reuven Amsalem ITL (Product Testing) Ltd. AeroScout Ltd. Kfar Bin Nun 10 Oppenheimer St. Park Tamar D.N. Shimshon 99780 Rechovot 76701 Israel Israel e-mail [email protected] Tel: +972-8 -9363136 Fax: +972-8-9365977 e-mail: [email protected] Test Report E64270.00 AeroScout Ltd. Page 3 of 50 FCC ACC M Ver 1.1 05Mayl 2000 TABLE OF CONTENTS 1. GENERAL INFORMATION -------------------------------------------------------------------------------5 1.1 Administrative Information.................................................................................5 1.2 List of Accreditations .........................................................................................6 1.3 Product Description ...........................................................................................7 1.4 Test Methodology..............................................................................................7 1.5 Test Facility .......................................................................................................8 1.6 Measurement Uncertainty .................................................................................8 2. PRODUCT LABELING ------------------------------------------------------------------------------------9 3. SYSTEM TEST CONFIGURATION--------------------------------------------------------------------10 3.1 Justification......................................................................................................10 3.2 EUT Exercise Software ...................................................................................10 3.3 Special Accessories ........................................................................................10 3.4 Equipment Modifications .................................................................................10 3.5 Configuration of Tested System ......................................................................11 4. BLOCK DIAGRAM-----------------------------------------------------------------------------------------12 4.1 Schematic Block/Connection Diagram............................................................12 4.2 Theory of Operation ........................................................................................12 5. CONDUCTED AND RADIATED MEASUREMENT PHOTOS ----------------------------------13 6. CONDUCTED EMISSION DATA-----------------------------------------------------------------------14 6.1 Test Specification ............................................................................................14 6.2 Test Procedure................................................................................................14 6.3 Measured Data................................................................................................15 6.4 Test Instrumentation Used, Conducted Measurement ...................................20 7. RADIATED EMISSION, 9 KHZ – 30 MHZ, 12VDC ------------------------------------------------21 7.1 Test Specification ............................................................................................21 7.2 Test Procedure................................................................................................21 7.3 Measured Data................................................................................................21 7.4 Test Instrumentation Used, Radiated Measurements ....................................24 7.5 Field Strength Calculation ...............................................................................25 8. RADIATED EMISSION, 9 KHZ – 30 MHZ, 5VDC--------------------------------------------------26 8.1 Test Specification ............................................................................................26 8.2 Test Procedure................................................................................................26 8.3 Measured Data................................................................................................26 8.4 Test Instrumentation Used, Radiated Measurements ....................................29 8.5 Field Strength Calculation ...............................................................................30 9. RADIATED EMISSION, 30 MHZ –1 GHZ ------------------------------------------------------------31 9.1 Test Specification ............................................................................................31 9.2 Test Procedure................................................................................................31 9.3 Measured Data................................................................................................32 9.4 Test Instrumentation Used, Radiated Measurements ....................................37 9.5 Field Strength Calculation ...…

Text truncated - open the document above for the full version.

Test Setup Photos

Conducted and Radiated Measurement Photos Figure 1. Conducted Emission Test. Figure 2. Radiated Emission Test

Contact Information

Applicant

Reuven Amsalem(VP HW R&D)
[email protected]972-8-9369301Fax: 972-8-9365977

Test Firm

Israel Testing LaboratoriesIIan Cohen
[email protected]972-3-5339022Fax: 972-3-5339019

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.125 MHz - 0.125 MHz-
Confidentiality
Long Term

Other Applications from AeroScout

Asset Tag - FCC ID Q3HTAG1200SB - AeroScout
Q3HTAG1200SB

Asset Tag

Oct 09, 2023

Equipment Class

DTS - Digital Transmission System
Fall Monitor, M200 - FCC ID Q3HM200 - AeroScout
Q3HM200

Fall Monitor, M200

Jan 05, 2021

Equipment Class

DTS - Digital Transmission System
T12s Asset Tag - FCC ID Q3HTAG1200S - AeroScout
Q3HTAG1200S

T12s Asset Tag

Mar 22, 2020

Equipment Class

DTS - Digital Transmission System
AeroScout TAG-P1000 - FCC ID Q3HTAGP1000 - AeroScout
Q3HTAGP1000

AeroScout TAG-P1000

Aug 26, 2015

Equipment Class

DTS - Digital Transmission System
Tag/Exciter Deployment (TED) Tool TED-1000 - FCC ID Q3HTED - AeroScout
Q3HTED

Tag/Exciter Deployment (TED) Tool TED-1000

Jul 01, 2015

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz