FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Hideki Electronics Limited/
  3. Q9PPCR325W1

Q9PPCR325W1Atomic Projection Clock

Hideki Electronics Limited
Atomic Projection Clock - FCC ID Q9PPCR325W1 - Hideki Electronics Limited
Click to zoom

Application Details

Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
Date of Grant
Feb 03, 2015
Application Purpose
Original Equipment
Date of Application
Feb 03, 2015
Equipment Note
Atomic Projection Clock
Frequency Range
434.00000000 - 434.00000000
Company
Hideki Electronics Limited
Country
Hong Kong

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

KSPO: 0882-13(HAM) Hammacher Schlemmer PCR325/TS02 MANUAL(ENG) SIZE:W105 X H148(mm) BY Lai HZ 17/12/13 USER'S MANUAL INTRODUCTION Congratulations on your purchase of the Hammacher Schlemmer Projection Alarm Clock and Weather Monitor. The basic package comes with a main unit (the weather forecast station), two remote wireless weather sensing units (operating at 433 MHz), and an AC adapter (AC 120V, 60Hz-DC5.0V, 100mA). PRECAUTIONS This product is engineered to give you years of satisfactory service if handled carefully. Here are a few precautions: 1. Do not immerse the unit in water. 2. Do not clean the unit with abrasive or corrosive materials. They may scratch the plastic parts and corrode the electronic circuits. 3. Do not subject the unit to excessive force, shock, dust, temperature, or humidity, which may result in malfunctions, shorter lifespan, damaged batteries, and damaged parts. 4. Do not tamper with the unit's internal components. Doing so will invalidate the warranty and may cause damage. The unit contains no user-serviceable parts. 5. Only use fresh batteries. Do not mix new and old batteries. 6. Read the user's manual thoroughly before operating the unit. A. LCD DISPLAY For easy reading of indoor and outdoor weather conditions, calendar, and clock. B. CHANNEL BUTTON Toggles between the three remote sensor readings. C. ALARM BUTTON For setting alarm and displaying alarm status. D. MODE BUTTON Toggles between display modes and allows manual setting of clock and calendar. E. LIGHT/SNOOZE BUTTON Activates the snooze function and backlighting. F. DOWN (-) BUTTON Decreases the value of a setting. G. UP (+) BUTTON Advances the value of a setting. H. BATTERY COMPARTMENT For two “AA” batteries. I. PROJECTION LIGHT AND ADJUSTMENT * Press E / I [LIGHT/SNOOZE]- Projection light will come on and turn off automatically after 5 seconds. * Turn the dial J [ROTATE] to manually rotate the projection display. * Press button K [FLIP] to rotate the projection display 180°. * Turn the focus dial L [FOCUS] to adjust the sharpness of projection display. * When AC adapter is plugged in, slide button M [CONTINUE - PROJECTION] for continuous time and temperature projection. N. LIGHT SENSOR BUTTON When the AC adapter is plugged in, position the light sensor switch at: * “AUTO” for automatic LCD backlighting when the room grows dark. * “ON” for continuous LCD backlighting. * “OFF” to deactivate LCD backlighting. NOTE: AC Adapter must be plugged in for the light sensor option to work O. LIGHT SENSOR P.OUTDOOR TEMPERATURE Remote unit temperature Q. INDOOR TEMPERATURE Main unit temperature MAIN FEATURES: REMOTE UNIT(S) A. LED INDICATOR Flashes once when the remote unit transmits a reading to the main unit. Flashes twice to indicate low battery. B. BATTERY COMPARTMENT For two “AA” batteries. C. RESET BUTTON Resets unit in case of channel selection change. D. CHANNEL SELECTOR To coordinate the sensor with the main unit, select the desired channel number before installing batteries. E. WALL-MOUNT RECESSED HOLE MANUAL SETTINGS It is necessary to set the desired US TIME ZONE. 1. Press MODE button so that the Day of the Week abbreviation is displayed to the right of the time; for example 2:37 TU. 2. Select the Time Zone by pressing and holding “+” button for 3 seconds. 3. Keeping holding “+” button until the desired US Time Zone (Pacific, Mountain, Central, Pacific) is highlighted on the display’s US map, located to the right of the time display above the day of the week. 4. Release the “+” button, the Time Zone is set. HOW TO SET THE CLOCK MANUALLY Press and hold MODE for 3 seconds: the display will flash the year. Press “+” or “-” to change the values of the flashing digits. After the first value is set, press MODE again. Continue setting month, day, hour, minutes, language, and Fahrenheit or Celsius display option. When you’ve set the last value, press MODE a final time to return to regular mode. Display will stop flashing. The clock can also be set atomically. See section How to Set the Radio Controlled Clock. P Q The Hammacher Schlemmer Projection Alarm Clock and Weather Monitor. BEFORE YOU BEGIN For best operation, 1. Insert batteries into remote sensors before inserting batteries in the main unit. 2. Position the remote units and main unit within effective transmission range, typically up to 100 feet. Note that the effective range depends upon many factors, including structural surroundings. Though the remote units are weatherproof, they should be placed away from direct sunlight, rain, and snow. BATTERY INSTALLATION: REMOTE UNITS 1. Remove the screws on the battery compartment. 2. Select the desired channel. 3. Install 2 alkaline “AA” batteries. 4. Replace battery compartment door and secure screws. BATTERY INSTALLATION: MAIN UNIT 1. Open the battery compartment door. 2. Install 2 alkaline “AA”. 3. Replace the battery compartment door. LOW BATTERY WARNING A low-battery indicator [ ] will appear on the indoor or outdoor temperature reading to show when the corresponding sensor’s batteries need replaced. GETTING STARTED After batteries are installed, remote sensors will transmit temperature readings at 45 second intervals. The main unit may take up to two minutes to receive the initial readings; upon successful reception, outdoor temperatures will be displayed. The main unit will automatically update readings at about 45-second intervals. If no signals are received by the main unit after two minutes, “-- ” will be displayed. Hold [-] for 2 seconds to begin another signal search. If no signals are received, try moving the base unit closer to the remote sensor, face the remote sensor towards the base unit, and minimize obstructions such as doors and walls between the sensor and base unit. 2 3 45 67 To install the AC adapter for Continuous Projection: Use 2 AA batteries and the included AC adapter (AC120V, 60Hz-DC5.0V, 100mA). PROJECTION IMAGE OF CURRENT TIME AND OUTDOOR TEMPERATURE: 1. 2. Press "FLIP" to rot…

Text truncated - open the document above for the full version.

Cover Letter(s)

HIDEKI ELECTRONICS LIMITED 西城電子有限公司 西城電子有限公司西城電子有限公司 西城電子有限公司 (A SUBSIDIARY OF K & P INTERNATIONAL HOLDINGS LIMITED) UNITS 2304-06, 23/F., RILEY HOUSE, 88 LEI MUK ROAD, KWAI CHUNG, HONG KONG. 香港葵涌梨木道88號達利中心23樓2304至2306室 TEL: (852) 2426 0138 FAX: (852) 2480 5372 FCC Confidential Authorization Date: 2015-01-19 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Confidentiality Request regarding application for certification of FCC ID: Q9PPCR325W1 Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below:  Detailed Circuit Schematics of EUT--- (Long term)  Block Diagram--- (Long term)  Circuit Description--- (Long term) The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely Yours, Thomas Lai Engineering Manager

External Photos

Page 1 of 5 EXHIBIT B - EUT EXTERNAL PHOTOGRAPHS EUT – All View EUT – Top View Page 2 of 5 EUT – Bottom View EUT –Side View Page 3 of 5 EUT –Side View EUT –Side View Page 4 of 5 EUT –Side View EUT –Side View Page 5 of 5 EUT –Adapter View EUT –Adapter Label View

ID Label/Location Info

EXHIBIT A - FCC ID LABELING AND LOCATION FCC ID Label Proposed FCC ID Label Location The label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time purchase (Labeling requirements per 2.925)

Internal Photos

Page 1 of 8 EXHIBIT C - EUT INTERNAL PHOTOGRAPHS EUT – Uncover View EUT – Antenna View Page 2 of 8 EUT –Uncover View EUT –Uncover View Page 3 of 8 EUT –Subboard 1 Top View EUT –EUT –Subboard 1 Bottom View Page 4 of 8 EUT – Antenna View EUT – Uncover View Page 5 of 8 EUT –Main Board Top View EUT –Main Board Bottom View Page 6 of 8 EUT – Key Board Top View EUT –Key Board Bottom View Page 7 of 8 EUT – LED Board Top View EUT –LED Board Botom View Page 8 of 8 EUT –Subboard 2 Top View EUT –Subboard 2 Botom View

Test Report

Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Dongguan). This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. FCC PART 15 B TEST REPORT For Hideki Electronics Limited UNITS 2304-06, 23/F., RILEY HOUSE, 88 LEI MUK ROAD, KWAI CHUNG, HONG KONG. FCC ID: Q9PPCR325W1 Report Type: Original Report Product Type: Atomic Projection Clock Te s t E n g i n e e r : Dean Liu Report Number: RDG150106003-00 Report Date: 2015-01-15 Reviewed By: Sula Huang RF Engineer Test Laboratory: Bay Area Compliance Laboratories Corp. (Dongguan) No.69 Pulongcun, Puxinhu Industrial Zone, Tangxia, Dongguan, Guangdong, China Tel: +86-769-86858888 Fax: +86-769-86858891 www.baclcorp.com.cn Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG150106003-00 FCC Part 15 B Page 2 of 18 TABLE OF CONTENTS GENERAL INFORMATION ....................................................................................................................................... 3 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .................................................................................... 3 OBJECTIVE ................................................................................................................................................................... 3 RELATED SUBMITTAL(S)/GRANT(S) ............................................................................................................................. 3 TEST METHODOLOGY .................................................................................................................................................. 3 TEST FACILITY ............................................................................................................................................................. 3 SYSTEM TEST CONFIGURATION .......................................................................................................................... 4 DESCRIPTION OF TEST CONFIGURATION ...................................................................................................................... 4 EUT EXERCISE SOFTWARE .......................................................................................................................................... 4 EQUIPMENT MODIFICATIONS ....................................................................................................................................... 4 SUPPORT EQUIPMENT LIST AND DETAILS .................................................................................................................... 4 EXTERNAL CABLE ........................................................................................................................................................ 4 CONFIGURATION OF TEST SETUP ................................................................................................................................. 5 SUMMARY OF TEST RESULTS ............................................................................................................................... 6 FCC§15.107 - CONDUCTED EMISSIONS ................................................................................................................ 7 MEASUREMENT UNCERTAINTY .................................................................................................................................... 7 EUT SETUP .................................................................................................................................................................. 7 EMI TEST RECEIVER SETUP ......................................................................................................................................... 8 TEST EQUIPMENT LIST AND DETAILS ........................................................................................................................... 8 TEST PROCEDURE ........................................................................................................................................................ 8 CORRECTED AMPLITUDE & MARGIN CALCULATION ................................................................................................... 8 TEST RESULTS SUMMARY ............................................................................................................................................ 9 TEST DATA .................................................................................................................................................................. 9 FCC §15.109 - RADIATED SPURIOUS EMISSIONS ............................................................................................ 12 MEASUREMENT UNCERTAINTY .................................................................................................................................. 12 EUT SETUP ................................................................................................................................................................ 12 EMI TEST RECEIVER SETUP ....................................................................................................................................... 13 TEST PROCEDURE ...................................................................................................................................................... 14 TEST EQUIPMENT LIST AND DETAILS ......................................................................................................................... 14 CORRECTED AMPLITUDE & MARGIN CALCULATION ................................................................................................. 14 TEST RESULTS SUMMARY .....................................................................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

EXHIBIT D - TEST SETUP PHOTOGRAPHS Conducted Emissions – Front View Conducted Emissions - Side View Radiated Emissions –Front View (Below 1GHz) Radiated Emissions –Rear View (Below 1GHz) Radiated Emission –Front View (Above 1 GHz) Radiated Emission –Rear View (Above 1 GHz)

Contact Information

Applicant

Thomas Lai(Engineering Manager)
[email protected]852-24260138Fax: 852-24805372

Test Firm

Bay Area Compliance Laboratories Corp. (Dongguan)John Chan
[email protected]86-769-86858888

Technical Specifications

#Rule PartsFrequency RangePower Output
115B434 MHz - 434 MHz-
Confidentiality
Long Term

Other Applications from Hideki Electronics Limited

Wireless Thermo-Hygrometer and Wireless Thermometer - FCC ID Q9PTS21 - Hideki Electronics Limited
Q9PTS21

Wireless Thermo-Hygrometer and Wireless Thermometer

Sep 02, 2010

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Thermo-Hygro Sensor - FCC ID Q9PTS35-C - Hideki Electronics Limited
Q9PTS35-C

Thermo-Hygro Sensor

May 31, 2007

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Professional Weather Station with Remote Control - FCC ID Q9PTE923W-EL-NL - Hideki Electronics Limited
Q9PTE923W-EL-NL

Professional Weather Station with Remote Control

Jul 09, 2006

Equipment Class

CRR - Superregenerative Receiver
Thermo-Hygrometer Sensor - FCC ID Q9PTS24C-34C - Hideki Electronics Limited
Q9PTS24C-34C

Thermo-Hygrometer Sensor

Jul 09, 2006

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Anemometer - FCC ID Q9PTS805 - Hideki Electronics Limited
Q9PTS805

Anemometer

Jul 09, 2006

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter