FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

Β© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. K&B International Ltd./
  3. Q5K12737T

Q5K12737TR/C Robotic Insect

K&B International Ltd.
R/C Robotic Insect - FCC ID Q5K12737T - K&B International Ltd.
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Jan 25, 2007
Application Purpose
Original Equipment
Date of Application
Jan 24, 2007
Equipment Note
R/C Robotic Insect
Frequency Range
27.14500000 - 27.14500000
Company
K&B International Ltd.
Country
Hong Kong

Documents & Files

Select a file to view

Users Manual

β†—

Block Diagram

β†—

Cover Letter(s)

β†—

External Photos

β†—

ID Label/Location Info

β†—

Internal Photos

β†—

Operational Description

β†—

Schematics

β†—

Test Report

β†—
β†—
β†—

Test Setup Photos

β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Block Diagram

3V Encoder TX-2 Control Key 27.145MHZ Oscillator RF Amplify Q1,L2,T1,L1

Operational Description

Operation Description for R/C Robotic Insect The R/C Robotic Insect is powered by 2 x 1.5V size batteries. There are two buttons switch to control receiver. When the button is pressed once, it will transmit the radio control to receiver. Referring to the transmitter circuit design, the circuit description is listed below: - Y1, Q2, and associated circuit act as oscillator. - Q1 and associated circuit act as RF amplify. - U1 and associated circuit act as encoder.

Test Report

TEST REPORT Report No. : AG033145-001 Date : 2007 January 17 Page 1 of 11 FCC ID: Q5K12737T This document shall not be reproduced except in full or with written approval by the laboratory. CMA Industrial Development Foundation Limited Room 1302, Yan Hing Centre, 9-13 Wong Chuk Yeung St.., Fo Tan, Shatin, Hong Kong. Tel: (852) 2698 8198 Fax: (852) 2695 4177 E-mail: [email protected] Web Site: http://www.cmatcl.com Application No. : LG223468(3) Applicant : K & B INTERNATIONAL LTD. RM. 406, EMPIRE CTR., 68 MODY ROAD, T.S.T. EAST, KLN., HONG KONG. Sample Description : One(1) submitted sample(s) stated to be R/C ROBOTIC INSECT of Model No. KR-1273 Radio Frequency : 27.145MHz Transmitter Rating : 2 x 1.5V AA size batteries No. of submitted sample : Two(2) set(s) Date Received : 2006 December 22 Test Period : 2006 December 22 Γ± 2007 January 03 Test Requested : FCC Part 15 Certification. Test Method : 47 CFR Part 15 (10-1-05 Edition) ANSI C63.4 Γ± 2003 Test Result : See attached sheet(s) from page 2 to 11. Conclusion : The submitted sample was found to comply with requirement of FCC Part 15 Subpart C. For and on behalf of CMA Industrial Development Foundation Limited Authorized Signature : ____________________________________________________ Danny Chui Deputy Manager - EL. Division TEST REPORT Report No. : AG033145-001 Date : 2007 January 17 Page 2 of 11 FCC ID: Q5K12737T This document shall not be reproduced except in full or with written approval by the laboratory. CMA Industrial Development Foundation Limited Room 1302, Yan Hing Centre, 9-13 Wong Chuk Yeung St.., Fo Tan, Shatin, Hong Kong. Tel: (852) 2698 8198 Fax: (852) 2695 4177 E-mail: [email protected] Web Site: http://www.cmatcl.com Table of Contents 1 General Information .............................................................................................................................3 1.1 General Description .....................................................................................................................3 1.2 Location of the test site ................................................................................................................4 1.3 List of measuring equipment........................................................................................................5 2 Description of the radiated emission test .............................................................................................6 2.1 Test Procedure..............................................................................................................................6 2.2 Test Result....................................................................................................................................6 2.3 Radiated Emission Measurement Data ........................................................................................7 3 Description of the Line-conducted Test...............................................................................................8 3.1 Test Procedure..............................................................................................................................8 3.2 Test Result....................................................................................................................................8 3.3 Graph and Table of Conducted Emission Measurement Data .....................................................8 4 Photograph ...........................................................................................................................................9 4.1 Photographs of the Test Setup for Radiated Emission and Conduction Emission ......................9 4.2 Photographs of the External and Internal Configurations of the EUT.........................................9 5 Supplementary document ...................................................................................................................10 5.1 Bandwidth ..................................................................................................................................10 5.2 Duty cycle ..................................................................................................................................10 5.3 Transmission time ......................................................................................................................10 6 Appendices .........................................................................................................................................11 TEST REPORT Report No. : AG033145-001 Date : 2007 January 17 Page 3 of 11 FCC ID: Q5K12737T This document shall not be reproduced except in full or with written approval by the laboratory. CMA Industrial Development Foundation Limited Room 1302, Yan Hing Centre, 9-13 Wong Chuk Yeung St.., Fo Tan, Shatin, Hong Kong. Tel: (852) 2698 8198 Fax: (852) 2695 4177 E-mail: [email protected] Web Site: http://www.cmatcl.com 1 General Information 1.1 General Description The equipment under test (EUT) is a transmitter for R/C Robotic Insect. It operates at 27.145MHz which is controlled by a crystal. The EUT is powered by 2 x 1.5V AA size batteries. There are two control buttons in the EUT. When the forward or backward button is pressed once, it will transmit different radio control signal to receiver. The brief circuit description is listed as follows: - U1 and associated circuit act as encoder. - Y1, Q2 and associated circuit act as oscillator. - Q1 and associated circuit act as RF amplify. TEST REPORT Report No. : AG033145-001 Date : 2007 January 17 Page 4 of 11 FCC ID: Q5K12737T This document shall not be reproduced except in full or with written approval by the laboratory. CMA Industrial Development Foundation Limited Room 1302, Yan Hing Centre, 9-13 Wong Chuk Yeung St.., Fo Tan, Shatin, Hong Kong. Tel: (852) 2698 8198 Fax: (852) 2695 4177 E-mail: [email protected] Web Site: http://www.cmatcl.com 1.2 Location of the test site Radiated emissions measurements are investigated an…

Text truncated - open the document above for the full version.

Test Report

Job No.: _______________ WF-EL-EMC-15 Edition 1 2006 April 12 Page of Bandwidth Plot Bandwidth 1

Test Report

Job No.: _______________ WF-EL-EMC-15 Edition 1 2006 April 12 Page of Duty Cycle Duty Cycle 1 Duty Cycle 2 Job No.: _______________ WF-EL-EMC-15 Edition 1 2006 April 12 Page of Duty Cycle 3

Contact Information

Applicant

Shek Shek(Admin)
[email protected]85223689622Fax: 85223681236

Technical Contact

CMA Testing and Certification LaboratoriesDanny Chui
[email protected]852 2690 8251

Room 1302, Yan Hing Centre 9-13 Β· Fo Tan , Shatin Β· Hong Kong

Test Firm

CMA Industrial Development Foundations LimitedStephen Lam
[email protected]852-2690-8282Fax: 852-2695-4177

Technical Specifications

#Rule PartsFrequency RangePower Output
115C27.145 MHz - 27.145 MHz-

Other Applications from K&B International Ltd.

R/C Catapult - FCC ID Q5K60231T - K&B International Ltd.
Q5K60231T

R/C Catapult

Jul 02, 2007

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
R/C Catapult - FCC ID Q5K60232T - K&B International Ltd.
Q5K60232T

R/C Catapult

Jul 02, 2007

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
R/C Catapult - FCC ID Q5K60232R - K&B International Ltd.
Q5K60232R

R/C Catapult

Jul 01, 2007

Equipment Class

CRR - Superregenerative Receiver
Remote Control Toy Transmitter - FCC ID Q5K12609T - K&B International Ltd.
Q5K12609T

Remote Control Toy Transmitter

May 22, 2007

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Remote Control Toy Robot - FCC ID Q5K12609R - K&B International Ltd.
Q5K12609R

Remote Control Toy Robot

May 22, 2007

Equipment Class

CRR - Superregenerative Receiver