Fall Detection Unit USER MANUAL February 2005 HomeFree Systems Ltd Pendant (Panic Button) User Manual 1 Table of Contents 1. Fall Detection Unit Operational Instructions........................3 1.1. Connecting the Fall Detection Unit...........................................4 1.2. Activating / Deactivating the Fall Detection Unit.....................4 1.2.1. Setting the Fall Alarm Volume..................................................5 1.2.2. Setting the Fall Alarm Delay.....................................................5 1.3. Initiating a Fall Alarm................................................................5 1.3.1. Bypassing the Fall Alarm..........................................................6 2. FCC Notices..............................................................................7 HomeFree Systems Ltd Pendant (Panic Button) User Manual 2 HomeFree Systems Ltd Pendant (Panic Button) User Manual 1. Fall Detection Unit Operational Instructions The HomeFree system was designed to monitor special needs and Dementia individuals in the care center environment. The Fall Detection Unit is one of the many unique elements of this system. The Fall Detection Unit is a small, battery operated device, connected to a chair or bed monitoring mat, that can be used to notify care center staff members whenever the resident gets out of the chair or bed. The Fall Detection Unit is positioned on the chair or at the bedside. The Fall Detection Unit is not for use outside the monitored area. Mat Connection Jack Alarm Reset / Bypass Button Alarm Volume Panel LED Indicator Alert Delay Panel 3 HomeFree Systems Ltd Pendant (Panic Button) User Manual 4 1.1. Connecting the Fall Detection Unit Plug the chair / bed mat into the mat connection jack, ensuring that the cable between the mat and the Fall Detection Unit can move freely and is clear of any moving parts. Place the chair / bed mat into its required position (refer to the placement instructions for the appropriate chair / bed mat). Place the Fall Detection Unit on the chair or at the bedside. 1.2. Activating / Deactivating the Fall Detection Unit Insert the batteries (battery type) in order to activate the Fall Detection Unit. Loosen the screw located on the back lower panel of the Fall Detection Unit and gently remove the cover. Insert the required batteries into the battery holder. The LED indicator illuminates and a single beeping sound is heard. Gently replace the cover and tighten the screw holding the back lower panel. ONCE IN ACTIVE MODE, THE FALL ALERT UNIT AUTOMATICALLY SENDS A TRANSMISSION (EVERY 18-22 SECONDS – NON PERIODIC TRANSMISSIONS) INDICATING THE CURRENT BATTERY STATUS AND CURRENT LOCATION INFORMATION. THIS STATUS MESSAGE IS SENT AS LONG AS THE FALL DETECTION UNIT IS ACTIVATED. To deactivate the Fall Detection Unit, simply remove the batteries from the unit. HomeFree Systems Ltd Pendant (Panic Button) User Manual 5 1.2.1. Setting the Fall Alarm Volume The level of the audible fall alarm depends on the level defined on the Alarm Volume panel. Holding the Fall Alert Unit tightly, press the Alarm button until the desired level is selected. The alarm level options are; silent, low or loud. The illuminated LED indicates the alarm level selected. 1.2.2. Setting the Fall Alarm Delay The delay time of the audible fall alarm depends on the level defined on the Alarm Delay panel. Holding the Fall Alert Unit tightly, press the Delay button until the desired level is selected. The delay level options are; 3-second delay (non-illuminated LED) or 5-second delay (illuminated LED). The LED status indicates the delay level selected. 1.3. Initiating a Fall Alarm The Fall Detection Unit begins to monitor for falls after the resident sits or lies on the chair / bed mat for more than 15 consecutive-seconds. If the resident gets up from the chair or bed once the unit has gone into monitoring mode, an audible fall alarm is activated. ONCE IN ALARM MODE, THE FALL DETECTION UNIT SENDS AN ALARM TRANSMISSION (EVERY 18-22 SECONDS – NON PERIODIC TRANSMISSIONS) TO THE MONITORING STATION. THIS MESSAGE IS SENT UNTIL THE FALL ALARM IS RESET. HomeFree Systems Ltd Pendant (Panic Button) User Manual 6 To reset the fall alarm, hold the Fall Detection Unit tightly and press the Reset button for approximately 5 seconds. The audible alarm is deactivated. The Fall Detection Unit will continue monitoring once there is pressure on the chair / bed mat for more than 15 consecutive seconds. 1.3.1. Bypassing the Fall Alarm Holding the Fall Detection Unit tightly, press the Reset button for approximately 5 seconds. The fall monitoring is deactivated for approximately 30 seconds. The resident can now get up from the chair or bed without initiating and alarm. HomeFree Systems Ltd Pendant (Panic Button) User Manual 7 2. FCC Notices This note is applicable to the American FDU-800 NOTE The FDU-800 complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. This device has been tested and found to comply with the limits of the Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This device generates, uses and can radiate radio frequency energy and, if installed and used in accordance with the instruction, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this device does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to correct the interference by one or more of the following measures • Reorient or relocate the receiving antenna • Increase the separation…
Text truncated - open the document above for the full version.
TCB Confidentiality Form 25/01/2005 EMCCert DR. RAŠEK Boelwiese 5 91320 Ebermannstadt Germany Tel.: +49-9194-9331 Fax: +49-9194-7964-84 E-mail: [email protected] URL: http://www.emcc.de Gentlemen: This letter is to comply with Section 0.457(d)(2)(i) pertaining to confidential material. HomeFree would like the following document regarding this submission for FCC ID: QUX-FDU-800 to be kept confidential. Schematics: 1 Page. The above material contains trade secrets or technical data, which would customarily be guarded from competitors. We do not want this document to be accessible to the general public. Sincerely, Gil Gemer VP R&D
S/N Made in Israel III II I III 171FC?????
Product Label Location
HomeFree Systems Ltd Pendant (Panic Button) User Manual 1. Fall Detection Unit Operational Instructions The HomeFree system was designed to monitor special needs and Dementia individuals in the care center environment. The Fall Detection Unit is one of the many unique elements of this system. The Fall Detection Unit is a small, battery operated device, connected to a chair or bed monitoring mat, that can be used to notify care center staff members whenever the resident gets out of the chair or bed. The Fall Detection Unit is positioned on the chair or at the bedside. The Fall Detection Unit is not for use outside the monitored area. Mat Connection Jack Alarm Reset / Bypass Button Alarm Volume Panel LED Indicator Alert Delay Panel 3
REV ∆ Description Sheet Effected Date Drawn Checked A 06.01.05 D.Lanuel S.Cohen EMC Laboratory FCCID: QUX-FDU-800 Manufactured by HomeFree Ltd. EMC Test Report According FCC Part 15 Requirements Feb 2004 Function/Title Name Signature Date Prepared by Test Engineer D.Lanuel 06.01.05 Checked by Test Engineer D.Lanuel 06.01.05 Approved by EMC Lab. Manager S.Cohen 06.01.05 FDU 800 EMI Test Report Table of Contents Para Page No 1 INTRODUCTION...............................................................................................................................3 a. Scope.................................................................................................................... 3 b. Applicant Information:............................................................................................3 c. Test Performance:.................................................................................................. 3 2 TEST SUMMARY AND SIGNATURES...................................................................................................4 a. Test performed by:................................................................................................4 b. Test Report prepared by:........................................................................................4 c. Test Report Approved by:.......................................................................................4 3 E.U.T INFORMATION........................................................................................................................5 a. E.U.T description....................................................................................................5 b. E.U.T Test Configuration.........................................................................................5 c. E.U.T Mode of Operation description........................................................................5 4 BANDWIDTH OF THE EMISSION PART 15.231.C—TEST RESULTS........................................................6 a. Test Results Summary & Conclusions.......................................................................6 b. Limits of bandwidth................................................................................................6 c. Test Instrumentation and Equipment.......................................................................6 d. Results..................................................................................................................6 e. Procedure..............................................................................................................6 5 FIELD STRENGTH OF FUNDAMENTAL PART 15.231-TEST RESULTS......................................................7 a. Test Results Summary & Conclusions.......................................................................7 b. Limits of Field Strength for fundamental according 15.231.........................................7 c. Test Instrumentation and Equipment.......................................................................7 d. Test Results...........................................................................................................8 e. Test Procedure......................................................................................................8 6 RADIATED EMISSION PART 15.231 & 15.205-TEST RESULTS..............................................................9 a. Test Results Summary & Conclusions.......................................................................9 b. Limits of Radiated Interference Field Strength according 15.231................................9 c. Test Instrumentation and Equipment.......................................................................9 d. Preliminary Results...............................................................................................10 e. Final Results........................................................................................................10 f. Test Procedure....................................................................................................11 g. Final Test Setup...................................................................................................11 7 PLOTS...........................................................................................................................................13 8 PHOTOS........................................................................................................................................18 EMC/30020FC05003 2/20 FDU 800 EMI Test Report 1 Introduction a. Scope This document describes the measurement procedures and tests for FCC part 15 of the FDU 800 Manufactured by Elmotech Ltd. Equipment Under Test: FDU-800 FCCID QUX-FDU-800 Manufacturer: HomeFree Ltd. Serial Numbers: 11112 Mode of Operation: TX MODE Receiver operating frequwency: 318MHZ Year of Manufacture: 2004 b. Applicant Information: Applicant: HomeFree Ltd. Applicant Address 2, Habarzel Street Tel-Aviv Telephone: +972-3-6478871 FAX: +972-3-6478872 The testing was observed by: MICHAEL LIFSHITZ following applicant's personnel: c. Test Performance: Date of reception for testing: 22.012.04 Dates of testing 23.12.04 Test Laboratory Location TADIRAN EMC LAB , Hashoftim 26 Holon 58102 ISRAEL Tel: 972-3-5574476 Fax: 972-3-5575320 Applicable EMC Specification: Federal Communication Commission (FCC), Code of Federal Regulations 47, FCC Docket 89-103,Part 15: Radio Frequency Devices, Sections, 15.209, 15.231. Applicable EMC Specification: Federal Communication Commission (FCC), FCC Part 15: Radio Frequency Devices, 15.209 & 15.231 EMC/30020FC05003 3/20 FDU 800 EMI Test Report 2 Test Summary and Signatures. TADIRAN EMC Laboratory has completed testing of E.U.T in accordance with the requirements of the FCC Part 15 Regulations for Class B equipment. The E.U.T was found to comply with the requirements of the FCC Part 15 Regulations given below Test Test Description Section PASS/FAIL 1 Bandwidth of the emissi…
Text truncated - open the document above for the full version.
5 m 5 m 5 m 5 m 5 m 5 m 5 m 5 m 5 m 5 m S e c S e c S e c S e c S e c S e c S e c S e c S e c S e c 5 m 5 m 5 m 5 m 5 m S e c S e c S e c S e c S e c 60 Min Send Bat. Statu s 60 Min Send Bat. Statu s Send Bat. Statu s Send Bat. Statu s 60 Min 60 Min Alarm 1S e c 18-22 Sec 18-22 Sec Send Bat. Statu s Send Bat. Statu s FDU-800 – Time Diagram 1S e c Activ atin g 1 Sec RST Deactiv atio n
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 318 MHz - 318 MHz | - |

Pull Cord Station
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Pull Cord Station
Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
Universal Receiver
Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
Nurse Tracking Tag
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Nurse Tracking Tag
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter