Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
ST-IVB USER MANUAL ST-IVB series alarm panel Wir 1 An obvious feature of the ST-IVB is that it can be i ST-IVB 2 3 4 XXXX 0 18
~~~ ~~~ ~~~ 9 30 5 433.98MHz 433.98MHz 433.98MHz FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help.
SCS-F18: Project and Product Certification Representative Authorization Letter Page 1 of 2 Rev 3.0 775 Montague Expressway Milpitas, CA 95035 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Project and Product Certification Representative Authorization Letter Reason for Amendment (current / obsolete) Revision History Approved Date From To Initial Release (obsolete) 1.0 1.0 Nov-14-2006 Revised wording (obsolete) 1.0 2.0 Sept–25-2007 Updated company template (current) 2.0 3.0 Jan-31-2012 SCS-F18: Project and Product Certification Representative Authorization Letter Page 2 of 2 Rev 3.0 Shenzhen Meian Technology Co.,Ltd . 2013-1-7 To: SIEMIC, INC. 775 Montague Expressway, Milpitas, CA 95035 USA Dear Sir/Madam, Re: Project and Product Certification Representative Authorization Letter We, _____ Shenzhen Meian Technology Co.,Ltd .____hereby authorize SIEMIC, INC. to act as a Certification Body for certifying for the following project(s): (Alarm Control Panel,Model: ST-IVB, FCC ID: QOAST-IVB) We affirm that between SIEMIC and ___ Shenzhen Meian Technology Co.,Ltd . ___, any difference in understanding, including test plan, measurement methods, applicable standards and relevant procedures and processes have been resolved prior to commencement of testing activities. Sincerely, Client’s signature Client’s name / title : Liuwei Cai / QA Head Contact information / address : No.32,Lanshui Rd,Longdong,Longgang District,Shenzhen,China
SCS-F19: Confidentiality Request Letter Page 1 of 2 Rev 3.0 775 Montague Expressway Milpitas, CA 95035 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Confidentiality Request Letter Reason for Amendment (current / obsolete) Revision History Approved Date From To Initial Release (obsolete) 1.0 1.0 Nov-14-2006 Adding CFR 2.459 (obsolete) 1.0 2.0 August – 11 - 2008 Updated company template & Added text box (current) 2.0 3.0 Jan-31-2012 SCS-F19: Confidentiality Request Letter Page 2 of 2 Rev 3.0 Shenzhen Meian Technology Co.,Ltd . 2013-1-7 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD Subject: Permanent Confidentiality Request for FCC ID: QOAST-IVB We hereby request confidential treatment of information accompanying this application as outlined below: - Block Diagram - Schematics - Operational Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 & 0.459 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Client’s signature Client’s name / title : Liuwei Cai / QA Head Contact information / address : No.32,Lanshui Rd,Longdong,Longgang District,Shenzhen,China
APPENDIX-PHOTOGRAPHS OF EUT CONSTRUCTIONAL DETAILS Photo 1 Photo 2 Photo 3 Photo 4 Photo 5 Photo 6 Photo 7
7.5*3.2
Photo 8 Photo 9 Photo 10 Photo 11 Photo 12 Photo 13 Photo 14
FCC TEST REPORT FCC ID: QOAST-IVB Product: Alarm Control Panel Trade Name: Model Name: ST-IVB Serial Model: N/A Report No.: NTEK- 2012NT1214550F Prepared for Shenzhen Meian Technology Co.,Ltd . No.32,Lanshui Rd,Longdong,Longgang District,Shenzhen,China Prepared by Shenzhen NTEK Testing Technology Co., Ltd. 1/F, Building E, Fenda Science Park, Sanwei Community,Xixiang Street Bao’an District, Shenzhen P.R. China Tel.: +86-0755-61156588 Fax.: +86-0755-61156599 Website:www.ntek.org.cn Page 2 of 29 Report No.: NTEK- 2012NT1214550F ` TEST RESULT CERTIFICATION Applicant’s name ................. : Shenzhen Meian Technology Co.,Ltd . Address ................................. : No.32,Lanshui Rd,Longdong,Longgang District,Shenzhen,China Manufacture's Name ............ : Shenzhen Meian Technology Co.,Ltd . Address ................................. : No.32,Lanshui Rd,Longdong,Longgang District,Shenzhen,China Product description Product name ........................... : Alarm Control Panel Model and/or type reference : ST-IVB Serial Model: N/A Rating(s) ................................ : DC 3.7V Standards ............................. : FCC Part15.231 Test procedure ..............................ANSI C63.4-2003 This device described above has been tested by NTEK, and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of NTEK, this document may be altered or revised by NTEK, personal only, and shall be noted in the revision of the document. Date of Test ............................................ : Date (s) of performance of tests ............. : 11 Dec 2012 ~16 Dec 2012 Date of Issue ........................................... : 06 Jan 2013 Test Result ............................................... : Pass Testing Engineer : (Apple Huang) Technical Manager : (Tom Zhang) Authorized Signatory : (Bovey Yang) Page 3 of 29 Report No.: NTEK- 2012NT1214550F ` Table of Contents Page 1 . SUMMARY OF TEST RESULTS 4 1.1 TEST FACILITY 5 1.2 MEASUREMENT UNCERTAINTY 5 2 . GENERAL INFORMATION 6 2.1 GENERAL DESCRIPTION OF EUT 6 2.2 DESCRIPTION OF TEST MODES 7 2.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 8 2.4 DESCRIPTION OF SUPPORT UNITS(CONDUCTED MODE) 9 2.5 EQUIPMENTS LIST FOR ALL TEST ITEMS 10 3 . ANTENNA REQUIREMENT 11 3.1 STANDARD REQUIREMENT 11 3.2 EUT ANTENNA 11 3.3 CONDUCTED EMISSION MEASUREMENT 12 3.3.1 POWER LINE CONDUCTED EMISSION LIMITS 12 3.3.2 TEST PROCEDURE 13 3.3.3 DEVIATION FROM TEST STANDARD 13 3.3.4 TEST SETUP 13 3.2.5 TEST RESULT 14 3.4 RADIATED EMISSION MEASUREMENT 16 3.4.1 RADIATED EMISSION LIMITS 16 3.4.2 TEST PROCEDURE 17 3.4.3 DEVIATION FROM TEST STANDARD 17 3.4.4 TEST SETUP 17 3.4.5 TEST RESULTS (BLOW 30MHZ) 20 3.4.6 TEST RESULTS (BETWEEN 30 – 1000 MHZ) 21 4 . BANDWIDTH TEST 24 4.1 TEST PROCEDURE 24 4.2 DEVIATION FROM STANDARD 24 4.3 TEST SETUP 24 4.4 TEST RESULTS 25 5 . PERIODIC RATE EXCEEDING 26 5.1 REQUIREMENTS 26 5.2 TEST RESULTS 27 6 . EUT TEST PHOTO 28 APPENDIX-PHOTOGRAPHS OF EUT CONSTRUCTIONAL DETAILS Page 4 of 29 Report No.: NTEK- 2012NT1214550F ` 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: FCC Part15, Subpart C (15.231) Standard Section Test Item Judgment Remark 15.207 Conducted Emission Pass 15.203 Antenna Requirement Pass 15.231b Radiated Spurious Emission Pass 15.231c Occupied Bandwidth Pass 15.231a(1) Deactivation Time Pass Page 5 of 29 Report No.: NTEK- 2012NT1214550F ` 1.1 TEST FACILITY NTEK Testing Technology Co., Ltd Add. : 1/F, Building E, Fenda Science Park, Sanwei Community, Xixiang Street, Bao’an District, Shenzhen P.R. China. FCC Registration No.:238937; IC Registration No.:9270A-1 1.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U,where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of approximately 95 %。 No. Item Uncertainty 1 Conducted Emission Test ±1.38dB 2 RF power,conducted ±0.16dB 3 Spurious emissions,conducted ±0.21dB 4 All emissions,radiated(<1G) ±4.68dB 5 All emissions,radiated(>1G) ±4.89dB 6 Temperature ±0.5°C 7 Humidity ±2% Page 6 of 29 Report No.: NTEK- 2012NT1214550F ` 2. GENERAL INFORMATION 2.1 GENERAL DESCRIPTION OF EUT Equipment Alarm Control Panel Trade Name Model Name ST-IVB Serial Model N/A Model Difference N/A Product Description The EUT is a Alarm Control Panel Product Type Remote Control Operation Frequency: 433.98MHz Modulation Type: FSK Number Of Channel 1CH. Antenna Designation: Build-in ANT Antenna Gain(Peak) 0.8dBi Output Power: 72.64 dBuV/m @3m(AV Max.) More details of EUT technical specification, please refer to the User's Manual. Channel List N/A Adapter Model:SAW30-150-2000 INPUT:100-240V~, 50/60Hz,0.8A OUTPUT:15V,2000mA Battery DC 3.7V Note: 1. For a more detailed features description, please refer to the manufacturer’s specifications or the User's Manual. 2. Table for Filed Antenna Ant . Brand Model Name Antenna Type Connector Gain (dBi) NOTE 1 N/A N/A Build-in ANT N/A 0.8 Antenna Operation principle: When its tamper switch damaged. It can find alarm situation through the wired areas of the wired connections. Or it receives the alarm information from the detection terminals through the wireless module receiver. Through the wireless module to send out the data, and to make the linked siren to give an alarm Page 7 of 29 Report No.: NTEK- 2012NT1214550F ` 2.2 DESCRIPTION OF TEST MODES To investigate the maximum EMI emission characteristics generates from EUT, the test system was pre-scanning tested base on the consideration of following EUT operation mode or test configuration mode which possible have effect on EMI emission level. Each of these EUT operation mode(s) or test configuration mode(s) mentioned above was evaluated respectively. Pretest Mode Description Mode 1 TX For Condu…
Text truncated - open the document above for the full version.
Page 26 of 27 Report No.: PTS20121009679F ` 6. EUT TEST PHOTO Radiated Measurement Photos Page 27 of 27 Report No.: PTS20121009679F ` Conducted Measurement Photos
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 433.98 MHz - 433.98 MHz | - |

ALARM CONTROL PANEL
Equipment Class
PCB - PCS Licensed Transmitter
Wireless PIR Detector
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Alarm control panel
Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
Wireless PIR detector
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Wireless siren
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter