Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Model No : 719BF COLOR MONITOR USER’S GUIDE 1. Read all of these instructions.2. Save these instructions for later use. 3. Unplug this monitor from thewall outlet before cleaning. Do notuse liquid cleaners or aerosolcleaners. Use a damp cloth forcleaning. 4. Do not use attachments not recommended bythe monitor manufacturer as they may causehazards.5. Do not use this monitor near water, e.g., near abathtub, washbowl, kitchen sink, or laundry tub,in a wet basement, or near a swimming pool, etc. 6. Do not place this monitor on anunstable cart, stand, or table. Themonitor may fall, causing seriousinjury to a child or adult, andserious damage to the appliance. 7. Slots and openings in thecabinet and the back or bottom areprovided for ventilation, to ensurereliable operation of the monitor,and to protect it from overheating. These openings must not be blocked or covered.The openings should never be blocked byplacing the monitor on a bed, sofa, rug, or othersimilar surface. This monitor should never beplaced near or over a radiator or heat register.This monitor should not be placed in a built-ininstallation such as a bookcase unless properventilation is provided. 8. This monitor should be operatedonly from the type of power sourceindicated on the marking label. Ifyou are not sure of the powersupplied to your home, consult your monitor dealer or local power company. 9. This monitor is equipped with a3-wire grounding-type plug, Thatis, a plug having a third(grounding) pin. This plug willonly fit into a grounding-type power outlet. This is a safety feature. If you areunable to insert the plug into the outlet, contactyour electrician to replace your obsolete outlet.Do not defeat the purpose of the grounding-typeplug. 10. Do not allow anything to reston the power cord. Do not locatethis monitor where the cord will beabused by people walking on it. 11. Follow all warnings and instructions markedon the monitor. IMPORTANT SAFEGUARDS 12. For added protection for this monitor during a lightning storm,or when it is left unattended andunused for long periods of time,unplug it from the wall outlet. This will prevent damage to the monitor and/or thecomputer due to lightning and power line surges. 13. Do not overload wall outlets and extensioncords as this can result in fire or electric shock. 14. Never push objects of any kind into thismonitor through cabinet slots, as they may touchdangerous voltage points or short out parts thatcould result in a fire or electric shock. Never spillliquid of any kind on the monitor. 15. Do not attempt to service thismonitor yourself, as opening orremoving covers may expose youto dangerous voltages or otherhazards. Refer all servicing to qualified service personnel. 16. Unplug this monitor from the wall outlet andrefer servicing to qualified service personnelunder the following conditions: a. When the power cord or plug is damaged orfrayed.b. If liquid has been spilled into the monitor. c. If the monitor has been exposed to rain orwater.d. If the monitor does not operate normally byfollowing the operating instructions. Adjust onlythose controls that are covered by the operatinginstructions, as improper adjustment of othercontrols may result in damage and will oftenrequire extensive work by a qualified technicianto restore normal operation. e. If the monitor has been dropped or the cabinethas been damaged. f. When the monitor exhibits a distinct change inperformance, this indicates a need for service. 17. When replacement parts arerequired be sure the servicetechnician has used replacementparts specified by the manufacturerthat have the same characteristics as the original part. Unauthorized substitutionsmay result in fire, electric shock, or otherhazards.18. Upon completion of any service or repairs tothis monitor, ask the service technician toperform routine safety checks to determine thatthe monitor is safe to operate. FEDERAL COMMUNICATIONS COMMISSION RADIO FREQUENCY INTERFERENCE STATEMENT NOTE : This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. Theselimits are designed to provide reasonable protection against harmfulinterference in a residential installation. This equipment generates, uses andcan radiate radio frequency energy and, if not installed and used inaccordance with the instructions, may cause harmful interference to radiocommunications. However, there is no guarantee that interference will notoccur in a particular installation. If this equipment does cause harmfulinterference to radio or television reception, which can be determined byturning the equipment off and on, the user is encouraged to try to correct theinterference by one or more of the following measures :- Reorient or relocate the receiving antenna.- Increase the separation between the equipment and receiver. - Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio or TV technician for help. CAUTION : Any changes or modifications not expressly approved by the party responsible for compliance could void the user ’ s authority to operate the equipment. CANADIAN NOTICEAVIS CANADIEN This Class B digital apparatus meets all requirements of the CanadianInterference-Causing Equipment Regulations.Cet appareil numérique de la Class B respecte toutes les exigences duRèglement sur le matériel brouilleur du Canada. Bitte lesen Sie alle diese Informationen, bevor Sie das Gerät in Betriebnehmen! Lesen Sie sich außerdem die Bedienungsanleitung komplett undsorgfältig durch, da nur in diesem Fall eine problemlose Inbetriebnahmeerwartet werden kann. • Achten Sie darauf, daß das Gerät nur in eine 230V Schuko-Steckdoseeingesteckt wird. • Die Steckdose sollte jederzeit frei zugänglich sein um bei einem evtl.auftretenden Notfall das Gerät schnell vom Netz zu trennen. • Achten Sie desweiteren darauf, daß die Netzanschlußleitung nichtmechanisch bean…
Text truncated - open the document above for the full version.
719BF BLOCK DIAGRAM
ID Label Sample & Location Information
File No. 03-IST-212/FB IST EMC LAB. Page 1 of 17 IST EMC Lab. San 21-8 Goan-Ri, Baekam-Myun, Yongin-Si, Kyunggi-Do, KOREA International - Tel : 82-31 - 333 - 4093. Fax : 82-31 - 333 - 4094. Domestic - Tel : 031 - 333 - 4093. Fax : 031 - 333 - 4094. IST EMC LAB. EMISSION TEST REPORT Test report file No. : 03-IST-212/FB Date of issue : Aug. 19, 2003 Model / Type No. : 719BF ■ Basic □ Alternate Kind of product Brand name Applicant Manufacturer License holder Address : 17” Monitor : LUCOMS : DAEWOO LUCOMS CO.,LTD. : WEIHAI DAEWOO ELECTRONICS CO.,LTD. : DAEWOO LUCOMS CO.,LTD. : Gaya-Venture B/D, 28-130, Yeongdeungpo-Dong, Yeongdeungpo-Gu, Seoul, Korea Test result according to the regulation(s) Positive Negative at page 3. This test report with appendix consists of 16 pages. The test result only responds to the tested sample. It is not allowed to copy this report even partly without the allowance of the Test Laboratory. This equipment is complied with the applicable technical standards as indicated in the measurement report and was tested in accordance with the measurement procedures specified in ANSI C63.4-1992. File No. 03-IST-212/FB IST EMC LAB. Page 2 of 17 IST EMC Lab. San 21-8 Goan-Ri, Baekam-Myun, Yongin-Si, Kyunggi-Do, KOREA International - Tel : 82-31 - 333 - 4093. Fax : 82-31 - 333 - 4094. Domestic - Tel : 031 - 333 - 4093. Fax : 031 - 333 - 4094. DIRECTORY A) Documentation. Page Directory Test regulations Information of Test Regulation Equipment under Test Test Conditions Test Result Measurement Uncertainty Test-setup Summary 2 3 3 4 5 ~ 6 7 8 9 ~ 11 17 B) Test Data. Conducted emissions (Mains) Radiated emissions : 150 kHz - 30 MHz : 30 MHz – 1 GHz 12 ~ 14 15 ~ 16 C) Appendix File No. 03-IST-212/FB IST EMC LAB. Page 3 of 17 IST EMC Lab. San 21-8 Goan-Ri, Baekam-Myun, Yongin-Si, Kyunggi-Do, KOREA International - Tel : 82-31 - 333 - 4093. Fax : 82-31 - 333 - 4094. Domestic - Tel : 031 - 333 - 4093. Fax : 031 - 333 - 4094. TEST REGULATIONS The tests were performed according to the following regulations ; ■ - FCC Part 15, Subpart B (Unintentional Radiators, Class B) Information of Test Laboratory IST EMC Lab. San 21-8 Goan-Ri, Baekam-Myun, Yongin-Si, Kyunggi-Do, Korea International - Tel : 82-31 - 333 - 4093. Fax : 82-31 - 333 - 4094. Domestic - Tel : 031 - 333 - 4093. Fax : 031 - 333 - 4094. File No. 03-IST-212/FB IST EMC LAB. Page 4 of 17 IST EMC Lab. San 21-8 Goan-Ri, Baekam-Myun, Yongin-Si, Kyunggi-Do, KOREA International - Tel : 82-31 - 333 - 4093. Fax : 82-31 - 333 - 4094. Domestic - Tel : 031 - 333 - 4093. Fax : 031 - 333 - 4094. EQUIPMENT UNDER TEST Equipment Description : CDT : 17-inch Flat Diagonal visible image area : 16.01-inch Dot Pitch : 0.24mm Synchronization : Vertical 50 ~ 150 Hz, Horizontal 30 ~ 70 kHz Plug and Play : VESA DDC Compatible Power Saving : EPA, VESA DPMS, Nutek Compliant Power Source : 100-240Vac, 50/60Hz (Free Voltage) Dimensions-(set with stand) : 419(W) x 407(H) x 419(D) mm Weight-unpacked : 35.2/16(1bs/Kg) Operating Temperature : 10 ~ 40 °C /50 ~ 104 °F EUT Type : Table-Top. Floor-Standing. Table-Top and Floor-Standing(Combination). Operation – mode of the E.U.T. : The equipment under test was operated during the measurement under following conditions : Standby. Operational Condition : Scrolling “H” characters under MS Windows, at test mode of 1280 X 1024, 60 Hz Configuration of the equipment under test : Following peripheral devices and interface cables were connected during the measurement : Equipment Type Brand Serial No. PC Brio BA600/550 HP SG01301176 Keyboard SK-2502C HP M000375059 PS/2 Mouse M-S48A HP LZA00850320 Serial Mouse M-S428 Logitech LCA53305547 Printer A0302384 Northern Telecom 26633S60168 Connecting Interface Cables : - Unshielded AC power cable : 1.8 m - Unshielded DC power cable : 1.5 m - Shielded monitor’s signal cable : 1.5 m - Shielded printer’s signal cable : 1.8 m File No. 03-IST-212/FB IST EMC LAB. Page 5 of 17 IST EMC Lab. San 21-8 Goan-Ri, Baekam-Myun, Yongin-Si, Kyunggi-Do, KOREA International - Tel : 82-31 - 333 - 4093. Fax : 82-31 - 333 - 4094. Domestic - Tel : 031 - 333 - 4093. Fax : 031 - 333 - 4094. TEST CONDITIONS The measurement of the conducted emissions (Interference voltage) was performed in a shielded room. Test location : Shielded room. No.1 Compact chamber 2 Used testing instruments : Name Type Manufacturer Calibration. Date Serial Number ESH 3 Test Receiver Rohde & Schwarz Jul. 22, 2003 892108/018 3725/2 LISN EMCO Jul. 23, 2003 9101-2068 KNW-407 LISN Hyup-Rip Jul. 23, 2003 8-883-10 ESH 3-Z2 Pulse Limiter Rohde & Schwarz Jul. 23, 2003 357.8810.52 Test - accessories : Type Manufacturer Aneroid Barometer Sato Hygrometer Sato Measurement Procedures : Conducted emissions measurments were made in accordance with ANSI C-63.4-1992, “Method of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz”. The measurement were performed over the frequency range of 0.15MHz to 30MHz using a 50 Ω /50uH LISN as the input transducer to an EMI/Field Intensity Meter. The measurements were made with the detector set for “Peak” amplitude within an IF bandwidth of 10kHz or for “quasi-peak” within a bandwidth of 9kHz. All used test-instruments as well as the test-accessories are calibrated regularly. File No. 03-IST-212/FB IST EMC LAB. Page 6 of 17 IST EMC Lab. San 21-8 Goan-Ri, Baekam-Myun, Yongin-Si, Kyunggi-Do, KOREA International - Tel : 82-31 - 333 - 4093. Fax : 82-31 - 333 - 4094. Domestic - Tel : 031 - 333 - 4093. Fax : 031 - 333 - 4094. The measurement of the radiated emissions (Electric field) in the frequency range from 30 MHz to 1GHz was performed in horizontal and vertical antenna polarization at a open-site which meet the site attenuation requirement of ANSI C63.4-1992 and a test distance of : Location : Open Site No. 1 Open Site No. 2 Open Site No. 3 Distance : 3 meters 10 meters Used testing instruments : Name Type Manufacturer Calibration. Date Serial …
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | - | - |

LCD Monitor
Equipment Class
JBP - Part 15 Class B Computing Device Peripheral
Personal Computer
Equipment Class
JBC - Part 15 Class B Computing Device/Personal Computer
19" LCD Monitor
Equipment Class
JBP - Part 15 Class B Computing Device Peripheral
17" LCD Monitor
Equipment Class
JBP - Part 15 Class B Computing Device Peripheral
17 " LCD Monitor
Equipment Class
JBP - Part 15 Class B Computing Device Peripheral