FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Zentan Technology Co., Ltd./
  3. QSW2SCS

QSW2SCSSYSTEM 122

Zentan Technology Co., Ltd.
SYSTEM 122 - FCC ID QSW2SCS - Zentan Technology Co., Ltd.
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Jul 11, 2006
Application Purpose
Original Equipment
Date of Application
Jul 11, 2006
Equipment Note
SYSTEM 122
Frequency Range
0.12700000 - 0.12700000
Company
Zentan Technology Co., Ltd.
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

FCC ID: QSW2SCS FCC Compliance and Advisory Statement This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) this device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, according to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try correct the interference by one or more of the following measures: 1.Reorient the receiving antenna. 2.Increase the separation between the equipment and receiver. 3.Connect the equipment into and outlet on a circuit different from that to which the receiver is connected. 4.Consult the dealer or an experienced radio/TV technician for help. Any special accessories needed for compliance must be specified in the instruction manual. Warning: A shielded-type power cord is required in order to meet FCC emission limits and also to prevent interference to the nearby radio and television reception. It is essential that only the supplied power cord be used. Use only shielded cables to connect I/O devices to this equipment. CAUSION: Any changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment. 2

Cover Letter(s)

Rev. 1/1/03 Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID: QSW2SCS Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: 1. Schematics 2. Block Diagram 3. Operational Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, (Name / Title )

External Photos

Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. Photo Page: 1 of 10 PART I : TRANSMITTER PART PHOTOS OF EUT Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. Photo Page: 3 of 10 PHOTOS OF EUT-CASE

ID Label/Location Info

Sample of FCC ID Label FCC ID: QSW2SCS The device is so small that the Two-Part warning statement does not have to go on the device. It will be really hard to read. We remove the Two-Part statement from the device since we already have it in the manual. Sample of FCC DoC Label The device is so small that the Two-Part warning statement does not have to go on the device. It will be really hard to read. We remove the Two-Part statement from the device since we already have it in the manual.

Internal Photos

Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. Photo Page: 2 of 10 PHOTOS OF EUT-TOP INSIDE Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. Photo Page: 4 of 10 PHOTOS OF EUT-PCB

Test Report

Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan TEST REPORT Reference No.: A06032005 Report No.: FCCA06032005 Page: 2 of 17 Date: Jun. 19, 2006 FCC ID: QSW2SCS Table of Contents 1. DOCUMENT POLICY AND TEST STATEMENT............................................................................. 3 1.1 DOCUMENT POLICY .........................................................................................3 1.2 TEST STATEMENT.............................................................................................3 2. DESCRIPTION OF EUT AND TEST MODE ................................................................................... 4 2.1 GENERAL DESCRIPTION OF EUT....................................................................4 2.2 DESCRIPTION OF EUT INTERNAL DEVICE.....................................................4 2.3 DESCRIPTION OF TEST MODE ........................................................................4 2.4 DESCRIPTION OF SUPPORT UNIT ..................................................................5 3. DESCRIPTION OF APPLIED STANDARDS................................................................................... 5 4. RADIATED EMISSION TEST.......................................................................................................... 6 4.1 RADIATED EMISSION LIMIT..............................................................................6 4.2 TEST EQUIPMENT.............................................................................................7 4.3 TEST SET-UP .....................................................................................................8 4.4 TEST PROCEDURE ...........................................................................................9 4.5 EUT OPERATING CONDITION ..........................................................................9 4.6 RADIATED EMISSION TEST RESULT .............................................................10 6 TIME DOMAIN AND DUTY CYCLE TEST....................................................................................... 12 6.1 TEST EQUIPMENT...........................................................................................12 6.2 TEST SET-UP ...................................................................................................12 6.3 TEST PROCEDURE .........................................................................................12 6.4 EUT OPERATING CONDITION ........................................................................12 6.5 TIME DOMAIN AND DUTY CYCLE TEST RESULT .........................................13 7. PHOTOS OF TESTING................................................................................................................. 15 7 TERMS OF ABRIVATION............................................................................................................... 17 Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan TEST REPORT Reference No.: A06032005 Report No.: FCCA06032005 Page: 3 of 17 Date: Jun. 19, 2006 FCC ID: QSW2SCS 1. DOCUMENT POLICY AND TEST STATEMENT 1.1 DOCUMENT POLICY - The report shall not be reproduced except in full, without the written approval of SRT Lab, Inc. - The report must not be used by the applicant to claim that the product is endorsed by NVLAP. - The NVLAP logo applies only to the applicable standards specified in this report. 1.2 TEST STATEMENT - The test results in the report apply only to the unit tested by SRT Lab. - There was no deviation from the requirements of test standards during the test. - The heartbeat simulator (see the test photo) was produced signal to EUT during the test. - DC power source, 3V from Lithium battery, was used during the test. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan TEST REPORT Reference No.: A06032005 Report No.: FCCA06032005 Page: 4 of 17 Date: Jun. 19, 2006 FCC ID: QSW2SCS 2. DESCRIPTION OF EUT AND TEST MODE 2.1 GENERAL DESCRIPTION OF EUT PRODUCT SYSTEM 122 MODEL NO. ZT2SC, ZT2SCS POWER SUPPLY DC 3V, 0.5mA CABLE N/A I/O PORT N/A FREQUENCY BAND 127KHz ± 10% CARRIER FREQUENCY 127KHz±10% NUMBER OF CHANNEL 1 CHANNEL SPACING 0 MODULATION TYPE PULSE DUTY CYCLE 0.5-5% MODE OF OPERATION SIMPLEX BIT RATE OF TRANSMISSION 1000 BIT/SEC ANTENNA TYPE Coils would be on ferrite cores and soldered to transmitter NOTE: ZT2SC and ZT2SCS are identical in all aspects except for enclosure. The EUT is the transmitter part. For more detailed features, please refer to the User’s Manual of EUT. 2.2 DESCRIPTION OF EUT INTERNAL DEVICE DEVICE BRAND / MAKER MODEL # FCC ID/DOC REMARK N/A 2.3 DESCRIPTION OF TEST MODE N/A (It is only applicable to more than one test mode.) Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan TEST REPORT Reference No.: A06032005 Report No.: FCCA06032005 Page: 5 of 17 Date: Jun. 19, 2006 FCC ID: QSW2SCS 2.4 DESCRIPTION OF SUPPORT UNIT The EUT was configured by the requirement of ANSI C63.4. All interface ports were connected to the appropriate support units via specific cables. The support units and cables are listed below. NO DEVICE BRAND MODEL #FCC ID / DOC CABLE 1 HEART RATEMONITOR ZENTAN GT3 N/A N/A NOTE : For the actual test configuration, please refer to the photos of testing. 3. DESCRIPTION OF APPLIED STANDARDS The EUT is a kind of radio product and according to the specifications provided by the applicant, it must comply with the requirements of the following standards: 47 CFR Part 15, Subpart C ANSI C63.4: 2003 All tests have been performed and recorded as per the above standards. Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan TEST REPORT Reference No.: A06032005 Report No.: FCCA06032005 Page: 6 of 17 Date: Jun. 19, 2006 FCC ID: QSW2SCS 4. RADIATED EMISSION TEST 4.1 RADIATED EMISSION LIM…

Text truncated - open the document above for the full version.

Test Setup Photos

Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan TEST REPORT Reference No.: A06032005 Report No.: FCCA06032005 Page: 15 of 17 Date: Jun. 19, 2006 FCC ID: QSW2SCS 7. PHOTOS OF TESTING - Raditated test -Below 30MHz (Loop Antenna) Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan TEST REPORT Reference No.: A06032005 Report No.: FCCA06032005 Page: 16 of 17 Date: Jun. 19, 2006 FCC ID: QSW2SCS -Raditated test-30~1000MHz (Bi-log Antenna)

Contact Information

Applicant

Winner Chen(General Manager)
[email protected]886-6-7232226Fax: 886-6-7231289

Test Firm

Spectrum Research & Testing Laboratory, Inc.Cheng Ho
[email protected]886-3-4987684Fax: 886-3-4986528

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.127 MHz - 0.127 MHz-
Confidentiality
Long Term

Other Applications from Zentan Technology Co., Ltd.

Two Channel EMG Monitor - FCC ID QSWZE1 - Zentan Technology Co., Ltd.
QSWZE1

Two Channel EMG Monitor

Apr 14, 2021

Equipment Class

DTS - Digital Transmission System
Wireless Physical Fitness Monitor/Wireless Heart Rate Monitor - FCC ID QSWST2GEN1 - Zentan Technology Co., Ltd.
QSWST2GEN1

Wireless Physical Fitness Monitor/Wireless Heart Rate Monitor

Jan 12, 2021

Equipment Class

DTS - Digital Transmission System
SPEED (ZAS1B)/CADENCE (ZAS1B-C) - FCC ID QSWBSPDCS - Zentan Technology Co., Ltd.
QSWBSPDCS

SPEED (ZAS1B)/CADENCE (ZAS1B-C)

Sep 29, 2013

Equipment Class

DTS - Digital Transmission System
TP3 SMART HEART RATE TRANSMITTER (ZT26B) - FCC ID QSWBHRCS1 - Zentan Technology Co., Ltd.
QSWBHRCS1

TP3 SMART HEART RATE TRANSMITTER (ZT26B)

Feb 07, 2013

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Performance console and control box - FCC ID QSWAPWDBB - Zentan Technology Co., Ltd.
QSWAPWDBB

Performance console and control box

Jun 18, 2012

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter