FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. MENIX CO., LTD./
  3. QDYARC-300F

QDYARC-300FWIRELESS REMOTE CONTROLLER

MENIX CO., LTD.
WIRELESS REMOTE CONTROLLER - FCC ID QDYARC-300F - MENIX CO., LTD.
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Jun 27, 2010
Application Purpose
Original Equipment
Date of Application
Jun 27, 2010
Equipment Note
WIRELESS REMOTE CONTROLLER
Frequency Range
426.27500000 - 426.27500000
Company
MENIX CO., LTD.
Country
South Korea

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

CYBEREYE Wireless Transmitters ■ TRANSMITTER (ARC-300F) Thanks for purchasing this product. Please make sure that you read & keep product manual thoroughly for safe & efficient use. ARC-300F is a remote control to transmit electric waves to initiate the operation of CYBEREYE, alarm device, wireless siren an d wire emergency lamp. ■ PRODUCT COMPONENTS 1 remote control, 1 manual ※ ARC-300F transmitters sold as a set with other optional devices are produced with code-input completed. Accordingly, if you would like to purchase additional ARC-300F, please contact dealer regarding code-input. ■ OPERATION Press “ ARMED ” button for more than 2 seconds. Red lamp will be turned on and operation will be initiated. Press “ OFF ” button. Red lamp will be turned on and operation will be disarmed. Press “ EMERGENCY ” button for more than 1second. Red lamp will be turned on and main unit sends emergency signal to the user and other optional devices. ※ Please ignore blinking Red lamp when you continually press the “ Emergency ” button. It only uses for manufacturer. ■ HOW TO INSERT & REPLACE BATTERY Put a coin into a groove of remote control and turn it. After replace battery, press the case and combine them as shown in Figure (2) ※ Please use it after checking of case combination ※ Insert a battery with correct polarity ■ INSTRUCTION FOR USE Use the remote control with its front side headed for the main body. ■ SPECIFICATION - Distance if use : Within 80m (Varies depending on su rrounding conditions) - Battery : CR2032/3V lithium battery 1ea - Weight : 25 g - Battery life : 2 years - Device name : Wireless system for security ■ WARNING Change or modifications not expressly approved by manufacturer could void the user ’ s authority operate the equipment. ■ FCC INFORMATION This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions; (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Figure (2). Battery Replacement

Cover Letter(s)

Menix Co., Ltd. 539, Yongsan-dong, Yuseong-gu, Daejeon, 305-500, Korea Tel: +82-42-930-9478, Fax: +82-42-934-6245 Date: June 10, 2010 FCC Laboratory 7435 Oakland Mills Road Columbia, MD 21046 Attention: Application Examiner Reviewing Engineer Re: Request for confidentiality per Section 0.459 of FCC Rules Applicant: Menix Co., Ltd. FCC ID: QDYARC-300F To whom it may concern, Request is hereby submitted, on behalf of my client, Menix Co., Ltd., to withhold from public review certain portions of the application for equipment certification for the referenced FCC identifier. In particular, the following sections of the application and report are requested to be kept confidential: Schematics Block Diagram Operational Description Parts List Rationale for request for confidentiality: Menix Co., Ltd., has invested considerable time and materials in research and development to produce the referenced product. Disclosure of the confidential portions of this application to competitors would give them competitive advantage in developing similar products. If you have questions or need further information, please contact the undersigned. Sincerely Yours, _________________________ Mr. GYU-CHEOL KIM / Manager Menix Co., Ltd. Tel: +82-42-930-9478 E-Mail: [email protected]

Cover Letter(s)

Menix Co., Ltd. 539, Yongsan-dong, Yuseong-gu, Daejeon, 305-500, Korea Tel: +82-42-930-9478, Fax: +82-42-934-6245 Date: June 10, 2010 Compliance Certification Services Certification Division 561F Monterey Road Morgan Hill, CA 95037 This authorization is valid until further written notice from the applicant. Sincerely Yours, _________________________ Mr. GYU-CHEOL KIM / Manager Menix Co., Ltd. Tel: +82-42-930-9478 Fax: +82-42-934-6245 E-Mail: [email protected]

External Photos

FCC ID. : QDYARC-300F Page 1 of 2 Report No. : E106R-014 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003(Rev.1) HEAD OFFICE : #505 SK Apt. Factory, 223-28 Sangdaewon1-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do 462-121 Korea (TEL: 82-31-746-8500 FAX: 82-31-746-8700) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea.(TEL: 82-31-765-8289 FAX: 82-31-766-2904) FCC ID. : QDYARC-300F Page 2 of 2 Report No. : E106R-014 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003(Rev.1) HEAD OFFICE : #505 SK Apt. Factory, 223-28 Sangdaewon1-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do 462-121 Korea (TEL: 82-31-746-8500 FAX: 82-31-746-8700) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea.(TEL: 82-31-765-8289 FAX: 82-31-766-2904)

ID Label/Location Info

FCC ID. : QDYARC-300F Page 1 of 1 Report No. : E106R-014 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003(Rev.1) HEAD OFFICE : #505 SK Apt. Factory, 223-28 Sangdaewon1-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do 462-121 Korea (TEL: 82-31-746-8500 FAX: 82-31-746-8700) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea.(TEL: 82-31-765-8289 FAX: 82-31-766-2904) IDENTIFICATION LABEL: PROPOSED FCC ID LABEL Due to the product size, only the FCC ID shall be permanently affixed to the rear side of the equipment and other information shall be placed in the instruction manual. FCC ID : QDYARC-300F FCC ID AREA

Internal Photos

FCC ID. : QDYARC-300F Page 1 of 3 Report No. : E106R-014 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003(Rev.1) HEAD OFFICE : #505 SK Apt. Factory, 223-28 Sangdaewon1-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do 462-121 Korea (TEL: 82-31-746-8500 FAX: 82-31-746-8700) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea.(TEL: 82-31-765-8289 FAX: 82-31-766-2904) FCC ID. : QDYARC-300F Page 2 of 3 Report No. : E106R-014 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003(Rev.1) HEAD OFFICE : #505 SK Apt. Factory, 223-28 Sangdaewon1-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do 462-121 Korea (TEL: 82-31-746-8500 FAX: 82-31-746-8700) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea.(TEL: 82-31-765-8289 FAX: 82-31-766-2904) FCC ID. : QDYARC-300F Page 3 of 3 Report No. : E106R-014 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003(Rev.1) HEAD OFFICE : #505 SK Apt. Factory, 223-28 Sangdaewon1-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do 462-121 Korea (TEL: 82-31-746-8500 FAX: 82-31-746-8700) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea.(TEL: 82-31-765-8289 FAX: 82-31-766-2904)

Test Report

FCC ID. : QDYARC-300F Page 1 of 14 Report No. : E106R-014 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003(Rev.1) HEAD OFFICE : #505 SK Apt. Factory, 223-28 Sangdaewon1-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do 462-121 Korea (TEL: 82-31-746-8500 FAX: 82-31-746-8700) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea.(TEL: 82-31-765-8289 FAX: 82-31-766-2904) ELECTROMAGNETIC EMISSION COMPLIANCE REPORT FOR LOW-POWER, NON-LICENSED TRANSMITTER Test Report No. : E106R-014 AGR No : A103A-221 Applicant : Menix Co., Ltd. Address : 539, Yongsan-dong, Yuseong-gu, Daejeon, 305-500, Korea Manufacturer : Menix Co., Ltd. Address : 539, Yongsan-dong, Yuseong-gu, Daejeon, 305-500, Korea Type of Equipment : WIRELESS REMOTE CONTROLLER FCC ID. : QDYARC-300F Model Name : ARC-300F Serial number : None Total page of Report : 14 pages (including this page) Date of Incoming : May 13, 2010 Date of issue : June 09, 2010 SUMMARY The equipment complies with the regulation; FCC Part 15 Subpart C Section 15.231. This test report only contains the result of a single test of the sample supplied for the examination. It is not a generally valid assessment of the features of the respective products of the mass-production. Prepared by: Reviewed by: Young-Min, Choi / Asst. Chief Engineer Y. K. Kwon / Managing Director EMC/RF Center EMC/RF Center ONETECH Corp. ONETECH Corp. FCC ID. : QDYARC-300F Page 2 of 14 Report No. : E106R-014 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003(Rev.1) HEAD OFFICE : #505 SK Apt. Factory, 223-28 Sangdaewon1-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do 462-121 Korea (TEL: 82-31-746-8500 FAX: 82-31-746-8700) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea.(TEL: 82-31-765-8289 FAX: 82-31-766-2904) CONTENTS PAGE 1. VERIFICATION OF COMPLIANCE .............................................................................................4 2. GENERAL INFORMATION ............................................................................................................5 2.1 PRODUCT DESCRIPTION.....................................................................................................................................................5 2.2 MODEL DIFFERENCES........................................................................................................................................................5 2.3 RELATED SUBMITTAL(S) / GRANT(S)................................................................................................................................5 2.4 PURPOSE OF THE TEST.......................................................................................................................................................5 2.5 TEST METHODOLOGY........................................................................................................................................................5 2.6 TEST FACILITY...................................................................................................................................................................5 3. SYSTEM TEST CONFIGURATION ...............................................................................................6 3.1 JUSTIFICATION...................................................................................................................................................................6 3.2 PERIPHERAL EQUIPMENT...................................................................................................................................................6 3.3 MODE OF OPERATION DURING THE TEST...........................................................................................................................6 3.4. EUT MODIFICATIONS.................................................................................................................................................6 3.5 CONFIGURATION OF TEST SYSTEM...................................................................................................................................6 3.6 ANTENNA REQUIREMENT..................................................................................................................................................7 4. PRELIMINARY TEST ......................................................................................................................7 4.1 AC POWER LINE CONDUCTED EMISSIONS TESTS.............................................................................................................7 4.2 GENERAL RADIATED EMISSIONS TESTS............................................................................................................................7 5. FINAL RESULT OF MEASURMENT ............................................................................................8 5.1 FIELD STRENGTH OF THE CARRIER TEST.........................................................................................................................8 5.2 TRANSMITTER TRANSMISSION DURATION........................................................................................................................9 5.3 SPURIOUS EMISSION TEST...............................................................................................................................................10 5.4 BANDWIDTH OF THE OPERATING FREQUENCY................................................................................................................11 6. FIELD STRENGTH CALCULATION ..........................................................................................13 7. LIST OF TEST EQUIPMENT ........................................................................................................14 FCC ID. : QDYARC-300F Page 3 of 14 Report No. : E106R-014 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003(Rev.…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID. : QDYARC-300F Page 1 of 2 Report No. : E106R-014 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003(Rev.1) HEAD OFFICE : #505 SK Apt. Factory, 223-28 Sangdaewon1-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do 462-121 Korea (TEL: 82-31-746-8500 FAX: 82-31-746-8700) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea.(TEL: 82-31-765-8289 FAX: 82-31-766-2904) Radiated Emission Test FCC ID. : QDYARC-300F Page 2 of 2 Report No. : E106R-014 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003(Rev.1) HEAD OFFICE : #505 SK Apt. Factory, 223-28 Sangdaewon1-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do 462-121 Korea (TEL: 82-31-746-8500 FAX: 82-31-746-8700) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea.(TEL: 82-31-765-8289 FAX: 82-31-766-2904)

Contact Information

Applicant

GYU-CHEOL KIM(MANAGER)
[email protected]

Test Firm

ONETECH Corp.Ki Hong Nam
[email protected]82-31-799-9580Fax: 82-31-799-9599

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231426.275 MHz - 426.275 MHz-
Confidentiality
Long Term

Other Applications from MENIX CO., LTD.

WIRELESS TRANSMITTER - FCC ID QDYWT-200NF - MENIX CO., LTD.
QDYWT-200NF

WIRELESS TRANSMITTER

Jun 27, 2010

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
Security Camera - FCC ID QDYIC-100M - MENIX CO., LTD.
QDYIC-100M

Security Camera

May 29, 2002

Equipment Class

CRR - Superregenerative Receiver
Remote Control - FCC ID QDYRC-200 - MENIX CO., LTD.
QDYRC-200

Remote Control

May 29, 2002

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter