FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Attenti/
  3. QUX-UTX-830

QUX-UTX-830Universal Transmitter - UTX-830

Attenti
Universal Transmitter - UTX-830 - FCC ID QUX-UTX-830 - Attenti
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Jul 22, 2007
Application Purpose
Original Equipment
Date of Application
Jul 22, 2007
Equipment Note
Universal Transmitter - UTX-830
Frequency Range
318.00000000 - 318.00000000
Company
Attenti
Country
Israel

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Operational Description

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Universal Transmitter USER MANUAL FCC ID: QUX-UTX-830 July 2007 HomeFree Systems Ltd Universal Transmitter User Manual 1 Table of Contents 1. Foreword...................................................................................2 1.1. Activating the Universal Transmitter:.......................................2 1.2. Activating a Panic Alert:............................................................3 1.3. Deactivating a Panic Alert:........................................................3 1.4. Deactivating the Universal Transmitter:....................................3 1.5. Cleaning Instructions.................................................................4 2. FCC Notices..............................................................................5 HomeFree Systems Ltd Universal Transmitter User Manual 2 1. Foreword The HomeFree at Care Centers system was designed to monitor special needs and Dementia individuals in the care center environment. The Universal Transmitter is one of the many unique elements of this system. 1.1. The UTX-830 is a small frame-head device, to be installed at internal or external doors of nursing homes and assisted leaving homes. The device is combined with a magnet on the door to detect door open / close status. When the door is open, the device shall transmit panic messages once every 18-22 seconds (random interval within this range), until closed door is detected. It will be possible to turn the UTX830 on and off by pulling out the battery (for saving battery life and for aviation safety while shipped). While UTX-830 is ON, it shall transmit a status message, once every hour, to indicate that it is still functioning and to report its battery level. 1.2. The UTX-830 is a stand-alone unit. It can be battery operated or externally powered by a dedicated AC adaptor; it has RF transmitter module, a microcontroller, which controls the UTX- 830 operation, one PCB, and a door magnet. 1.3. The UTX-830 has one RF channel. It is 318 MHz carrier with FSK modulated data. 1.1. Activating the Universal Transmitter: The Universal Transmitter is turned off by the manufacturer before shipment and must be activated before use. To activate, insert the battery into the battery case, and/or plug in the power supply to the correct jack. HomeFree Systems Ltd Universal Transmitter User Manual 3 Once the Universal Transmitter is working, it sends a status message to the monitoring station. The monitoring station then indicates the current battery status. This status message is sent until the Universal Transmitter is deactivated. 1.2. Activating a Panic Alert: The UTX-830 sends a panic transition alert message to the monitoring station in the following way, activate the reed switch (Normally open / Close). Once in panic alert mode, the Universal Transmitter sends a panic alert message to the monitoring station. This message is sent until the panic alert is deactivated. 1.3. Deactivating a Panic Alert: Change the status of the monitoring device from Normally Open to normally close and vice versa. Even though the panic alert has been deactivated, the Universal Transmitter is still working. Therefore, the Universal Transmitter still sends a status message to the monitoring station. This status message is sent until the Universal Transmitter is deactivated. 1.4. Deactivating the Universal Transmitter: Holding the Universal Transmitter: 1. Take off the power supply from the unit. 2. Disconnect the battery from the case. HomeFree Systems Ltd Universal Transmitter User Manual 4 1.5. Cleaning Instructions A soft brush and any cleaning solution are all that is needed to clean the Universal Transmitter. Alcohol based solutions; Soapy water or Lysol can be used to clean the Universal Transmitter. Holding the strap or leash, spray the Universal Transmitter (Panic Button) with cleaning solution of choice (see above). Using a piece of cloth or a paper towel, dry the outer side of the Universal Transmitter. Lay the Universal Transmitter on the towel with its inner side facing up. Using a soft brush or another piece of cloth/towel gently scrub the inner side of the Universal Transmitter. Dry the Universal Transmitter (Panic Button) using a piece of cloth/paper towel or simply let it dry. HomeFree Systems Ltd Universal Transmitter User Manual 5 2. FCC Notices This note is applicable to the American Universal Transmitter (Panic Button) NOTE The Universal Transmitter complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. This device has been tested and found to comply with the limits of the Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This device generates uses and can radiate radio frequency energy and, if installed and used in accordance with the instruction, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this device does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to correct the interference by one or more of the following measures • Reorient or relocate the receiving antenna • Increase the separation between the equipment and the receiver. HomeFree Systems Ltd Universal Transmitter User Manual 6 • Consult the dealer or an experienced radio/TV technician for help. CAUTION Any changes or modifications not expressly approved by the grantee of this device could void the user’s authority to operate the equipment. For Customer Support contact: Home Free Systems Inc. Wireless Tele home Care Solutions 6629 West Mill Road Milwaukee, WI 53218 USA Toll Free 1-…

Text truncated - open the document above for the full version.

Block Diagram

UTX-830 Block Diagram

Cover Letter(s)

TCB Confidentiality Form 05/07/2007 EMCCert DR. RAŠEK Boelwiese 5 91320 Ebermannstadt Germany Tel.: +49-9194-9331 Fax: +49-9194-7964-84 E-mail: [email protected] URL: http://www.emcc.de Gentlemen, This letter is to comply with Section 0.457(d)(2)(i) pertaining to confidential material. HomeFree would like the following document regarding this submission for FCC ID: QUX-PC-830 to be kept confidential. Schematics: 1 Page. The above material contains trade secrets or technical data, which would customarily be guarded from competitors. We do not want this document to be accessible to the general public. Sincerely, Yoel Lavian VP R&D

Operational Description

Universal Transmitter UTX830 Operational description 1. General Description 1.1. The UTX830 is a small frame-head device, to be installed at internal or external doors of nursing homes and assisted leaving homes. The device is combined with a magnet on the door to detect door open / close status. When the door is open, the device shall transmit panic messages once every 18-22 seconds (random interval within this range), until closed door is detected. It will be possible to turn the UTX830 on and off by pulling out the battery (for saving battery life and for aviation safety while shipped). While UTX830 is ON, it shall transmit a status message, once every hour, to indicate that it is still functioning and to report its battery level. 1.2. The UTX830 is a stand-alone unit. It can be battery operated or externally powered by a dedicated AC adaptor; it has RF transmitter module, a microcontroller, which controls the UTX830 operation, one PCB, and a door magnet. 1.3. The UTX830 has one RF channel. It is 318 MHz carrier with FSK modulated data. 2. Functional Description 2.1. The UTX830 has four modes of operation. a) ACTIVATING THE UTX830: Three 6.5ms transmissions within 1s. b) ACTIVE (door closed): The UTX830 sends a status message to the monitoring station (one 6.5ms transmission per hour) to indicate the current battery status. c) ACTIVE to PANIC transition: The UTX830 sends a panic transition alert message to the monitoring station in the following way. A burst of three 6.5ms transmissions within 1s. d) PANIC ALERT (door open): The UTX830 sends a 6.5ms alert message transmission every randomly chosen interval of 18-22 s. This panic alert message is re-sent until the "door close" is detected. e) PANIC to ACTIVE transition: The UTX830 sends an active transition alert message to the monitoring station in the following way. A burst of three 6.5ms transmissions within 1s . UTX830 time diagram 6.5ms Start additional Panic Alert 6.5ms 6.5ms 1s 6.5ms 18-22 s 18-22 s 6.5ms Panic alert mode 6.5 ms 6.5ms 6.5 ms 6.5ms 6.5ms 60 min Send battery status Send battery status 60 min Activating the UTX830 Active mode 6.5ms 60 min Send battery status Send battery status 60 min Deactivation the Panic alert Active mode additional Panic Alert 1 s 6.5ms 6.5ms 1 s 6.5ms 6.5ms Activating the UTX830

Test Report

REV Δ Description Sheet Effected Date Drawn Checked A July 13, 2007 S.Cohen S.Cohen EMC Laboratory UTX-830 FCCID: QUX-UTX-830 Manufactured by HomeFree Ltd. EMC Test Report According to FCC Part 15 Requirements July 07 Function/Title Name Signature Date Prepared by Test Engineer S.Cohen July 13, 2007 Checked by Test Engineer S.Cohen July 13, 2007 Approved by EMC Lab. Manager S.Cohen July 13, 2007 QUX-UTX-830 FCC Report EMC/30020FC07141 2/39 Table of Contents Para Page No 1 INTRODUCTION...............................................................................................................................3 2 TEST SUMMARY AND SIGNATURES. ..................................................................................................4 3 E.U.T INFORMATION........................................................................................................................5 4 BANDWIDTH OF THE EMISSION PART 15.231.C—TEST RESULTS ........................................................6 5 FIELD STRENGTH OF FUNDAMENTAL PART 15.231-TEST RESULTS......................................................7 6 RADIATED EMISSION PART 15.231 & 15.205-TEST RESULTS ..............................................................9 7 RADIATED EMISSION PART 15.109-TEST RESULTS (FOR STBY MODE). ............................................. 13 8 PLOTS........................................................................................................................................... 15 9 CORRECTION FACTORS.................................................................................................................. 37 10 ABBREVIATIONS AND ACRONYMS ................................................................................................... 39 QUX-UTX-830 FCC Report EMC/30020FC07141 3/39 1 Introduction a. Scope This document describes the measurement procedures and tests for FCC part 15 of the QUX- UTX-830 Manufactured by HomeFree Ltd. Equipment Under Test: UTX-830 FCCID QUX-UTX-830 Manufacturer: HomeFree Ltd. Serial Numbers: 31834 Mode of Operation: TX MODE Receiver operating frequency: 318MHZ Year of Manufacture: 2007 b. Applicant Information: Applicant: HomeFree Ltd. Applicant Address 2, Habarzel Street Tel-Aviv Telephone: +972-3-6478871 FAX: +972-3-6478872 The testing was observed by: Oren Davidov Following applicant's personnel: c. Test Performance: Date of reception for testing: 17.06.07 Dates of testing; 17.06.07 Test Laboratory Name: Tadiran EMC Laboratory Address: Hashoftim 26 Holon Zip Code: 267,5812 City: Holon Country: Israel Telephone: 03-5574476 Fax: 03-5575320 Email: [email protected] Applicable EMC Specification: Federal Communication Commission (FCC), Code of Federal Regulations 47, FCC Docket 89-103, Part 15: Radio Frequency Devices, Sections 15.109, 15.209 & 15.231. Applicable EMC Specification: Federal Communication Commission (FCC), FCC Part 15: Radio Frequency Devices, Sections 15.109, 15.209 & 15.231. QUX-UTX-830 FCC Report EMC/30020FC07141 4/39 2 Test Summary and Signatures. TADIRAN EMC Laboratory has completed testing of E.U.T in accordance with the requirements of the FCC Part 15 Regulations for Class B equipment. The E.U.T was found to comply with the requirements of the FCC Part 15 Regulations given below Test Test Description Section PASS/FAIL 1 Bandwidth of the emission 15.231 PASS 2 Field strength of fundamental 15.231 PASS 3 Radiation emission 15.231 & 15.205 PASS 4 Radiation emission 15.109 PASS a. Test performed by: Mr. S. Kozliner Test Engineer b. Test Report prepared by: Mr. S. Cohen EMC Lab. Manager c. Test Report Approved by: Mr. Samuel Cohen EMC Lab. Manager QUX-UTX-830 FCC Report EMC/30020FC07141 5/39 3 E.U.T information a. E.U.T description The EUT (UTX-830) is a compact RF transmitter unit operates at 318MHz that is generally carried out and can be used in several modes of operation. The EUT is a Frame Head device, powered by Li/MnO 2 battery (operation voltage 3V) and external 4.5VDC power supply (optional). b. E.U.T Test Configuration E.UT. Test configuration is shown in figure below Internal Battery Integral Antenna E.U.T c. E.U.T Mode of Operation description (1) 318MHz TX Mode Power Supply 4.5VDC QUX-UTX-830 FCC Report EMC/30020FC07141 6/39 4 BANDWIDTH OF THE EMISSION part 15.231.c—TEST RESULTS E.U.T: UTX 830 S/N 31834 Test Method: ANSI C63.4 Date: 16/05/2007 Relative Humidity: 37% Ambient Temperature: 22c Air Pressure: 1042hpa Test Setup: Figure 1 Testing Engineer: S.Kozliner Date 16.06.2007 a. Test Results Summary & Conclusions The E.U.T was found in compliance with Bandwidth of Radiated Emission fundamental frequency requirement according to section 15.231.c b. Limits of bandwidth The test unit shall meet the limits of Table 1 Table- 1 Limits For Bandwidth Frequency (MHz) Bandwidth Max Limits (%) Bandwidth Max Limits (KHz) 318 0.25 795 c. Test Instrumentation and Equipment Table- 2 Test Instrumentation and Equipment Item Model Manufacturer Next Date Calibration Spectrum Analyzer 8593E HP 31/05/08 Broadband Antenna BTA-L FRANKONIA 15.04.08 d. Results Table- 3 Bandwidth Test Result Frequency (MHz) Bandwidth (KHz) Bandwidth Max Limit (KHz) Plot No PASS/FAIL 318 327.5 795 1 PASS e. Procedure The Bandwidth is determined at the point 20db down from the modulated carrier, while the spectrum analyzer was set to “max hold” and VBW 10 KHz. QUX-UTX-830 FCC Report EMC/30020FC07141 7/39 5 Field strength of fundamental part 15.231-TEST RESULTS E.U.T: UTX 830 S/N 31834 Test Method: ANSI C63.4 Date: 16/05/2007 Relative Humidity: 37% Ambient Temperature: 22c Air Pressure: 1042hpa Test Setup: Figure 1 Testing Engineer: S.Kozliner Date 16.05.2007 a. Test Results Summary & Conclusions The E.U.T was found in compliance with fundamental frequency requirement b. Limits of Field Strength for fundamental according 15.231 The test unit shall meet the limits of Table 4. Table- 4 Limits For Fundamental Frequency (MHz) Average Max Limits (dBμV/m) Peak Max Limits (dBμV/…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Stan DuPont(Electronic Engineer)
[email protected]813-749-5454Fax: 813-749-5474

Test Firm

Elbit Systems Land C41Tadiran Ltd.Samuel Cohen
[email protected]97235574476Fax: 97235575320

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231318 MHz - 318 MHz-
Confidentiality
Long Term

Other Applications from Attenti

Pull Cord Station - FCC ID QUX-PC-840-2 - Attenti
QUX-PC-840-2

Pull Cord Station

Sep 12, 2012

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Pull Cord Station - FCC ID QUX-PC-840 - Attenti
QUX-PC-840

Pull Cord Station

Sep 11, 2012

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
Universal Receiver - FCC ID QUX-URC-830-2 - Attenti
QUX-URC-830-2

Universal Receiver

Sep 09, 2012

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
Nurse Tracking Tag - FCC ID QUX-NTT-830-2 - Attenti
QUX-NTT-830-2

Nurse Tracking Tag

Jul 29, 2012

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Nurse Tracking Tag - FCC ID QUX-NTT-830 - Attenti
QUX-NTT-830

Nurse Tracking Tag

Jul 29, 2012

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter