FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Rocky Mountain Radar/
  3. QKK-RD1

QKK-RD1Radar Detector

Rocky Mountain Radar
Radar Detector - FCC ID QKK-RD1 - Rocky Mountain Radar
Click to zoom

Application Details

Equipment Class
CRD - Part 15 Radar Detector
Date of Grant
Nov 29, 2005
Application Purpose
Original Equipment
Date of Application
Nov 29, 2005
Equipment Note
Radar Detector
Frequency Range
33400.00000000 - 36000.00000000
Company
Rocky Mountain Radar
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Operational Description

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

Date : November 23, 2005 EMCC DR. RASEK CERTIFICATION INSTITUTE – Boelwiese 5 91320 Ebermannstadt Germany Subject : Confidentiality request regarding application for certification of FCC ID: QKK-RD1 Pursuant to section 0.457 and 0.459 of the commission’s rules, we hereby request confidential treatment of information accompany this application as outlined bellow; Block Diagram Schematic Diagram(s) The above material contained trade secrets and proprietary information not customarily released to public. The public disclosure of these materials may be harmful to the applicant The applicant understands that pursuant to section 0.457 of the Rules, Disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application Sincerely Signature Name : Hyung Seok, Lee Title : Chief Engineer of EMC Team Company : E-Rae Testing Laboratory Inc. 584, SangWhal-ri, Ganam-myoun, Youju-kun, Kyoungki-Do, Korea Tel : +82-31-885-0072 Fax: +82-31-885-0074

External Photos

Appendix C. External Photographs E05.1123.FCC.731N / Page C1 of C3 Head Office: # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea / Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab: #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel:82-31-885-0072, Fax:82-31-885-0074 Form NO: ETL(E)004A4001201-0 Front View of EUT Rear View of EUT Appendix C. External Photographs E05.1123.FCC.731N / Page C2 of C3 Head Office: # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea / Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab: #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel:82-31-885-0072, Fax:82-31-885-0074 Form NO: ETL(E)004A4001201-0 View of Front Receiver View of Rear Receiver Appendix C. External Photographs E05.1123.FCC.731N / Page C3 of C3 Head Office: # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea / Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab: #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel:82-31-885-0072, Fax:82-31-885-0074 Form NO: ETL(E)004A4001201-0 View of setup EUT

ID Label/Location Info

Appendix A. FCC ID Label and Location E05.1123.FCC.731N / Page A1 of A1 Head Office: # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea / Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab: #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel: 82-31-885-0072, Fax:82-31-885-0074 Form NO: ETL(E)004A4001201-0 Product label sample with FCC label information Following is a sample copy of the label that will be placed on the rear cabinet of the product. The FCC ID label and compliance statement are marked in the product label. Rocky Mountain Radar RADAR DETECTOR Made in Korea FCC ID : QKK-RD1 Model No. : RMR-8RD Serial No : N/A This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Label Location The label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time purchase.(Labeling requirements per 2.925) Label here

Internal Photos

Appendix D. Internal Photographs E05.1123.FCC.731N / Page D1 of D9 Head Office: # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea / Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab: #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel:82-31-885-0072, Fax:82-31-885-0074 Form NO: ETL(E)004A4001201-0 View of Inside Appendix D. Internal Photographs E05.1123.FCC.731N / Page D2 of D9 Head Office: # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea / Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab: #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel:82-31-885-0072, Fax:82-31-885-0074 Form NO: ETL(E)004A4001201-0 Component side view of Main board Appendix D. Internal Photographs E05.1123.FCC.731N / Page D3 of D9 Head Office: # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea / Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab: #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel:82-31-885-0072, Fax:82-31-885-0074 Form NO: ETL(E)004A4001201-0 Solder side view of Main board Appendix D. Internal Photographs E05.1123.FCC.731N / Page D4 of D9 Head Office: # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea / Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab: #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel:82-31-885-0072, Fax:82-31-885-0074 Form NO: ETL(E)004A4001201-0 Inside view of front receiver Appendix D. Internal Photographs E05.1123.FCC.731N / Page D5 of D9 Head Office: # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea / Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab: #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel:82-31-885-0072, Fax:82-31-885-0074 Form NO: ETL(E)004A4001201-0 Component side view of front receiver board I Appendix D. Internal Photographs E05.1123.FCC.731N / Page D6 of D9 Head Office: # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea / Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab: #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel:82-31-885-0072, Fax:82-31-885-0074 Form NO: ETL(E)004A4001201-0 Component side view of front receiver board II Appendix D. Internal Photographs E05.1123.FCC.731N / Page D7 of D9 Head Office: # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea / Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab: #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel:82-31-885-0072, Fax:82-31-885-0074 Form NO: ETL(E)004A4001201-0 solder side view of front receiver board Appendix D. Internal Photographs E05.1123.FCC.731N / Page D8 of D9 Head Office: # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea / Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab: #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel:82-31-885-0072, Fax:82-31-885-0074 Form NO: ETL(E)004A4001201-0 Inside view of rear receiver Component side view of rear receiver board I Appendix D. Internal Photographs E05.1123.FCC.731N / Page D9 of D9 Head Office: # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea / Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab: #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel:82-31-885-0072, Fax:82-31-885-0074 Form NO: ETL(E)004A4001201-0 Component side view of rear receiver board II Solder side view of rear receiver board

Operational Description

RMR-8RD Operating Description The RMR-8RD radar detector is a dual conversion scanning super-heterodyne receiver with separate alarms for each of the radar bands, dim function, mute, city/highway select. It detects front and rear laser and radar. It contains selectable tone and a digital display of all functions. The RMR-8RD has selectable VG-2, allowing the driver to select whether he wishes to scan for the presence of detector-detectors or not. The RMR-8RD is completely VG-2/VG-3 undetectable. It is completely VG-2 undetectable. The RMR-8RD is built with high reliability surface mount construction and VCO technology for improved performance over a wide operating temperature. The RMR-8RD detects all radar and laser bands used by law enforcement: 10,475 – to – 10,575 MHz, 24,050 – to – 24,250 MHz, and 33,400 – to – 36,000 MHz, as well as 904 nanometer infrared signals. The RMR-8RD is compact, designed exclusively for automotive use and is powered by the 12- Volt electrical system in a car or truck. RMR-8RD SPECIFICATIONS Radar Receiver type : Dual conversion super-heterodyne Antenna type : Linear polarized, self-contained Detector type : Scanning frequency discriminator Frequency operation : X-band; 10.525 GHz ±50 MHz K-band; 24.150 GHz ±100 MHz Ka-band (super-wide); 34.700 GHz ±1,300 MHz Laser Receiver type : Pulsed laser signal receiver Detector type : Digital signal processor pulse width discriminator Optical sensor : Dual convex condenser lens and high speed photo diode detector, 800~1,100nanometers (nm) General Operating Temperature Range : -20° C to + 70° C Storage Temperature Range : -30° C to +100° C Power requireme nts : 12V to 15V DC, 80mA, negative ground

Test Report

www.etl.re.kr E-RAE Testing Laboratory This report only responds to the tested sample and may not be reproduced, except in full, without written approval of the ETL,Inc. Electromagnetic Emission FCC MEASUREMENT REPORT CERTIFICATION OF COMPLIANCE FCC Part 15 Certification Measurement This RADAR DETECTOR, Model RMR-8RD has been tested in accordance with the measurement procedures specified in ANSI C63.4-2001 at the ETL/EMC Test Laboratory and has been shown to be complied with the electromagnetic radiated emission limits specified in FCC Rule Part15 Subpart B: I attest to the accuracy of data. All measurement herein were performed by me or were made under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. The results of testing in this report apply to the product/system which was tested only. Other similar equipment will not necessarily produce the same results due to production tolerance and measurement uncertainties. Hyung Seok, Lee / Chief Engineer ETL Inc. #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea PRODUCT : RADAR DETECTOR MODEL/TYPE NO : RMR-8RD FCC ID : QKK-RD1 APPLICANT : Rocky Mountain Radar 6469 Doniphan Drive EL Paso TX79932 Attn.: Mike Churchman / President Manufacturer : ATTOWAVE 1005, 10F Leader’s Tower 60-15, Gasan-dong, Gumchun-gu, Seoul, 153-801, Korea FCC CLASSIFICATION : Part 15 Subpart B Unintentional Radiators Radar Detector – CRD FCC RULE PART(S) : FCC Part 15 Subpart B FCC PROCEDURE : Certification TRADE NAME : Rocky Mountain Radar TEST REPORT No. : E05.1123.FCC.731N DATES OF TEST : November 16 – 23, 2005 DATES OF ISSUE : November 23, 2005 TEST LABORATORY : ETL Inc. ( FCC Registration Number : 95422) #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea Tel : 82-31-885-0072 Fax : 82-31-885-0074 FCC TEST REPORT E05.1123.FCC.731N / Page 2 Head Office: # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea / Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab : #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel:82-31-885-0072, Fax:82-31-885-0074 Form NO: ETL(E)004A4001201-0 Table of Contents FCC Measurement Report 1. Introduction 2. Product Information 3. Description of Tests 4. Test Condition 5. Test Results 5.1 Summary of Test Results 5.2 Radiated Emissions Measurement of 11.7 - 12.2 GHz 6. Sample Calculation 7. List of test Equipment used for Measurement Appendix A. FCC ID Label and Location Appendix B. Test Setup Photographs Appendix C. External Photographs Appendix D. Internal Photographs Appendix E. Block Diagram Appendix F. User Manual Appendix G. Schematics FCC TEST REPORT E05.1123.FCC.731N / Page 3 Head Office: # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea / Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab : #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel:82-31-885-0072, Fax:82-31-885-0074 Form NO: ETL(E)004A4001201-0 Scope – Measurement and determination of electromagnetic emission(EME) of radio frequency devices including intentional radiators and/or unintentional radiators for compliance with the technical rules and regulations of the U.S Federal Communications Commission(FCC) General Information z EUT Type : RADAR DETECTOR z Model Number : RMR-8RD z FCC ID : QKK-RD1 z S/N : N/A z FCC Rule Part(s) : FCC Part 15 Subpart B z Test Procedure : ANSI C63.4-2001 z FCC Classification : Part 15 Unintentional Radiators Radar Detector (CRD) z Dates of Tests : November 16 – 23, 2005 z Place of Tests : ETL Inc. EMC Testing Lab (FCC Registration Number : 95422) 584, Sangwhal-Ri, Kanam-Myun, Yoju-Kun, Kyounggi-Do, Korea Tel : 82-31-885-0072 Fax : 82-31-885-0074 z ETest Report No. : E05.1123.FCC.731N Applicant Name : Rocky Mountain Radar Address : 6469 Doniphan Drive EL Paso TX79932 Attention : Mike Churchman / President FCC TEST REPORT E05.1123.FCC.731N / Page 4 Head Office: # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea / Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab : #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel:82-31-885-0072, Fax:82-31-885-0074 Form NO: ETL(E)004A4001201-0 1. INTRODUCTION The measurement test for radiated and conducted emission test were conducted at the open area test site of E- RAE Testing Laboratory Inc. facility located at 584, Sangwhal-ri, Ganam-myun, Youju-kun, Kyoungki-do, Korea. The site is constructed in conformance with the requirements of the ANSI C63.4-2001 and CISPR Publication 16. The ETL has site descriptions on file with the FCC for 3 and 10 meter site configurations. Detailed description of test facility was found to be in compliance with the requirements of Section 2.948 FCC Rules according to the ANSI C63.4-2001 and registered to the Federal Communications Commission(Registration Number : 95422 ). The measurement procedure described in American national standard for method of measurement of radio-noise emission from low-voltage electrical and electronic equipment in the range of 9 kHz to 40 GHz (ANSI C.63.4-2001) was used in determining radiated and conducted emissions from the Rocky Mountain Rader Model: RMR-8RD FCC TEST REPORT E05.1123.FCC.731N / Page 5 Head Office: # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea / Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab : #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel:82-31-885-0072, Fax:82-31-885-0074 Form NO: ETL(E)004A4001201-0 2. PRODUCT INFORMATION 2.1 Equipment Description The Equipment Under Test (EUT) is the Rocky Mountain Radar, RADAR DETECTOR, RMR-8RD 2.2 General Specification z Chassis Type : Plastic Cover z List of Each OSC. Or X-Tal. Freq. (>=1MHz) : X-Tal: 8.00 MHz • General Operating temperature range: -20C to +70C Storage temperature range: -30C to +100C Power requirements: 12 V to 15 V DC, 80 mA, negative ground • Laser Detector Receiver Type Pulsed lase…

Text truncated - open the document above for the full version.

Test Setup Photos

Appendix B. Test Setup Photographs E05.1123.FCC.731N / Page B1 of B1 Head Office: # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea / Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab: #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel:82-31-885-0072, Fax:82-31-885-0074 Form NO: ETL(E)004A4001201-0 Radiated Emission Test Setup

Contact Information

Applicant

Michael B Churchman(President)
[email protected]915-587-0307Fax: 915-587-6408

Test Firm

E-RAE Testing LaboratoryYo Han Park
[email protected]82-31-885-0072Fax: 82-31-885-0074

Technical Specifications

#Rule PartsFrequency RangePower Output
315B33.40 GHz - 36.00 GHz-
Confidentiality
Long Term

Other Applications from Rocky Mountain Radar

RADAR DETECTOR - FCC ID QKK-MC1 - Rocky Mountain Radar
QKK-MC1

RADAR DETECTOR

Apr 18, 2011

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
RADAR DETECTOR - FCC ID QKK-TRK - Rocky Mountain Radar
QKK-TRK

RADAR DETECTOR

Apr 18, 2011

Equipment Class

CRD - Part 15 Radar Detector
Radar Detector - FCC ID QKK-D10 - Rocky Mountain Radar
QKK-D10

Radar Detector

Nov 29, 2005

Equipment Class

CRD - Part 15 Radar Detector
Radar Laser Detector - FCC ID QKK-D04 - Rocky Mountain Radar
QKK-D04

Radar Laser Detector

Mar 29, 2004

Equipment Class

CRD - Part 15 Radar Detector
Radar Detector - FCC ID QKK-D03 - Rocky Mountain Radar
QKK-D03

Radar Detector

Dec 15, 2002

Equipment Class