Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Report No.: 130617E06 Page 1 CONSTRUCTION PHOTOS OF EUT Report No.: 130617E06 Page 2 Report No.: 130617E06 Page 10 Report No.: 130617E06 Page 11 Report No.: 130617E06 Page 12 Adapter: SAW-0501000 Report No.: 130617E06 Page 13 Report No.: 130617E06 Page 14 Report No.: 130617E06 Page 15
YTL091label&labellocation FCC ID : Q6U-YTL091-911-16
Report No.: 130617E06 Page 3 Report No.: 130617E06 Page 4 Report No.: 130617E06 Page 5 Report No.: 130617E06 Page 6 Report No.: 130617E06 Page 7 Report No.: 130617E06 Page 8 Report No.: 130617E06 Page 9
FCC ID: Q6U-YTL091-911-16 Report No.: RF130617E06 Operational Description This device is a Bluetooth Speaker, IceDiamond+, IceDiamond2, IceDiamond3, BlackDiamond+, BlackDiamond3, IceDiamond. The transmitter of the EUT is powered by 5Vdc from host devices or AC adapter. The antenna is PCB without antenna connector. For more detailed instruction, please take a look at the user’s manual.
Report No.: SA130617E06 1 of 6 Report Format Version 5.0.0 RF EXPOSURE REPORT REPORT NO.: SA130617E06 MODEL NO.: YTL091, YTL911, YTL912, YTL913, YTL914, YTL915, YTL916 FCC ID: Q6U-YTL091-911-16 RECEIVED: June 17, 2013 TESTED: June 26, 2013 ISSUED: Aug. 01, 2013 APPLICANT: Yantouch Corporation ADDRESS: Rm. 303, 4F-1., No.5, Xin’an Rd., Hsinchu Science Park, Hsinchu City 300, Taiwan (R.O.C.) ISSUED BY: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Hsin Chu Laboratory LAB ADDRESS: No. 81-1, Lu Liao Keng, 9th Ling,Wu Lung Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan, R.O.C. This report should not be used by the client to claim product certification, approval, or endorsement by any government agencies. This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification Report No.: SA130617E06 2 of 6 Report Format Version 5.0.0 TABLE OF CONTENTS RELEASE CONTROL RECORD .................................................................................... 3 1. CERTIFICATION .................................................................................................... 4 2. EVALUATION RESULT ......................................................................................... 5 3. SAR TEST EXCLUSION THRESHOLDS............................................................... 6 4. CONCLUSION ....................................................................................................... 6 Report No.: SA130617E06 3 of 6 Report Format Version 5.0.0 RELEASE CONTROL RECORD ISSUE NO. REASON FOR CHANGE DATE ISSUED SA130617E06 Original release Aug. 01, 2013 Report No.: SA130617E06 4 of 6 Report Format Version 5.0.0 1. CERTIFICATION PRODUCT: Bluetooth Speaker, IceDiamond+, IceDiamond2, IceDiamond3, BlackDiamond+, BlackDiamond3, IceDiamond BRAND NAME: Yantouch MODEL NO.: YTL091, YTL911, YTL912, YTL913, YTL914, YTL915, YTL916 TEST SAMPLE: ENGINEERING SAMPLE APPLICANT: Yantouch Corporation TESTED DATE: June 26, 2013 STANDARDS: FCC Part 2 (Section 2.1091) FCC OET Bulletin 65, Supplement C (01-01) IEEE C95.1 The above equipment (Model: YTL091) has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample’s EMC characteristics under the conditions specified in this report. PREPARED BY : , DATE: Mar. 01, 2013 ( Lori Chung, Specialist ) APPROVED BY : , DATE: Mar. 01, 2013 ( May Chen, Manager ) Report No.: SA130617E06 5 of 6 Report Format Version 5.0.0 2. EVALUATION RESULT Following FCC KDB 447498 D01 “General SAR test exclusion guidance” The corresponding SAR Exclusion Threshold condition, listed below: 1) The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR where ÿ f(GHz) is the RF channel transmit frequency in GHz ÿ Power and distance are rounded to the nearest mW and mm before calculation ÿ The result is rounde d to one decimal place for comparison The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. 2) At 100 MHz to 6 GHz and for test separation distances > 50 mm, the SAR test exclusion threshold is determined according to the following: a) [Threshold at 50 mm in step 1) + (test separation distance - 50 mm)·( f(MHz)/150)] mW, at 100MHz to 1500 MHz b) [Threshold at 50 mm in step 1) + (test separation distance - 50 mm)·10] mW at > 1500 MHz and ≤ 6 GHz 3) At frequencies below 100 MHz, the following may be considered for SAR test exclusion. a) The threshold at the corresponding test separation distance at 100 MHz in step 2) is multiplied by [1 + log(100/f(MHz))] for test separation distances > 50 mm and < 200 mm. b) The threshold determined by the equation in a) for 50 mm and 100 MHz is multiplied by ½ for test separation distances ≤ 50 mm. c) SAR measurement procedures are not established below 100 MHz. When SAR test exclusion cannot be applied, a KDB inquiry is required to determine SAR evaluation requirements for any test results to be acceptable. Report No.: SA130617E06 6 of 6 Report Format Version 5.0.0 3. SAR TEST EXCLUSION THRESHOLDS Maximum measured transmitter power: Frequency (GHz) Max. Power (mW) Min. test separation distance (mm) SAR test exclusion calculation value (NOTE 2) 1g SAR test exclusion th…
Text truncated - open the document above for the full version.
Report No.: RF130617E06 1 of 47 Report Format Version 5.0.1 FCC TEST REPORT REPORT NO.: RF130617E06 MODEL NO.: YTL091, YTL911, YTL912, YTL913, YTL914, YTL915, YTL916 FCC ID: Q6U-YTL091-911-16 RECEIVED: June 17, 2013 TESTED: June 26 to July 17, 2013 ISSUED: Aug. 01, 2013 APPLICANT: Yantouch Corporation ADDRESS: Rm. 303, 4F-1., No.5, Xin’an Rd., Hsinchu Science Park, Hsinchu City 300, Taiwan (R.O.C.) ISSUED BY: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Hsin Chu Laboratory LAB ADDRESS: No. 81-1, Lu Liao Keng, 9th Ling,Wu Lung Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan, R.O.C. TEST LOCATION (1): No. 81-1, Lu Liao Keng, 9th Ling,Wu Lung Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan, Taiwan, R.O.C. TEST LOCATION (2): No.49, Ln. 206, Wende Rd., Shangshan Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan, Taiwan, R.O.C. This report should not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies. This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification Report No.: RF130617E06 2 of 47 Report Format Version 5.0.1 TABLE OF CONTENTS RELEASE CONTROL RECORD ........................................................................................................ 4 1 CERTIFICATION ................................................................................................................ 5 2 SUMMARY OF TEST RESULTS ......................................................................................... 6 2.1 ME ASUREMENT UNCERTAINTY ..................................................................................... 7 3 GENERAL INFORMATION ................................................................................................. 8 3.1 GENERAL DESCRIPTION OF EUT .................................................................................... 8 3.2 DESCRIPTION OF TEST MODES .....................................................................................10 3.3 TEST MODE APPLICABLITY AND TESTED CHANNEL DETAIL: ...................................... 11 3.4 GENERAL DESCRIPTION OF APPLIED STANDARDS .....................................................13 3.5 DESCRIPTION OF SUPPORT UNITS ...............................................................................14 3.6 CONFIGURATION OF SYSTEM UNDER TEST.................................................................14 4 TEST PROCEDURES AND RESULTS ..............................................................................15 4.1 CONDUCTED EMISSION MEASUREMENT .....................................................................15 4.1.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT....................................................15 4.1.2 TEST INSTRUMENTS .......................................................................................................15 4.1.3 TEST PROCEDURE ..........................................................................................................16 4.1.4 DEVIATION FROM TEST STANDARD ..............................................................................16 4.1.5 TEST SETUP ....................................................................................................................16 4.1.6 EUT OPERATING CONDITIONS .......................................................................................17 4.1.7 TEST RESULTS ................................................................................................................18 4.2 RADIATED EMISSION AND BANDEDGE MEASUREMENT ..............................................20 4.2.1 LIMITS OF RADIATED EMISSION AND BANDEDGE MEASUREMENT ............................20 4.2.2 TEST INSTRUMENTS .......................................................................................................21 4.2.3 TEST PROCEDURES .......................................................................................................22 4.2.4 DEVIATION FROM TEST STANDARD ..............................................................................22 4.2.5 TEST SETUP ....................................................................................................................23 4.2.6 EUT OPERATING CONDITIONS .......................................................................................23 4.2.7 TEST RESULTS ................................................................................................................24 4.3 NUMBER OF HOPPING FREQUENCY USED ..................................................................28 4.3.1 LIMIT OF HOPPING FREQUENCY USED .........................................................................28 4.3.2 TEST INSTRUMENTS .................................................................................................…
Text truncated - open the document above for the full version.
Report No.: 120702E04 1 of 2 PHOTOGRAPHS OF THE TEST CONFIGURATION CONDUCTED EMISSION TEST Report No.: 120702E04 2 of 2 RADIATED EMISSION TEST
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.00 mW |

EYE1 (Black or White)
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Bluetooth gateway
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
BlackDiamond3
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter