FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Razer Inc./
  3. RWO-HPD02

RWO-HPD02WIRELESS DONGLE

Razer Inc.

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Mar 25, 2026
Application Purpose
Original Equipment
Equipment Note
WIRELESS DONGLE
Frequency Range
2404.00000000 - 2478.00000000
Company
Razer Inc.
Country
United States

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Razer Inc. Doc nr. CERTIFICATIONS CONCERNING “COVERED” EQUIPMENT Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, Maryland 21046 2026.03.05 FCC ID: RWO-HPD02 To Whom It May Concern: As required by section 2.911(d)(5)(i), [Razer Inc.] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Razer Inc. certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). As required by section 2.911(d)(5)(ii), [Razer Inc.] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [is not] identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Thank you for your attention to this matter. Sincerely yours, Signature Printed Name: Johnsen Tia Company: Razer Inc. Job Title: Associate VP, Regulatory & Compliance Email: [email protected] Telephone: 760 579 0180

Attestation Statements

Rev 1/26/2023 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2025.04.16 Ref: Attestation Statements Part 2.911(d)(7) Filing Grantee Code: RWO Razer Inc. (“the applicant”) certifies that, as of the date of the filing of the application, we designate ourselves as the U.S. agent for service of process. Designated U.S. Agent Information: FRN: 0022386734 Name: Razer Inc. Address: 9 Pasteur Irvine, CA 92618 United States Contact Person: Johnsen Tia Tel.: 760 579 0180 Email: [email protected] Sincerely, _________________ Johnsen Tia (Associate VP. Regulatory & Compliance) [email protected]

Cover Letter(s)

Razer Inc. Declaration of Authorization We Name: Razer Inc. Address: 9 Pasteur City: Irvine State: California Country: United States Declare that: Name Representative of agent: Ms. Rose Liu Agent Company name: BTL Inc. Address: No.3 Jinshagang 1st Road, Shixia, Dalang Town City: Dong Guan Country: China is authorized to apply for Certification and signing related documents of the following product(s), including 731 form(s): Product description: WIRELESS DONGLE Type designation: HPD02 Trademark: RAZER FCC ID : RWO-HPD02 on our behalf. Date: 2026-03-05 City: Irvine Name: Johnsen Tia Function: Associate VP, Regulatory & Compliance Signature: . Notes: (1): Required for FCC application (2): For FCC it must be the Grantee Code “owner” or the authorized agent.

Cover Letter(s)

FCC, Request for non-disclosure Date: 02-01-2022 RF_501, Issue 10 Company Name: Razer Inc. Address: 9 Pasteur, City: Irvine, CA92618 Country: United States To: Kiwa Netherlands B.V., Dept. FCC TCB Wilmersdorf 50 7327 AC Apeldoorn The Netherlands Subject: Request for confidentiality FCC ID: RWO-HPD02 Reference number: ###### Dear FCC TCB, 1. Long-Term Confidentiality Pursuant to 47 CFR Section 0.459(a) & (b), we hereby requests non-disclosure and confidential treatment of the following materials submitted in support of FCC certification application: Bill(s) of Material Block Diagrams Operational Description Schematic Diagrams Tune-up Procedure Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. 2. Short-Term Confidentiality (STC) Pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, applicant hereby requests Short-Term Confidential treatment of the following materials (See notes below): Internal Photos User’s Manual Test Set-up Photos External Photos Justification: This document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor unfair advantage in the market. Planned Release Date STC: 180 days from date of grant (notes 2, 3, 4, 5) Date: 2026-03-05 Name and signature of applicant: Johnsen Tia Notes: 1) A document or type of document can only have ONE type of confidentiality! 2) Short-Term confidentiality is in principle for 45 days from date of grant; it can be extended max 3 times (total time 180 days max.)! The planned date should state in the RF731 application form. 3) FCC must be informed when marketing begins earlier. 4) Release takes place automatically thus extension must be requested in time. Telefication does not remind you of this! 5) Request for extension or for release must be received by Kiwa NL B.V. at least 7 days before date of actual marketing or before expiration of the STC period

ID Label/Location Info

CAN ICES (B) / NMB (B) Model No.[型号/型號]: HPD02 WIRELESS DONGLE Rating[ 额定/額定]: 5V 100mA FCC ID: RWO-HPD02 IC: 8092D-HPD02 201-250793 CCAHXXXXXXXXXX R-R-RAZ- HPD02 ©RAZER INC. Printing - High Gloss Black 2mm

RF Exposure Info

Report No.: BTL-FCCP-2-2510C221 Report Version: R00 Page 1 of 4 FCC RF EXPOSURE REPORT FCC ID: RWO-HPD02 Project No. : 2510C221 Equipment : WIRELESS DONGLE Brand Name : RAZER, Test Model : HPD02 Model Name : HPD02 Hardware Version : DVT2 Software Version : 1.0.9.0 Applicant : Razer Inc. Address : 9 Pasteur, Irvine, CA 92618, USA Manufacturer : RAZER (ASIA-PACIFIC) PTE. LTD. Address : Razer SEA HQ, 1 One-north Crescent, #02-01, Singapore 138538 Factory : RAZER TECHNOLOGY AND DEVELOPMENT (SHENZHEN) CO., LTD Address : East Wing, 3rd Floor, Block 2, Phase 1 of Vision Shenzhen Business Park Keji South Road, Hi-Tech Industrial Park, Shenzhen 518057, China Date of Receipt : Oct. 28, 2025 Date of Test : Oct. 29, 2025 ~ Jan. 12, 2026 Issued Date : Jan. 19, 2026 Test Sample : Engineering Sample No.: DG920251222338 Standard(s) : FCC Guidelines for Human Exposure IEEE C95.1 & KDB447498 D01 The above equipment has been tested and found compliance with the requirement of the relative standards by BTL Inc. (Dongguan) Prepared by : Evan Yang Approved by : Chay Cai No.3, Jinshagang 1st Road, Dalang, Dongguan, Guangdong People’s Republic of China. Tel: +86-769-8318-3000 Web: www.newbtl.com Service mail: [email protected] Report No.: BTL-FCCP-2-2510C221 Report Version: R00 Page 2 of 4 REVISION HISTORY Report No. Version Description Issued Date Note BTL-FCCP-2-2510C221 R00 Original Report. Jan. 19, 2026 Valid Report No.: BTL-FCCP-2-2510C221 Report Version: R00 Page 3 of 4 1. GENERAL CONCULUSION According to FCC KDB447498 D01, Appendix A, SAR Test Exclusion Thresholds for 100 MHz – 6 GHz and ≤ 50 mm, the 1-g and 10-g SAR test exclusion thresholds are determined by the following: [(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR, and ≤ 7.5 for 10-g extremity SAR, where  f(GHz) is the RF channel transmit frequency in GHz  Power and distance are rounded to the nearest mW and mm before calculation  The result is rounded to one decimal place for comparison Appendix A - SAR Test Exclusion Thresholds for 100 MHz - 6 GHz and < 50 mm MHz 5 10 15 20 25 30 35 40 45 50 mm 150 39 77 116 155 194 232 271 310 349 387 SAR Test Exclusion Thresholds (mW) 300 27 55 82 110 137 164 192 219 246 274 450 22 45 67 89 112 134 157 179 201 224 835 16 33 49 66 82 98 115 131 148 164 900 16 32 47 63 79 95 111 126 142 158 1500 12 24 37 49 61 73 86 98 110 122 1900 11 22 33 44 54 65 76 87 98 109 2450 10 19 29 38 48 57 67 77 86 96 3600 8 16 24 32 40 47 55 63 71 79 5200 7 13 20 26 33 39 46 53 59 66 5400 6 13 19 26 32 39 45 52 58 65 5800 6 12 19 25 31 37 44 50 56 62 Report No.: BTL-FCCP-2-2510C221 Report Version: R00 Page 4 of 4 2. TABLE FOR FILED ANTENNA Ant. Brand Model Antenna Type Connector Gain (dBi) 1 RAZER HPD02 PCB N/A 0.88 Note: The antenna gain is provided by the manufacturer. 3. TEST RESULTS Function Freq. (MHz) Max. Output Power (dBm) Max. Output Power (mW) Exclusion Thresholds Limit Result 2.4G SRD 2478 4.55 2.8510 0.8976 7.5 Pass Note: (1) No SAR evaluation required since transmitter power is below FCC threshold. (2) This product is for use on the limbs only. End of Test Report

Test Report

Report No.: BTL-FCCP-1-2510C221 Report Version: R00 Page 1 of 65 FCC Radio Test Report FCC ID: RWO-HPD02 This report concerns: Original Grant Project No. : 2510C221 Equipment : WIRELESS DONGLE Brand Name : RAZER, Model Name : HPD02 Applicant : Razer Inc. Address : 9 Pasteur, Irvine, CA 92618, USA Manufacturer : RAZER (ASIA-PACIFIC) PTE. LTD. Address : Razer SEA HQ, 1 One-north Crescent, #02-01, Singapore 138538 Factory : RAZER TECHNOLOGY AND DEVELOPMENT (SHENZHEN) CO., LTD Address : East Wing, 3rd Floor, Block 2, Phase 1 of Vision Shenzhen Business Park Keji South Road, Hi-Tech Industrial Park, Shenzhen 518057, China Date of Receipt : Oct. 28, 2025 Date of Test : Oct. 29, 2025 ~ Jan. 12, 2026 Issued Date : Jan. 19, 2026 Test Sample : Engineering Sample No.: DG920251222338 for power, DG920251028156 for other conducted, DG92025102969 and DG920251222339 for AC power line conducted emissions and radiated. Standard(s) : FCC CFR Title 47, Part 15, Subpart C The above equipment has been tested and found compliance with the requirement of the relative standards by BTL Inc. (Dongguan) Prepared by : Evan Yang Approved by : Chay Cai No.3, Jinshagang 1st Road, Dalang, Dongguan, Guangdong People’s Republic of China. Te l : + 8 6-769-8318-3000 Web: www.newbtl.com Service mail: [email protected] Report No.: BTL-FCCP-1-2510C221 Report Version: R00 Page 2 of 65 Declaration BTL represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with standards traceable to international standard(s) and/or national standard(s). BTL's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. BTL assumes no responsibility for the data provided by the customer, any statements, inferences or generalizations drawn by the customer or others from the reports issued by BTL. The report must not be used by the client to claim product certification, approval, or endorsement by A2LA or any agency of the U.S. Government. This report is the confidential property of the client. As a mutual protection to the clients, the public and ourselves, the test report shall not be reproduced, except in full, without our written approval. BTL’s laboratory quality assurance procedures are in compliance with the ISO/IEC 17025: 2017 requirements, and accredited by the conformity assessment authorities listed in this test report. BTL is not responsible for the sampling stage, so the results only apply to the sample as received. The information, data and test plan are provided by manufacturer which may affect the validity of results, so it is manufacturer’s responsibility to ensure that the apparatus meets the essential requirements of applied standards and in all the possible configurations as representative of its intended use. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Please note that the measurement uncertainty is provided for informational purpose only and are not use in determining the Pass/Fail results. Report No.: BTL-FCCP-1-2510C221 Report Version: R00 Page 3 of 65 Table of Contents Page REVISION HISTORY 6 1 . APPLICABLE STANDARDS 7 2 . SUMMARY OF TEST RESULTS 7 2.1 TEST FACILITY 8 2.2 MEASUREMENT UNCERTAINTY 8 2.3 TEST ENVIRONMENT CONDITIONS 9 3 . GENERAL INFORMATION 10 3.1 GENERAL DESCRIPTION OF EUT 10 3.2 DESCRIPTION OF TEST MODES 11 3.3 PARAMETERS OF TEST SOFTWARE 12 3.4 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 13 3.5 SUPPORT UNITS 13 3.6 CUSTOMER INFORMATION DESCRIPTION 13 4 . AC POWER LINE CONDUCTED EMISSIONS 14 4.1 LIMIT 14 4.2 TEST PROCEDURE 14 4.3 DEVIATION FROM TEST STANDARD 14 4.4 TEST SETUP 15 4.5 EUT OPERATING CONDITIONS 15 4.6 TEST RESULTS 15 5 . RADIATED EMISSIONS 16 5.1 LIMIT 16 5.2 TEST PROCEDURE 17 5.3 DEVIATION FROM TEST STANDARD 18 5.4 TEST SETUP 18 5.5 EUT OPERATING CONDITIONS 20 5.6 TEST RESULT - 9 KHZ TO 30 MHZ 20 5.7 TEST RESULT - 30 MHZ TO 1000 MHZ 20 5.8 TEST RESULT - ABOVE 1000 MHZ 20 6 . BANDWIDTH 21 6.1 LIMIT 21 Report No.: BTL-FCCP-1-2510C221 Report Version: R00 Page 4 of 65 Table of Contents Page 6.2 TEST PROCEDURE 21 6.3 DEVIATION FROM STANDARD 21 6.4 TEST SETUP 21 6.5 EUT OPERATION CONDITIONS 21 6.6 TEST RESULTS 21 7 . MAXIMUM OUTPUT POWER 22 7.1 LIMIT 22 7.2 TEST PROCEDURE 22 7.3 DEVIATION FROM STANDARD 22 7.4 TEST SETUP 22 7.5 EUT OPERATION CONDITIONS 22 7.6 TEST RESULTS 22 8 . CONDUCTED SPURIOUS EMISSION 23 8.1 LIMIT 23 8.2 TEST PROCEDURE 23 8.3 DEVIATION FROM STANDARD 24 8.4 TEST SETUP 24 8.5 EUT OPERATION CONDITIONS 24 8.6 TEST RESULTS 24 9 . POWER SPECTRAL DENSITY 25 9.1 LIMIT 25 9.2 TEST PROCEDURE 25 9.3 DEVIATION FROM STANDARD 25 9.4 TEST SETUP 25 9.5 EUT OPERATION CONDITIONS 25 9.6 TEST RESULTS 25 10 . MEASUREMENT INSTRUMENTS LIST 26 APPENDIX A - AC POWER LINE CONDUCTED EMISSIONS 28 APPENDIX B - RADIATED EMISSION - 9 KHZ TO 30 MHZ 31 APPENDIX C - RADIATED EMISSION - 30 MHZ TO 1000 MHZ 36 APPENDIX D - RADIATED EMISSION - ABOVE 1000 MHZ 39 APPENDIX E - BANDWIDTH 56 Report No.: BTL-FCCP-1-2510C221 Report Version: R00 Page 5 of 65 Table of Contents Page APPENDIX F - MAXIMUM OUTPUT POWER 59 APPENDIX G - CONDUCTED SPURIOUS EMISSION 61 APPENDIX H - POWER SPECTRAL DENSITY 64 Report No.: BTL-FCCP-1-2510C221 Report Version: R00 Page 6 of 65 REVISION HISTORY Report No. Version Description Issued Date Note BTL-FCCP-1-2510C221 R00 Original Report. Jan. 19, 2026 Valid Report No.: BTL-FCCP-1-2510C221 Report Version: R00 Page 7 of 65 1. APPLICABLE STANDARDS According to the specifications of the manufacturer, the EUT must comply with the requirements of the following standard: ANSI C63.10-2020 The following reference test guidance is not within the scope of accredit…

Text truncated - open the document above for the full version.

Test Report

Report No.: BTL-OTA-1- 2510C221 Page 1 of 15 ANT Test Report Antenna Type: Metal antenna Report No.: BTL-OTA-1- 2510C221 Page 2 of 15 Project No. Product Type Brand Name : 2510C221 : WIRELESS DONGLE : RAZER, Test Model : HPD02 Date of Receipt : 2025-11-22 Date of Test : 2025-11-22 Issued Date : 2025-11-25 Report Version : R00 Applicant : Razer Inc. Address : 9 Pasteur, Irvine, CA 92618, USA Manufacturer : RAZER (ASIA-PACIFIC) PTE. LTD. Address : Razer SEA HQ, 1 One-north Crescent, #02-01, Singapore 138538 The above equipment has been tested and found compliance with the requirement of the relative standards by BTL Inc.(Dongguan). Prepared by : Approved by : No.3, Jinshagang 1st Road, Dalang, Dongguan, Guangdong, China. Tel: +86-769-8318-3000 Web: www.newbtl.com Service mail: [email protected] Report No.: BTL-OTA-1- 2510C221 Page 3 of 15 Table of Contents REPORT ISSUED HISTORY ........................................................................................... 4 1 . PHYSICAL LAYOUT AND SITE DESCRIPTION ....................................................... 6 1.1 WIRELESS MOBILE DEVICE TEST LABORATORY .......................................................................... 6 1.2 ANECHOIC CHAMBER ........................................................................................................................ 6 1.3 MULTI AXIS POSITIONING SYSTEM (MAPS™) ................................................................................ 6 1.4 QUIET ZONE ........................................................................................................................................ 7 1.5 EMCO MODEL 3165-01 ABSORBER NESTED DUAL-POLARIZED DUAL-VIVALDI ARRAY ANTENNA 7 1.6 EMCO-3102 CIRCULARLY POLARIZED COMMUNICATION ANTENNAS ....................................... 7 1.7 TEST EQUIPMENT .............................................................................................................................. 7 1.8 EMQUEST SOFTWARE ....................................................................................................................... 7 TEMPERATURE, HUMIDITY .......................................................................................... 7 2 . TEST EQUIPMENT LIST .......................................................................................... 13 2.1 TEST EQUIPMENT USED FOR MEASURING .................................................................................. 13 3 . PHOTOGRAPH ........................................................................................................ 15 3.1 EUT SETUP PHOTO .......................................................................................................................... 15 Report No.: BTL-OTA-1- 2510C221 Page 4 of 15 REPORT ISSUED HISTORY Report No. Version Description Issued Date Note BTL-OTA-1-2510C221 R00 Original Report. 2025-11-25 Valid Report No.: BTL-OTA-1-2510C221 Page 5 of 15 Declaration BTL represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with standards traceable to international standard(s) and/or national standard(s). BTL's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. BTL assumes no responsibility for the data provided by the customer, any statements, inferences or generalizations drawn by the customer or others from the reports issued by BTL. This report is the confidential property of the client. As a mutual protection to the clients, the public and ourselves, the test report shall not be reproduced, except in full, without our written approval. BTL’s laboratory quality assurance procedures are in compliance with the ISO/IEC 17025: 2017 requirements, and accredited by the conformity assessment authorities listed in this test report. BTL is not responsible for the sampling stage, so the results only apply to the sample as received. The information, data and test plan are provided by manufacturer which may affect the validity of results, so it is manufacturer’s responsibility to ensure that the apparatus meets the essential requirements of applied standards and in all the possible configurations as representative of its intended use. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Please note that the measurement uncertainty is provided for informational purpose only and are not use in determining the Pass/Fail results. Report No.: BTL-OTA-1-2510C221 Page 6 of 15 1. PHYSICAL LAYOUT AND SITE DESCRIPTION 1.1 WIRELESS MOBILE DEVICE TEST LABORATORY All tests were performed in BTL Inc. state-of-the-art Wireless Mobile Device Test Laboratory consisting of a rectangular anechoic chamber equipped with a multi-axis positioning system (MAPS), a dual polarized quad- ridge waveguide horn, and two EMCO-3102 circularly polarized communication antennas. A base station simulator is used to establish communication with the EUT and place it in the proper mode, and a spectrum analyzer and RF switch combination is used for measuring the signal from the EUT at each position and polarization. BTL Inc.’s EMQuest EMQ-100 Pattern Measurement Software is used for data acquisition, post- processing, and generation of the required output. 1.2 ANECHOIC CHAMBER The anechoic chamber is a rectangular anechoic chamber designed and built by ETS-Lindgren with the following nominal dimensions。 Length: 5.1 m (200 in) Width: 5.1 m (200 in) Height: 5.1 m (200 in) The anechoic chamber consists of a shielded enclosure constructed of rigid, steel-clad, wood core modular panels with steel framing. The chamber is treated with ETS-Lindgren’s microwave absorber, utilizi…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Johnsen Tia(Associate VP, Regulatory & Compliance)
[email protected]Fax: 760 579 0182

Technical Contact

Razer Inc.Johnsen Tia
[email protected]Fax: 6565052199

9 Pasteur Irvine, · 92618 · United States

Test Firm

BTL Inc. (Dongguan)Sophia Huang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.90 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. End-users must be informed of transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Razer Inc.

RWO-RZ060519

Gaming Controller

Sep 02, 2026

Equipment Class

DTS - Digital Transmission System
RWO-RZ010566

Gaming Mouse

Aug 26, 2026

Equipment Class

DTS - Digital Transmission System
RWO-RZ380426

Gaming Chair

Jun 26, 2026

Equipment Class

DTS - Digital Transmission System
RWO-DGRFG8

Wireless Dongle

May 28, 2026

Equipment Class

DTS - Digital Transmission System
RWO-RZ010569

Wireless Mouse

May 27, 2026

Equipment Class

DTS - Digital Transmission System