Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Neutron Engineering Inc. Project No.: 1011C068 Page 2 of 6 1011C068 1011C068 Neutron Engineering Inc. Project No.: 1011C068 Page 2 of 6 1011C068 1011C068
: 1:1 PS-601TX 18-OCT-2010
Neutron Engineering Inc. Project No.: 1011C068 Page 3 of 6 1011C068 Neutron Engineering Inc. Project No.: 1011C068 Page 4 of 6 1011C068 1011C068 Neutron Engineering Inc. Project No.: 1011C068 Page 6 of 6 1011C068 1011C068 Neutron Engineering Inc. Project No.: 1011C068 Page 4 of 6 1011C068 1011C068 Neutron Engineering Inc. Project No.: 1011C068 Page 5 of 6 1011C068 1011C068 Neutron Engineering Inc. Project No.: 1011C068 Page 5 of 6 1011C068 1011C068 Neutron Engineering Inc. Project No.: 1011C068 Page 6 of 6 1011C068 1011C068
Neutron Engineering Inc. Report No.: NEI-FICP-1-1011C068 Page 2 of 33 Declaration Neutron represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with the standards traceable to National Measurement Laboratory (NML) of R.O.C., or National Institute of Standards and Technology (NIST) of U.S.A. Neutron's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. Neutron shall have no liability for any declarations, inferences o r generalizations drawn by the client or others from Neutron issued reports. Neutron’s reports must not be used by the client to claim product endorsement by the authorities or any agency of the Government. This report is the confidential property of the client. As a mutual protection to the clients, the public and Neutron-self, extracts from the test report shall not be reproduced except in full with Neutron’s authorized written approval. Neutron’s laboratory quality assurance procedures are in compliance with the ISO Guide 17025 requirements, and accredited by the conformity assessment authorities listed in this test report. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Neutron Engineering Inc. Report No.: NEI-FICP-1-1011C068 Page 3 of 33 Table of Contents Page 1 . CERTIFICATION 5 2 . SUMMARY OF TEST RESULTS 6 2.1 TEST FACILITY 7 2.2 MEASUREMENT UNCERTAINTY 7 3 . GENERAL INFORMATION 8 3.1 GENERAL DESCRIPTION OF EUT 8 3.2 DESCRIPTION OF TEST MODES 9 3.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 10 3.4 DESCRIPTION OF SUPPORT UNITS 10 4 . EMC EMISSION TEST 11 4.1 CONDUCTED EMISSION MEASUREMENT 11 4.1.1 POWER LINE CONDUCTED EMISSION LIMITS 11 4.1.2 MEASUREMENT INSTRUMENTS LIST 11 4.1.3 TEST PROCEDURE 12 4.1.4 DEVIATION FROM TEST STANDARD 12 4.1.5 TEST SETUP 12 4.1.6 EUT OPERATING CONDITIONS 12 4.1.7 TEST RESULTS 13 4.2 RADIATED EMISSION MEASUREMENT 14 4.2.1. FIELD STRENGTH OF FUNDAMENTAL EMISSIONS MEASUREMENT LIMIT 14 4.2.2. MEASURING INSTRUMENTS AND SETTING (FIELD STRENGTH OF FUNDAMENTAL EMISSIONS) 14 4.2.3 RADIATED EMISSIONS MEASUREMENT 15 4.2.4. DWELL TIME OF PERIODIC OPERATION MEASUREMENT 17 4.2.5. MEASUREMENT INSTRUMENTS LIST 18 4.2.6. TEST PROCEDURE 18 4.2.7. DEVIATION FROM TEST STANDARD 18 4.2.8. TEST SETUP 19 4.2.9. EUT OPERATING CONDITIONS 19 4.3. TEST RESULTS (9KHz-30MHz) 19 4.3.1 TEST RESULTS(BETWEEN 30 – 1000 MHz) 20 4.3.2 TEST RESULTS (ABOVE 1000 MHz) 24 5. 20dB SPECTRUM BANDWIDTH MEASUREMENT 28 5.1.MEASURING INSTRUMENTS AND SETTING 28 Neutron Engineering Inc. Report No.: NEI-FICP-1-1011C068 Page 4 of 33 Table of Contents Page 5.2.TEST PROCEDURES 28 5.3. TEST SETUP LAYOUT 28 5.4. TEST DEVIATION 28 5.5. EUT OPERATION DURING TEST 28 5.6. TEST RESULT 29 6. TIMING TESTING 30 6.1.MEASURING INSTRUMENTS AND SETTING 30 6.2.TEST PROCEDURES 30 6.3. TEST SETUP LAYOUT 30 6.4. TEST DEVIATION 30 6.5. EUT OPERATION DURING TEST 30 6.6. TEST RESULT 31 7. EUT TEST PHOTO 33 Neutron Engineering Inc. Report No.: NEI-FICP-1-1011C068 Page 5 of 33 1. CERTIFICATION Equipment : Wireless Thermometer Trade Name : ACURITE Model Name. : 00380TX A p p l i c a n t : Chaney Instrument Co. Date of Test : Nov. 04, 2010 ~ Nov. 11, 2010 T e s t I t e m : ENGINEERING SAMPLE Standards : FCC Part15, Subpart C(15.231)/ ANSI C63.4 : 2003; Canada RSS-210:2007 The above equipment has been tested and found compliance with the requirement of the relative standards by Neutron Engineering Inc. EMC Laboratory. The test data, data evaluation, and equipment configuration contained in our test report (Ref No. NEI-FICP-1-1011C068) were obtained utilizing the test procedures, test instruments, test sites that has been accredited by the Authority of NVLAP and TAF according to the ISO-17025 quality assessment standard and technical standard(s). Test result included in this report is only for the 00380TX-TX Sample part of the product. Neutron Engineering Inc. Report No.: NEI-FICP-1-1011C068 Page 6 of 33 2. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: FCC Part15, Subpart C (15.231) Standard Section Test Item Judgment Remark 15.207 Conducted Emission - Note(1)/(2) RSS210 2.7 Table Table 5 15.209 & 15.231(e) Radiated Spurious EmissionPASS RSS-210 A1.1.3 15.231(c) 20dB Occupied Bandwidth Measurement PASS Remark: (1)” N/A” denotes test is not applicable in this Test Report (2) The EUT is used new battery. Neutron Engineering Inc. Report No.: NEI-FICP-1-1011C068 Page 7 of 33 2.1 TEST FACILITY The test facilities used to collect the test data in this report is CB03 at the location of No.3,Jinshagang 1st Road, ShiXia, Dalang Town, Dong Guan, China.523792 Neutron's test firm number for FCC 319330 Neutron's test firm number for IC 4428B-1 2.2 MEASUREMENT UNCERTAINTY Where relevant, the following measurement uncertainty levels have been estimated for tests performed on the EUT as specified in CISPR 16-4-2: The reported uncertainty of measurement y ± U,where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of approximately 95 %。 A. Conducted Measurement : Test Site Method Measurement Frequency Range U,(dB) NOTE DG-C03 CISPR 150 KHz ~ 30MHz 1.94 B. Radiated Measurement : Test Site Method Measurement Frequency Range Ant. H / V U,(dB) NOTE CB03 CISPR 30MHz ~ 200MHz V 3.82 30MHz ~ 200MHz H 3.60 200MHz ~ 1,000MHz V 3.86 200MHz ~ 1,000MHz H 3.94 Neutron Engineering Inc. Report No.: NEI-FICP-1-1011C068 Page 8 of 33 3. GENERAL INFORMATION 3.1 GENERAL DESCRIPTION OF EUT Equipment Wireless Thermometer Trade Name ACURITE Model Name. 00380TX OEM Brand/Model Name N/A Model Differen…
Text truncated - open the document above for the full version.
Neutron Engineering Inc. Report No.: NEI-FICP-1-1011C068 Page 32 of 32 7. EUT TEST PHOTO Radiated Measurement Photos TX Mode Neutron Engineering Inc. Report No.: NEI-FICP-1-1011C068 Page 32 of 32 7. EUT TEST PHOTO Radiated Measurement Photos TX Mode
No.3,Jinshagang 1st Road, ShiXia, Dalang Town · Dongguan · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231(e) | 433.92 MHz - 433.92 MHz | - |

AcuRite IrisTM (5-in-1) Weather Sensor(Single Solar Panel), AcuRite IrisTM(5-in-1) Weather Sensor(Dual Solar Panel)
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
AcuRite Iri TM (5-in-1) Weather Sensor(Single Solar Panel), AcuRite Iri TM (5-in-1) Weather Sensor(Dual Solar Panel)
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Wireless Charging Forecaster
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Digital Freezer /Refrigerator Thermometer
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Professional Weather Center
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter