FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. XceedID Corporation/
  3. R2LXF2210KEY

R2LXF2210KEYAccess Control Reader, 13.56 MHz Keypad Midrange

XceedID Corporation
Access Control Reader, 13.56 MHz Keypad Midrange - FCC ID R2LXF2210KEY - XceedID Corporation
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Dec 06, 2007
Application Purpose
Original Equipment
Date of Application
Nov 26, 2007
Equipment Note
Access Control Reader, 13.56 MHz Keypad Midrange
Frequency Range
13.56000000 - 13.56000000
Company
XceedID Corporation
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

XceedID : Document No: 0469-01; Issue No. 1; 4/12/2007 INSTALLATION SHEET XF2200/XF2210 PARTS LIST: • 1 - Installation Sheet • 1 - Mounting Plate • 1 - Potted Reader Assembly • 1 - Cover • 2 - Mounting Screws • 1 – Cover Assembly Screw Removal: 1. Remove unit from box. Mounting the Reader: 1. Determine an appropriate mounting position on a single gang box or wall. Be sure to account for any applicable ADA height requirements. 2. For a single gang box mount, attach the back-plate to the holes in the single gang box using the screws provided. 3. For a wall mount, drill two mounting holes between 2.5” (63.5 mm) and 3.5” (88.9 mm) apart on the mounting surface. Drill holes to make a hole on the wall about the same size as the rectangular opening in the mounting plate ( 1.4” x .53” or 35.6 mm x 13.5 mm) for the connector and cable wire connection to the host. 4. Connect the mounting plate to the wall using the screws provided. 5. Wire the unit according to the color code chart below ensuring that all connections are made through the rectangular hole in the mounting plate. 6. Hook the top of the potted case assembly to the top of the mounting plate. 7. Swivel the unit down into place and snap the cover over the potted reader assembly. 8. Install the screw from the bottom to fix the cover to the potted case to the mounting plate. Cable Connections: 1. XceedID XF2200/XF2210 readers are supplied with a 12 conductor cable that contains a connector on one end and tinned wires on the other end. Connect these wires to the host/panel being careful to match the color of each wire with the chart shown below. Green = Data 0 White = Data 1 Orange = Green LED Brown = Red LED Red = Power +DC (5-16 VDC) Black = Ground Tan = Tamper Output Pink = Card Present Yellow = Beeper Gray = Not Used Purple = Not Used Blue = Not Used XceedID : Document No: 0469-01; Issue No. 1; 4/12/2007 2. Use a DC power source between 5 volts and 16 volts. 3. Be sure the reader is properly grounded by attaching the ground wire to an earth ground connection at the power supply or panel end of the cable. Testing the Reader: 1. Power up the reader. The LED will light followed by a beeper tone. This indicates that the reader is ready. 2. Present a proper card or token programmed to operate the reader and a green LED flash will indicate successful operation. Note that a red flash could simply indicate an incorrect match or miss-programmed card/token rather than a faulty reader installation. Additional Notes: • The voltage specification for these products is 5 volts to 16 volts. • Typical cable gauge ranges from 18 to 22 gauge. Check with your cable supplier to determine the best choice for your application and installation distance . Specifications: • Power Supply: DC • Voltage Range: 5 – 16VDC • Temperature Range: -35C to +65C (-31F to 149F) • Card Read Distance: Up to 4.5” (115 mm) – Distance can vary widely depending on installation conditions and credential type. • Cable Distance to Panel in Wiegand mode: o 500 ft. maximum @ 22 awg for 12 volt supply. o 200 ft. maximum @ 22 awg for 5 volt supply. • Information Output: Wiegand • Regulatory Approvals and Standards UL 294 ISO15693 ISO14443A Europe: CE Listed. Federal Communications Statement: The FCC requires the following statement for your information: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This reader utilizes and radio frequency energy and has been tested and complies with the limits of FCC testing. Changes, modifications or disregard of proper installation instructions not expressly approved by XceedID Corporation is strictly prohibited by the FCC and could void the user’s authority to operate the equipment. For Canadian Users: This unit has been tested and meets all applicable Industry of Canada technical specifications. • This device may not cause radio frequency interference. • This device must accept radio frequency interference. In the unlikely event interference occurs, please contact the manufacturer.

Cover Letter(s)

112 North Rubey Drive, Suite 100, Golden, CO 80403 Tel: 303-273-9930 Fax: 303-273-9937 Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 10/5/2007 Gentlemen: This letter is to comply with Sections 0.457 and 0.459 pertaining to confidential material. XceedID Corporation would like the documents regarding schematics, block diagrams and operational descriptions for this submission for FCC ID: R2LXF2210KEY to be kept confidential. The information submitted provides XceedID a competitive advantage in the market. The submitted material also contains trade secrets or technical data, which would customarily be guarded from competitors. We do NOT want these documents to be accessible to the general public. Sincerely, Michael T. Conlin VP Engineering XceedID Corporation

Cover Letter(s)

CKC Certifications Se rvices - Confidential E07-000094-FCC EP04 8 of 12 Rev 10 Appendix A Non-Conformities for US Radio Equipment Authorization Non-Conformities FCC ID: R2LXF2210KEY (CKC CS Ref # E07-000094-FCC-01) The items listed below represent requests for information following review of this application for certification under United S tates (FCC) regulations. . Further question may arise pending review of responses to these items. OK # Non-Conformity or Comment Submit ted Response Respondent / Date of Response x 1 Forth paragraph of the provided circuit description addresses the operation of XF21X0 readers which may not be applicable to XF2200 and XF2210 family of access control readers. Please prov ide revised circuit description. Revised operational description with correct model number was provided. 11/20/07 CKC Labs x 2 The device incorporated the ability to communicate with auxiliary equipment using Wiegand or RS485 protocols, however the test set does not indicate the data cable is connected to any auxiliary device. Please justify the setup. TCB Committee clarification: the setup meets ANSI 63.4 requirement. 11/20/07 Manufacturer clarifies the open circuit is worse case loading for the product. 10/24/07 TCB Committee x 3 The device incorporated the ability to communicate with auxiliary equipment using Wiegand or RS485 protocols, however the test set does not indicate the data communication functionalities are exercised. Please justify. 11/20/07 Manufacturer clarifies the open circuit is worse case loading for the product. 11/20/07 CKC Labs. x 4 The device description indicates the product is capable of receiving signal from a passive RFID tag, however, the test report does not indicate the device was exercised by receiving a transpond er signal during the test. Please explain. Not required. 10/24/07 TCB Committee x 5 Page 11, 13, 15, 17, 31, 32, 33, 35, 37, 39,.The provided radiated emission data sheets include a transducer legend T1 cable sited 9k-1GHz . However, the calibration of this transducer cannot be validated. Please provide calibration date of the transducer used. 11/20/07 Rephrase: please provide a test report with transducer T1, cable site D 9k-1GHz, listed in the test equipment table with appropriate calibration and calibration due dates. Pages in questions are Page 11, 13, 15, 17, 31, 32, 33, CKC Labs provided revised test report . however the provided clarification did not meet the report requirement. 11/21/07: Revised test report with calibration and cal due date of transducer T1. 11/20/07 CKC Labs 11/21/07 CKC labs CKC Certifications Se rvices - Confidential E07-000094-FCC EP04 9 of 12 Rev 10 35, 37, 39 CKClabs 6 The installation manual indicates the device operates in the range of 5 – 16 Vdc. However, page 52 of the test report shows the voltage variation is performed at +-15 % of 12V instead of -15% of 5 V and +15% of 16V. . Please provided justification to fulfill 15.31(e) requirement of “shall be performed with the supply voltage varied between 85% and 115% of the nominal rated supply voltage.” TCB Committee clar ification: The Voltage variation pertains to AC power. 11/20/07: declared nominal operational voltage is 12Vdc. 10/24/07 TCB Committee x 7 Through out the report, the test co ndition indicates a cable with ferrite installed was used , however the installation manual described the cable as “ a 12 conductor cable that contains a connector on one end and tinned wires on the other end.” Please provide an updated users manual incorporating an y necessary statements in accordance with 15.27. Manufacturer clarified the cable supplied with the product contains a built in ferrite. 11/20/07 CKC Labs x 8 The FCC statement in the installation manual does reference to Class B device, Please provide an updated user s manual incorporating the appropriate users manual statement in accordance w ith 15.105. TCB Committee clar ification: The statement is only applicable to Part15B computer peripheral. 10/24/07 TCB Committee x 9 The return frequency of the transponder/RFID tag is not identified in any provided document. Pl ease provide the return frequency of the transponder. Manufacturer clarification: Return frequencies are 13.56, 424kHz and 848 kHz. 11/20/07 CKC Labs x 10 The provided occupied bandwidth was measured with a RBW 0f 100Hz, However, ANSI 63.4, 2003 . Section 13.1.7.specifies a minimum RBW of 1kHz . Please justify the accuracy of occupied bandwidth measurement using RBW of 100Hz. Rephrase 101907 “The occupied bandwidth was tested using a bandwidth lower than prescribed by ANSI C63.4, please clarify whether the amplitude was unaffected by the decrease in RBW or provide updated measurements as necessary.” TCB Committee clar ification: The RBW used meets requirement. 10/24/07 TCB Committee NOTE: Since this application E07-000094, employs the test report FC07-061.pdf which is identical to test report for applicati on E07-00092, the technical non conformity listed is the same as non-conformity found in application E07-00092. CKC Certifications Se rvices - Confidential E07-000094-FCC EP04 10 of 12 Rev 10 The items indicated above must be submitted before processing can continue on the referenced application. Failure to provide t he requested information within 60 days may result in application dismissal pursuant to Section 2.917(c) and forfeiture of the filing fee pursuant to Se ction 1.1106. ---CKC CS SECTION--- ---Information below this line is for CKC CS Evaluators only--- CKCCS Note : Additions to non-conformities may be listed in a separate ta ble for convenience. When separated, the non-conformity referen ce serial number (NN) is incremented using in the following format reference # E07-000094-FCC-NN .

External Photos

Front XF2210S Front XF2200W Back XF2210S Back XF2200W Top XF2210S Top XF2200W Bottom XF2210S Bottom XF2200W Left XF2210S Left XF2200W Right XF2210S Right XF2200W

ID Label/Location Info

ID Label & Location XF2210 Label Location XF2210S4 XF2210W

Internal Photos

Back Overall XF2210S Back Overall XF2200W Back Potted XF2210S Back Potted XF2200W Front Chassis XF2210S Front Chassis XF2200W PCB Front XF2210S PCB Front XF2200W PCB Back XF2210S PCB Back XF2200W Ferrite Cable with added Ferrite

Test Report

Page 1 of 52 Report No.: FC07-061 XCEEDID TEST REPORT FOR THE SMART CARD READERS, XF2210S(T725S), XF2210W(T725W), XF2200W(T720W) & XF2200S(T720S) FCC PART 15 SUBPART C SECTIONS 15.225, 15.207 & 15.209 TESTING DATE OF ISSUE: AUGUST 14, 2007 PREPARED FOR: XceedID 112 N. Rubey Drive, Suite 100 Golden, CO 80403 PREPARED BY: Mary Ellen Clayton CKC Laboratories, Inc. 5046 Sierra Pines Drive Mariposa, CA 95338 P.O. No.: 62745 W.O. No.: 86828 Date of test:August 6-10, 2007 Report No.: FC07-061 This report contains a total of 52 pages and may be reproduced in full only. Partial reproduction may only be done with the written consent of CKC Laboratories, Inc. The results in this report apply only to the items tested, as identified herein. Page 2 of 52 Report No.: FC07-061 TABLE OF CONTENTS Administrative Information .............................................................................................3 Approvals .........................................................................................................................3 FCC to Canada Standard Correlation Matrix...................................................................4 Conditions During Testing...............................................................................................4 FCC 15.31(m) Number Of Channels ...............................................................................5 FCC 15.33(a). Frequency Ranges Tested .......................................................................5 FCC 15.35 Analyzer Bandwidth Settings ........................................................................5 FCC 15.203 Antenna Requirements ................................................................................5 EUT Operating Frequency ...............................................................................................5 Temperature And Humidity During Testing....................................................................5 Equipment Under Test (EUT) Description ......................................................................6 Equipment Under Test .....................................................................................................6 Peripheral Devices ...........................................................................................................6 Report of Emissions Measurements.................................................................................7 Testing Parameters...............................................................................................7 FCC 15.109 Radiated Emissions .........................................................................9 FCC 15.207 Conducted Emissions ......................................................................19 FCC 15.209 Radiated Emissions .........................................................................29 FCC 15.225 Radiated Emissions .........................................................................41 Occupied Bandwidth............................................................................................45 Emissions Mask ...................................................................................................48 Frequency Stability ..............................................................................................51 Page 3 of 52 Report No.: FC07-061 ADMINISTRATIVE INFORMATION DATE OF TEST: August 6-10, 2007 DATE OF RECEIPT: August 6, 2007 REPRESENTATIVE: Mike Conlin MANUFACTURER: XceedID 112 N. Rubey Drive, Suite 100 Golden, CO 80403 TEST LOCATION: CKC Laboratories, Inc. 5046 Sierra Pines Drive Mariposa, CA 95338 TEST METHOD: ANSI C63.4 (2003) PURPOSE OF TEST: To perform the testing of the Smart Card Readers, XF2210S(T725S), XF2210W(T725W), XF2200W(T720W) & XF2200S(T720S) with the requirements for FCC Part 15 Subpart C Sections 15.225, 15.207 & 15.209 devices. APPROVALS Steve Behm, Director of Engineering Services QUALITY ASSURANCE: TEST PERSONNEL: Joyce Walker, Quality Assurance Administrative Manager Mike Wilkinson, EMC Engineer/Lab Manager Page 4 of 52 Report No.: FC07-061 FCC TO CANADA STANDARD CORRELATION MATRIX Canadian Standard Canadian Section FCC Standard FCC Section Test Description RSS GEN 7.1.4 47CFR 15.203 Antenna Connector Requirements RSS GEN 7.2.1 47CFR 15.35(c) Pulsed Operation RSS GEN 7.2.2 47CFR 15.207 AC Mains Conducted Emissions Requirement RSS 210 2.1 47CFR 15.215(c) Frequency Stability Recommendation RSS 210 2.2 47CFR 15.205 Restricted Bands of Operation RSS 210 2.6 47CFR 15.209 General Radiated Emissions Requirement RSS 210 A2.6 47CFR 15.225(a-c) Fundamental and Emissions Mask Requirements RSS 210 A2.6 NA NA ±150kHz to ±450kHz Emissions Requirement RSS 210 A2.6 47CFR 15.225(d) Out of band emissions RSS 210 A2.6 47CFR 15.225(e) Carrier Stability IC 3082A-1 784962 Site File No. CONDITIONS DURING TESTING Cable is XceedID ferrited version with an added ferrite (Fair-Rite p/n 2643625202). Page 5 of 52 Report No.: FC07-061 FCC 15.31(m) Number Of Channels This device operates on a single channel. FCC 15.33(a) Frequency Ranges Tested 15.109 Radiated Emissions: 30 MHz – 1000 MHz 15.207 Conducted Emissions: 150 kHz – 30 MHz 15.209 Radiated Emissions: 9 kHz – 1000 MHz 15.225 Radiated Emissions: Carrier FCC SECTION 15.35: ANALYZER BANDWIDTH SETTINGS PER FREQUENCY RANGE TEST BEGINNING FREQUENCY ENDING FREQUENCY BANDWIDTH SETTING CONDUCTED EMISSIONS 150 kHz 30 MHz 9 kHz RADIATED EMISSIONS 9 kHz 150 kHz 200 Hz RADIATED EMISSIONS 150 kHz 30 MHz 9 kHz RADIATED EMISSIONS 30 MHz 1000 MHz 120 kHz RADIATED EMISSIONS 1000 MHz >1 GHz 1 MHz FCC 15.203 Antenna Requirements The antenna is an integral part of the EUT and is non-removable; therefore the EUT complies with Section 15.203 of the FCC rules. EUT Operating Frequency The EUT was operating at 13.56 MHz. Temperature And Humidity During Testing The temperature during testing was within +15°C and + 35°C. The relative humidity was between 20% and 75%. Page 6 of 52 Report No.: FC07-061 EQUIPMENT …

Text truncated - open the document above for the full version.

Test Setup Photos

RADIATED EMISSIONS Test Setup Photos XF2210S-W XF2210S-W XF2200S-W XF2200S-W CONDUCTED EMISSIONS Test Setup Photos XF2210S-W XF2210S-W XF2200S-W XF2200S-W FREQUENCY STABILITY Test Setup Photos

Contact Information

Applicant

Dan Munson(Senior Electronics Engineering Manager)
[email protected]303-640-2667Fax: 303-273-9937

Technical Contact

CKC Laboratories, Inc.Mary Ellen Clayton
[email protected]209-966-5240

5046 Sierra Pines Dr. · Mariposa, California · United States

Test Firm

CKC Laboratories, Inc.Steve Behm
[email protected]209-966-5240Fax: 866 779 9776

Technical Specifications

#Rule PartsFrequency RangePower Output
115C13.56 MHz - 13.56 MHz-
Confidentiality
Long Term

Other Applications from XceedID Corporation

The MT20w is a Credential Enrollment Reader for access control systems. - FCC ID R2LMT20W - XceedID Corporation
R2LMT20W

The MT20w is a Credential Enrollment Reader for access control systems.

Oct 06, 2015

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
The MT20 is a Credential Enrollment Reader for access control systems. - FCC ID R2LMT20 - XceedID Corporation
R2LMT20

The MT20 is a Credential Enrollment Reader for access control systems.

Nov 20, 2014

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Credential Access Reader - FCC ID R2LSSU89 - XceedID Corporation
R2LSSU89

Credential Access Reader

Jul 12, 2012

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified
Access Control Reader - FCC ID R2LMT11-485 - XceedID Corporation
R2LMT11-485

Access Control Reader

Jun 11, 2012

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Access Control Reader - FCC ID R2LMTK15-485 - XceedID Corporation
R2LMTK15-485

Access Control Reader

Jun 11, 2012

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified