QTUSL1526energy saving lamp

Everlite Electric Industries Corp.
energy saving lamp - FCC ID QTUSL1526 - Everlite Electric Industries Corp.
Click to zoom

Application Details

Equipment Class
8CC - Part 18 Consumer Device
Date of Grant
Apr 15, 2003
Application Purpose
Original Equipment
Date of Application
Apr 15, 2003
Equipment Note
energy saving lamp
Frequency Range
0.04000000 - 0.04500000
Company
Everlite Electric Industries Corp.
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Schematics

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Users Manual

External Photos

External Photos FIGURE 1 Energy Saving Lamp General Appearance CFLE 15 S/L/827/840/865 CFLE 18 S/L/827/840/865CFLE 20 S/L/827/840/865 FIGURE 2 Energy Saving Lamp General Appearance CFLE 23 S/L/827/840/865 CFLE 26 S/L/827/840/865

ID Label/Location Info

ID Label /Location Info label sample LABEL EVERLITE 15W 120V / 60Hz /0.26A CFLE 15 S/L/827/840/865 FCC ID:QTUSL1526 UL:***** EVERLITE 18W 120V / 60Hz /0.30A CFLE 18 S/L/827/840/865 FCC ID:QTUSL1526 UL:***** EVERLITE 20W 120V / 60Hz /0.34A CFLE 20 S/L/827/840/865 FCC ID:QTUSL1526 UL:***** EVERLITE 23W 120V / 60Hz /0.38A CFLE 23 S/L/827/840/865 FCC ID:QTUSL1526 UL:***** EVERLITE 26W 120V / 60Hz /0.40A CFLE 26 S/L/827/840/865 FCC ID:QTUSL1526 UL:*****

ID Label/Location Info

ID Label/Location Info label location Label Location Information The location of all the labels are on the button enclosures of the products. Refer to the below arrow.

Internal Photos

Internal Photos FIGURE 1 Energy Saving Lamp Cover Removed CFLE 15 S/L/827/840/865 CFLE 18 S/L/827/840/865 CFLE 20 S/L/827/840/865 FIGURE 2 Energy Saving Lamp Cover Removed CFLE 23 S/L/827/840/865 CFLE 26 S/L/827/840/865 FIGURE 3 Energy Saving Lamp Main Board (Component CFLE 15 S/L/827/840/865 Side) FIGURE 4 Energy Saving Lamp Main Board (Soldered Side) FIGURE 5 Energy Saving Lamp Main Board (Component Side) CFLE 15 S/L/827/840/865 FIGURE 6 Energy Saving Lamp Main Board (Soldered Side) FIGURE 7 Energy Saving Lamp Main Board (Component Side) CFLE 18 S/L/827/840/865 CFLE 18 S/L/827/840/865 FIGURE 8 Energy Saving Lamp Main Board (Soldered Side) FIGURE 9 Energy Saving Lamp Main Board (Component Side) CFLE 20 S/L/827/840/865 CFLE 20 S/L/827/840/865 FIGURE 10 Energy Saving Lamp Main Board (Soldered Side) FIGURE 11 Energy Saving Lamp Main Board (Component Side) CFLE 23 S/L/827/840/865 CFLE 23 S/L/827/840/865 FIGURE 12 Energy Saving Lamp Main Board (Soldered Side) CFLE 26 S/L/827/840/865 CFLE 26 S/L/827/840/865

Schematics

Circuit Diagram

Test Report

Everlite Electric Industries Corp. FCC ID:QTUSL1526 Page 1 of 1 SHENZHEN EMTEK CO., LTD. Report No. AT03042 Application for FCC Certificate On Behalf of Everlite Electric Industries Corp. Energy Saving Lamp Model No.: CFLE 15 S/L/827/840/865 CFLE 18 S/L/827/840/865 CFLE 20 S/L/827/840/865 CFLE 23 S/L/827/840/865 CFLE 26 S/L/827/840/865 FCC ID :QTUSL1526 Prepared for : Everlite Electric Industries Corp. Address : 200. Kuang-Fu Rd., Section 2 Hsinchu, Taiwan Prepared by : SHENZHEN EMTEK CO., LTD. Address : Bldg 69, Majialong, Taipinyang Industry Zone, Nanshan District, Shenzen, Guangdong, China Tel: (0755) 26952508 Fax: (0755) 26954282 Report Number : AT03042 Date of Test : Feb 26~28, 2003 Date of Report : Feb 28, 2003 Everlite Electric Industries Corp. FCC ID:QTUSL1526 Page 2 of 2 SHENZHEN EMTEK CO., LTD. Report No. AT03042 TABLE OF CONTENTS Description Page 1. GENERAL INFORMATION......................................................................................................4 1.1. Description of Device (EUT)...............................................................................................................4 1.2. Test Facility........................................................................................................................................4 1.3. Measurement Uncertainty....................................................................................................................4 2. POWER LINE CONDUCTED MEASUREMENT....................................................................5 2.1. Test Equipment...................................................................................................................................5 2.2. Block Diagram of Test Setup...............................................................................................................5 2.3. Power Line Conducted Emission Measurement Limits..........................................................................5 2.4. Configuration of EUT on Measurement...............................................................................................6 2.5. Operating Condition of EUT................................................................................................................6 2.6. Test Procedure....................................................................................................................................6 2.7. Power Line Conducted Emission Measurement Results........................................................................7 2.8. Plot of Conducted Emissions Test Data.............................................................................................12 3. RADIATED EMISSION MEASUREMENT............................................................................13 3.1. Test Equipment.................................................................................................................................13 3.2. Block Diagram of Test Setup.............................................................................................................14 3.3. Radiated Emission Limit....................................................................................................................14 3.4. EUT Configuration on Measurement.................................................................................................15 3.5. Operating Condition of EUT..............................................................................................................15 3.6. Test Procedure..................................................................................................................................15 3.7. Radiated Emission Noise Measurement Result...................................................................................16 APPENDIX A –PLOT OF CONDUCTED EMISSIONS TEST DATA...........................................21 Everlite Electric Industries Corp. FCC ID:QTUSL1526 Page 3 of 3 SHENZHEN EMTEK CO., LTD. Report No. AT03042 Everlite Electric Industries Corp. FCC ID:QTUSL1526 Page 4 of 4 SHENZHEN EMTEK CO., LTD. Report No. AT03042 1. GENERAL INFORMATION 1.1. Description of Device (EUT) 1.2. Test Facility Site Description EMC Lab. : Accredited by FCC, December 09,2002 The Certificate Registration Number. is 709623. Name of Firm : SHENZHEN EMTEK CO., LTD Site Location : Bldg 69, Majialong, Taipinyang Industry Zone, Nanshan District, Shenzen, Guangdong, China 1.3. Measurement Uncertainty Radiation Uncertainty : Ur = °” 4.26dB Conduction Uncertainty : Uc = °” 2.66dB EUT : Energy Saving Lamp Model Number : CFLE 15 S/L/827/840/865, CFLE 18 S/L/827/840/865, CFLE 20 S/L/827/840/865, CFLE 23 S/L/827/840/865, CFLE 26 S/L/827/840/865 (Note: All samples have been tested, the test results were reported.) Applicant : Everlite Electric Industries Corp. Address : 200. Kuang-Fu Rd., Section 2 Hsinchu, Taiwan Manufacturer : Everlite (H.K) CO. Address : Sichun Administrative Dist, Tangxia Town, Dongguan, Guangdong, China. Date of Test : Feb 26~28,2003 Everlite Electric Industries Corp. FCC ID:QTUSL1526 Page 5 of 5 SHENZHEN EMTEK CO., LTD. Report No. AT03042 2. POWER LINE CONDUCTED MEASUREMENT 2.1. Test Equipment The following test equipments are used during the power line conducted measurement: Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval 1. Test Receiver Rohde & Schwarz ESCS30 828985/018 Jun 01, 2002 1 Year 2. L.I.S.N Rohde & Schwarz ESH2-Z5 834549/005 Jun 01, 2002 1 Year 3. 50Coaxial Switch Anritsu MP59B M20531 N/A N/A 4. Pulse Limiter Rohde & Schwarz ESH3-Z2 100006 Jun 01, 2002 1 Year 5. Voltage Probe Rohde & Schwarz TK9416 N/A Jun 01, 2002 1 Year 2.2. Block Diagram of Test Setup 2.2.1. Block diagram of connection between the EUT and simulators (EUT: Energy Saving Lamp) 2.3. Power Line Conducted Emission Measurement Limits Maximum RF Line Voltage Frequency MHz μV dB(μV) 0.45 ~ 2.51 250 48 2.51~3.00 3000 69.5 3.00~30.00 250 48 Remarks: RF Line Voltage (dB(μV)) = 20 log RF Line …

Text truncated - open the document above for the full version.

Test Setup Photos

Test Setup Photos Test Setup Photos All series of products are setup in the same. Refer to the following photos for conducted and radiated emission. Conducted Emission Test Front view Side view Radiated Emission Test Horizontal Ve r t i c a l

Contact Information

Applicant

Pauline Chen(Engineer)
[email protected]886-3-5713155Fax: 886-3-5711629

Technical Specifications

#Rule PartsFrequency RangePower Output
1180.04 MHz - 0.045 MHz-

Other Applications from Everlite Electric Industries Corp.

ENERGY SAVING LAMP - FCC ID QTUCFLE1526 - Everlite Electric Industries Corp.
QTUCFLE1526

ENERGY SAVING LAMP

May 15, 2006

Equipment Class

8CC - Part 18 Consumer Device
ENERGY SAVING LAMP - FCC ID QTUCFLE1523 - Everlite Electric Industries Corp.
QTUCFLE1523

ENERGY SAVING LAMP

May 15, 2006

Equipment Class

8CC - Part 18 Consumer Device
Energy Saving Lamp - FCC ID QTUTA1318 - Everlite Electric Industries Corp.
QTUTA1318

Energy Saving Lamp

Apr 16, 2003

Equipment Class

8CC - Part 18 Consumer Device
Energy Saving Lamp - FCC ID QTUTL1326 - Everlite Electric Industries Corp.
QTUTL1326

Energy Saving Lamp

Apr 15, 2003

Equipment Class

8CC - Part 18 Consumer Device
Energy Saving Lamp - FCC ID QTUTX0515 - Everlite Electric Industries Corp.
QTUTX0515

Energy Saving Lamp

Apr 15, 2003

Equipment Class