Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
1. Read all of these instructions. 2. Save these instructions for later use. 3. Unplug this monitor from the wall outlet before cleaning. Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning. 4. Do not use attachments not recommended by the monitor manufacturer as they may cause hazards. 5. Do not use this monitor near water, e.g., near a bathtub, washbowl, kitchen sink, or laundry tub, in a wet basement, or near a swimming pool, etc. 6. Do not place this monitor on an unstable cart, stand, or table. The monitor may fall, causing serious injury to a child or adult, and serious damage to the appliance. 7. Slots and openings in the cabinet and the back or bottom are provided for ventilation, to ensure reliable operation of the monitor, and to protect it from overheating. These openings must not be blocked or covered. The openings should never be blocked by placing the monitor on a bed, sofa, rug, or other similar surface. This monitor should never be placed near or over a radiator or heat register. This monitor should not be placed in a built-in installation such as a bookcase unless proper ventilation is provided. 8. This monitor should be operated only from the type of power source indicated on the marking label. If you are not sure of the power supplied to your home, consult your monitor dealer or local power company. 9. This monitor is equipped with a 3-wire grounding-type plug, That is, a plug having a third (grounding) pin. This plug will only fit into a grounding-type power outlet. This is a safety feature. If you are unable to insert the plug into the outlet, contact your electrician to replace your obsolete outlet. Do not defeat the purpose of the grounding-type plug. 10. Do not allow anything to rest on the power cord. Do not locate this monitor where the cord will be abused by people walking on it. 11. Follow all warnings and instructions marked on the monitor. IMPORTANT SAFEGUARDS 12. For added protection for this monitor during a lightning storm, or when it is left unattended and unused for long periods of time, unplug it from the wall outlet. This will prevent damage to the monitor and/or the computer due to lightning and power line surges. 13. Do not overload wall outlets and extension cords as this can result in fire or electric shock. 14. Never push objects of any kind into this monitor through cabinet slots, as they may touch dangerous voltage points or short out parts that could result in a fire or electric shock. Never spill liquid of any kind on the monitor. 15. Do not attempt to service this monitor yourself, as opening or removing covers may expose you to dangerous voltages or other hazards. Refer all servicing to qualified service personnel. 16. Unplug this monitor from the wall outlet and refer servicing to qualified service personnel under the following conditions: a. When the power cord or plug is damaged or frayed. b. If liquid has been spilled into the monitor. c. If the monitor has been exposed to rain or water. d. If the monitor does not operate normally by following the operating instructions. Adjust only those controls that are covered by the operating instructions, as improper adjustment of other controls may result in damage and will often require extensive work by a qualified technician to restore normal operation. e. If the monitor has been dropped or the cabinet has been damaged. f. When the monitor exhibits a distinct change in performance, this indicates a need for service. 17. When replacement parts are required be sure the service technician has used replacement parts specified by the manufacturer that have the same characteristics as the original part. Unauthorized substitutions may result in fire, electric shock, or other hazards. 18. Upon completion of any service or repairs to this monitor, ask the service technician to perform routine safety checks to determine that the monitor is safe to operate. WARNING: FOR CONTINUED SAFETY, REPLACE POWER ADAPTOR ONLY WITH MANUFACTURER'S RECOMMENDED MODELS FEDERAL COMMUNICATIONS COMMISSION RADIO FREQUENCY INTERFERENCE STATEMENT NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures : - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio or TV technician for help. CAUTION: Any changes or modifications not expressly approved by the party responsible for compliance could void the user ’s authority to operate the equipment. CANADIAN NOTICE AVIS CANADIEN This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la Class B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. European Union Notice Products with the CE Marking comply with both the EMC Directive (89/336/EEC) and the the Low Voltage Directive (73/23/EEC) issued by the Commission of the European Community. Compliance with these directives implies conformity to the following European Norms (in brackets are the equivalent international standards): •EN55022 (CISPR 22) - Electromagnetic Interference…
Text truncated - open the document above for the full version.
MAIN PCB 24C16 KEY CONTROL PCB PS25LV512 APA2068 L2200 BLOCK DIAGRAM 4xCCFL LCD PANEL MODULAR SPEAKER LCD CONTROLLER TSUMU58WJ-LF CRYSTAL 14.318MHz INVERTER UNIT D-SUB INVERTER ON/OFF DIMMING ADAPTER( 12 V) ANALOG R/G/BMAX1680x1050@60Hz R/G/B SIGNAL LVDS SIGNAL DATA I2C KEY H/VSYNC Panel 5V DIGITALINPUT DVI INPUT MAX1680x1050 DC IN AUDIOIN AUDIOOUT VOLUME CONTROL DVICONN
March 06, 2006 Compliance Certification Services Certification Division 561F Monterey Road Morgan Hill, CA 95037 To whom it may concern: We, the undersigned, hereby authorize IST Co., Ltd., to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by IST Co., Ltd. on our behalf shall have the same effect as acts of our own. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). In authorizing IST Co., Ltd. as our agent, we still recognize that we are responsible to: a) comply with the relevant provisions of the certification program; b) make all necessary arrangements for the conduct of the evaluation, including provision for examining documentation and access to all areas, records (including internal audit reports) and personnel for the purposes of evaluation (e.g. testing, inspection, assessment, surveillance, reassessment) and resolution of complaints; c) make claims regarding certification only in respect of the scope for which certification has been granted; d) do not use our product certification in such a manner as to bring the Certification Division into disrepute and not make any statement regarding our product certification which the Certification Division may consider misleading or unauthorized; e) upon suspension or cancellation of certification, discontinue use of all advertising matter that contains any reference thereto and return any certification documents as required by the Certification Division; f) use certification only to indicate the products are certified as being in conformity with specified standards; g) endeavor to ensure that no certificate or report nor any part thereof is used in a misleading manner; h) ensure that any reference to our product certification in communication media such as documents, brochures or advertising, complies with the requirements of the Certification Division; i) keep a record of all complaints made known to the us relating to the product’s compliance with requirements of the relevant standard and to make these records available to the Certification Division when requested; j) take appropriate action with respect to such complaints and any deficiencies found in products or services that affect compliance with the requirements for certification; k) document the actions taken. This authorization is valid until further written notice from the applicant. Sincerely Yours, Byung-Sun Hwang / Senior Engineer DAEWOO Lucoms co.,ltd.
ID Label Sample & Location Information
IST Co., Ltd EMC LABORATORY TEST REPORT NO. : 06-IST-0483 1 of 29 Certification of Compliance CFR 47 Part 15 Subpart B Test Report File No. : 06-IST-0483 Date of Issue : December 14, 2006 FCC ID : QZFL2200 Model(s) : L2200 ■ Basic □ Alternate Kind of Product : LCD MONITOR Applicant : DAEWOO Lucoms Co., Ltd. Address : 1201~4 Ace Techno Tower 5 th , 197-22 Guro-Dong, Guro-Gu, Seoul, Korea Manufacturer : DAEWOO Lucoms Co., Ltd. Address : 1201~4 Ace Techno Tower 5 th , 197-22 Guro-Dong, Guro-Gu, Seoul, Korea Test Result ■ Positive □ Negative Reviewed By Approved By Comment(s) - Investigations requested : Measurement to the relevant clauses of FCC rules and regulations Part 15 Subpart B – Unintentional Radiators, Class B. - The test report with appendix consists of 29 pages. - The test result only responds to the tested sample. - It is not allowed to copy this report even partly without the allowance of IST EMC Laboratory. - This equipment as for has been shown to be capable of continued compliance with the applicable technical standards as indicated in the measurement report and was tested in accordance with the measurement procedures specified in ANSI C63.4 2003. S.J.Cho / EMC Group Manager J.H.Lee / Chief IST Co., Ltd EMC LABORATORY TEST REPORT NO. : 06-IST-0483 2 of 29 TABLE OF CONTENTS Table of contents 2 Information of test laboratory, Environmental conditions, Power supply system used, Product information 3 Descriptions of test Conducted Emission 4 Radiated Emission 5 Measurement Uncertainty Calculations 6 Equipment Under Test 7 Test Set-Up (Figure) 8 Summary 9 ■ Test Conditions and Data – Emissions ◆ Conducted Emissions 0.15 MHz - 30 MHz Applicable Test Conditions / Data and Plots 10-12 ◆ Radiated Emissions 30 MHz - 1 GHz Applicable Test Conditions / Data and Plots 13-25 Appendix A. The Photos of Test Setup 26-27 B. The Photos of Equipment Under Test 28-29 Note: IST Co., Ltd EMC LABORATORY TEST REPORT NO. : 06-IST-0483 3 of 29 INFORMATIONS OF TEST LABORATORY EMC LABORATORY of IST Co., Ltd. (FCC Filing Lab.) 80, Jeil-Ri, Yangji-Myun, Yongin-City Kyonggi-Do, 449-860, Korea TEL : +82 31 333 9018 FAX : +82 31 333 9019 ENVIRONMENTAL CONDITIONS Temperature 6.5 °C Humidity 34 % Atmospheric pressure 1014 mbar POWER SUPPLY SYSTEM USED Power supply system AC 120V, 60Hz (Refer to the product information) PRODUCT INFORMATION Size 22-inch (55.88cm) diagonal Pixel Pitch 0.282(H)mm x 0.282(V)mm 160°(Right/Left)Viewing Angle 160°(up) 60°(down) Brightness 300cd/m2 brightness (typ) Response Time 5msec Color Filter RGB vertical stripe Panel Brand LG.PHILIPS Synchronization Horizontal 30 - 80KHz Vertical 56 - 77 Hz Video Bandwidth 165MHz Max Resolution 1680 x 1050@ 60Hz Optimal Resolution 1680 x 1050 @ 60Hz Colors 16.7 M Colors Display Area 473.76(H)mm x 296.1(V)mm PC Input Signal Sync H/V separate (TTL) Video 15 pin mini D-sub(Analog RGB) DVI-D(Optional) Speaker Max. Output Left 3W + Right 3W LI SHIN INTENATIONAL ENTERPRISE CORP. / China Model Name : LSE9901B260 Input : 100~240V ,50~60 Hz 1.5A AC/DC Adaptor Output : 12V 5A Power Consumption 40 W Dimension-W x H x D With Stand 523(W) x 405(H) x 156(D) mm Without Stand 523(W) x 367(H) x 66(D) mm Weight-net/gross 6.5Kg / 8.7Kg (14.3 lbs/19.2 lbs) Operating Temperature 10 ~ 40°C /50 ~ 104°F - EMC suppression device is not used during the test . - Please refer to user’s manual. IST Co., Ltd EMC LABORATORY TEST REPORT NO. : 06-IST-0483 4 of 29 < Concept Drawing > 215 >150 >40 80 Receiver EUT LISN 80 ≥ 80 80 40 ≥ 80 Measuring apparatus Mains Filter Mains Rear side Equipment under test Coaxial cable Artificial mains networ k Screened room Non-metallic support 80 DESCRIPTIONS OF TEST Conducted Emissions: The measurement were performed over the frequency range of 0.15 MHz to 30 MHz using a ESH2-Z5 LISN as the input transducer to a Spectrum Analyzer or a Field Intensity Meter. The measurements were made with the detector set for "Peak" amplitude within a bandwidth of 10 KHz or for "quasi-peak" & “Average” within a bandwidth of 9 KHz. - Procedure of Test The line-conducted facility is located inside a shielded room No.1. A 1 m X 1.5 m wooden table 80 cm height is placed 40 cm away from the vertical wall and 1.5m away from the other wall of the shielded room. The ESCS30 and ESH2-Z5 LISN are bonded to bottom of the shielded room. The EUT is located on the wooden table with distance more than 80cm from the LISN and powered from the ESH2-Z5 LISN .The peripheral equipment is powered from the other LISN. Power to the LISNs are filtered by a noise cut power line filters. All electrical cables are shielded by braided tinned steel tubing with inner φ 1.2 cm. If the EUT is a DC-powered device, power will be derived from the source power supply it normally will be powered from and this supply lines will be connected to the ESH2-Z5 LISN. All interconnecting cables more than 1m were shortened by non-inductive bundling to a 1m length. Sufficient time for the EUT, support equipment, and test equipment was allowed in order for them to warm up to their normal operating conditions. The RF output of the LISN was connected to the ESCS30 receiver to determine the frequency producing the maximum emission from the EUT. The frequency producing the maximum level was reexamined using Quasi-Peak mode by manual measurement, after scanned by automatic Peak mode for frequency range from 0.15 to 30 MHz. The bandwidth of the receiver was set to 10 kHz. The EUT, peripheral equipment, and interconnecting cables were arranged and manipulated to maximize each EME emission. < Side View > IST Co., Ltd EMC LABORATORY TEST REPORT NO. : 06-IST-0483 5 of 29 DESCRIPTION OF TEST Radiated Emissions: The measurement was performed over the frequency range of 30MHz to 1GHz using antenna as the input transducer to a Spectrum analyzer or a Field Intensity Meter. The measurement was made with the detector set for "quasi-peak" within a bandwidth of 120 KHz. - Procedure of Test Preliminary measurements were made at 3…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | - | - |

Personal Computer
Equipment Class
JBC - Part 15 Class B Computing Device/Personal Computer
19" LCD Monitor
Equipment Class
JBP - Part 15 Class B Computing Device Peripheral
17" LCD Monitor
Equipment Class
JBP - Part 15 Class B Computing Device Peripheral
17 " LCD Monitor
Equipment Class
JBP - Part 15 Class B Computing Device Peripheral
17" Color Monitor
Equipment Class
JBP - Part 15 Class B Computing Device Peripheral