Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
PremierWave ® XC User Guide Part Number 500-598 Revision B Oct 2011 Copyright & Trademark © 2011 Lantronix. All rights reserved. No part of the contents of this book may be transmitted or reproduced in any form or by any means without the written permission of Lantronix. Printed in the United States of America. Ethernet is a trademark of XEROX Corporation. Windows is a trademark of Microsoft Corporation. Linux is a registered trademark of Linus Torvalds. Warranty For details on the Lantronix warranty replacement policy, please go to our web site at www.lantronix.com/support/warranty . Contacts Lantronix Corporate Headquarters 167 Technology Drive Irvine, CA 92618, USA Phone:949-453-3990 Fax:949-450-7249 Technical Support Online:w ww.lantronix.com/support Sales Offices For a current list of our domestic and international sales offices, go to the Lantronix web site at w ww.lantronix.com/about/contact . Disclaimer This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to pro-vide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not in-stalled and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/ TV technician for help. PremierWave XC User Guide2 FCC Part 15.21 Statement Changes or modifications made to this equipment not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. FCC RF Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. End users must follow the specific operating instructions for satisfying RF exposure compliance. This transmitter must be at least 20 cm from the user and must not be co-located or operating in conjunction with any other antenna or transmitter. The information in this guide may change without notice. The manufacturer assumes no responsibility for any errors that may appear in this guide. Revision History DateRev.Comments Aug 2011AInitial Document. Oct 2011BUpdated for 7.2.0.0R23 PremierWave XC User Guide3 Table of Contents Copyright & Trademark __________________________________________________________2 Warranty _____________________________________________________________________2 Contacts _____________________________________________________________________2 Disclaimer ____________________________________________________________________2 Revision History _______________________________________________________________3 1: Using This Guide 11 Purpose and Audience _________________________________________________________11 Summary of Chapters __________________________________________________________11 Additional Documentation _______________________________________________________12 2: Introduction 13 Key Features_________________________________________________________________13 Applications__________________________________________________________________14 Protocol Support_______________________________________________________________14 Troubleshooting Capabilities_____________________________________________________14 Configuration Methods__________________________________________________________15 Addresses and Port Numbers____________________________________________________15 Hardware Address__________________________________________________________15 IP Address________________________________________________________________15 Port Numbers______________________________________________________________15 Product Information Label________________________________________________________16 3: Installation of PremierWave XC 17 Package Contents______________________________________________________________17 User-Supplied Items____________________________________________________________17 Hardware Components__________________________________________________________18 Back Panel_________________________________________________________________19 Reset Button________________________________________________________________20 Top Panel__________________________________________________________________20 PremierWave XC User Guide4 Side Panel_________________________________________________________________22 Bottom Panel_______________________________________________________________23 Installing The PremierWave XC___________________________________________________23 4: Using DeviceInstaller 26 Accessing PremierWave XC using DeviceInstaller_____________________________________26 Device Detail Summary__________________________________________________________27 5: Configuration Using Web Manager 29 Accessing Web Manager_________________________________________________________29 Device Status Page__________________________________________________________30 Web Manager Page Components__________________________________________________31 Navigating the Web Manager______________________________________________________33 6: Network Settings 35 Network 1 Interface Settings______________________________________________________36 To Configure Network 1 Interface Settings________________________________________36 To View Network 1 Interface Status______________________________________________37 Networ…
Text truncated - open the document above for the full version.
UL 60950-1 LABEL,AGENCY,PW XC ART BY: DATE: REVISION: DATE: 100% TITLE: SCALE: METAL: MATERIAL: COLOR: ADHESION: 2 colors: Black, PMS Cool Gray 1 NEW PART NUMBER: PXC2102G2-01 OLD PART NUMBER: STATUS: LANTRONIX 15353 BARRANCA PARKWAY IRVINE, CA 92618 (949) 453-3990 5 Mil Lexan N/A 3M# 467 unknown A. New Label 5/19/11 COMMENTS: PremierWave XC PXC2102G2-01 I.T.E Equipment This device complies with Part 15, Part 22 and 24 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference (2) this device must accept any interference received, including interference that may cause undesired operation. 9-30VDC 3.0 Watt Max. 1588 FCC ID: R68PWXC 45 mm 62 mm R 2.0mm 5/19/11
Internal photos
China Telecommunication Technology Labs. ® MPE REPORT REPORT NUMBER: I11GC0275-FCC-MPE-2 ON Type of Equipment: PremierWave XC Type of Designation: PremierWave XC Manufacturer: iWOW Connections Pte Ltd ACCORDING TO FCC CFR 47, Part 2, FREQUENCY ALLOCATIONS AND RADIO TREATY MATTERS; GENERAL RULES AND REGULATIONS Section 2.1091 Radiofrequency radiation exposure evaluation: mobile devices China Telecommunication Technology Labs. Month date, year Mar, 6, 2012 Signature He Guili Director FCC Part 2.1091 Equipment: PremierWave XC REPORT NO.: I11GC0275-FCC-MPE-2 Address:11 YUE TAN NAN JIE, BEIJING, P.R.C,100045 Tel:+86 10 68094053 FAX:+86 10 68011404 Web:http://www.chinattl.com Page 2 of 13 China Telecommunication Technology Labs. ® FCC ID: R68PWXC Report Date: 2012-3-6 Test Firm Name: China Telecommunication Technology Labs Registration Number: 840587 Statement The report is a Maximum Permissible Exposure evaluation report according to FCC CFR part 2.1091. FCC Part 2.1091 Equipment: PremierWave XC REPORT NO.: I11GC0275-FCC-MPE-2 Address:11 YUE TAN NAN JIE, BEIJING, P.R.C,100045 Tel:+86 10 68094053 FAX:+86 10 68011404 Web:http://www.chinattl.com Page 3 of 13 China Telecommunication Technology Labs. ® CONTENTS 1 GENERAL INFORMATION ....................................................................... 4 1.1 NOTES ................................................................................................ 4 1.2 EDITOR ............................................................................................... 5 1.3 TESTING LABORATORY INFORMATION ............................................................. 6 1.4 DETAILS OF APPLICANT OR MANUFACTURER ...................................................... 7 2 TEST ITEM ............................................................................................. 8 2.1 GENERAL INFORMATION ............................................................................ 8 2.2 OUTLINE OF EUT .................................................................................... 8 2.3 MODIFICATIONS INCORPORATED IN EUT ......................................................... 8 2.4 EQUIPMENT CONFIGURATION ...................................................................... 8 2.5 OTHER INFORMATION ............................................................................... 8 3 SUMMARY OF RESULTS .......................................................................... 9 4 RESULTS .............................................................................................. 10 4.1 APPLICABLE STANDARDS ......................................................................... 10 4.2 CONDUCTED RF POWER OUTPUT ................................................................ 11 4.3 CALCULATION INFOMATION ...................................................................... 11 4.4 EVALUATION RESULT .............................................................................. 11 FCC Part 2.1091 Equipment: PremierWave XC REPORT NO.: I11GC0275-FCC-MPE-2 Address:11 YUE TAN NAN JIE, BEIJING, P.R.C,100045 Tel:+86 10 68094053 FAX:+86 10 68011404 Web:http://www.chinattl.com Page 4 of 13 China Telecommunication Technology Labs. ® 1 General Information 1.1 Notes The MPE report was carried out on a sample equipment to demonstrate limited compliance with FCC CFR 47 Part 2.1091. The test results of this report relate exclusively to the item(s) tested as specified in section 2. China Telecommunication Technology Labs.(CTTL) authorizes the applicant or manufacturer (see section 1.4) to reproduce this report provided, and the MPE report may only be reproduced or published in full. Reproduction or publication of extracts from the report requires the prior written approval of CTTL Mr. He Guili. Any use which a third party makes of this report, or any reliance on or decisions to be made based on it, are the responsibility of such third parties. CTTL accepts no responsibility for damages, if any, suffered by any third party as a result of decisions made or actions based on this report. FCC Part 2.1091 Equipment: PremierWave XC REPORT NO.: I11GC0275-FCC-MPE-2 Address:11 YUE TAN NAN JIE, BEIJING, P.R.C,100045 Tel:+86 10 68094053 FAX:+86 10 68011404 Web:http://www.chinattl.com Page 5 of 13 China Telecommunication Technology Labs. ® 1.2 Editor Editor of this test report: Name: Li Guoqing Position: Engineer Department: Department of EMC test Date: 2012-3-6 Signature: Technical responsibility for area of testing: Name: Zou Dongyi Position: Manager Department: Department of EMC test Date: 2012-3-6 Signature: FCC Part 2.1091 Equipment: PremierWave XC REPORT NO.: I11GC0275-FCC-MPE-2 Address:11 YUE TAN NAN JIE, BEIJING, P.R.C,100045 Tel:+86 10 68094053 FAX:+86 10 68011404 Web:http://www.chinattl.com Page 6 of 13 China Telecommunication Technology Labs. ® 1.3 Testing Laboratory information 1.3.1 Location Name: China Telecommunication Technology Labs. Address: No. 11, Yue Tan Nan Jie, Xi Cheng District BEIJING P. R. CHINA, 100045 Tel: +86 10 68094053 Fax: +86 10 68011404 Email: [email protected] 1.3.2 Details of accreditation status Accredited by: DATech Deutsche Akkreditierungsstelle Technik in der TGA GmbH(German Accreditation Body for Technology in the TGA) Lab number: DA7130 DAR Registration number: DAT-PL-162/04-01 Standard: ISO/IEC 17025:2005 1.3.3 Test location, where different from section 1.3.1 Name: ------ Address: ------ FCC Part 2.1091 Equipment: PremierWave XC REPORT NO.: I11GC0275-FCC-MPE-2 Address:11 YUE TAN NAN JIE, BEIJING, P.R.C,100045 Tel:+86 10 68094053 FAX:+86 10 68011404 Web:http://www.chinattl.com Page 7 of 13 China Telecommunication Technology Labs. ® 1.4 Details of applicant or manufacturer 1.4.1 Applicant Name: Lantronix, Inc. Address: 167 Technology Drive. Irvine, CA 92618 USA Country: USA Telephone: 949-453-7133 Fax: 949-453-3995 Contact: Walton Leung Telephone: 949-453-7133 Email: [email protected] 1.4.2 Manufacturer (if different from applicant in se…
Text truncated - open the document above for the full version.
China Telecommunication Technology Labs. ® TEST REPORT REPORT NUMBER: I11GC0275-FCC-RF-2 ON Type of Equipment: PremierWave XC Type of Designation: PremierWave XC Manufacturer: iWOW Connections Pte Ltd ACCORDING TO FCC CFR Part 2, FREQUENCY ALLOCATIONS AND RADIO TREATY MATTERS; GENERAL RULES AND REGULATIONS. Oct, 1, 2011 PART 22, PUBLIC MOBILE SERVICES. Oct 1, 2011 PART 24, PERSONAL COMMUNICATIONS SERVICES, Oct 1, 2011 China Telecommunication Technology Labs. Month date, year Mar 6, 2012 Signature He Guili Director FCC Parts 2, 22, 24 Equipment: PremierWave XC REPORT NO.: I11GC0275-FCC-RF-2 Address:11 YUE TAN NAN JIE, BEIJING, P.R.C,100045 Tel:+86 10 68094053 FAX:+86 10 68011404 Web:http://www.chinattl.com Page 2 of 45 China Telecommunication Technology Labs. ® FCC ID: R68PWXC Report Date: 2012-3-6 Test Firm Name: China Telecommunication Technology Labs Registration Number: 840587 Statement The measurements shown in this report were made in accordance with the procedures described on test pages. All reported tests were carried out on a sample equipment to demonstrate limited compliance with FCC CFR 47 Parts 2, 22 and 24. The sample tested was found to comply with the requirements defined in the applied rules. FCC Parts 2, 22, 24 Equipment: PremierWave XC REPORT NO.: I11GC0275-FCC-RF-2 Address:11 YUE TAN NAN JIE, BEIJING, P.R.C,100045 Tel:+86 10 68094053 FAX:+86 10 68011404 Web:http://www.chinattl.com Page 3 of 45 China Telecommunication Technology Labs. ® CONTENTS 1 GENERAL INFORMATION ................................................................ 4 1.1 NOTES ......................................................................................... 4 1.2 TESTERS ....................................................................................... 5 1.3 TESTING LABORATORY INFORMATION ...................................................... 6 1.4 DETAILS OF APPLICANT OR MANUFACTURER ............................................... 7 2 TEST ITEM ...................................................................................... 8 2.1 GENERAL INFORMATION ..................................................................... 8 2.2 OUTLINE OF EUT ............................................................................. 8 2.3 MODIFICATIONS INCORPORATED IN EUT .................................................. 8 2.4 EQUIPMENT CONFIGURATION ............................................................... 8 2.5 OTHER INFORMATION ........................................................................ 8 3 SUMMARY OF TEST RESULTS .......................................................... 9 4 TEST RESULTS .............................................................................. 10 4.1 RADIATED SPURIOUS EMISSION ........................................................... 10 4.2 RADIATED RF POWER OUTPUT AND ERP ................................................. 14 4.3 OCCUPIED BANDWIDTH ..................................................................... 17 4.4 FREQUENCY STABILITY OVER TEMPERATURE VARIATION ................................ 22 4.5 FREQUENCY STABILITY OVER VOLTAGE VARIATION ...................................... 24 4.6 CONDUCTED RF POWER OUTPUT .......................................................... 26 4.7 CONDUCTED SPURIOUS EMISSION ........................................................ 31 4.8 BAND EDGE .................................................................................. 37 ANNEX A EXTERNAL PHOTOS ........................................................... 41 ANNEX B INTERNAL PHOTOS ........................................................... 44 ANNEX C DEVIATIONS FROM PRESCRIBED TEST METHODS .............. 45 FCC Parts 2, 22, 24 Equipment: PremierWave XC REPORT NO.: I11GC0275-FCC-RF-2 Address:11 YUE TAN NAN JIE, BEIJING, P.R.C,100045 Tel:+86 10 68094053 FAX:+86 10 68011404 Web:http://www.chinattl.com Page 4 of 45 China Telecommunication Technology Labs. ® 1 General Information 1.1 Notes All reported tests were carried out on a sample equipment to demonstrate limited compliance with FCC CFR 47 Parts 2, 22 and 24. The test results of this test report relate exclusively to the item(s) tested as specified in section 2. The following deviation from, additions to, or exclusions from the test specifications have been made. See Annex C. China Telecommunication Technology Labs.(CTTL) authorizes the applicant or manufacturer (see section 1.4) to reproduce this report provided, and the test report may only be reproduced or published in full. Reproduction or publication of extracts from the report requires the prior written approval of CTTL Mr. He Guili. Any use which a third party makes of this report, or any reliance on or decisions to be made based on it, are the responsibility of such third parties. CTTL accepts no responsibility for damages, if any, suffered by any third party as a result of decisions made or actions based on this report. FCC Parts 2, 22, 24 Equipment: PremierWave XC REPORT NO.: I11GC0275-FCC-RF-2 Address:11 YUE TAN NAN JIE, BEIJING, P.R.C,100045 Tel:+86 10 68094053 FAX:+86 10 68011404 Web:http://www.chinattl.com Page 5 of 45 China Telecommunication Technology Labs. ® 1.2 Testers Name: Li Guoqing Position: Engineer Department: Department of EMC test Signature: Name: Lv Ke Position: Engineer Department: Department of EMC test Signature: Editor of this test report: Name: Li Guoqing Position: Engineer Department: Department of EMC test Date: 2012-3-6 Signature: Technical responsibility for area of testing: Name: Zou Dongyi Position: Manager Department: Department of EMC test Date: 2012-3-6 Signature: FCC Parts 2, 22, 24 Equipment: PremierWave XC REPORT NO.: I11GC0275-FCC-RF-2 Address:11 YUE TAN NAN JIE, BEIJING, P.R.C,100045 Tel:+86 10 68094053 FAX:+86 10 68011404 Web:http://www.chinattl.com Page 6 of 45 China Telecommunication Technology Labs. ® 1.3 Testing Laboratory information 1.3.1 Location Name: China Telecommunication Technology Labs. Address: N…
Text truncated - open the document above for the full version.
FCC SETUP PHOTOS
No. 11 Yue Tan Nan Street · Beijing · China
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 2 | 24E | 1.85 GHz - 1.91 GHz | 294.40 mW | 247KGXW | 0.1 ppm |
FOX5 Series
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterWi-Fi & Bluetooth Module
Equipment Class
NII - Unlicensed National Information Infrastructure TXOpen-Q 8550CS SOM
Equipment Class
DTS - Digital Transmission SystemWireless Module
Equipment Class
DTS - Digital Transmission System
E210 Series
Equipment Class
DTS - Digital Transmission System