FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Itron/
  3. QHC-OPENWAY20

QHC-OPENWAY20Cellular/ PCS GSM/ GPRS Power Meter with Zigbee Transmitter

Itron
Cellular/ PCS GSM/ GPRS Power Meter with Zigbee Transmitter - FCC ID QHC-OPENWAY20 - Itron
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jan 04, 2010
Application Purpose
Original Equipment
Date of Application
Jan 03, 2010
Equipment Note
Cellular/ PCS GSM/ GPRS Power Meter with Zigbee Transmitter
Frequency Range
2405.00000000 - 2475.00000000
Company
Itron
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

   2006 SmartSynch™ SmartMeter™ System SSI OPENWAY 2.0 SmartMeter User Guide SMR45-4601B SSI OPENWAY 2.0 SmartMeter User Guide SMR45-4601B 2 Copyrights Copyright 2006 SmartSynch ® , Inc. All rights reserved. No part of this documentation may be reproduced transmitted, processed, or recorded by any means or form, or be released to any third party without the express written consent of SmartSynch, Inc. Trademarks SmartSynch ® , SmartSynch logo, TMS™, and SmartMeter™ are trademarks or registered trademarks of SmartSynch, Inc. All other companies, brands, and product names listed herein are trademarks or registered trademarks of their respective holders. Document Revisions The SSI OPENWAY 2.0 SmartMeter User Guide can be referred to by its document number: SMR45- 4601A. Each revision of this document is designated with a letter, beginning with “A”. SmartSynch, Inc. reserves the right to revise this publication and to make any modifications to its content, at any time, without obligation to notify any party, person, or entity of such revisions or changes. Occasionally, changes or variations exist in the products that are not reflected in the documentation. Generally, if such changes or variations are known to exist and affect the product significantly, release notes will accompany the documentation. The information in this guide should not be considered as all-inclusive or covering all cases for events that may occur. If further information is required, consult your technical support representative. See the License Agreement contained in the product for complete license information. Contact your technical support representative for more information on any of our products. SSI OPENWAY 2.0 SmartMeter User Guide SMR45-4601B 3 Table of Contents 1 INTRODUCTION ...............................................................................................................................................5 1.1 ABOUT THIS GUIDE........................................................................................................................................5 1.2 REFERENCE MATERIALS.................................................................................................................................5 1.3 CONTACTING SMARTSYNCH...........................................................................................................................5 1.3.1 Technical Support ..................................................................................................................................5 1.3.2 Documentation Feedback ......................................................................................................................6 1.3.3 SmartSynch Headquarters .....................................................................................................................6 2 GETTING STARTED.........................................................................................................................................7 2.1 OPERATIONS...................................................................................................................................................7 2.2 SAFETY PRECAUTIONS....................................................................................................................................7 2.2.1 Interference with Medical Equipment....................................................................................................7 2.2.2 Fire or Explosion Hazards ....................................................................................................................7 2.2.3 Interference with Other Devices ............................................................................................................8 2.3 PREREQUISITES...............................................................................................................................................8 3 INSTALLING THE CENTRON SMARTMETER ..........................................................................................9 3.1 PRELIMINARY INSPECTIONS............................................................................................................................9 3.2 INSTALLATION PROCESS.................................................................................................................................9 3.2.1 Option 1: Direct Field Installation ........................................................................................................9 3.2.2 Option 2: Meter Shop Test and Field Installation .................................................................................9 3.2.3 Meter Installation ..................................................................................................................................9 3.3 PROVISIONING THE SMARTMETER...............................................................................................................10 4 TROUBLESHOOTING ....................................................................................................................................11 4.1 TROUBLESHOOTING PROCESS FLOW.............................................................................................................11 4.2 TROUBLESHOOTING PROCESS DESCRIPTION.................................................................................................12 5 CENTRON DISPLAY FEATURE...................................................................................................................14 6 REQUIREMENTS AND COMPLIANCE ......................................................................................................16 SSI OPENWAY 2.0 SmartMeter User Guide SMR45-4601B 5 1 Introduction 1.1 About This Guide This document is a manual designed to help guide you through the testing, installation and activation of your SSI OPENWAY 2.0 SmartMeter. This manual provides general instructions on the support of your SmartMeter and references to supporting manufac…

Text truncated - open the document above for the full version.

Cover Letter(s)

From: Mike Mathis Sent: Monday, January 04, 2010 10:39 AM To: PCTEST TCB/CB Subject: RE: Questions Regarding FCC ID: QHC-OPENWAY20 Hello Please find attached Itron’s Operational Description for the DTS transmitter. The response to question #2 is that the two antennas listed are the only ones that will be marketed with the d evice. Best Regards Mike Mathis From: PCTEST TCB/CB Sent: Monday, December 28, 2009 6:42 PM To: Mike Mathis Subject: Questions Regarding FCC ID: QHC-OPENWAY20 T o: Mr. Mike Mathis / Smartsynch Inc. From: Mr. Gregory Czumak / PCTEST TCB RE: FCC ID: QHC-OPENWAY20 Applicant: SMARTSYNCH Correspondence Reference Number: QHC91422 Co nfirmation Number: 911231422-3 Date of Original Email: December 28, 2009 Subject: Request for additional information In regards to your recent TCB application referenced above, we kindly request that you provide the following additional information. 1. Please submit an operational description for the DTS (Zigbee) transmitter that describes the RF section of the device. 2. The Installation Guide does not provide the maximum permitted antennas gains per band, but only lists “acceptable” antennas. Are these described antennas always marketed with the EUT? If not, please revise the Installation Guide to include the maximum permitted gains per band and resubmit it. The items indicated above must be submitted before pr ocessing can continue on the above referenced application. Sincerely, Gregory Czumak Senior Certification Engineer Quality Manager PCTEST Engineering Laboratory, Inc. 6660-B Dobbin Road Columbia, MD 21045 410-290-6652 410-290-6654 (Fax) [email protected] T his communication and its attachments contain inform ation from PCTEST Engineering Laboratory, Inc., and is intended for the exclusive use of the recipient (s) named above. It may contain information that is confidential and/or legally privileged. Any unauthorized use that may compromise that confidentiality via distribution or disclosure is prohibited. Please notify the sender immediately if you receive this communication in error, and delete it from your computer system. Usage of PCTEST email addresses for non-business related activities is strictly prohibited. No warranty is made that the e-mail or attachment(s) are free from computer virus or other defect. Thank you.

External Photos

SMARTSYNCH INC. FCC ID: QHC-OPENWAY20 Model: SSI Openway 2.0 External Photos EUT Type: Smartmeter Page 1 of 4 © 2009 PCTEST Engineering Laboratory Inc. EXTERNAL PHOTOGRAPHS SMARTSYNCH INC. FCC ID: QHC-OPENWAY20 Model: SSI Openway 2.0 External Photos EUT Type: Smartmeter Page 2 of 4 © 2009 PCTEST Engineering Laboratory Inc. SMARTSYNCH INC. FCC ID: QHC-OPENWAY20 Model: SSI Openway 2.0 External Photos EUT Type: Smartmeter Page 3 of 4 © 2009 PCTEST Engineering Laboratory Inc. SMARTSYNCH INC. FCC ID: QHC-OPENWAY20 Model: SSI Openway 2.0 External Photos EUT Type: Smartmeter Page 4 of 4 © 2009 PCTEST Engineering Laboratory Inc.

Internal Photos

SMARTSYNCH INC. FCC ID: QHC-OPENWAY20 Model: SSI Openway 2.0 Internal Photos EUT Type: Smartmeter Page 1 of 8 © 2009 PCTEST Engineering Laboratory Inc. INTERNAL PHOTOGRAPHS SMARTSYNCH INC. FCC ID: QHC-OPENWAY20 Model: SSI Openway 2.0 Internal Photos EUT Type: Smartmeter Page 2 of 8 © 2009 PCTEST Engineering Laboratory Inc. SMARTSYNCH INC. FCC ID: QHC-OPENWAY20 Model: SSI Openway 2.0 Internal Photos EUT Type: Smartmeter Page 3 of 8 © 2009 PCTEST Engineering Laboratory Inc. SMARTSYNCH INC. FCC ID: QHC-OPENWAY20 Model: SSI Openway 2.0 Internal Photos EUT Type: Smartmeter Page 4 of 8 © 2009 PCTEST Engineering Laboratory Inc. SMARTSYNCH INC. FCC ID: QHC-OPENWAY20 Model: SSI Openway 2.0 Internal Photos EUT Type: Smartmeter Page 5 of 8 © 2009 PCTEST Engineering Laboratory Inc. SMARTSYNCH INC. FCC ID: QHC-OPENWAY20 Model: SSI Openway 2.0 Internal Photos EUT Type: Smartmeter Page 6 of 8 © 2009 PCTEST Engineering Laboratory Inc. SMARTSYNCH INC. FCC ID: QHC-OPENWAY20 Model: SSI Openway 2.0 Internal Photos EUT Type: Smartmeter Page 7 of 8 © 2009 PCTEST Engineering Laboratory Inc. SMARTSYNCH INC. FCC ID: QHC-OPENWAY20 Model: SSI Openway 2.0 Internal Photos EUT Type: Smartmeter Page 8 of 8 © 2009 PCTEST Engineering Laboratory Inc.

RF Exposure Info

Reviewed by: FCC ID: QHC-OPENWAY20 MAXIMUM PERMISSIBLE EXPOSURE (MPE) DATA REPORT Quality Manager Test Report S/N: Test Dates: EUT Type: 0911232150.QHC November 30, 2009 Smartmeter Page 1 of 7 © 2009 PCTEST Engineering Laboratory, Inc. REV 3.1MPE 02/09/09 Applicant Name: Date of Testing: SmartSynch Inc. November 30, 2009 4400 Old Canton Road, Suite 300 Test Site/Location: Jackson, MS 39211 PCTEST Lab, Columbia, MD, USA USA Test Report Serial No.: 0911232150.QHC FCC ID: QHC-OPENWAY20 APPLICANT: SmartSynch Inc. EUT Type: Smartmeter FCC Rule Part(s): FCC Part 1 (§1.1310) and Part 2 (§2.1091) FCC Classification: PCS Licensed Transmitter (PCB) Test Procedure: OET Bulletin 65 The device bearing the FCC Identifier specified above has been shown to comply with the applicable technical standards as indicated in the measurement report and has been tested in accordance with the measurement procedures specified in FCC OET Bulletin 65 (See Test Report). These measurements were performed with no deviation from the standards. Test results reported herein relate only to the item(s) tested. I authorize and attest to the accuracy of data. All measurements reported herein were performed by me or were made under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. PCTEST certifies that no party to this application has been denied the FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. PCTEST ENGINEERING LABORATORY, INC. 6660-B Dobbin Road, Columbia, MD 21045 USA Tel. 410.290.6652 / Fax 410.290.6554 http://www.pctestlab.com RF EXPOSURE EVALUATION (MAXIMUM PERMISSIBLE EXPOSURE) Reviewed by: FCC ID: QHC-OPENWAY20 MAXIMUM PERMISSIBLE EXPOSURE (MPE) DATA REPORT Quality Manager Test Report S/N: Test Dates: EUT Type: 0911232150.QHC November 30, 2009 Smartmeter Page 2 of 7 © 2009 PCTEST Engineering Laboratory, Inc. REV 3.1MPE 02/09/09 TABLE OF CONTENTS 1.0 RF EXPOSURE EVALUATION – MAXIMUM PERMISSIBLE EXPOSURE (MPE) .........................3 1.1 INTRODUCTION ................................................................................................................................... 3 1.2 EUT DESCRIPTION .............................................................................................................................. 3 1.3 MPE REQUIREMENTS OVERVIEW..................................................................................................... 4 1.4 PROCEDURE........................................................................................................................................ 5 1.5 SUMMARY OF RESULTS ..................................................................................................................... 6 2.0 CONCLUSION..................................................................................................................................7 Reviewed by: FCC ID: QHC-OPENWAY20 MAXIMUM PERMISSIBLE EXPOSURE (MPE) DATA REPORT Quality Manager Test Report S/N: Test Dates: EUT Type: 0911232150.QHC November 30, 2009 Smartmeter Page 3 of 7 © 2009 PCTEST Engineering Laboratory, Inc. REV 3.1MPE 02/09/09 1.0 RF EXPOSURE EVALUATION – MAXIMUM PERMISSIBLE EXPOSURE (MPE) 1.1 Introduction This document is prepared on behalf of SmartSynch Inc. to show compliance with the RF Exposure requirements as required in §1.1310 of the FCC Rules and Regulations and RSS-102 of Industry Canada. The limit for Maximum Permissible Exposure (MPE), specified in FCC §1.1310, is listed in Table 1-1. According to FCC §1.1310 and RSS-102: the criteria listed in the following table shall be used to evaluate the environmental impact of human exposure to radio-frequency (RF) radiation as specified in §1.1307(b). Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm 2 ) Average Time (Minutes) (A) Limits For Occupational / Control Exposures (f = frequency) 30-300 61.4 0.163 1.0 6 300-1500 ... ... f/300 6 1500-100,000 ... ... 5.0 6 (B) Limits For General Population / Uncontrolled Exposure (f = frequency) 30-300 27.5 0.073 0.2 30 300-1500 ... ... f/1500 30 1500-100,000 ... ... 1.0 30 Table 1-1. Limits for Maximum Permissible Exposure (MPE) 1.2 EUT Description The Smartsynch FCC ID: QHC-OPENWAY20 is a Smartmeter containing an Itron Zigbee module (separately certified under FCC ID: SK9AMI-4) and a Motorola GSM/GPRS module (separately certified under FCC ID: IHDT56HQ1). For this MPE evaluation the device is set to transmit from the antenna of each transmitter and the RF exposure of each transmitter is evaluated individually. EUT: Model: SSI Openway 2.0 Grantee: SmartSynch Inc. FCC ID: QHC-OPENWAY20 Antenna Gains: 4.4dBi – 2.4GHz Zigbee Transmitter Reviewed by: FCC ID: QHC-OPENWAY20 MAXIMUM PERMISSIBLE EXPOSURE (MPE) DATA REPORT Quality Manager Test Report S/N: Test Dates: EUT Type: 0911232150.QHC November 30, 2009 Smartmeter Page 4 of 7 © 2009 PCTEST Engineering Laboratory, Inc. REV 3.1MPE 02/09/09 1.3 MPE Requirements Overview Three different categories of transmitters are defined by the FCC in OET Bulletin 65. These categories are fixed installation, mobile, and portable and are defined as follows: o Fixed Installations: fixed location means that the device, including its antenna, is physically secured at a permanent location and is not able to be easily moved to another location. Additionally, distance to humans from the antenna is maintained to at least 2 meters. o Mobile Devices: a mobile device is defined as a transmitting device designed to be used in other than fixed locations and to be generally used in such a way that a separation distance of at least 20 centimeters is normally maintained between the transmitter's radiating structures and the body of the user or nearby persons. Transmitters designed to be used by consumers or workers that can be easily re-located, …

Text truncated - open the document above for the full version.

Test Report

Reviewed by: FCC ID: QHC-OPENWAY20 FCC Pt. 15.247 802.15.4 ZIGBEE TEST REPORT (CERTIFICATION) Quality Manager Test Report S/N: Test Dates: EUT Type: 0911232146.QHC November 23 - 24, 2009 Smartmeter Page 1 of 27 © 2009 PCTEST Engineering Laboratory, Inc. REV 2.8WBG 11/18/2009 Applicant Name: Date of Testing: SmartSynch Inc. November 23 - 24, 2009 4400 Old Canton Road, Suite 300 Test Site/Location: Jackson, MS 39211 PCTEST Lab, Columbia, MD, USA USA Test Report Serial No.: 0911232146.QHC FCC ID: QHC-OPENWAY20 APPLICANT: SmartSynch Inc. Model(s): SSI Openway 2.0 EUT Type: Smartmeter Max. RF Output Power: 32.06 mW (15.06 dBm) Peak Conducted Frequency Range: 2405 - 2475 MHz (DSSS) FCC Classification: Digital Transmission System (DTS) FCC Rule Part(s): Part 15.247 Test Device Serial No.: 6JF060901025, 6JF060901029 This equipment has been shown to be capable of compliance with the applicable technical standards as indicated in the measurement report and was tested in accordance with the measurement procedures specified in ANSI C-63.4-2003. Test results reported herein relate only to the item(s) tested. I attest to the accuracy of data. All measurements reported herein were performed by me or were made under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. Grant Conditions: Power output listed is conducted. PCTEST certifies that no party to this application has been denied the FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. PCTEST ENGINEERING LABORATORY, INC. 6660-B Dobbin Road, Columbia, MD 21045 USA Tel. 410.290.6652 / Fax 410.290.6554 http://www.pctestlab.com CERTIFICATE OF COMPLIANCE FCC PART 15.247 WLAN 802.15.4 Certification Reviewed by: FCC ID: QHC-OPENWAY20 FCC Pt. 15.247 802.15.4 ZIGBEE TEST REPORT (CERTIFICATION) Quality Manager Test Report S/N: Test Dates: EUT Type: 0911232146.QHC November 23 - 24, 2009 Smartmeter Page 2 of 27 © 2009 PCTEST Engineering Laboratory, Inc. REV 2.8WBG 11/18/2009 TABLE OF CONTENTS FCC PART 15.247 MEASUREMENT REPORT...................................................................................3 1.0 INTRODUCTION......................................................................................................................................4 1.1 SCOPE....................................................................................................................................................... 4 1.2 PCTEST TEST LOCATION........................................................................................................................ 4 2.0 PRODUCT INFORMATION .....................................................................................................................5 2.1 EQUIPMENT DESCRIPTION..................................................................................................................... 5 2.2 EMI SUPPRESSION DEVICE(S)/MODIFICATIONS.................................................................................. 5 2.3 LABELING REQUIREMENTS .................................................................................................................... 5 3.0 DESCRIPTION OF TEST ........................................................................................................................6 3.1 EVALUATION PROCEDURE..................................................................................................................... 6 3.2 CONDUCTED EMISSIONS........................................................................................................................ 6 3.3 RADIATED EMISSIONS ............................................................................................................................ 7 4.0 ANTENNA REQUIREMENTS ..................................................................................................................8 5.0 TEST EQUIPMENT CALIBRATION DATA..............................................................................................9 6.0 TEST RESULTS ....................................................................................................................................10 6.1 SUMMARY ............................................................................................................................................... 10 6.2 6DB BANDWIDTH MEASUREMENT .......................................................................................................11 6.3 OUTPUT POWER MEASUREMENT .......................................................................................................13 6.4 POWER SPECTRAL DENSITY ............................................................................................................... 14 6.5 CONDUCTED EMISSIONS AT THE BAND EDGE.................................................................................. 16 6.6 CONDUCTED SPURIOUS EMISSIONS .................................................................................................. 17 6.7 RADIATED SPURIOUS EMISSION MEASUREMENTS.......................................................................... 20 6.8 RADIATED RESTRICTED BAND EDGE MEASUREMENTS .................................................................. 24 6.9 LINE-CONDUCTED TEST DATA............................................................................................................. 25 7.0 CONCLUSION .......................................................................................................................................27 Reviewed by: FCC ID: QHC-OPENWAY20 FCC Pt. 15.247 802.15.4 ZIGBEE TEST REPORT (CERTIFICATION) Quality Manager Test Report S/N: Test Dates: EUT Type: 0911232146.QHC November 23 - 24, 2009 Smartmeter Page 3 of 27 © 2009 PCTEST Engineering Laboratory, Inc. REV 2.8WBG 11/18/2009 MEASUREMENT REPORT FCC Part 15.247 § 2.1033 General Information AP…

Text truncated - open the document above for the full version.

Test Setup Photos

SMARTSYNCH INC. FCC ID: QHC-OPENWAY20 Model: SSI Openway 2.0 Test Set-Up Photos EUT Type: Smartmeter Page 1 of 3 © 2009 PCTEST Engineering Laboratory Inc. TEST SETUP PHOTOGRAPHS SMARTSYNCH INC. FCC ID: QHC-OPENWAY20 Model: SSI Openway 2.0 Test Set-Up Photos EUT Type: Smartmeter Page 2 of 3 © 2009 PCTEST Engineering Laboratory Inc. SMARTSYNCH INC. FCC ID: QHC-OPENWAY20 Model: SSI Openway 2.0 Test Set-Up Photos EUT Type: Smartmeter Page 3 of 3 © 2009 PCTEST Engineering Laboratory Inc.

Contact Information

Applicant

Mike Mathis(Senior Compliance Engineer)
[email protected]601-362-1780Fax: 601-362-1787

Technical Contact

PCTEST Engineering Laboratory, Inc.Randy Ortanez
[email protected]410-290-6652

6660-B Dobbin Road · Columbia, Maryland · United States

Test Firm

Element Materials Technology Washington DC LLCRandy Ortanez
[email protected]410-290-6652Fax: 410 290 6654

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz32.00 mW
Confidentiality
Long Term
Grant Notes
Output power is conducted. This device is approved as a mobile transmitter with respect to RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operate in conjunction with any other antenna or transmitter except for those described in this filing. End-users must be provided with operating conditions for satisfying RF exposure compliance.

Other Applications from Itron

OpenWay 3.5P - FCC ID QHC-OW35PE - Itron
QHC-OW35PE

OpenWay 3.5P

Aug 17, 2015

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
OpenWay 3.5S - FCC ID QHC-OW35SE - Itron
QHC-OW35SE

OpenWay 3.5S

Apr 21, 2015

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
QHC-KVEVZE41

kV2c-AMPZE Module

Jun 19, 2014

Equipment Class

DTS - Digital Transmission System
QHC-060203A

OpenWay 3.1 Module

Dec 15, 2013

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
SmartSynch Interface Module - FCC ID QHC-010201A - Itron
QHC-010201A

SmartSynch Interface Module

Jan 07, 2013

Equipment Class

DTS - Digital Transmission System