FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Razer Inc./
  3. RWO-562C

RWO-562CCharging case or XBOX Charging Case

Razer Inc.

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Apr 10, 2026
Application Purpose
Original Equipment
Equipment Note
Charging case or XBOX Charging Case
Frequency Range
2402.00000000 - 2480.00000000
Company
Razer Inc.
Country
United States

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗
↗
↗
↗
↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

FCC COVERED LIST DECLARATION LETTER Page 1 of 1 Revision 1.0 SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia 30024 United States Applicant Legal Business Name Razer Inc. Address 9 Pasteur, Suite 100, Irvine, California 92618, United States FRN 0022386734 Grantee Code RWO FCC ID: RWO-562 and RWO-562C Authorized Contact Name Johnsen Tia Contact Phone 760 579 0180 Contact Email [email protected] Razer Inc. (“the applicant”) certifies: - the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. - as of the date of the filing of the application, the applicant [is not] identified on the Covered list, established pursuant to §1.50002, as an entity producing “covered” equipment. - the software to be loaded prior to marketing of the equipment identified above is not “covered” software manufactured by any entity including predecessors, successors, parents, subsidiaries, affiliates or any entity which has rebranded or relabeled the software produced by the entity(ies) identified on the “Covered List”. - the device is not capable of storing or running software listed on the covered list and therefore is inherently compliant. NOTE: Justification/evidence explaining how compliance is met must accompany this letter Link to the Covered List: Covered List Applicant Signature: Date: 12/05/2025 Print Name: Johnsen Tia Title: Associate VP, Regulatory & Compliance *NOTE: This declaration cannot be signed by an Agent, it shall be signed by an authorized person listed in the FCC database

Attestation Statements

Applicant Declaration QSF27-14-04 Rev 1.4 April 25, 2025 Page 1 of 1 Original Issue: Jan. 4, 2021 SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia 30024 United States Applicant Legal Business Name Razer Inc. Address 9 Pasteur, Irvine, California 92618, United States FRN 0022386734 Grantee Code RWO FCC ID: RWO-562 and RWO-562C Authorized Contact Name Johnsen Tia Contact Phone 760 579 0180 Contact Email [email protected] I, the undersigned, certify that I am an authorized signatory for the Applicant and therefore declare; a) in accordance with 47CFR2.911(d), all of the statements herein and the exhibits attached hereto are true and correct to the best of my knowledge and belief. b) in accepting a Grant of Equipment Authorization issued by a TCB, under the authority of the FCC, as a result of the representations made in this application, the Applicant is responsible for: (1) labeling the equipment with the exact FCC ID as specified in this application, (2) compliance statement labeling pursuant to the applicable rules, (3) compliance of the equipment with the applicable technical rules, c) if the Applicant is not the actual manufacturer of the equipment, appropriate arrangements have been made with the manufacturer to ensure that production units of this equipment will continue to comply with the FCC’s technical requirements. d) in accordance with 47 CFR 2.909 and KDB394321, the Applicant has read, understood and agrees to accept that they are the responsible party and agree to abide by their responsibilities as specified under 47 CFR 2.909 and KDB394321. e) in accordance with ISO 17065, FCC KDB641163, FCC KDB610077, KDB394321 and RSP-100, the Applicant has read, understood, accepts and agrees to abide by the post market surveillance requirements. (1) the Applicant understands, accepts and agrees that a sample may be requested for surveillance testing. (2) the Applicant shall make provisions to always have a production sample available upon request by SGS, FCC and/or ISED. (3) the Applicant shall, upon request by SGS, at the Applicant’s expense, provide a production sample of the requested product to SGS, FCC and/or ISED as instructed. The sample shall include all support devices, cables, software, accessories or other hardware or software required for evaluation, review, certification and audit surveillance of products certified by SGS. f) neither the Applicant nor any party to the application is subject to a denial of Federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. §862 because of a conviction for possession or distribution of a controlled substance. See 47CFR 1.2002(b) for the definition of a “party” for these purposes. g) the Applicant has read, understood, accepts and agrees to abide by the SGS North America, Inc. terms and conditions as specified in the TCB Application Form 731 (QSF27-14-01). Link to CFRs: https://www.fcc.gov/wireless/bureau-divisions/technologies-systems-and-innovation-division/rules-regulations-title-47 Link to KDBs: https://apps.fcc.gov/oetcf/kdb/index.cfm Link to RSP-100: https://www.ic.gc.ca/eic/site/smt-gst.nsf/eng/sf01130.html Link to the Covered List: Covered List Applicant Signature: Date: 12/05/2025 Print Name: Johnsen Tia Title: Associate VP, Regulatory & Compliance *NOTE: This declaration cannot be signed by an Agent, it shall be signed by an authorized person listed in the FCC database

Attestation Statements

UNITED STATES DESIGNATED AGENT LETTER Date: 12/05/2025 TO: Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 Applicant U.S. designated agent Company Name: Razer Inc. Company Name: Razer Inc. FRN: 0022386734 FRN: 0022386734 Grantee Code: RWO Contact Name: Johnsen Tia Contact Name: Johnsen Tia Address: 9 Pasteur, Address: 9 Pasteur, City/Province/Zip: Irvine California 92618 United States City/Province/Zip: Irvine California 92618 United States Telephone: 760 579 0180 Telephone: 760 579 0180 Fax: 760 579 0182 Fax: 760 579 0182 Email: [email protected] Email: [email protected] Applicable Equipment: FCC ID: RWO-562 and RWO-562C ATTN: Director of Certification: We, < Razer Inc.> understand and acknowledge the applicants consent and the designated agent’s obligation to accept service of process in the United States for matters related to the applicable equipment, and at the physical U.S. address and e-mail of the designated agent listed above. We, < Razer Inc.> acknowledge the applicant’s acceptance of its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. Name (Printed): Johnsen Tia Title: Associate VP, Regulatory & Compliance Signature:

Cover Letter(s)

Razer Inc. Date: 12/05/2025 TO: Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 Regarding: FCC ID: RWO-562 and RWO-562C To whom it may concern: We, the undersigned, hereby authorize SGS-CSTC Standards Technical Services Co., Ltd to act on our behalf in all manners relating to application for equipment authorization with respect to the FCC ID above, including signing of all documents relating to these matters. Any and all acts carried out by the agent on our behalf shall have the same effect as acts of our own. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). Where our agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by SGS North America, Inc., still resides with Razer Inc. This authorization is valid until further written notice from the applicant. Sincerely, Print Name: Johnsen Tia Title: Associate VP, Regulatory & Compliance Signature: On behalf of Company: Razer Inc. Telephone: 760 579 0180 E-mail: [email protected]

Cover Letter(s)

Razer Inc. TO: Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 Regarding: Confidentiality Request for FCC ID: RWO-562 and RWO-562C LONG TERM CONFIDENTIALITY Pursuant to 47 CFR Section 0.459 and 0.457 of the commission’s rules, the applicant hereby request confidential treatment of the documents listed below, associated with the certification application referenced above. Schematic(s) Block Diagrams Operational Descriptions Tune Up Procedures The documents above contain proprietary information not released to the public. Public disclosure of this information may prove harmful to the business of the applicant. SHORT TERM CONFIDENTIALITY Additionally, the applicant requests the following documents be held confidential until the device is marketed or 180 days from the grant date, whichever is less. If the device is marketed within aforementioned days of the Grant Date, the applicant will notify the TCB per FCC KDB 726920 D01 Confidentiality Request Procedures. External Photos Internal Photos Test Setup Photos User manual(s) Sincerely, Print Name: Johnsen Tia Title: Associate VP, Regulatory & Compliance Signature: On behalf of Company: Razer Inc. Telephone: 760 579 0180 E-mail: [email protected] Razer Inc.

ID Label/Location Info

Model No.: 562C Charging Case Rated Capacity: 5V/400mAh/2Wh 1ICP7/22/31 FCC ID: RWO-562C P/No.: RZ12-05620100 S/N: CMYYWWAAAAXXXXX RAZER INC. MADE IN CHINA Input: 5V 600mA (Max) Output (L/R): 5V 160mA (Max) Total output (L+R): 5V 320mA (Max) Wireless Earphones Input: 5V 320mA MIC US SKU CHARGING CASEINNER CHARGING CASESKU PID engrave Rev260109 by DL@Razer CM= Contract Manufacturer (Minami Electronics Malaysia Sdn Bhd) = Serial Number Format: CMYYWWAAAAXXXXX M2 CM= Contract Manufacturer (Minami Acoustics Limited) = M1 YY = year, 2026 =26 WW= work week when the product is final assembled and final tested AAAA = Product Serial code (assigned by Razer) = as chart XXXXX = running serial numbers , start from 00001 Pantone Coolgreay 10C *follow old Amelia US > D435 EU > D436 Model No.: 562C Charging Case Rated Capacity: 5V/400mAh/2Wh 1ICP7/22/31 Li-ion Cell Capacity: 3.85V, 2.31WhCell Capacity: 3.85V, 2.31Wh FCC ID: RWO-562C Input: 5V 600mA (Max) Output (L/R): 5V 160mA (Max) Total output (L+R): 5V 320mA (Max) Wireless Earphones Input: 5V 320mA

RF Exposure Info

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01 Rev. A/2 Report No.: SZCR251100528203 Page: 1 of 34 Keny Xu EMC Laboratory Manager SAR TEST REPORT Application No.: SZCR2511005282AT Applicant: Razer Inc. Address of Applicant: 9 Pasteur, Irvine, California 92618 United States Manufacturer: Razer (Asia-Pacific) Pte. Ltd. Address of Manufacturer: Razer SEA HQ, 1 one-north Crescent, #02-01, 138538, Singapore EUT Description: Charging case or XBOX Charging Case Model No.: 562C Trade Mark: RAZER FCC ID: RWO-562C Standards: FCC 47CFR §2.1093 Date of Receipt: 2025-12-02 Date of Test: 2025-12-19 Date of Issue: 2025-12-26 Test Result : PASS * * In the configuration tested, the EUT detailed in this report complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01 Rev. A/2 Report No.: SZCR251100528203 Page: 2 of 34 Revision Record Version Description Date Remark 01 2025-12-26 Original Authorized for issue by: Charlie Dai/Project Engineer Eric Fu / Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01 Rev. A/2 Report No.: SZCR251100528203 Page: 3 of 34 TEST SUMMARY Frequency Band Maximum Reported 1gSAR(W/kg) Body-worn 2.4G SRD 0.64 SAR Limited(W/kg) 1.6 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01 Rev. A/2 Report No.: SZCR251100528203 Page: 4 of 34 Contents 1 General Information .......................................................................................................... 6 1.1 General Description of EUT ........................................................................................ 6 1.2 Test Specification ......................................................................................................... 7 1.3 RF exposure limits........................................................................................................ 8 1.4 Test Location ................................................................................................................. 9 1.5 Test Engineer ................................................................................................................ 9 1.6 Test Facility ................................................................................................................... 9 2 Laboratory Environment ............................................................................................... 10 3 SAR Measurements System Configuraion ............................................................... 11 3.1 The SAR Measurement System .............................................................................. 11 3.2 Isotropic E-field Proble EX3DV4 .............................................................................. 13 3.3 Data Acquisition Electronics (DAE) ......................................................................... 14 3.4 SAM Twin Phantom ................................................................................................... 14 3.5 ELI Phantom................................................................................................................ 15 3.6 Device Holder for Transmitters ................................................................................ 16 3.7 Measurement Procedure ........................................................................................... 17 3.7.1 Scanning procedure ............................................................................................ 17 3.7.2 Data storage ......................................................................................................... 19 3.7.3 Data Evaluation by SEMCAD ............................................................................ 19 4 SAR measurement variability and uncertainty ....................................................... 21 4.1 SAR measurement variability ................................................................................... 21 4.2 SAR measurement uncertainty ................................................................................ 21 5 Desciption of Test Position .......................................................................................... 22 5.1 The EUT Test Position .............................................................................................. 22 6 SAR System Verificaion Procedure ........................................................................... 23 6.1 Tissue Simulate Liquid .............................................................................................. 23 6.1.1 Recipes for Tissue Simulate Liquid .................................................................. 23 6.1.2 Measurement for Tissue Simulate Liquid ........................................................ 24 6.2 SAR System Check.................................................................................................... 25 6.2.1 Justification for Extended SAR Dipole Calibrations ....................................... 26 6.2.2 Summary System Check Result(s)................................................................... 27 6.2.3 Detailed System Check Results ........................................................................ 27 7 Test Configuration .......................................................................................................... 28 7.1 Operation Configurations .......................................................................................... 28 7.1.1 2.4GHz SRD Test Configuration ....................................................................... 28 8 Test Result ........................................................................................................................ 29 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01 Rev. A/2 Report No.: SZCR251100528203 Page: 5 of 34 8.1 DUT Antenna Locations (Back View) ...................................................................... 29 8…

Text truncated - open the document above for the full version.

RF Exposure Info

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01-A01 Rev. A/1 Aug 16,2024 Report No.: SZCR251100528203 Page: 1 of 33 Appendix C Calibration certificate 1. Dipole D2450V2-SN 733 2. DAE DAE4-SN 760 3. Probe EX3DV4-SN 7821

RF Exposure Info

-End of the Appendix-

RF Exposure Info

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01-A04 Rev. A/0 Aug 16,2024 Report No.: SZCR251100528203 Page: 1 of 2 Appendix B Detailed Test Results 1. SRD 2.4G SRD Date: 2025/12/19 Test Laboratory: SGS-SAR Lab 2.4G SRD 1M 2480MHz Front side 0mm DUT: Amelia T3 V3; Type: Wireless charging case; Serial: M12547D43700654 Communication System: UID 0, SDR 2.4G (0); Frequency: 2480 MHz;Duty Cycle: 1:1.156 Medium: HSL;Medium parameters used: f = 2480 MHz; σ = 1.827 S/m; ε r = 38.491; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY 5 Configuration: Probe: EX3DV4 - SN7821; ConvF(7.4, 7.4, 7.4); Calibrated: 2025/10/14 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn760; Calibrated: 2025/8/29 Phantom: SAM5; Type: SAM Twin; Serial: 1673 DASY52 52.10.4(1527); SEMCAD X 14.6.14(7483) Configuration/Scan/Area Scan (8x9x1): Measurement grid: dx=12mm, dy=12mm Maximum value of SAR (measured) = 0.740 W/kg Configuration/Scan/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 15.33 V/m; Power Drift = -0.18 dB Peak SAR (extrapolated) = 1.33 W/kg SAR(1 g) = 0.533 W/kg; SAR(10 g) = 0.223 W/kg Smallest distance from peaks to all points 3 dB below = 5.4 mm Ratio of SAR at M2 to SAR at M1 = 45.7% Maximum value of SAR (measured) = 0.945 W/kg 0 dB = 0.740 W/kg = -1.31 dBW/kg -End of the Appendix-

RF Exposure Info

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZSAR-TRF-01-A03 Rev. A/0 Aug 16,2024 Report No.: SZCR251100528203 Page: 1 of 2 Appendix A Detailed System Check Results 1. System Performance Check System Performance Check 2450 MHz Head Date: 2025/12/19 Test Laboratory: SGS-SAR Lab Sys tem P erfor man ce C heck 2450MHz H ead DUT: D2450V2; Type: Dipole; Serial: 733 Communication System: UID 0, CW; Frequency: 2450 MHz;Duty Cycle: 1:1 Medium: HSL;Medium parameters used: f = 2450 MHz; σ = 1.807 S/m; ε r = 38.554; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY 5 Configuration: Probe: EX3DV4 - SN7821; ConvF(7.4, 7.4, 7.4); Calibrated: 2025/10/14 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn760; Calibrated: 2025/8/29 Phantom: SAM5; Type: SAM Twin; Serial: 1673 DASY52 52.10.4(1527); SEMCAD X 14.6.14(7483) Configuration/d=10mm, Pin=250mW/Area Scan (6x9x1): Measurement grid: dx=12mm, dy=12mm Maximum value of SAR (measured) = 18.5 W/kg Configuration/d=10mm, Pin=250mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 93.09 V/m; Power Drift = 0.00 dB Peak SAR (extrapolated) = 29.8 W/kg SAR(1 g) = 13.8 W/kg; SAR(10 g) = 6.35 W/kg Smallest distance from peaks to all points 3 dB below = 9 mm Ratio of SAR at M2 to SAR at M1 = 46.3% Maximum value of SAR (measured) = 23.6 W/kg 0 dB = 18.5 W/kg = 12.68 dBW/kg -End of the Appendix-

Test Report

承 認 書 SPECIFICATION FOR APPROVAL 客戶名稱 CUSTOMER : 客戶料號 CUSTOMER’S P/N : 料號 PART NUMBER : JHUN3216F245H08T 規格 DESCRIPTION : Chip Antenna 3216 L Ant 2.45G Type H08 版本 VERSION : V1.0 日期 ISSUE DATE : 2025/04/23 客 戶 承 認 CUSTOMER APPROVED 工 程 部 R&D CENTER 承 認 APPROVAL 確 認 CHECKED 製 作 DRAWN Ray Tennyson Snow 萬誠科技股份有限公司 OneWave Electronic Co., Ltd. 11261台北市北投區立功街151號1樓 1F, No. 151, Li Gong Street, Beitou District, Taipei City 11261, Taiwan 電話: (02) 2898-2220 TEL: +886 2 2898-2220 傳真: (02) 2898-5055 FAX: +886 2 2898-5055 2/11 ONEWAVE TECHNOLOGY CO., LTD. 3216 Chip antenna For Bluetooth / WLAN Applications Dimension (mm) L 3.23 ± 0.20 W 1.66 ± 0.20 T 0.45 ± 0.20 P/N: JHUN3216F245H08T 3/11 ONEWAVE TECHNOLOGY CO., LTD. Part Number Information JHUN 3216 F 245 H 08 T A B C D E F G A Product Series Antenna B Dimension L x W 3.2 x 1.6mm (±0.2mm) C Material High K material D Working Frequency 2.4 ~ 2.5GHz E Feeding mode PIFA & Single Feeding F Antenna type Type = 08 G、H Internal Code 1. Electrical Specification Remark : Bandwidth & Peak Gain was measured under evaluation board of next page Specification Part Number JHUN3216F245H08T Central Frequency 2450 MHz Bandwidth 120 (Min.) MHz Return Loss -6.5 (Max) dB Peak Gain 1.75 dBi Impedance 50 Ohm Operating Temperature -40~+110 °C Maximum Power 4 W Resistance to Soldering Heats 10 ( @ 260°C) sec. Polarization Linear Azimuth Beamwidth Omni-directional Termination Cu / Sn (Leadless) 4/11 ONEWAVE TECHNOLOGY CO., LTD. 2. Recommended PCB Pattern Evaluation Board Dimension 2 nd Evaluation Board Dimension Suggested Matching Circuit 重要資訊 : 匹配元件建議使用精準度高的電感±0.1~0.3nH、電容±0.1pF 5/11 ONEWAVE TECHNOLOGY CO., LTD. Layout Dimensions in Clearance area( Size=5.9*5.0mm) FootPrint (Unit : mm) ◆ 2 nd Layout Dimensions in Clearance area( Size=8.0*3.0mm) Matching Circuit 50 ohm transmission Line 6/11 ONEWAVE TECHNOLOGY CO., LTD. 3. Measurement Results Return Loss 7/11 ONEWAVE TECHNOLOGY CO., LTD. Radiation Pattern Efficiency Peak Gain Directivity 2400MHz 81.46 % 1.67 dBi 2.56 dBi 2450MHz 84.75 % 1.75 dBi 2.46 dBi 2500MHz 82.68 % 1.70 dBi 2.52 dBi Chamber Coordinate System X Z Y 8/11 ONEWAVE TECHNOLOGY CO., LTD. 4.Reliability and Test Condictions ITEM REQUIREMENTS TEST CONDITION Solderability 1. Wetting shall exceed 90% coverage 2. No visible mechanical damage Pre-heating temperature:150°C/60sec. Solder temperature:230±5°C Duration:4±1sec. Solder:Sn-Ag3.0-Cu0.5 Flux for lead free: rosin Solder heat Resistance 1. No visible mechanical damage 2. Central Freq. change :within ± 6% 10±0.5 sec. 60sec .. TEMP (°C) 150°C 260°C Pre-heating temperature:150°C/60sec. Solder temperature:260±5°C Duration:10±0.5sec. Solder:Sn-Ag3.0-Cu0.5 Flux for lead free: rosin Component Adhesion (Push test) 1. No visible mechanical damage The device should be reflow soldered(230±5°C for 10sec.) to a tinned copper substrate A dynometer force gauge should be applied the side of the component. The device must with-ST-F 0.5 Kg without failure of the termination attached to component. Component Adhesion (Pull test) 1. No visible mechanical damage Insert 10cm wire into the remaining open eye bend ,the ends of even wire lengths upward and wind together. Terminal shall not be remarkably damaged. Thermal shock 1. No visible mechanical damage 2. Central Freq. change :within ±6% Phase Temperature(°C) Time(min) 1 +110±5°C 30±3 2 Room Temperature Within 3sec 3 -40±2°C 30±3 4 Room Temperature Within 3sec +110°C=>30±3min -40°C=>30±3min Test cycle:10 cycles The chip shall be stabilized at normal condition for 2~3 hours before measuring. Resistance to High Temperature 1. No visible mechanical damage 2. Central Freq. change :within ±6% 3. No disconnection or short circuit. Temperature: +110±5°C Duration: 1000±12hrs The chip shall be stabilized at normal condition for 2~3 hours before measuring. Resistance to Low Temperature 1. No visible mechanical damage 2. Central Freq. change :within ±6% 3. No disconnection or short circuit. Temperature:-40±5°C Duration: 1000±12hrs The chip shall be stabilized at normal condition for 2~3 hours before measuring. Humidity 1. No visible mechanical damage 2. Central Freq. change :within ±6% 3. No disconnection or short circuit. Temperature: 40±2°C Humidity: 90% to 95% RH Duration: 1000±12hrs The chip shall be stabilized at normal condition for 2~3 hours before measuring. 4±1 sec. 60sec TEMP (°C) 150°C 230°C 9/11 ONEWAVE TECHNOLOGY CO., LTD. 5.Soldering and Mounting Mildly activated rosin fluxes are preferred. The minimum amount of solder can lead to damage from the stresses caused by the difference in coefficients of expansion between solder, chip and substrate. The terminations are suitable for all wave and re-flow soldering systems. If hand soldering cannot be avoided, the preferred technique is the utilization of hot air soldering tools. Recommended temperature profiles for re-flow soldering in Figure 1. Products attachment with a soldering iron is discouraged due to the inherent process control limitations. In the event that a soldering iron must be employed the following precautions are recommended. ‧Preheat circuit and products to 150°C ‧Never contact the ceramic with the iron tip ‧Use a 20 watt soldering iron with tip diameter of 1.0mm ‧280°C tip temperature (max) ‧1.0mm tip diameter (max) ‧Limit soldering time to 3 sec. SOLDERING COOLING NATURAL PRE-HEATING TEMPERATURE(°C) 60~120 s 10s max. 30~60s 250~260 230 180 150 TIME(sec.) Reflow Soldering SOLDERING COOLING NATURAL PRE-HEATING TEMPERATURE(°C) within 3s Gradualcooling 150 TIME(sec.) Iron Soldering Over 60s 350 300 10/11 ONEWAVE TECHNOLOGY CO., LTD. 6.Packaging Information Tape Specification: Reel Specification: (7’’, Φ180 mm) Tape Width(mm) A(mm) B(mm) C(mm) D(mm) Chip/Reel(pcs) 8 9.0±0.5 60±2 13.5±0.5 178±2 3000 11/11 ONEWAVE TECHNOLOGY CO., LTD. 7.Storage and Transportation Information Storage Conditions To maintain the solderability of terminal electrodes: 1. Temperature and humidity conditions: -10~ 40°C and 30~70% RH. 2. Recommen…

Text truncated - open the document above for the full version.

Test Report

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/2 Report No.: SZCR251100528202 Page: 1 of 82 Keny Xu EMC Laboratory Manager TEST REPORT Application No.: SZCR2511005282AT Applicant: Razer Inc. Address of Applicant: 9 Pasteur, Irvine, California 92618 United States Manufacturer: Razer (Asia-Pacific) Pte. Ltd. Address of Manufacturer: Razer SEA HQ, 1 one-north Crescent, #02-01, 138538, Singapore Factory: RAZER TECHNOLOGY AND DEVELOPMENT (SHENZHEN) CO. LTD. Address of Factory: East Wing, 3 rd Floor, Block 2, Phase 1 of Vision Shenzhen Business Park Keji South Road, Hi-Tech Industrial Park, Shenzhen 518057, China Equipment Under Test (EUT): EUT Name: Charging case or XBOX Charging Case Model No.: 562C Trade Mark: RAZER FCC ID: RWO-562C Standard(s) : 47 CFR Part 15, Subpart C 15.247 Date of Receipt: 2025-11-28 Date of Test: 2025-12-12 to 2025-12-29 Date of Issue: 2025-12-31 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/2 Report No.: SZCR251100528202 Page: 2 of 82 Revision Record Version Chapter Date Modifier Remark 01 2025-12-31 Original Authorized for issue by: Charlie Dai/Project Engineer Eric Fu/Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/2 Report No.: SZCR251100528202 Page: 3 of 82 2 Test Summary Radio Spectrum Technical Requirement Item Standard Method Requirement Result Antenna Requirement 47 CFR Part 15, Subpart C 15.247 N/A 47 CFR Part 15, Subpart C 15.203 & 15.247(b)(4) Pass Other requirements Frequency Hopping Spread Spectrum System Hopping Sequence N/A 47 CFR Part 15, Subpart C 15.247(a)(1),(g),(h) Pass Radio Spectrum Matter Part Item Standard Method Requirement Result Conducted Emissions at AC Power Line (150kHz-30MHz) 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2020) Section 6.2 47 CFR Part 15, Subpart C 15.207 Pass Radiated Emissions which fall in the restricted bands ANSI C63.10 (2020) Section 6.10.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Spurious Emissions Below 1GHz ANSI C63.10 (2020) Section 6.4,6.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Spurious Emissions Above 1GHz ANSI C63.10 (2020) Section 6.6 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Conducted Peak Output Power ANSI C63.10 (2020) Section 7.8.5 47 CFR Part 15, Subpart C 15.247(b)(1) Pass 20dB Bandwidth ANSI C63.10 (2020) Section 6.9.2 47 CFR Part 15, Subpart C 15.247(a)(1) Pass Carrier Frequencies Separation ANSI C63.10 (2020) Section 7.8.2 47 CFR Part 15, Subpart C 15.247a(1) Pass Hopping Channel Number ANSI C63.10 (2020) Section 7.8.3 47 CFR Part 15, Subpart C 15.247a(1)(iii) Pass Dwell Time ANSI C63.10 (2020) Section 7.8.4 47 CFR Part 15, Subpart C 15.247a(1)(iii) Pass Conducted Band Edges Measurement ANSI C63.10 (2020) Section 7.8.7.2 47 CFR Part 15, Subpart C 15.247(d) Pass Conducted Spurious Emissions ANSI C63.10 (2020) Section 7.8.7 47 CFR Part 15, Subpart C 15.247(d) Pass SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/2 Report No.: SZCR251100528202 Page: 4 of 82 Remark: Model: 562C According to the manufacturer's declaration, the charging case contains 3 versions: the XBOX version, the PS version, and the PC version. The three versions are identical in terms of circuit design, PCB layout, components used, internal wiring and functions, with the only differences being in color and version label. The XBOX version is equipped with the Microsoft encryption chip UAB-X874203-001, whereas the other two versions (for PS and PC) do not have this chip. Based on the above, all test items were conducted on the XBOX version, while only the Radiated Emission test was performed on the PC version. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/2 Report No.: SZCR251100528202 Page: 5 of 82 3 Contents Page 1 Cover Page ................................................................................................................................................ 1 2 Test Summary ........................................................................................................................................... 3 3 Contents .................................................................................................................................................... 5 4 General Information .................................................................................................................................. 7 4.1 Details of E.U.T. ........................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Johnsen Tia(Associate VP, Regulatory & Compliance)
[email protected]Fax: 760 579 0182

Technical Contact

Razer Inc.Johnsen Tia
[email protected]Fax: 760 579 0182

9 Pasteur, Suite 100 · Irvine, California, 92618 · United States

Test Firm

SGS-CSTC Standards Technical Services Co., Ltd. ShKeny Xu
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz18.00 mW
Confidentiality
Long Term
Grant Notes
Power output listed is conducted. The antenna used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. SAR compliance for head operating conditions is limited to the specific configurations tested for this filing. End-users must be informed of the head operating requirements to satisfy RF exposure compliance. The highest reported SAR for Body-worn exposure condition is 0.64W/kg.

Other Applications from Razer Inc.

RWO-RZ060519

Gaming Controller

Sep 02, 2026

Equipment Class

DTS - Digital Transmission System
RWO-RZ010566

Gaming Mouse

Aug 26, 2026

Equipment Class

DTS - Digital Transmission System
RWO-RZ380426

Gaming Chair

Jun 26, 2026

Equipment Class

DTS - Digital Transmission System
RWO-DGRFG8

Wireless Dongle

May 28, 2026

Equipment Class

DTS - Digital Transmission System
RWO-RZ010569

Wireless Mouse

May 27, 2026

Equipment Class

DTS - Digital Transmission System