Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
AeroScout EX5100 Exciter User’s Guide EX5100-UG-040313-02 Disclaimer The information and know-how included in this document are the exclusive property of AeroScout Inc. and are intended for the use of the addressee or the user alone. The addressees shall not forward to another their right of using the information, know-how or document forwarded herewith, in whole or in part in all matters relating or stemming from or involved therein, whether for consideration or without consideration, and shall not permit any third party to utilize the information, know-how or the documents forwarded herewith or copies or duplicates thereof, unless at the company’s consent in advance and in writing. Any distribution, advertisement, copying or duplication in any form whatsoever is absolutely prohibited. The Company reserves the right to sue the addressee, user and/or any one on their behalves, as well as third parties, in respect to breaching its rights pertaining to the intellectual rights in particular and its rights of whatever kind or type in the information, know- how or the documents forwarded by them herewith in general, whether by act or by omission. This document is confidential and proprietary to AeroScout Inc. and is not to be distributed to any persons other than licensed AeroScout Visibility System users or other persons appointed in writing by AeroScout Inc. Trademark Acknowledgements AeroScout™ is a trademark of AeroScout, Inc. Other brand products and service names are trademarks or registered trademarks of their respective holders. Below is a partial listing of other trademarks or registered trademarks referenced herein: Cisco™ is a trademark of Cisco Systems, Inc. Sun, Sun Microsystems, the Sun Logo, Java, JRE and all other Sun trademarks, logos, product names, service names, program names and slogans that are referred to or displayed in this document are trademarks or registered trademarks of Sun Microsystems, Inc. in the United States and other countries. This product includes software developed by the Apache Software Foundation (http://www.apache.org/). This product includes code licensed from RSA Data Security Esper is a trademark of EsperTech, Inc. Jboss is a trademark of Red Hat Middleware, LLC. Oracle 10G and Oracle 11G are registered trademarks of Oracle Corporation and/or its affiliates. MS SQL Server 2005 and MS SQL Server 2008 are registered trademarks of Microsoft Corporation in the United States and/or other countries. JasperSoft, the JasperSoft Logo, JasperReports, the JasperReports logo, JasperIntelligence, JasperDecisions, JasperAnalysis, Scope Center, Scope Designer, and JasperServer are trademarks or registered trademarks of JasperSoft, Inc. in the United States and other countries. Images of PLUM A+™, PLUM A+™ 3, LIFECARE PCA™, and SYMBIQ™ infusion systems are provided with permission of Hospira, Inc. All rights reserved. Copyright ©2011 AeroScout Inc. All rights reserved. AeroScout EX5100 Exciter Table of Contents 3 Table of Contents Introduction ......................................................................................................................... 4 Application and Industry Examples ................................................................................ 5 EX5100 Features .................................................................................................................. 5 EX5100 Hardware ............................................................................................................... 6 Connecting the EX5100 to the Network and Power Source ....................................... 10 Chaining Exciters .............................................................................................................. 15 Resetting the EX5100 ........................................................................................................ 18 Exciter Configuration ....................................................................................................... 18 Mounting the Exciter ....................................................................................................... 23 EX5100 and Accessories Model Numbers ..................................................................... 24 EX5100 Specifications ....................................................................................................... 25 Appendix A. Slave Exciter Configuration Tool ........................................................... 27 Safety and Warnings ........................................................................................................ 31 AeroScout EX5100 Exciter Introduction 4 Introduction The AeroScout EX5100 Exciter is a component of the AeroScout suite of enterprise visibility solutions that enables location-based applications. The EX5100 extends the AeroScout suite to provide robust and sophisticated RFID detection capabilities, using the same AeroScout tags that can also be accurately located in real time by the AeroScout system. The EX5100 triggers AeroScout’s tags as they pass through a choke point or when they are located near the Exciter and the tags in turn transmit Wi-Fi message to Internal Receiver or compatible Access Points in range. The Exciter can activate/deactivate the tags, program the tags or even cause tag reaction such as blinking. This provides instant acknowledgment that a tagged asset passed through a gate, doorway or some other well-defined area. The EX5100 Exciter has built in Wi-Fi receiver which enables it to receive AeroScout tag messages. The Exciter also has an embedded Wi-Fi transmitter which is utilized by the Exciter for self-health monitoring. These capabilities make the Exciter ideal for security applications. The detection capabilities of the EX5100, combined with the location features of the AeroScout Visibility System, make the AeroScout suite the most sophisticated enterprise visibility solution for a wide variety of industries. Figure 1: EX5100 positione…
Text truncated - open the document above for the full version.
FCC Confidential Authorization Date: 3/19/12 To: Timco Engineering Inc. To Whom It May Concern We hereby authorize Mr. Shaike Raz of I.T.L. (Product Testing) Ltd (ITL) to act on our behalf regarding the FCC ID Certification Process for the following application: FCC ID: Q3HEX5100 Thank you, Sincerely, Signature: Reuven Amsalem VP HW R&D
Date: 3/19/12 Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID: Q3HEX5100. Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Block Diagram, Schematics, part list. CONF APPENDIX EX-5100 BlkDia.pdf CONF APPENDIX EX-5100 PartsLst.pdf CONF APPENDIX EX-5100 Schem.pdf The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Signature: Reuven Amsalem VP HW R&D
Date: 27/12/12 To: Federal Communications Commission. To Whom It May Concern I hereby attest that the computer peripheral portion of the EX-5100 Exciter, FCC ID: Q3HEX5100, was tested for compliance with the FCC DoC procedure. Thank you, Sincerely, Reuven Amsalem VP R&D AeroScout Ltd.
EX-5100 – LF Exciter with internal Wi-Fi Receiver The AeroScout EX5100 Exciter is a component of the AeroScout suite of enterprise visibility solutions that enables location-based applications. The EX5100 extends the AeroScout suite to provide robust and sophisticated RFID detection capabilities, using the same AeroScout tags that can also be accurately located in real time by the AeroScout system. The EX5100 triggers AeroScout’s tags as they pass through a choke point or when they are located near the Exciter and the tags in turn transmit Wi-Fi message to Internal Receivers or compatible Access Points in range. The Exciter can activate/deactivate the tags, program the tags or even cause tag reaction such as blinking. This provides instant acknowledgment that a tagged asset passed through a gate, doorway or some other well-defined area. The EX5100 Exciter has built in Wi-Fi receiver which enables it to receive AeroScout tag messages. The Exciter also has an embedded Wi-Fi transmitter which is utilized by the Exciter for self-health monitoring. These capabilities make the Exciter ideal for security applications. The detection capabilities of the EX5100, combined with the location features of the AeroScout Visibility System, make the AeroScout suite the most sophisticated enterprise visibility solution for a wide variety of industries. Figure 1: EX5100 positioned at choke point triggering a tag
Date: 3/19/12 Declaration Subject: Tune up procedure Concerning the Mobile Access FCC ID: Q3HEX5100 No manual tune-up procedure required. Sincerely, Signature: Reuven Amsalem VP HW R&D
Test Report E111051.00 AeroScout Ltd. Page 1 of 79 FCC ACC M Ver 1.2 28 February 2011 DATE: 07 February 2013 I.T.L. (PRODUCT TESTING) LTD. FCC Radio Test Report for AeroScout Ltd. Equipment under test: Exciter EX-5100 Written by: _____________________________ D. Shidlowsky, Documentation Approved by: For/__________________________ A. Moses, Test Engineer Approved by: _____________________________ I. Raz, EMC Laboratory Manager This report must not be reproduced, except in full, without the written permission of I.T.L. (Product Testing) Ltd. This report relates only to items tested. Test Report E111051.00 AeroScout Ltd. Page 2 of 79 FCC ACC M Ver 1.2 28 February 2011 Measurement/Technical Report for AeroScout Ltd. Exciter EX-5100 FCC ID: Q3HEX5100 IC: 5115A-EX5100 This report concerns: Original Grant: X Class I Change: Class II Change: Equipment type: Part 15 Low Power Transmitter Below 1705 kHz Digital Transmission System Limits used: 47CFR15 Sections 15.205; 15.209; 15.247 Measurement procedure used is ANSI C63.4-2003 and KDB 558074 D01 18 January 2012. Application for Certification Applicant for this device: prepared by: (different from "prepared by") Ishaishou Raz Reuven Amsalem ITL (Product Testing) Ltd. 3 Pekeris St. Park Tamar Kfar Bin Nun Rechovot 76702 D.N. Shimshon 99780 Israel Israel Tel: +972-8- 936-3136 e-mail [email protected] Fax: +972-8- 936-5977 e-mail: [email protected] Test Report E111051.00 AeroScout Ltd. Page 3 of 79 FCC ACC M Ver 1.2 28 February 2011 TABLE OF CONTENTS 1. GENERAL INFORMATION ------------------------------------------------------------------------------- 5 1.1 Administrative Information ................................................................................. 5 1.2 List of Accreditations ......................................................................................... 6 1.3 Product Description ........................................................................................... 7 1.4 Test Methodology .............................................................................................. 7 1.5 Test Facility ....................................................................................................... 7 1.6 Measurement Uncertainty ................................................................................. 7 2. SYSTEM TEST CONFIGURATION --------------------------------------------------------------------- 8 2.1 Justification ........................................................................................................ 8 2.2 EUT Exercise Software ..................................................................................... 8 2.3 Special Accessories .......................................................................................... 8 2.4 Equipment Modifications ................................................................................... 8 2.5 Configuration of Tested System ........................................................................ 9 3. CONDUCTED AND RADIATED MEASUREMENT TEST SET-UP PHOTO----------------- 10 4. CONDUCTED EMISSION FROM AC MAINS ------------------------------------------------------- 12 4.1 Test Specification ............................................................................................ 12 4.2 Test Procedure ................................................................................................ 12 4.3 Test Results..................................................................................................... 12 4.4 Test Equipment Used, Conducted Emission from AC Mains Test .................. 17 5. AVERAGE FACTOR CALCULATION 125 KHZ TRANSMITTER ------------------------------ 18 5.1 Test Equipment Used, Average Factor Calculation ........................................ 20 6. FIELD STRENGTH OF FUNDAMENTAL 125 KHZ TRANSMITTER ------------------------- 21 6.1 Test Specification ............................................................................................ 21 6.2 Test Procedure ................................................................................................ 21 6.3 Test Results..................................................................................................... 21 6.4 Test Instrumentation Used, Field Strength of Fundamental ............................ 23 7. SPURIOUS RADIATED EMISSION, 9 KHZ – 30 MHZ, 125 KHZ TRANSMITTER -------- 24 7.1 Test Specification ............................................................................................ 24 7.2 Test Procedure ................................................................................................ 24 7.3 Test Results..................................................................................................... 24 7.4 Test Equipment Used, Spurious Radiated Measurements 9 kHz -30 MHz, 125 kHz Transmitter ........................................................................................ 26 7.5 Field Strength Calculation ............................................................................... 26 8. SPURIOUS RADIATED EMISSION, 30 – 1000 MHZ, 125 KHZ TRANSMITTER ---------- 27 8.1 Test Specification ............................................................................................ 27 8.2 Test Procedure ................................................................................................ 27 8.3 Test Data ......................................................................................................... 27 8.4 Test Equipment Used, Spurious Radiated Emission, 30 -1000 MHz, 125 kHz Transmitter ........................................................................................ 29 8.5 Field Strength Calculation ............................................................................... 29 9. 6 DB MINIMUM BANDWIDTH 2.4 GHZ TRANSMITTER ---------------------------------------- 30 9.1 Test Specification ...........................................................................…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.125 MHz - 0.125 MHz | - |

Asset Tag
Equipment Class
DTS - Digital Transmission System
Fall Monitor, M200
Equipment Class
DTS - Digital Transmission System
T12s Asset Tag
Equipment Class
DTS - Digital Transmission System
AeroScout TAG-P1000
Equipment Class
DTS - Digital Transmission System
Tag/Exciter Deployment (TED) Tool TED-1000
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz