Application Details

Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
Date of Grant
Oct 26, 2004
Application Purpose
Original Equipment
Date of Application
Oct 26, 2004
Equipment Note
iDEU - Data Extending Unit, iDEU-810
Frequency Range
318.00000000 - 318.00000000
Company
Attenti
Country
Israel

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Operational Description

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

HOMEFREE AT CARE CENTERS WIRELESS MONITORING UNIT (iDEU 810 / iDEU 810-2) INSTALLATION AND OPERATIONAL GUIDE October 2004 iDEU-810 Installation and Operational Guide F-3 Information in this documentation is subject to change without notice and does not represent a commitment on part of HomeFree Systems Ltd. Any unauthorized duplication or use of this documentation, in whole or in part, in print, or in any other storage or retrieval system is prohibited. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language in any form by any means for any purpose other than the purchaser’s personal use without the permission of HomeFree Systems Ltd. © 2002-04 HomeFree Systems Ltd. All rights reserved. Unless otherwise noted, all names of companies, products, street addresses, and persons contained herein are part of a completely fictitious scenario and are designed solely to document the use of a HomeFree product. HomeFree Systems USA Headquarters: HomeFree Inc. 6629 West Mill Road Milwaukee, WI 53218 Toll Free: 1-800-606-0661 Tel: 414-358-8200 Fax: 414-358-8100 e-mail:[email protected] International Headquarters: HomeFree Systems Ltd. 2 Ha-Barzel St., P.O. Box 13236, 61132 Tel Aviv, Israel Tel: +972-3-6488690 Fax: +972-3-6488691 e-mail:[email protected] Visit us at: www.homefreesys.com iDEU-810 Installation and Operational Guide TC-1 TABLE OF CONTENTS Section Page 1 INTRODUCTION..............................................................................................1-1 1.1 PARTS OF THE WIRELESS MONITORING UNIT (IDEU-810).............. 1-2 1.1.1 LED Panel................................................................................. 1-3 2 MOUNTING THE WIRELESS MONITORING UNIT (IDEU-810)............2-4 2.1 PERMANENT ANCHOR/DOWEL WALL FITTING................................ 2-4 2.2 TEMPORARY VELCRO WALL FITTING.............................................. 2-5 3 ACTIVATING THE WIRELESS MONITORING UNIT .............................3-7 4 FCC NOTICES...................................................................................................4-8 iDEU-810 Installation and Operational Guide 1-1 1 Introduction The new improved Wireless Monitoring Unit (iDEU-810) is a versatile combination of both transmitter and receiver that is designed to extend the transmission / reception range of HomeFree at Care Centers systems. The Wireless Monitoring Unit (iDEU-810) is one of many specifically positioned mini control units that are placed at various locations throughout the facility and are capable of receiving transmission signals from multiple sources and then transferring these signals to the next Wireless Monitoring Unit (iDEU-810) in the network or directly to the Wireless Monitoring Base Unit. The Wireless Monitoring Unit (iDEU-810) transmits on an American FCC tested and approved frequency; whereas the European version (iDEU-810) transmits on a European tested and approved frequency. From a user interface and functional point of view, the two models are identical, therefore this installation and operational guide serves both versions. iDEU-810 Installation and Operational Guide 1-2 1.1 Parts of the Wireless Monitoring Unit (iDEU-810) Figure 1-1 Wireless Monitoring Unit (iDEU-810) LED Panel Mounting Bracket iDEU-810 Installation and Operational Guide 1-3 1.1.1 LED Panel The faceplate of the Wireless Monitoring Unit (iDEU-810) comprises of 4 LEDs (Light emitting diodes). The purpose of each LED is explained in the following table: LED Description and Purpose Reception Blinks when receiving transmission signals Transmission Blinks when transmitting signals Charge Steady light indicates internal battery is fully charged. Charge LED blinks when internal battery is not fully charged Power Steady light indicates external power OK. Power LED blinks when external power is disconnected iDEU-810 Installation and Operational Guide 2-4 2 Mounting the Wireless Monitoring Unit (iDEU-810) For a Wireless Monitoring Unit to receive and transmit signals with maximum efficiency, it should be mounted on a wall or flat surface and positioned upright. The Wireless Monitoring Unit should also be mounted within reach of a power outlet (an electrician my need to install a power outlet near the chosen Wireless Monitoring Unit location). Note that the distance between the wall and the Wireless Monitoring Unit should be at least 10 cm. There are two ways to mount the Wireless Monitoring Unit. The first is to mount the Wireless Monitoring Unit on the wall using the fixed mounting brackets together with the dowel and screw fitting, and the second is to use the fixed mounting brackets and a Velcro fitting. Both of these fitting options are supplied with the Wireless Monitoring Unit. 2.1 Permanent Anchor/Dowel Wall Fitting The anchor/dowel wall fitting is generally used for installing the Wireless Monitoring Unit in a permanent location. In order to mount the Wireless Monitoring Unit using the anchor/dowel wall fittings, perform the following: 1. Place the Wireless Monitoring Unit on its faceplate with the fixed mounting brackets facing upwards. 2. Make a drilling template by tracing around the mounting brackets on the back of the Wireless Monitoring Unit onto a piece of A4 paper, not forgetting to mark the holes for the anchor/dowels. iDEU-810 Installation and Operational Guide 2-5 3. Using the template, drill two holes in the wall and place the supplied wall anchors/dowels into these holes. 4. Insert the supplied bolts/screws into the wall dowels, ensuring not to tighten the bolts/screws completely. 5. Holding the Wireless Monitoring Unit with the mounting brackets facing away from you, maneuver the holes on the mounting brackets over the bolts/screws already attached to the wall. 6. Pull the mounting brackets down over the bolts/screws slightly to ensure that the bolts/screws lock into the holes on wall bracket. 7. Using an extension rat…

Text truncated - open the document above for the full version.

Cover Letter(s)

TCB Confidentiality Form 18/07/2004 EMCCert DR. RAŠEK Boelwiese 5 91320 Ebermannstadt Germany Tel.: +49-9194-9331 Fax: +49-9194-7964-84 E-mail: [email protected] URL: http://www.emcc.de Gentlemen: This letter is to comply with Section 0.457(d)(2)(i) pertaining to confidential material. HomeFree would like the following document regarding this submission for FCC ID: QUX-IDEU-810 to be kept confidential. Schematics: 1 Page. The above material contains trade secrets or technical data, which would customarily be guarded from competitors. We do not want this document to be accessible to the general public. Sincerely, Gil Gemer VP R&D

External Photos

EUT Pictures

ID Label/Location Info

QUX-IDEU-810 Label

Operational Description

iDEU-810 Installation and Operational Guide 1-1 1 Introduction The new improved Wireless Monitoring Unit (iDEU-810) is a versatile combination of both transmitter and receiver that is designed to extend the transmission / reception range of HomeFree at Care Centers systems. The Wireless Monitoring Unit (iDEU-810) is one of many specifically positioned mini control units that are placed at various locations throughout the facility and are capable of receiving transmission signals from multiple sources and then transferring these signals to the next Wireless Monitoring Unit (iDEU-810) in the network or directly to the Wireless Monitoring Base Unit. The Wireless Monitoring Unit (iDEU-810) transmits on an American FCC tested and approved frequency; whereas the European version (iDEU-810) transmits on a European tested and approved frequency. From a user interface and functional point of view, the two models are identical, therefore this installation and operational guide serves both versions.

Test Report

REV ∆ Description Sheet Effected Date Drawn Checked A 13.09.04 D.Lanuel S.Cohen EMC Laboratory FCCID: QUX-IDEU-810 Manufactured by HomeFree System Ltd. EMC Test Report According FCC Part 15 Requirements Feb 2004 Function/Title Name Signature Date Prepared by Test Engineer D.Lanuel 13.09.04 Checked by Test Engineer D.Lanuel 13.09.04 Approved by EMC Lab. Manager S.Cohen 13.09.04 SPT-06G ROSSLARE EMI Test Report Table of Contents Para Page No 1 INTRODUCTION...............................................................................................................................3 2 TEST SUMMARY AND SIGNATURES. ..................................................................................................4 3 E.U.T INFORMATION........................................................................................................................5 4 BANDWIDTH OF THE EMISSION PART 15.231.C—TEST RESULTS........................................................6 5 FIELD STRENGTH OF FUNDAMENTAL PART 15.231-TEST RESULTS......................................................7 6 RADIATED EMISSION PART 15.231 & 15.205-TEST RESULTS ..............................................................9 7 RADIATED EMISSION PART 15.109-TEST RESULTS(FOR STBY MODE)...............................................14 8 CONDUCTED EMISSION, AC POWER LEADS ACCORDING TO FCC 15.107...........................................16 9 PLOTS...........................................................................................................................................19 EMC/30020FC04040 2/30 SPT-06G ROSSLARE EMI Test Report 1 Introduction a. Scope This document describes the measurement procedures and tests for FCC part 15 of the IDEU 810-1 Manufactured by HomeFree System Ltd. Equipment Under Test: IDEU-810 FCCID QUX-IDEU-810 Manufacturer: HomeFree System Ltd. Serial Numbers: 0001 Mode of Operation: TX & RX MODE Receiver operating frequwency: 318MHZ Year of Manufacture: 2004 b. Applicant Information: Applicant: HomeFree System Ltd. Applicant Address 2, Habarzel Street Tel-Aviv Telephone: +972-3-6478871 FAX: +972-3-6478872 The testing was observed by LEV ROSMAN following applicant's personnel: c. Test Performance: Date of reception for testing: 22.06.04 Dates of testing 24.06.04 Test Laboratory Location TADIRAN EMC LAB , Hashoftim 26 Holon 58102 ISRAEL Tel: 972-3-5574476 Fax: 972-3-5575320 Applicable EMC Specification: Federal Communication Commission (FCC), Code of Federal Regulations 47, FCC Docket 89-103,Part 15: Radio Frequency Devices, Sections 15.109, 15.209,15.107, 15.207 & 15.231. Applicable EMC Specification: Federal Communication Commission (FCC), FCC Part 15: Radio Frequency Devices, Sections 15.109, 15.209 & 15.231.15.207 EMC/30020FC04040 3/30 SPT-06G ROSSLARE EMI Test Report 2 Test Summary and Signatures. TADIRAN EMC Laboratory has completed testing of E.U.T in accordance with the requirements of the FCC Part 15 Regulations for Class B equipment. The E.U.T was found to comply with the requirements of the FCC Part 15 Regulations given below Test Test Description Section PASS/FAIL 1 Bandwidth of the emission 15.231 PASS 2 Field strength of fundamental 15.231 PASS 3 Radiation emission 15.109 PASS 4 Radiation emission 15.231 & 15.205 PASS 5 Conducted emission 15.207 PASS a. Test performed by: Mr. D. Lanuel Test Engineer b. Test Report prepared by: Mr. D. Lanuel Test Engineer c. Test Report Approved by: Mr. Samuel Cohen EMC Lab. Manager EMC/30020FC04040 4/30 SPT-06G ROSSLARE EMI Test Report 3 E.U.T information a. E.U.T description The EUT, Wireless Monitoring Unit (iDEU-810), is a wall mounted microprocessor transceiver, operating at 318MHz. It is a part of wandering prevention system. The iDEU extends the reception range of an electronic monitoring receiver by receiving and re-transmitting data. It utilized single antenna. The EUT powered from mains via AC/DC adapter 7.5V and includes a 3.6V back-up battery. b. E.U.T Test Configuration E.UT. Test configuration is shown in figure bellow Internal Battery Integral Antenna E.U.T AC/DC Converter Charger c. E.U.T Mode of Operation description (1) 318MHz TX Mode operated by battery (2) 318MHz TX Mode operated by AC/DC Adapter (3) 318MHz RX Mode operated by battery (4) 318MHz RX Mode operated by AC/DC Adapter EMC/30020FC04040 5/30 SPT-06G ROSSLARE EMI Test Report 4 BANDWIDTH OF THE EMISSION part 15.231.c—TEST RESULTS E.U.T: IDEU 810-1 S/N 64028 Test Method: ANSI C63.4 Date: 24/06/04 Relative Humidity: 37% Ambient Temperature: 22c Air Pressure: 1042hpa Test Setup: Figure 5f Testing Engineer: D.Lanuel Date 01/07/04 a. Test Results Summary & Conclusions The E.U.T was found in compliance with Bandwidth of Radiated Emission fundamental frequency requirement according to section 15.231.c b. Limits of bandwidth The test unit shall meet the limits of Table 8.b Table 4.b Limits For Bandwidth Frequency (MHz) Bandwidth Max Limits (%) Bandwidth Max Limits (KHz) 318.01000 0.25 795 c. Test Instrumentation and Equipment Table 4.c Test Instrumentation and Equipment Item Model Manufacturer Next Date Calibration Spectrum Analyzer 8593E HP 31/01/05 Broadband Antenna BTA-L FRANKONIA 10.04.06 d. Results Table 4.d Bandwidth Test Result Frequency (MHz) Bandwidth (KHz) Bandwidth Max Limit (KHz) Plot No PASS/FAIL 318.00 234.5 1085 1 PASS e. Procedure The Bandwidth is determined at the point 20db down from the modulated carrier, while the spectrum analyzer was set to “max hold” and VBW –10KHz. EMC/30020FC04040 6/30 SPT-06G ROSSLARE EMI Test Report 5 field strength of fundamental part 15.231-TEST RESULTS E.U.T: IDEU 810-1 S/N 64028 Test Method: ANSI C63.4 Date: 24/06/04 Relative Humidity: 37% Ambient Temperature: 22c Air Pressure: 1042hpa Test Setup: Figure 5f Testing Engineer: D.Lanuel Date 01/07/04 a. Test Results Summary & Conclusions The E.U.T was found in compliance with fundamental frequency requirement b. Limits of Field Strength for fundamental according 15.231 The test unit shall meet t…

Text truncated - open the document above for the full version.

Test Setup Photos

Test Pictures Radiated Emission Test Setup up to 30MHz Radiated Emission Test Setup 30MHz-1GHz Radiated Emission Test Setup 1GHz-18GHz conducted Emission Set Up

Contact Information

Applicant

Stan DuPont(Electronic Engineer)
[email protected]813-749-5454Fax: 813-749-5474

Test Firm

Elbit Systems Land C41Tadiran Ltd.Samuel Cohen
[email protected]97235574476Fax: 97235575320

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231318 MHz - 318 MHz-
Confidentiality
Long Term

Other Applications from Attenti

Pull Cord Station - FCC ID QUX-PC-840-2 - Attenti
QUX-PC-840-2

Pull Cord Station

Sep 12, 2012

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Pull Cord Station - FCC ID QUX-PC-840 - Attenti
QUX-PC-840

Pull Cord Station

Sep 11, 2012

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
Universal Receiver - FCC ID QUX-URC-830-2 - Attenti
QUX-URC-830-2

Universal Receiver

Sep 09, 2012

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
Nurse Tracking Tag - FCC ID QUX-NTT-830-2 - Attenti
QUX-NTT-830-2

Nurse Tracking Tag

Jul 29, 2012

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Nurse Tracking Tag - FCC ID QUX-NTT-830 - Attenti
QUX-NTT-830

Nurse Tracking Tag

Jul 29, 2012

Equipment Class