Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Zhongshan Tianpeng Electronic Lighting and Communication Equipment Factory Self-Ballasted Fluorescent Lamp FCC ID: QXGSUF This product may cause interference to radio equipment and should not be installed near maritime safety communications equipment or other critical navigation or communication equipment operating between 0.45-30MHz. Made in China
Block Diagram A. Rectifier B. Starting Circuit C. High Frequency Signal Generator D. Tube Lighting Input: 120V/60Hz Fundamental Operation Frequency is 40KHz or so. A B C D
SUF-15W SUF-20W
Label Location Information EUT Bottom View/Proposed FCC ID Label Location SUF series
Label Drawing β FCC ID Sample Label The Label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time of purchase. Model Number: SUF-15W FCC ID: QXGSUF Zhongshan Tianpeng Made in China
SUF-15W SUF-20W
1234 A B C D 4 321 D C B A Title NumberRevisionSize A4 Date:21-Mar-2003Sheet of File:D:\PCB\6SUF15~1.S01Drawn By: T2 T1 C3 DB3 R2 R3 L2 N3 N2 N1 C7 R4 L1 F C4 C2 D5 R1 D2 D1 D4 D3 R6 R5 C6 C1 Chang EE19 1 2 0 V / 6 0 H z SUF15-20W /FCC UL L A M P D7 D6 C5 Uε°ε L3 104/250V 104/250V 1M430K 2 2 3 / 2 5 0 V SUF-15W SUF-20W εε· εζ°C2L3T1 T2L2R3 R4R5 R6C7LAMP 15U/200V3:10:3130032.5mH151.5222/1KV 22U/200V3:7:3130052mH101272/1KV 4U 15W 4U 20W 562/1KV
FCC TEST REPORT UNDER FCC Part 18 RF Lighting Device PREPARED FORοΌ Zhongshan Tianpeng Electronic Lighting and Communication Euqipment Factory Tian Peng Industrial District HengLan Town, Zhongshan, GuangDong, China February 18, 2003 PREPARED BY οΌ Shenzhen Academy of Metrology & Quality Inspection Longzhu Road, Nanshan FCC Registration Number: 97379 FCC ID: QXGSUF EUT: Self-Ballasted Fluorescent Lamp Model: SUF-15W; SUF-20W Report Type: Original Report Test Engineer: Peter Lin Test Date: January 16, 2003 Review By: Apollo Liu Zhongshan Tianpeng Electronic Lighting and Communication Equipment Factory FCC ID: QXGSUF FCC ID Report Report #: KA200212120105J Page 2 of 20 TABLE OF CONTENTS 1. Summary of Test Results.....................................................................................................................................................3 2. Test Statement......................................................................................................................................................................4 2. 1 Test Statement.................................................................................................................................................................4 2. 2 Departure From Document Policies, Procedure or Specifications, The Statement.........................................................4 3. EUT Modifications..............................................................................................................................................................5 4. Conducted Power Line Test................................................................................................................................................6 4. 1 Test Equipment...............................................................................................................................................................6 4. 2 Test Procedure................................................................................................................................................................6 4. 3 Test Setup.......................................................................................................................................................................6 4. 4 Configuration of The EUT..............................................................................................................................................7 4. 5 EUT Operating Condition...............................................................................................................................................8 4. 6 Conducted Power Line Emission Limits........................................................................................................................8 4. 7 Conducted Power Line Test Result.................................................................................................................................9 5. Radiated Emission Test.....................................................................................................................................................12 5. 1 Test Equipment.............................................................................................................................................................12 5. 2 Test Procedure..............................................................................................................................................................12 5. 3 Radiated Test Setup......................................................................................................................................................12 5. 4 Configuration of The EUT............................................................................................................................................13 5. 5 EUT Operating Condition.............................................................................................................................................13 5. 6 Radiated Emission Limit..............................................................................................................................................13 5. 7 Radiated Emission Test Result......................................................................................................................................14 6. Photos of Testing................................................................................................................................................................17 6. 1 EUT Test Photographs..................................................................................................................................................17 6. 2 EUT Detailed Photographs...........................................................................................................................................18 7. FCC ID Label.....................................................................................................................................................................19 8. Test Equipment..................................................................................................................................................................20 Zhongshan Tianpeng Electronic Lighting and Communication Equipment Factory FCC ID: QXGSUF FCC ID Report Report #: KA200212120105J Page 3 of 20 1. Summary of Test Results The EUT has been tested according to the following specifications: Standard Test Type Result Notes FCC Part 18 Conducted Test PASS The test results meet limit FCC Part 18 Radiated Test PASS The test results meet limit. Zhongshan Tianpeng Electronic Lighting and Communication Equipment Factory FCC ID: QXGSUF FCC ID Report Report #: KA200212120105J Page 4 of 20 2. Test Statement 2. 1 Test Statement A. This statement explains the test condition of this project. The EUT was tested under the condition of each test item. B. The data shown in this report reflects the worst β case data β¦
Text truncated - open the document above for the full version.
Conducted Emission Test View Radiated emission test view
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 18 | 0.04 MHz - 0.045 MHz | - |

Self-Ballasted Fluorescent Lamp
Equipment Class
8CC - Part 18 Consumer Device
Self-Ballasted Flourescent Lamp
Equipment Class
8CC - Part 18 Consumer Device
Self-Ballasted Flourescent Lamp
Equipment Class
8CC - Part 18 Consumer Device
Self-Ballasted Fluorescent Lamp
Equipment Class
8CC - Part 18 Consumer Device
Self-Ballasted Fluorescent Lamp
Equipment Class
8CC - Part 18 Consumer Device