Zhongshan Tianpeng Electronic Lighting and Communication Equipment Factory Self-Ballasted Fluorescent Lamp FCC ID: QXGSRS This product may cause interference to radio equipment and should not be installed near maritime safety communications equipment or other critical navigation or communication equipment operating between 0.45-30MHz. Made in China
Block Diagram A. Rectifier B. Starting Circuit C. High Frequency Signal Generator D. Tube Lighting Input: 120V/60Hz Fundamental Operation Frequency is 40KHz or so. A B C D
SRS-9W SRS-11W SRS-13W SRS-15W
Label Location Information EUT Bottom View/Proposed FCC ID Label Location SRS series
Label Drawing β FCC ID Sample Label The Label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time of purchase. Model Number: SRS-9W FCC ID: QXGSRS Zhongshan Tianpeng Made in China
SRS-9W SRS-11W SRS-13W SRS-15W
1234 A B C D 4 321 D C B A Title NumberRevisionSize A4 Date:21-Mar-2003Sheet of File:C:\KMOCAT~1\5SRS.S01Drawn By: C1 C7 R3 R6 D3 D4 D1 D2 R1 D5 C4 F L1 R5 C6 2N 2N 15N L2 R4 R2 DB3 C5 T1 T2 1 2 0 V / 6 0 H z C3 C2 SRS 9W-15W/FCC UL L3 ε°θΊζ εε· εζ° SRS-9W SRS-11W SRS-13W SRS-15W L2 5mH 4.5mH 4.5mH 4.2mH R3R6 2.2 1 1 1 C6 152/1KV 152/1KV 222/1KV 222/1KV LAMP 9W 11W 13W 15W 1 0 U / 2 0 0 V 104/250V 510K 510K 2 2 3 / 1 0 0 V 1 0 2 / 1 K V 10 10 104/250V L A M P
FCC TEST REPORT UNDER FCC Part 18 RF Lighting Device PREPARED FORοΌ Zhongshan Tianpeng Electronic Lighting and Communication Euqipment Factory Tian Peng Industrial District HengLan Town, Zhongshan, GuangDong, China February 18, 2003 PREPARED BY οΌ Shenzhen Academy of Metrology & Quality Inspection Longzhu Road, Nanshan FCC Registration Number: 97379 FCC ID: QXGSRS EUT: Self-Ballasted Fluorescent Lamp Model: SRS-9W; SRS-11W; SRS-13W; SRS-15W Report Type: Original Report Test Engineer: Peter Lin Test Date: January 16, 2003 Review By: Apollo Liu Zhongshan Tianpeng Electronic Lighting and Communication Equipment Factory FCC ID: QXGSRS FCC ID Report Report #: KA200212120104J Page 2 of 26 TABLE OF CONTENTS 1. Summary of Test Results.....................................................................................................................................................3 2. Test Statement......................................................................................................................................................................4 2. 1 Test Statement.................................................................................................................................................................4 2. 2 Departure From Document Policies, Procedure or Specifications, The Statement.........................................................4 3. EUT Modifications..............................................................................................................................................................5 4. Conducted Power Line Test................................................................................................................................................6 4. 1 Test Equipment...............................................................................................................................................................6 4. 2 Test Procedure................................................................................................................................................................6 4. 3 Test Setup.......................................................................................................................................................................6 4. 4 Configuration of The EUT..............................................................................................................................................7 4. 5 EUT Operating Condition...............................................................................................................................................8 4. 6 Conducted Power Line Emission Limits........................................................................................................................8 4. 7 Conducted Power Line Test Result.................................................................................................................................9 5. Radiated Emission Test.....................................................................................................................................................15 5. 1 Test Equipment.............................................................................................................................................................15 5. 2 Test Procedure..............................................................................................................................................................15 5. 3 Radiated Test Setup......................................................................................................................................................15 5. 4 Configuration of The EUT............................................................................................................................................16 5. 5 EUT Operating Condition.............................................................................................................................................16 5. 6 Radiated Emission Limit..............................................................................................................................................16 5. 7 Radiated Emission Test Result......................................................................................................................................17 6. Photos of Testing................................................................................................................................................................23 6. 1 EUT Test Photographs..................................................................................................................................................23 6. 2 EUT Detailed Photographs...........................................................................................................................................24 7. FCC ID Label.....................................................................................................................................................................25 8. Test Equipment..................................................................................................................................................................26 Zhongshan Tianpeng Electronic Lighting and Communication Equipment Factory FCC ID: QXGSRS FCC ID Report Report #: KA200212120104J Page 3 of 26 1. Summary of Test Results The EUT has been tested according to the following specifications: Standard Test Type Result Notes FCC Part 18 Conducted Test PASS The test results meet limit FCC Part 18 Radiated Test PASS The test results meet limit. Zhongshan Tianpeng Electronic Lighting and Communication Equipment Factory FCC ID: QXGSRS FCC ID Report Report #: KA200212120104J Page 4 of 26 2. Test Statement 2. 1 Test Statement A. This statement explains the test condition of this project. The EUT was tested under the condition of each test item. B. The data shown in this report reflects the wβ¦
Text truncated - open the document above for the full version.
Conducted Emission Test View Radiated emission test view
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 18 | 0.04 MHz - 0.045 MHz | - |

Self-Ballasted Fluorescent Lamp
Equipment Class
8CC - Part 18 Consumer Device
Self-Ballasted Flourescent Lamp
Equipment Class
8CC - Part 18 Consumer Device
Self-Ballasted Fluorescent Lamp
Equipment Class
8CC - Part 18 Consumer Device
Self-Ballasted Fluorescent Lamp
Equipment Class
8CC - Part 18 Consumer Device
Self-Ballasted Fluorescent Lamp
Equipment Class
8CC - Part 18 Consumer Device