Copyright 2007 MEI Page 1 of 6 Installation Guide & Specifications 20105-00289XXXX-IG G1 E E a a s s i i t t r r a a x x S S C C R R e e a a d d e e r r I I n n s s t t a a l l l l a a t t i i o o n n G G u u i i d d e e & & S S p p e e c c i i f f i i c c a a t t i i o o n n COPYRIGHT © 2007 MEI The information contained here-in is the property of MEI and is not to be disclosed or used without the prior written permission of MEI. This copyright extends to all the media in which this information may be preserved including magnetic storage, punched card, paper tape, computer printout or visual display. Copyright 2007 MEI Page 2 of 6 Installation Guide & Specifications 20105-00289XXXX-IG G1 Document Change History Revision Date Change Description G1 September 6, 2007 Initial Release Published by: ©, mei 2007 All rights reserved. mei ® logo is a registered trademark. Except as permitted under the relevant local legislation, no part of this publication may be copied, transmitted, transcribed or distributed in any form or by any means, or stored in a database or retrieval system, or translated into any language (natural or computer) without the prior written permission of MEI. MEI reserves the right to change the market requirement specifications at any time. While every effort has been made to ensure that the information in this publication is accurate, MEI disclaims any liability for any direct or indirect losses (howsoever caused) arising out of use or reliance on this information. This document does not necessarily imply product availability. Copyright 2007 MEI Page 3 of 6 Installation Guide & Specifications 20105-00289XXXX-IG G1 MEI EASITRAX SC READER INSTALLATION GUIDE & SPECIFICATION 20105-00289DCBA-IG Rev G1 Documentation: The document below describes the installation and setup for the Easitrax SC Reader base which is used with the MEI Easitrax SC Cashbox asset tracking system. The Easitrax SC Reader base is typically used in a casino soft drop accounting area in concert with a client personal computer running software to interrogate the reader base for cashbox cassettes. This part is regulated under FCC ID: QP8EASITRAXRB CAUTION: Changes or modifications not expressly approved by the party responsible for compliance for the EASITRAX SC READER base could void the user’s authority to operate this equipment. NOTE: This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, (2) This device must accept any interference received, including interference that may cause undesired operation. ----------------------------------------------------------------------------------------------------------- Copyright 2007 MEI Page 4 of 6 Installation Guide & Specifications 20105-00289XXXX-IG G1 Materials Included with the Reader base: 1 EASITRAX SC READER base with attached cable 2 INSTALLATION GUIDE Setup: Place Reader base in a secure area on table within 1 meter of personal computer. Ensure that the intended client device to be used with the Reader base has had a version of the MEI reader software installed. This software allows the Reader base to be recognized as a new USB device when the installation is completed and is available from either MEI or from your currency counting equipment provider. Copyright 2007 MEI Page 5 of 6 Installation Guide & Specifications 20105-00289XXXX-IG G1 Ensure that computer is fully powered off when first installing this equipment. If the equipment is not powered off, do so now. Route the cable attached to the reader base to the rear of the personal computer such that you can attach the opposite end of the cable to the USB port on the personal computer. Note: If you are using more than one reader base, each base must be installed to a separate USB connector. Attach the cable as shown below to the personal computer such that the USB connector is fully attached and latched if appropriate. Note: The next generation of the EASITRAX SC READER base will be compatible with USB connections and will not require keyboard connector pass through to power the device. Once the reader base cable is fully installed, you may power on the personal computer and allow the computer to boot up. The blue front panel LED on the Easitrax SC Reader base should light and go through a brief power on test. Following this test only the blue power on indicator LED should be illuminated. The Easitrax SC Reader base is now ready for use with the back room accounting software loaded on your PC by your currency sorter/counter vendor. That software should allow you to read full cassettes and record identifying information prior to removal of the cashbox from the reader base. You may wish to test the system functionality by placing an unread cashbox cassette onto the base following the instructions imprinted on the reader base. Ensure that the cashbox handle is facing the front of the base and that the top side of the cashbox cassette is placed nearest to the reader base. Using the software, you may select from several different functions to verify that the reader base will read both full and empty cashboxes. Once you have verified the performance of the system, you are ready to begin using your reader base in normal operation. Copyright 2007 MEI Page 6 of 6 Installation Guide & Specifications 20105-00289XXXX-IG G1 Troubleshooting the reader base: In the event that the reader base does not function as expected, please ensure that the cashbox cassette is properly placed on the reader base, ensure that the usb cable is properly plugged into a USB port on the rear of the client PC. Power down and repower the client PC and ensure that the reader base is recognized and that the power on indicator blue led comes on. If you are still having problems, please contact MEI Customer Technical support at 1-800-523-5146 or visit www.meigroup.com
Date: 6 September 2007 To: American Telecommunications Certified Body 6731 Whittier Avnue Suite C110 McLean, Virginia 22101 Subject: Certification Application - Request for Confidentiality to CFR 47, 0.457 & 0.459 FCC ID: QP8EASITRAXRB Please be advised that the following information is requested to be held confidential on behalf of MEI. • Schematics • Block Diagram • Theory of Operation The application contains technical information which MEI deems to be trade secrets and proprietary. If made public, the information might be used to the disadvantage of the applicant in the market place. Thank you for your attention in this mater. Robert M. Carney Product Safety & Compliance Manager Tel: 610-430-2697 Fax: 601-430-2795 e-mail: [email protected] 1301 Wilson Drive, West Chester, Pennsylvania 19380-5963 Tel: (610) 430-2700 · Fax: (610) 430-2694 www.meigroup.com
Date: 23 January 2007 To: American Telecommunications Certified Body 6731 Whittier Avnue Suite C110 McLean, Virginia 22101 From: MEI 1301 Wilson Drive West Chester, Pa. 19380 Subject: Letter of Agency To Whom it may concern, Please be advised that MEI authorizes Washington Laboratories, Ltd. to act on our behalf, until otherwise notified, for applications submitted to American Telecommunications Certified Body, Inc. (ATCB) We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 53011 of the Anti-Drug Abuse ACT of 1988, U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002(b), to the application is subject to denial of federal benefits, that includes FCC benefits. Thanks you for your attention to this matter. Robert M.Carney Product Compliance Manager Tel: 610-430-2697 Fax: 601-430-2795 e-mail: [email protected] 1301 Wilson Drive, West Chester, Pennsylvania 19380-5963 Tel: (610) 430-2500 · Fax: (610) 430-2694 www.meigroup.com
Response to ATCB Comments FCC ID: QP8EASITRAXRB 1 Washington Laboratories, Ltd. 7560 LINDBERGH DRIVE GAITHERSBURG, MD 20879 (301) 417 – 0220 FAX # (301) 417 - 9069 October 1, 2007 Mr. Dennis Ward American Telecommunications Certification Body Inc. 6731 Whittier Ave McLean, VA 22101 RE: Comments of September 27, 2007 APPLICATION: QP8EASITRAX Mars Electronics, Inc. Dear Mr. W a r d: Below are the comments that you have provided regarding the application for certification referenced above. Our responses to those comments are in bold italic. Many responses refer you to additional exhibit(s) which has been uploaded to the application folder at the ATCB website. Thank you for your attention. Please feel free to contact us for any additional information that you may require. Regards, Steven D. Koster EMC Operations Manager Brian J. Dettling Documentation Specialist WLL Project: 9915 1) Please note that measurements of frequencies below 30MHz must be done using a loop antenna. Please note that while section 4.2.1 states a loop antenna was used, the listing of equipment used on page 10 of the report does not appear to contain any information on the magnetic loop antenna. Please correct and provide calibration information etc for the loop antenna. R. The loop antenna information has been added to the equipment list. See “EASITRAXRB Test Report revised”. 2) Please note that the block diagram needs to conform to 2.1033 requirements whereby it contains: “the frequency of all oscillators in the device. The signal path and frequency shall be indicated at each block. The tuning range(s) and intermediate frequency(ies) shall be indicated at each block.” Please note Response to ATCB Comments FCC ID: QP8EASITRAXRB 2 that the block diagram provided appears to show only the antenna and not the transmitter. Please explain and please provide a block diagram in accordance with 2.1033 of the FCC rules. R. Please see “EASITRAXRB Block Diagram revised”. 3) FYI – please note that recently, during application audits, the FCC has requested that the receive antenna be shown in the test setup photos. Please consider this in future applications. R. Noted, however at Washington Laboratories we have weather protected OATS that do not allow us to show the receive antenna in the setup photos.
External Photos ©2007 Washington Laboratories, Ltd FCC ID: QP8EASITRAXRB External Photos ©2007 Washington Laboratories, Ltd FCC ID: QP8EASITRAXRB External Photos ©2007 Washington Laboratories, Ltd FCC ID: QP8EASITRAXRB
Label Location ©2007 Washington Laboratories, Ltd FCC ID: QP8EASITRAXRB
Internal Photos ©2007 Washington Laboratories, Ltd FCC ID: QP8EASITRAXRB Internal Photos ©2007 Washington Laboratories, Ltd FCC ID: QP8EASITRAXRB Internal Photos ©2007 Washington Laboratories, Ltd FCC ID: QP8EASITRAXRB
FCC Certification Test Report for the MEI Cashflow RFID Reader Base FCC ID: QP8EASITRAXRB WLL JOB# 9915 September 21, 2007 Prepared for: MEI 1301 Wilson Drive West Chester, PA 19380 Prepared By: Washington Laboratories, Ltd. 7560 Lindbergh Drive Gaithersburg, Maryland 20879 MEI easitrax™ FCC Certification Test Report September 2007 FCC Certification Test Report For the MEI Cashflow RFID Reader Base FCC ID: QP8EASITRAXRB September 21, 2007 WLL JOB# 9915 Prepared by: ___________________________ John P. Repella EMC Engineer Reviewed by: ____________________________ Steven D. Koster EMC Operations Manager MEI easitrax™ FCC Certification Test Report September 2007 WLL Report #9554-01 - ii - © 2007 Washington Laboratories, Ltd. Abstract This report has been prepared on behalf of MEI to support the attached Application for Equipment Authorization. The test report and application are submitted for an Intentional Radiator under Part 15.225 of the FCC Rules and Regulations. This Certification Test Report documents the test configuration and test results for a MEI Cashflow RFID Reader Base with easitrax™. Testing was performed on an Open Area Test Site (OATS) of Washington Laboratories, Ltd, 7560 Lindbergh Drive, Gaithersburg, MD 20879. Site description and site attenuation data have been placed on file with the FCC's Sampling and Measurements Branch at the FCC laboratory in Columbia, MD. Washington Laboratories, Ltd. has been accepted by the FCC and approved by NIST NVLAP (NVLAP Lab Code: 200066-0) as an independent FCC test laboratory. The MEI Cashflow RFID Reader Base with easitrax™ complies with the limits for an Intentional Radiator device under FCC Part 15.225. MEI easitrax™ FCC Certification Test Report September 2007 WLL Report #9554-01 - iii - © 2007 Washington Laboratories, Ltd. Table of Contents Abstract ........................................................................................................................................... ii 1 Introduction ..........................................................................................................................1 1.1 Compliance Statement .....................................................................................................1 1.2 Test Scope ........................................................................................................................1 1.3 Contract Information ........................................................................................................1 1.4 Test Dates ........................................................................................................................1 1.5 Test and Support Personnel .............................................................................................1 1.6 Abbreviations ...................................................................................................................2 2 Equipment Under Test .........................................................................................................3 2.1 EUT Identification & Description ...................................................................................3 2.2 Test Configuration ...........................................................................................................3 2.3 Testing Algorithm ............................................................................................................4 2.4 Test Location ...................................................................................................................4 2.5 Measurements ..................................................................................................................4 2.5.1 References ....................................................................................................................4 2.6 Measurement Uncertainty ................................................................................................5 3 Test Equipment ....................................................................................................................6 4 Test Results ..........................................................................................................................7 4.1 Occupied Bandwidth ........................................................................................................7 4.2 Radiated Spurious Emissions: §15.225, §15.209 ............................................................9 4.2.1 Test Procedure ...........................................................................................................9 4.2.2 Test Results ................................................................................................................10 4.3 Frequency Stability: (FCC Part §2.1055) ......................................................................12 4.3.1 Test Procedure ...........................................................................................................12 4.3.2 Test Results ................................................................................................................12 4.4 Conducted Emissions (AC Power Line) ........................................................................14 List of Tables Table 1. Device Summary ............................................................................................................... 3 Table 2: Test Equipment List .......................................................................................................... 6 Table 3: Occupied Bandwidth Results ............................................................................................ 8 Table 4: Radiated Spurious Emissions Limits ................................................................................ 9 Table 5: Radiated Emission Test Data, Fundamental Frequency ................................................. 10 Table 6: Radiated Emission Test Data ....................................................................…
Text truncated - open the document above for the full version.
Test Setup Photos ©2007 Washington Laboratories, Ltd Test Setup Photos ©2007 Washington Laboratories, Ltd Test Setup Photos ©2007 Washington Laboratories, Ltd Test Setup Photos ©2007 Washington Laboratories, Ltd Test Setup Photos ©2007 Washington Laboratories, Ltd Test Setup Photos ©2007 Washington Laboratories, Ltd
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 13.56 MHz - 13.56 MHz | - |

ALIO Note is a cashless and telemetry system from CPI
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
SMART7 Card Reader Bezel
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
CORA modular data port
Equipment Class
PCB - PCS Licensed Transmitter
RFID system
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
5 in 1 Credit Card Bezel
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter