FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Winnix Technologies Co., Limited/
  3. RVZHYM740

RVZHYM740UHF RFID Reader Module

Winnix Technologies Co., Limited
UHF RFID Reader Module - FCC ID RVZHYM740 - Winnix Technologies Co., Limited
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Nov 06, 2013
Application Purpose
Original Equipment
Date of Application
Nov 06, 2013
Equipment Note
UHF RFID Reader Module
Frequency Range
902.75000000 - 927.25000000
Company
Winnix Technologies Co., Limited
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

UHF RFID Reader Module HYM740 Winnix Technologies Co.,Limited RFID Reader Module - 2 - Brief introduction HYM740 UHF RFID reader uses R2000 chip, which complies with EPC C1G2 protocol, its working frequency is 902~928MHz,with LBT function. It supports dense reader working mode(DRM)。With standard 7dBi antenna,the reading distance can reach 24 meters, maximum identifying speed can reach 400/S; with simple power supply and interface circuit, a high-performance RFID system can be established. It is suitable for logistics, apparel, medical industry, and complex assets management, etc. Technical data No Item Technical data Unit Remark 1 Max current 1.2 A Max power output 2 Standby current ≤1 mA EN pin low level 3 Frequency range 902~928 MHz 4 Default working frequency Frequency hopping MHz Frequency interval 250KHz 5 Channel bandwidth ≤250 KHz 6 Frequency hopping speed ≤2 s 7 Fixed power 30 dBm 8 Stepping interval 1~2 dB 5~30dBm, adjustable by software 9 Label protocol EPC C1G2 /ISO18000-6C 10 Communication protocol Asynchronous serial ports protocol 11 Starting time ≤50 ms 12 Radio-frequency power rising time ≤500 μs 13 Radio-frequency power dropping time ≤500 μs ≤-40 dB ±1CH 14 Adjacent channel power leaking ratio ≤-60 dB ±2CH ±10 ppm -25°C~+40°C 15 Frequency stabilizing ratio ±20 ppm -40°C~+60°C 16 Max reading range 24 m 7dBi antenna 17 Multi-tags >400/s RFID Reader Module - 3 - Characteristics of DC Data Mini value Ty pi ca l value Max valueUnit Remark Voltage of power 4.5 5 5.5 V Direct current 2 3.3 5.5 V GPIO Input high level 2 - 5 V EN -0.3 0 0.8 V GPIO Input low level - - 0.18 V EN Output high level 2.9 - - V GPIO Output low level - 0 0.1 V GPIO Enable current 2 5 25 uA V EN ≥2V Requirement on antenna No Item Technical data Unit Remark 1 Standing wave ratio ≤1.5 Appearance and structure z Size: 76.5×39.7×9mm z Weight: 50g RFID Reader Module - 4 - Drawing 1 Front view of the reader RFID Reader Module - 5 - Drawing2 Side view of the reader Drawing3 Pin connector RFID Reader Module - 6 - Interface definition Pin Signal name Signal direction Function/compatibility description 1 VCC Input Module supplying power 2 VCC Input Module supplying power 3 GND - Module connecting ground 4 GND - Module connecting ground 5 EN Input Module enabling,highly effective 6 GPIO Bidirection Generic port 7 GPIO Bidirection Generic port 8 GPIO Bidirection Generic port 9 UART_RX Input Asynchronous serial interface receiving 10 UART_TX Output Asynchronous serial interface sending 11 DBG_RX - Test port 12 DBG_TX - Test port OEMs information: RealID Technology Co., Ltd. was established in December 2012, the registered capital of 990 million yuan. It is a professional company specializing in RFID system design, equipment development and related technical services. RealID Technology Co., Ltd. gathered a number of highly qualified management personnel, first-class product development elite, to provide customers with first-class hardware products, program design, and custom services. Changes or modifications made to the equipment not expressly approved by Winnix may void the FCC / IC authorization to operate this equipment. The use of the transceiver module is authorized in mobile or fixed host devices taking into account the conditions listed below :• OEM Integrator must ensure that the end user manual may not contain any information about the way to install or remove the module from the final product. • Depending on the final host device additional authorization requirements for the nontransmitter functions of the transmitter module may be required (i.e., Verification, or Declaration of Conformity) The OEM integrator is responsible for ensuring that a er the module is installed and operational the host continues to be compliant with the Part 15B unintentional radiator requirements. • The information on the label and in the user manual is required to be incorporated in the user manual of the final host. see 47 CFR15 requirements for more details (e.g. 15.19 / 15.21 / 15.101 / 15.105 / RSSGEN / ICES) • Additional label with the words ‘Contains FCC ID: RVZHYM740’ shall be applied and visible from the outside of the host product. RFID Reader Module - 7 - • The module must be installed and used in strict accordance with the manufacturer’s instructions as described in the user documenta on that comes with the module .• The end user manual for the final host product operating with this transmitter must include operatng instructions to satisfy RF exposure compliance requirements. e.g Radiofrequency radiation exposure Information: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance of 25 cm between the radiator and your body.This transmitter must not be colocated or operating in conjunction with any other antenna or transmitter .• When the final host product operating with this transmitter deviate from above, installation of this module into specific final hosts may require the submission of a Class II permissive change application containing data pertinent to RF Exposure, spurious emissions, ERP/EIRP, and host/module authen ca on, or new application if appropriate Feel free to contact us if additional guidance is required. Manual Requirements according 15.19 / RSSGEN This device complies with Part 15 of the FCC Rules [and with Industry Canada licence exempt RSS standard(s)]. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired opera on. Manual Requirements according 15.21 Changes or modifi ca ons made to this equipment not expressly approved by (manufacturer name) may void the FCC authorization to operate this equipment. Environment requirement No Item Technical data Unit Remark 1 Wo r k i n g temperature -25~+75 °C 2 Storage temperature -40~+85 °C …

Text truncated - open the document above for the full version.

Cover Letter(s)

AGENCY AUTHORIZATION LETTER FCC ID: RVZHYM740 Date: Feb.20,2013 To whom it may concern: We, the undersigned, hereby authorize Shenzhen Huatongwei International Co.,Ltd of China to act on our behalf, as our agent in the following matters related to the FCC approval of our products: report submittal, related correspondence, the signing of all documents relating to these matters, and any other lawful activity necessary to obtain such certification, Any act carried out by Shenzhen Huatongwei International Co.,Ltd. within the scope of this authorization shall have the same effects as our own. This authorization shall expire 12 months from original date. If you have any questions regarding the authorization, please don’t hesitate to contact us. Sincerely, (签名人英文名): Victoria Lee (签名人职称): GM Winnix Technologies Co., Limited Tel: 0755-86028268-8652 Fax: 0755-26012377 E-mail: [email protected]

Cover Letter(s)

Declaration letter FCC ID: RVZHYM740 Date: Oct.30,2013 1) Marketing The device must be sold to dealers. 2) Professional installation Installed by licensed professionals ( EUT sold to dealer who hire installers) 3) Application The intended use is generally not for the general public. It is generally for industry/commercial use. Sincerely, Victoria Lee GM Winnix Technologies Co., Limited Tel: 0755-86028268-8652 Fax: 0755-26012377 E-mail: [email protected]

Cover Letter(s)

Letter for Confidentiality Federal Communications Commission Authorization and Evaluation Division Date: Feb.20,2013 Confidentiality Request regarding application for certification of FCC ID: RVZHYM740 Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: 1.Schematic 2.Theory of Operation 3.Block Diagram The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, We do not want these documents to be accessible to the general public. Sincerely, (签名人英文名): Victoria Lee (签名人职称): GM Winnix Technologies Co., Limited Tel: 0755-86028268-8652 Fax: 0755-26012377 E-mail: [email protected]

Cover Letter(s)

May 28,2013 Request for Limited Single Modular Approval Attestation for the Module (FCC ID: RVZHYM740) (i) The radio elements of the modular transmitter must have their own shielding. The physical crystal and tuning capacitors may be located ex‐ternal to the shielded radio elements. Yes, The modular transmitter has its own shielding as shown on the external photo exhibits. (ii) The modular transmitter must have buffered modulation/data inputs (if such inputs are provided) to ensure that the module will comply with part 15 requirements under conditions of ex‐cessive data rates or over‐modulation. Yes, All input/output data are buffered and processed by the onboard miccontroller. (iii) The modular transmitter must have its own power supply regulation. Yes,The modular with DC 5.0 regulation power supply; (iv) The modular transmitter must comply with the antenna and transmission system requirements of §§15.203, 15.204(b) and 15.204(c). The antenna must either be permanently attached or employ a ‘‘unique’’ antenna coupler (at all connections between the module and the antenna, including the cable). The ‘‘professional installation’’ provision of §15.203 is not applicable to modules but can apply to limited modular approvals under paragraph (b) of this section. No,The modular transmitter hasn’t antenna. We used an external antenna provided by Winnix, Technologies Co., Limited. There are related information about test antenna in the report. (v) The modular transmitter must be tested in a stand‐alone configuration, i.e., the module must not be inside an‐other device during testing for compliance with part 15 requirements. Unless the transmitter module will be battery powered, it must comply with the AC line conducted requirements found in §15.207. AC or DC power lines and data input/output lines connected to the module must not contain ferrites, un‐less they will be marketed with the module (see §15.27(a)). The length of these lines shall be the length typical of actual use or, if that length is unknown, at least 10 centimeters to insure that there is no coupling between the case of the module and supporting equipment. Any accessories, peripherals, or support equipment connected to the module during testing shall be unmodified and commercially available. Yes, The modular transmitter has been performed the testing as a stand alone and then confirmed the compliance. (vi) The modular transmitter must be equipped with either a permanently affixed label or must be capable of electronically displaying its FCC identification number. (A) If using a permanently affixed label, the modular transmitter must be labeled with its own FCC identification number, and, if the FCC identification number is not visible when the module is installed inside another device, then the outside of the device into which the module is installed must also display a label referring to the enclosed module. This exterior label can use wording such as the following: ‘‘Contains Trans‐mitter Module FCC ID: XYZMODEL1’’ or ‘‘Contains FCC ID: XYZMODEL1.’’ Any similar wording that expresses the same meaning may be used. The Grant‐ee may either provide such a label, an example of which must be included in the application for equipment author‐ization, or, must provide adequate in‐structions along with the module which explain this requirement. In the latter case, a copy of these instructions must be included in the application for equipment authorization. (B) If the modular transmitter uses an electronic display of the FCC identi‐fication number, the information must be readily accessible and visible on the modular transmitter or on the device in which it is installed. If the module is installed inside another device, then the outside of the device into which the module is installed must displaya label referring to the enclosed module. This exterior label can use wording such as the following: ‘‘Contains FCC certified transmitter module(s).’’ Any similar wording that expresses the same meaning may be used. The user manual must include instructions on how to access the electronic display. A copy of these instructions must be in‐cluded in the application for equipment authorization. Yes,the modular with own FCC ID: RVZHYM740 will be labeled onto the modular transmitter. (vii) The modular transmitter must comply with any specific rules or operating requirements that ordinarily apply to a complete transmitter and the manufacturer must provide adequate instructions along with the module to explain any such requirements. A copy of these instructions must be included in the application for equipment authorization. Yes, The modular transmitter is compliant with part 15.247. Installation and other requirements are presented in the manual . (viii) The modular transmitter is compliant with part 15.247. Installation and other requirements are presented in the manual . Yes, The modular transmitter is compliant with part 15.247. Installation and other requirements are presented in the manual . Sincerely, Victoria Lee Title: GM Winnix Technologies Co., Limited Tel: 0755‐86028268‐8652 Fax: 0755‐26012377 E‐mail: [email protected]

External Photos

External photos of the EUT

ID Label/Location Info

FCC ID:RVZHY740

Internal Photos

Internal photos of the EUT

RF Exposure Info

MPE TEST REPORT FCC Per 47 CFR 2.1091(b) Report Reference No. .................... : FCC ID . ........................................... : TRE1305013302 R/C: 22760 RVZHYM740 Compiled by ( position+printed name+signature) .. : File administrators Jerome Luo Supervised by ( position+printed name+signature) .. : Test Engineer Yuchao Wang Approved by ( position+printed name+signature) .. : Manager Wenliang Li Date of issue ..................................... : May 31, 2013 Testing Laboratory Name .............. : Shenzhen Huatongwei International Inspection Co., Ltd Address ............................................. : Keji Nan No.12 Road, Hi-tech Park, Shenzhen, China Applicant’s name ............................ : Winnix Technologies Co., Limited Address ............................................. : 4/F R2-B Building,Hi-tech Park,NanShan District,ShenZhen, GuangDong,China Test specification: Standard ........................................... : FCC Per 47 CFR 2.1091(b) TRF Originator .................................. : Shenzhen Huatongwei International Inspection CO., Ltd Master TRF ....................................... : Dated 2006-06 Shenzhen Huatongwei International Inspection Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen Huatongwei International Inspection Co., Ltd is acknowledged as copyright owner and source of the material. Shenzhen Huatongwei International Inspection Co., Ltd takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description .................... : UHF RFID Reader Module Trade Mark ....................................... : / Model/Type reference ....................... : HYM740, UM620, UM7 Modulation ........................................ : GFSK Listed Models .................................. : / Result ................................................ : Positive Report No.: TRE1305013302 Page 2 of 7 Issued:2013-05-31 T E S T R E P O R T Test Report No. : TRE1305013302 May 31, 2013 ______________________________________________________________________________________________ Date of issue Equipment under Test : UHF RFID Reader Module Model /Type : HYM740, UM620, UM7 Listed Models : / Applicant : Winnix Technologies Co., Limited. Address : 4/F R2-B Building,Hi-tech Park,NanShan District,ShenZhen, GuangDong,China Manufacturer : REALID TECHNOLOGY CO., LTD. Address : Unit04,7/F,Bright way tower,NO.33 Mong KOK Road,Kowlood,HK. The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: TRE1305013302 Page 3 of 7 Issued:2013-05-31 Contents 1. SUMMARY ............................................................................. 4 1.1. EUT configuration 4 1.2. Power supply system utilised 4 1.3. Description of the test mode 4 1.4. Related Submittal(s) / Grant (s) 4 1.5. Modifications 4 1.6. NOTE 4 2. TEST ENVIRONMENT ............................................................... 5 2.1. Address of the test laboratory 5 2.2. Environmental conditions 5 2.3. Statement of the measurement uncertainty 5 3. METHOD OF MEASUREMENT .................................................... 6 3.1. Applicable Standard 6 3.2. Limit 6 3.3. MPE Calculation Method 6 4. CONCLUSION ........................................................................ 7 Report No.: TRE1305013302 Page 4 of 7 Issued:2013-05-31 1. SUMMARY 1.1. EUT configuration The following peripheral devices and interface cables were connected during the measurement: ● - supplied by the manufacturer ○ - supplied by the lab ○ Power Cable Length (m) : / Shield : / Detachable : / ○ Multimeter Manufacturer : / Model No. : / 1.2. Power supply system utilised Power supply voltage : ○ 120V / 60 Hz ○ 115V / 60Hz ○ 12 V DC ○ 24 V DC ● Other (specified in blank below) DC 5.0V 1.3. Description of the test mode The EUT has been tested under typical operating condition.The Applicant provides communication tools software to control the EUT for staying in continous transmitting and receiving mode for testing. There are 50 channels of EUT, and the test carried out at the lowest channel, middle channel and highest channel . Frequency Range: 902-928MHz Channel number: 50 channels Modulation type: GFSK Antenna: External Antenna 1.4. Related Submittal(s) / Grant (s) This submittal(s) (test report) is intended for FCC ID: RVZHYM740 filing to comply with Section 15.247 of the FCC Part 15, Subpart C Rules. 1.5. Modifications No modifications were implemented to meet testing criteria. 1.6. NOTE 1. The EUT is a UHF RFID Reader Module.The functions of the EUT are listed as below: Test Standards Reference Report Radio FCC Part 15 Subpart C (Section15.247) TRE1305013301 RF Exposure MPE report TRE1305013302 Report No.: TRE1305013302 Page 5 of 7 Issued:2013-05-31 2. TEST ENVIRONMENT 2.1. Address of the test laboratory Shenzhen Huatongwei International Inspection Co., Ltd Keji Nan No.12 Road, Hi-tech Park, Shenzhen, China Phone: 86-755-26715686 Fax: 86-755-26748089 The sites are constructed in conformance with the requirements of ANSI C63.7, ANSI C63.4 (2009) and CISPR Publication 22. 2.2. Environmental conditions During the measurement the environmental conditions were within the listed ranges: Temperature: 15-35 ° C Humidity: 30-60 % Atmospheric pressure: 950-1050mbar 2.3. Statement of the measurement uncertainty The data and results referenced in this document are true and accurate. The reader is cautioned that there may be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was calculated for all measurements listed in this test report acc. to TR-100028-01” Electromagnetic compatibility and Radio spectrum Matters (ERM);Uncertainties in the measurement of mobile rad…

Text truncated - open the document above for the full version.

Test Report

FCC PART 15 SUBPART C TEST REPORT FCC PART 15.247 Report Reference No. .....................: FCC ID . ............................................: TRE1305013301 R/C:22760 RVZHYM740 Compiled by ( position+printed name+signature) .. : File administrators Jerome Luo Supervised by ( position+printed name+signature) .. : Test Engineer Yuchao Wang Approved by ( position+printed name+signature) .. : Manager Wenliang Li Date of issue ..................................... : May 31, 2013 Testing Laboratory Name .............. : Shenzhen Huatongwei International Inspection Co., Ltd Address ............................................ : Keji Nan No.12 Road, Hi-tech Park, Shenzhen, China Applicant’s name ............................ : Winnix Technologies Co., Limited Address ............................................ : 4/F R2-B Building,Hi-tech Park,NanShan District,ShenZhen, GuangDong,China Test specification: Standard ........................................... : FCC Part 15.247: Operation within the bands 902-928 MHz, 2400-2483.5 MHz and 5725-5850 MHz Direct Sequence System TRF Originator .................................. : Shenzhen Huatongwei International Inspection CO., Ltd Master TRF ....................................... : Dated 2006-06 Shenzhen Huatongwei International Inspection Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen Huatongwei International Inspection Co., Ltd is acknowledged as copyright owner and source of the material. Shenzhen Huatongwei International Inspection Co., Ltd takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description ..................... : UHF RFID Reader Module Trade Mark ....................................... : / Model/Type reference ....................... : HYM740,UM620,UM7 Modulation ........................................ : GFSK Manufacturer ................................... : REALID TECHNOLOGY CO., LTD. Listed Models .................................. : / Ratings ............................................ : DC 5.0 V Result................................................ : Positive Report No.: TRE1305013301 Page 2 of 47 Issue Data:2013-05-31 T E S T R E P O R T Test Report No. : TRE1305013301 May 31, 2013 ______________________________________________________________________________________________ Date of issue Equipment under Test : UHF RFID Reader Module Model /Type : HYM740,UM620,UM7 Listed Models : / Applicant : Winnix Technologies Co., Limited. Address : 4/F R2-B Building,Hi-tech Park,NanShan District,ShenZhen, GuangDong,China Manufacturer : REALID TECHNOLOGY CO., LTD. Address : Unit04,7/F,Bright way tower,NO.33 Mong KOK Road,Kowlood,HK. Test Result according to the standards on page 4: Positive The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: TRE1305013301 Page 3 of 47 Issue Data:2013-05-31 Contents 1. TEST STANDARDS .................................................................. 4 2. SUMMARY ............................................................................. 5 2.1. General Remarks 5 2.2. Equipment Under Test 5 2.3. Short description of the Equipment under Test (EUT) 5 2.4. EUT operation mode 5 2.5. Related Submittal(s) / Grant (s) 6 2.6. Configuration of Test System 6 2.7. EUT configuration 6 2.8. Modifications 6 2.9. NOTE 7 3. TEST ENVIRONMENT ............................................................... 8 3.1. Address of the test laboratory 8 3.2. Test Facility 8 3.3. Environmental conditions 9 3.4. Test Description 9 3.5. Statement of the measurement uncertainty 9 3.6. Equipments Used during the Test 10 4. TEST CONDITIONS AND RESULTS ............................................ 11 4.1. AC Power Conducted Emission(Not Applicable) 11 4.2. Radiated Emission 12 4.3. Spurious RF CONDUCTED EMISSIONS 18 4.4. Maximum Peak Output Power 21 4.5. 20dB Bandwidth 24 4.6. Band Edge 27 4.7. Frequency Separation 29 4.8. Number of hopping frequency 32 4.9. Time Of Occupancy(Dwell Time) 33 4.10. Receiver spurious Emissions 36 4.11. Antenna Requirement 42 5. TEST SETUP PHOTOS OF THE EUT .......................................... 43 6. EXTERNAL AND INTERNAL PHOTOS OF THE EUT ....................... 45 Report No.: TRE1305013301 Page 4 of 47 Issue Data:2013-05-31 1. TEST STANDARDS The tests were performed according to following standards: FCC Rules Part 15.247: Frequency Hopping, Direct Spread Spectrum and Hybrid Systems that are in operation within the bands of 902-928 MHz, 2400-2483.5 MHz, and 5725-5850 MHz. ANSI C63.10-2009 : American National Standard for Testing Unlicensed Wireless Devices Report No.: TRE1305013301 Page 5 of 47 Issue Data:2013-05-31 2. SUMMARY 2.1. General Remarks Date of receipt of test sample : May 23,2013 Testing commenced on : May 23,2013 Testing concluded on : May 31, 2013 2.2. Equipment Under Test Power supply system utilised Power supply voltage : ○ 120V / 60 Hz ○ 115V / 60Hz ○ 12 V DC ○ 24 V DC ● Other (specified in blank below) DC 5.0V 2.3. Short description of the Equipment under Test (EUT) 902-928MHz (UHF RFID Reader Module (HYM740,UM620,UM7)), For more details, refer to the user’s manual of the EUT. Serial number: Prototype 2.4. EUT operation mode The EUT has been tested under typical operating condition.The Applicant provides communication tools software to control the EUT for staying in continous transmitting and receiving mode for testing. There are 50 channels of EUT, and the test carried out at the lowest channel, middle channel and highest channel . Frequency Range: 902-928MHz Channel number: 50 channels Modulation type: GFSK Antenna: External Antenna Description of the test mode There are fifty channels provide to the EUT. Channel Frequency(MHz) Channe…

Text truncated - open the document above for the full version.

Test Setup Photos

Test photos

Contact Information

Applicant

Victorica Lee(GM)
[email protected]0086 755 8602 8268Fax: 0086 755 2601 2377

Test Firm

Shenzhen Huatongwei International Insp. Co., LtdMoffy Yu
[email protected]86-755-26748078Fax: 86-755-26748089

Technical Specifications

#Rule PartsFrequency RangePower Output
115C902.75 MHz - 927.25 MHz785.00 mW
Modular Type
Limited Single Modular Approval
Confidentiality
Long Term
Grant Notes
Power output listed is peak conducted. Limited single modular approval due to professional installation requirements as described in this filing. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 25 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC accepted multi-transmitter procedures. OEM integrators must be provided with antenna installation instructions. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Winnix Technologies Co., Limited

Integrated UHF RFID Reader - FCC ID RVZ-HYR860 - Winnix Technologies Co., Limited
RVZ-HYR860

Integrated UHF RFID Reader

Jan 16, 2023

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
UHF RFID Reader Module - FCC ID RVZHYM360 - Winnix Technologies Co., Limited
RVZHYM360

UHF RFID Reader Module

Jun 29, 2015

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
UHF Reader - FCC ID RVZHYR830 - Winnix Technologies Co., Limited
RVZHYR830

UHF Reader

Jan 13, 2014

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
UHF Desktop Reader - FCC ID RVZHYR810 - Winnix Technologies Co., Limited
RVZHYR810

UHF Desktop Reader

Jan 04, 2014

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
UHF RFID Reader Module - FCC ID RVZHYM730 - Winnix Technologies Co., Limited
RVZHYM730

UHF RFID Reader Module

Dec 03, 2013

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter