FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Razer Inc./
  3. RWO-RZ010563

RWO-RZ010563Gaming Mouse

Razer Inc.

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Mar 25, 2026
Application Purpose
Original Equipment
Equipment Note
Gaming Mouse
Frequency Range
2404.00000000 - 2478.00000000
Company
Razer Inc.
Country
United States

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

ID Label/Location Info

↗
↗

RF Exposure Info

↗
↗
↗
↗
↗
↗
↗
↗

Test Report

↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

RF Exposure Info

Report No.: BTL-FCC SAR-1-2510C066_Appendix B. Page 1 of 1 Measurement Report for W08_2.4G SRD_CH2478_Back Side_0mm (2478.000MHz) Device under Test Properties Model, Manufacturer Dimensions [mm] IMEI DUT Type Device, 128.0 x 65.0 x 45.0 Mouse Exposure Conditions Phantom Section, TSL Position, Test Distance [mm] Band Group, UID Frequency [MHz], Channel Number Conversion Factor TSL Conductivity [S/m] TSL Permittivity Flat, Head Simulating Liquid BACK, 0.00 ISM 2.4 GHz Band Bluetooth, 10038- 2478.000, 76 7.29 1.88 38.9 Hardware Setup Phantom TSL, Measured Date Probe, Calibration Date DAE, Calibration Date ELI V5.0 (20deg probe tilt) - 1128 2300-2700 EX3DV4 - SN7693, 2025-11-26 DAE4 Sn1390, 2025-11-19 Scan Setup Area Scan Zoom Scan Grid Extents [mm] 100.0 x 160.0 32.0 x 32.0 x 30.0 Grid Steps [mm] 10.0 x 10.0 8.0 x 8.0 x 5.0 Sensor Surface [mm] 1.4 1.4 Graded Grid N/A Ye s Grading Ratio N/A 1.5 MAIA Y Y Surface Detection VMS + 6p VMS + 6p Scan Method Measured Measured Measurement Results Area Scan Zoom Scan Date 2026-01-06 2026-01-06 psSAR1g [W/kg] 0.054 0.053 psSAR10g [W/kg] 0.028 0.027 Power Drift [dB] 0.02 0.01 Power Scaling Disabled Disabled Scaling Factor [dB] TSL Correction No correction No correction M2/M1 [%] 76.7 Dist 3dB Peak [mm] 9.9

Test Report

Report No.: BTL-OTA-1-2510C066 Page 1 of 15 ANT Test Report Antenna Type: Metal Stamped Antenna Report No.: BTL-OTA-1-2510C066 Page 2 of 15 Project No. Product Type Brand Name : 2510C066 : Gaming Mouse : RAZER, Test Model : RZ01-0563 Date of Receipt : 2025-11-22 Date of Test : 2025-11-22 Issued Date : 2025-11-25 Report Version : R00 Applicant : Razer Inc. Address : 9 Pasteur, Irvine, CA 92618, USA Manufacturer : RAZER (ASIA-PACIFIC) PTE. LTD. Address : Razer SEA HQ, 1 One-north Crescent, #02-01, Singapore 138538 The above equipment has been tested and found compliance with the requirement of the relative standards by BTL Inc.(Dongguan). Prepared by : Approved by : No.3, Jinshagang 1st Road, Dalang, Dongguan, Guangdong, China. Tel: +86-769-8318-3000 Web: www.newbtl.com Service mail: [email protected] Report No.: BTL-OTA-1-2510C066 Page 3 of 15 Table of Contents REPORT ISSUED HISTORY ........................................................................................... 4 1 . PHYSICAL LAYOUT AND SITE DESCRIPTION ....................................................... 6 1.1 WIRELESS MOBILE DEVICE TEST LABORATORY .......................................................................... 6 1.2 ANECHOIC CHAMBER ........................................................................................................................ 6 1.3 MULTI AXIS POSITIONING SYSTEM (MAPS™) ................................................................................ 6 1.4 QUIET ZONE ........................................................................................................................................ 7 1.5 EMCO MODEL 3165-01 ABSORBER NESTED DUAL-POLARIZED DUAL-VIVALDI ARRAY ANTENNA 7 1.6 EMCO-3102 CIRCULARLY POLARIZED COMMUNICATION ANTENNAS ....................................... 7 1.7 TEST EQUIPMENT .............................................................................................................................. 7 1.8 EMQUEST SOFTWARE ....................................................................................................................... 7 TEMPERATURE, HUMIDITY .......................................................................................... 7 2 . TEST EQUIPMENT LIST .......................................................................................... 13 2.1 TEST EQUIPMENT USED FOR MEASURING .................................................................................. 13 3 . PHOTOGRAPH ........................................................................................................ 15 3.1 EUT SETUP PHOTO .......................................................................................................................... 15 Report No.: BTL-OTA-1-2510C066 Page 4 of 15 REPORT ISSUED HISTORY Report No. Version Description Issued Date Note BTL-OTA-1-2510C066 R00 Original Report. 2025-11-25 Valid Report No.: BTL-OTA-1-2510C066 Page 5 of 15 Declaration BTL represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with standards traceable to international standard(s) and/or national standard(s). BTL's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. BTL assumes no responsibility for the data provided by the customer, any statements, inferences or generalizations drawn by the customer or others from the reports issued by BTL. This report is the confidential property of the client. As a mutual protection to the clients, the public and ourselves, the test report shall not be reproduced, except in full, without our written approval. BTL’s laboratory quality assurance procedures are in compliance with the ISO/IEC 17025: 2017 requirements, and accredited by the conformity assessment authorities listed in this test report. BTL is not responsible for the sampling stage, so the results only apply to the sample as received. The information, data and test plan are provided by manufacturer which may affect the validity of results, so it is manufacturer’s responsibility to ensure that the apparatus meets the essential requirements of applied standards and in all the possible configurations as representative of its intended use. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Please note that the measurement uncertainty is provided for informational purpose only and are not use in determining the Pass/Fail results. Report No.: BTL-OTA-1-2510C066 Page 6 of 15 1. PHYSICAL LAYOUT AND SITE DESCRIPTION 1.1 WIRELESS MOBILE DEVICE TEST LABORATORY All tests were performed in BTL Inc. state-of-the-art Wireless Mobile Device Test Laboratory consisting of a rectangular anechoic chamber equipped with a multi-axis positioning system (MAPS), a dual polarized quad- ridge waveguide horn, and two EMCO-3102 circularly polarized communication antennas. A base station simulator is used to establish communication with the EUT and place it in the proper mode, and a spectrum analyzer and RF switch combination is used for measuring the signal from the EUT at each position and polarization. BTL Inc.’s EMQuest EMQ-100 Pattern Measurement Software is used for data acquisition, post- processing, and generation of the required output. 1.2 ANECHOIC CHAMBER The anechoic chamber is a rectangular anechoic chamber designed and built by ETS-Lindgren with the following nominal dimensions。 Length: 5.1 m (200 in) Width: 5.1 m (200 in) Height: 5.1 m (200 in) The anechoic chamber consists of a shielded enclosure constructed of rigid, steel-clad, wood core modular panels with steel framing. The chamber is treated with ETS-Lindgren’s microwave absorber, ut…

Text truncated - open the document above for the full version.

Test Report

Report No.: BTL-OTA-1-2510C066 Page 15 of 15 3. PHOTOGRAPH 3.1 EUT SETUP PHOTO Free Space _ Front Face Free Space _ Front Face End of Test Report

Test Report

Report No.: BTL-FCCP-1-2510C066 Report Version: R01 Page 1 of 63 FCC Radio Test Report FCC ID: RWO-RZ010563 This report concerns: Original Grant Project No. : 2510C066 Equipment : Gaming Mouse Brand Name : RAZER, Model Name : RZ01-0563, RZ01-0563XXXX-XXXX (X can be 0-9 or A-Z) Applicant : Razer Inc. Address : 9 Pasteur, Irvine, CA 92618, USA Manufacturer : RAZER (ASIA-PACIFIC) PTE. LTD. Address : Razer SEA HQ, 1 One-north Crescent, #02-01, Singapore 138538 Factory : RAZER TECHNOLOGY AND DEVELOPMENT (SHENZHEN) CO., LTD Address : East Wing, 3rd Floor, Block 2, Phase 1 of Vision Shenzhen Business Park Keji South Road, Hi-Tech Industrial Park, Shenzhen 518057, China Date of Receipt : Oct. 28, 2025 Date of Test : Oct. 29, 2025 ~ Jan. 11, 2026 Issued Date : Jan. 26, 2026 Test Sample : Sample No.: DG92025102955 & DG920251219163 for AC power line conducted emissions and radiated emisisons, DG920251028152 & DG920251219162 for others. Standard(s) : FCC CFR Title 47, Part 15, Subpart C The above equipment has been tested and found compliance with the requirement of the relative standards by BTL Inc. (Dongguan) Prepared by : Evan Yang Approved by : Chay Cai No.3, Jinshagang 1st Road, Dalang, Dongguan, Guangdong People’s Republic of China. Te l : + 8 6-769-8318-3000 Web: www.newbtl.com Service mail: [email protected] Report No.: BTL-FCCP-1-2510C066 Report Version: R01 Page 2 of 63 Declaration BTL represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with standards traceable to international standard(s) and/or national standard(s). BTL's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. BTL assumes no responsibility for the data provided by the customer, any statements, inferences or generalizations drawn by the customer or others from the reports issued by BTL. The report must not be used by the client to claim product certification, approval, or endorsement by A2LA or any agency of the U.S. Government. This report is the confidential property of the client. As a mutual protection to the clients, the public and ourselves, the test report shall not be reproduced, except in full, without our written approval. BTL’s laboratory quality assurance procedures are in compliance with the ISO/IEC 17025: 2017 requirements, and accredited by the conformity assessment authorities listed in this test report. BTL is not responsible for the sampling stage, so the results only apply to the sample as received. The information, data and test plan are provided by manufacturer which may affect the validity of results, so it is manufacturer’s responsibility to ensure that the apparatus meets the essential requirements of applied standards and in all the possible configurations as representative of its intended use. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Please note that the measurement uncertainty is provided for informational purpose only and are not use in determining the Pass/Fail results. Report No.: BTL-FCCP-1-2510C066 Report Version: R01 Page 3 of 63 Table of Contents Page REVISION HISTORY 6 1 . APPLICABLE STANDARDS 7 2 . SUMMARY OF TEST RESULTS 7 2.1 TEST FACILITY 8 2.2 MEASUREMENT UNCERTAINTY 8 2.3 TEST ENVIRONMENT CONDITIONS 9 3 . GENERAL INFORMATION 10 3.1 GENERAL DESCRIPTION OF EUT 10 3.2 DESCRIPTION OF TEST MODES 11 3.3 PARAMETERS OF TEST SOFTWARE 12 3.4 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 13 3.5 SUPPORT UNITS 13 3.6 CUSTOMER INFORMATION DESCRIPTION 13 4 . AC POWER LINE CONDUCTED EMISSIONS 14 4.1 LIMIT 14 4.2 TEST PROCEDURE 14 4.3 DEVIATION FROM TEST STANDARD 14 4.4 TEST SETUP 15 4.5 EUT OPERATING CONDITIONS 15 4.6 TEST RESULTS 15 5 . RADIATED EMISSIONS 16 5.1 LIMIT 16 5.2 TEST PROCEDURE 17 5.3 DEVIATION FROM TEST STANDARD 18 5.4 TEST SETUP 18 5.5 EUT OPERATING CONDITIONS 20 5.6 TEST RESULT - 9 KHZ TO 30 MHZ 20 5.7 TEST RESULT - 30 MHZ TO 1000 MHZ 20 5.8 TEST RESULT - ABOVE 1000 MHZ 20 6 . BANDWIDTH 21 6.1 LIMIT 21 Report No.: BTL-FCCP-1-2510C066 Report Version: R01 Page 4 of 63 Table of Contents Page 6.2 TEST PROCEDURE 21 6.3 DEVIATION FROM STANDARD 21 6.4 TEST SETUP 21 6.5 EUT OPERATION CONDITIONS 21 6.6 TEST RESULTS 21 7 . MAXIMUM OUTPUT POWER 22 7.1 LIMIT 22 7.2 TEST PROCEDURE 22 7.3 DEVIATION FROM STANDARD 22 7.4 TEST SETUP 22 7.5 EUT OPERATION CONDITIONS 22 7.6 TEST RESULTS 22 8 . CONDUCTED SPURIOUS EMISSION 23 8.1 LIMIT 23 8.2 TEST PROCEDURE 23 8.3 DEVIATION FROM STANDARD 24 8.4 TEST SETUP 24 8.5 EUT OPERATION CONDITIONS 24 8.6 TEST RESULTS 24 9 . POWER SPECTRAL DENSITY 25 9.1 LIMIT 25 9.2 TEST PROCEDURE 25 9.3 DEVIATION FROM STANDARD 25 9.4 TEST SETUP 25 9.5 EUT OPERATION CONDITIONS 25 9.6 TEST RESULTS 25 10 . MEASUREMENT INSTRUMENTS LIST 26 APPENDIX A - AC POWER LINE CONDUCTED EMISSIONS 28 APPENDIX B - RADIATED EMISSION - 9 KHZ TO 30 MHZ 31 APPENDIX C - RADIATED EMISSION - 30 MHZ TO 1000 MHZ 36 APPENDIX D - RADIATED EMISSION - ABOVE 1000 MHZ 39 APPENDIX E - BANDWIDTH 54 Report No.: BTL-FCCP-1-2510C066 Report Version: R01 Page 5 of 63 Table of Contents Page APPENDIX F - MAXIMUM OUTPUT POWER 57 APPENDIX G - CONDUCTED SPURIOUS EMISSION 59 APPENDIX H - POWER SPECTRAL DENSITY 62 Report No.: BTL-FCCP-1-2510C066 Report Version: R01 Page 6 of 63 REVISION HISTORY Report No. Version Description Issued Date Note BTL-FCCP-1-2510C066 R00 Original Report. Jan. 19, 2026 Invalid BTL-FCCP-1-2510C066 R01 This report updated the antenna type. It is a revision of the report with serial number BTL-FCCP-1-2510C066 R00. This is a newly released report, replacing the BTL-FCCP-1-2510C066 R00 report. Jan. 26, 2026 Valid Report No.: BTL-FCCP-1-2510C066 Report …

Text truncated - open the document above for the full version.

RF Exposure Info

Dipole Internal Calibration Record Asset No.: E-434 Model No.: D2450V2 Serial No.: 919 Environmental 22.5°C, 57 % Original Cal.Date: April 22, 2024 Next Cal. Date: April 22, 2027 Standard List 1 IEC/IEEE 62209-1528:2020 Measurement Procedure For The Assessment Of Specific Absorption Rate Of Human Exposure To Radio Frequency Fields From Hand-Held And Body-Worn Wireless Communication Devices - Part 1528:Human Models,Instrumentation And Procedures(Frequency Range of 4 MHz to 10GHz) 2KDB865664SAR Measurement Requirements for 100 MHz to 6 GHz Equipment Information Equipment:Manufacturer:Model No.:Serial No.:Cal.Organization:Cal. Date: Power AmplifierMini-CircuitsZHL-42W+QA1333003N/A June 29, 2024 DC Source metterlteckIT6154006104126768201001N/A June 29, 2024 Vector Network AnalyzerAgilentE5071CMY46102965N/A January 11, 2025 Signal GeneratorAgilentN5172BMY53050758N/A January 11, 2025 Smart Power SensorR&SNRP18S101333N/A June 1, 2024 Dielectric Assessment SpeagDAK-3.51226N/A January 20, 2025 Directional CouplerWokenTS-PCC0M-050107090019N/A January 11, 2025 CouplerWoken0110A05601O-10COM5BNW1A2N/A January 12, 2025 Liquid ThermometerNscing EsYZ6021S/N/A November 24, 2024 Model NoFor Head Tissue D2450V2 ItemOriginal Cal. ResultVerified on 2025/4/15DeviationResult Impedance, transformed to feed point 55.3Ω+1.3jΩ55.09Ω+3.27Ω<5ΩPass Return Loss(dB)-25.7-25.444-1.0%Pass SAR Value for 1g(mW/g)13.612.7-6.6%Pass SAR Value for 10g(mW/g) 6.35.97-5.2%Pass Impedance Test-HeadReturn Loss-Head Validation Report for Head TSL Calibrator:Approver:

Attestation Statements

Rev 1/26/2023 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 16-Apr--2025 Ref: Attestation Statements Part 2.911(d)(7) Filing Grantee Code: RWO Razer Inc. (“the applicant”) certifies that, as of the date of the filing of the application, we designate ourselves as the U.S. agent for service of process. Designated U.S. Agent Information: FRN: 0022386734 Name: Address: Contact Person: Email: Tel.: Razer Inc. 9 Pasteur, Irvine, California, United States Johnsen Tia [email protected] 760 579 0180 Sincerely, ________________ Johnsen Tia Associate VP, Regulatory & Compliance

RF Exposure Info

Report No.: BTL-FCC SAR-1-2510C066_Appendix A. Page 1 of 1 Measurement Report for System Check(2450.000MHz) Device under Test Properties Model, Manufacturer Dimensions [mm] IMEI DUT Type Device, 50.0 x 10.0 x 8.0 SN:919 Dipole 2450MHz Exposure Conditions Phantom Section, TSL Position, Test Distance [mm] Band Group, UID Frequency [MHz], Channel Number Conversion Factor TSL Conductivity [S/m] TSL Permittivity Flat, Head Simulating Liquid 5, CW, 0- 2450.000, 0 7.29 1.85 38.9 Hardware Setup Phantom TSL, Measured Date Probe, Calibration Date DAE, Calibration Date ELI V5.0 (20deg probe tilt) - 1128 2300-2700 EX3DV4 - SN7693, 2025-11-26 DAE4 Sn1390, 2025-11-19 Scan Setup Area Scan Zoom Scan Grid Extents [mm] 40.0 x 80.0 30.0 x 30.0 x 30.0 Grid Steps [mm] 10.0 x 10.0 5.0 x 5.0 x 1.5 Sensor Surface [mm] 3.0 1.4 Graded Grid N/A Ye s Grading Ratio N/A 1.5 MAIA N/A N/A Surface Detection VMS + 6p VMS + 6p Scan Method Measured Measured Measurement Results Area Scan Zoom Scan Date 2026-01-06 2026-01-06 psSAR1g [W/kg] 5.83 5.48 psSAR10g [W/kg] 2.81 2.50 Power Drift [dB] -0.02 -0.10 Power Scaling Disabled Disabled Scaling Factor [dB] TSL Correction No correction No correction M2/M1 [%] 79.2 Dist 3dB Peak [mm] 10.0

RF Exposure Info

Report No.: BTL-FCC SAR-1-2510C066 Report Version: R01 Page 1 of 29 FCC SAR Test Report FCC ID: RWO-RZ010563 Project No. : 2510C066 Equipment : Gaming Mouse Brand Name : RAZER, Model Name : RZ01-0563, RZ01-0563XXXX-XXXX (X can be 0-9 or A-Z) Date of Receipt : Oct. 29, 2025 Date of Test : Jan. 06, 2026 ~ Jan. 08, 2026 Issued Date : Jan. 26, 2026 Test Sample : Sample No.: DG92025102966 Standard(s) : Please refer to page 2. Applicant : Razer Inc. Address : 9 Pasteur, Irvine, CA 92618, USA Manufacturer : RAZER (ASIA-PACIFIC) PTE. LTD. Address : Razer SEA HQ, 1 One-north Crescent, #02-01, Singapore 138538 Factory : RAZER TECHNOLOGY AND DEVELOPMENT (SHENZHEN) CO., LTD Address : East Wing, 3rd Floor, Block 2, Phase 1 of Vision Shenzhen Business Park Keji South Road, Hi-Tech Industrial Park, Shenzhen 518057, China The above equipment has been tested and found compliance with the requirement of the relative standards by BTL Inc. (Dongguan). Prepared by : Justin Huang Approved by : Herbort Liu No.3, Jinshagang 1st Road, Dalang, Dongguan, Guangdong People’s Republic of China. Te l : + 8 6-769-8318-3000 Web: www.newbtl.com Service mail: [email protected] Report No.: BTL-FCC SAR-1-2510C066 Report Version: R01 Page 2 of 29 Standard(s) : IEEE Std C95.1:2019 IEEE Standard for Safety Levels with Respect to Human Exposure to Electric, Magnetic, and Electromagnetic Fields, 0 kHz to 300 GHz IEEE Std 1528 TM -2013 IEEE Recommended Practice for Determining the Peak Spatial- Average Specific Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement Techniques IEC/IEEE 62209-1528:2020 Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Part 1528: Human models, instrumentation, and procedures (Frequency range of 4 MHz to 10 GHz) KDB447498 D04 Interim General RF Exposure Guidance v01 KDB865664 D01 SAR Measurement 100 MHz to 6 GHz v01r04 Test Method : KDB865664 D02 SAR Reporting v01r02 KDB690783 D01 SAR Listings on Grants v01r03 KDB248227 D01 802. 11 Wi-Fi SAR v02r02 Report No.: BTL-FCC SAR-1-2510C066 Report Version: R01 Page 3 of 29 Declaration BTL represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with standards traceable to international standard(s) and/or national standard(s). BTL's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. BTL assumes no responsibility for the data provided by the customer, any statements, inferences or generalizations drawn by the customer or others from the reports issued by BTL. The report must not be used by the client to claim product certification, approval, or endorsement by A2LA or any agency of the U.S. Government. This report is the confidential property of the client. As a mutual protection to the clients, the public and ourselves, the test report shall not be reproduced, except in full, without our written approval. BTL’s laboratory quality assurance procedures are in compliance with the ISO/IEC 17025: 2017 requirements, and accredited by the conformity assessment authorities listed in this test report. BTL is not responsible for the sampling stage, so the results only apply to the sample as received. The information, data and test plan are provided by manufacturer which may affect the validity of results, so it is manufacturer’s responsibility to ensure that the apparatus meets the essential requirements of applied standards and in all the possible configurations as representative of its intended use. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Please note that the measurement uncertainty is provided for informational purpose only and are not use in determining the Pass/Fail results. Report No.: BTL-FCC SAR-1-2510C066 Report Version: R01 Page 4 of 29 Table of Contents Page REVISION HISTORY 6 1 . GENERAL INFORMATION 7 1.1 STATEMENT OF COMPLIANCE 7 1.2 LABORATORY ENVIRONMENT 7 1.3 GENERAL DESCRIPTION OF EUT 8 1.4 MAIN TEST INSTRUMENTS 9 2 . RF EMISSIONS MEASUREMENT 10 2.1 TEST FACILITY 10 2.2 MEASUREMENT UNCERTAINTY 10 3 . SAR MEASUREMENTS SYSTEM CONFIGURATION 11 3.1 SAR MEASUREMENT SET-UP 11 3.1.1 TEST SETUP L AYOU T 11 3.2 DASY E-FIELD PROBE SYSTEM 12 3.2.1 PROBE SPECIFICATION 12 3.2.2 E-FIELD PROBE CALIBRATION 13 3.2.3 OTHER TEST EQUIPMENT 14 3.2.4 SCANNING PROCEDURE 15 3.2.5 SPATIAL PEAK SAR EVALUATION 16 3.2.6 DATA STORAGE AND EVALUATION 17 3.2.7 DATA EVALUATION BY SEMCAD 18 4 . SYSTEM VERIFICATION PROCEDURE 20 4.1 TISSUE VERIFICATION 20 4.2 SYSTEM CHECK 21 4.3 SYSTEM CHECK PROCEDURE 21 5 . SAR MEASUREMENT VARIABILITY AND UNCERTAINTY 22 5.1 SAR MEASUREMENT VARIABILITY 22 6 . OPERATIONAL CONDITIONS DURING TEST 23 6.1 TEST POSITION 23 6.2 TEST CONFIGURATION 24 6.2.1 WIFI TEST CONFIGURATION 24 7 . TEST RESULT 25 7.1 CONDUCTED POWER RESULTS 25 7.1.1 CONDUCTED POWER MEASUREMENTS 25 7.2 SAR TEST RESULTS 26 7.2.1 SAR MEASUREMENT RESULT 26 Report No.: BTL-FCC SAR-1-2510C066 Report Version: R01 Page 5 of 29 Table of Contents Page 8 MULTIPLE TRANSMITTER EVALUATION 27 APPENDIX 28 1. TEST LAYOUT 28 Appendix A. SAR Plots of System Verification Appendix B. SAR Plots of SAR Measurement Appendix C. Calibration Certificate Appendix D. Photographs of the Test Set-Up Report No.: BTL-FCC SAR-1-2510C066 Report Version: R01 Page 6 of 29 REVISION HISTORY Report No. Version Description Issued Date Note BTL-FCC SAR-1-2510C066 R00 Original Report. Jan. 19, 2026 Invalid BTL-FCC SAR-1-2510C066 R01 This report updated the antenna type. It is a revision of the report with serial number BTL-FCC SAR-…

Text truncated - open the document above for the full version.

ID Label/Location Info

POWER/DPIPOWER/DPIPOWER/DPI CAN ICES (B) / NMB (B) Model No.[型号/型號]: HPD02 WIRELESS DONGLE Rating[ 额定/額定]: 5V 100mA FCC ID: RWO-HPD02 IC: 8092D-HPD02 201-250793 CCAHXXXXXXXXXX R-R-RAZ- HPD02 ©RAZER INC. Razer F5, Reg, 5pt DUMMY S/No.: 63YYWWU197XXXXX P/No.[代号/代號]: RC30-05630100 SDDPI: XXXXXXXXXXXXXXX MADE IN THAILAND/泰国制造/泰國製造 DUMMY S/No.: PMYYWWU197XXXXX P/No.[代号/代號]: RC30-05630100 SDDPI: XXXXXXXXXXXXXXX MADE IN CHINA / 中国制造 / 中國製造 Razer F5, Reg, 5pt DUMMY S/No.: 63YYWWU198XXXXX P/No.[代号/代號]: RC30-05630200 SDDPI: XXXXXXXXXXXXXXX MADE IN THAILAND/泰国制造/泰國製造 DUMMY S/No.: PMYYWWU198XXXXX P/No.[代号/代號]: RC30-05630200 SDDPI: XXXXXXXXXXXXXXX MADE IN CHINA / 中国制造 / 中國製造 Model No.: RZ01-0563 Gaming Mouse P/No.: RZ01-05630X00 Rating: 5V 200mA MADE IN CHINA MADE IN THAILAND Serial No.: CMYYWW AAAAXXXXX Razer (Europe) GmbH Alter Teichweg 25,22081 Hamburg, Germany © RAZER INC. Model No.: RZ01-0563 Gaming Mouse P/No.: RZ01-0563X100 Rating: 5V 200mA CAN ICES (B) / NMB (B) Serial No.: CMYYWW AAAAXXXXX ANATEL ID: XXXXXXXX FCC ID: RWO-RZ010563 IC: 8092D-RZ010563 R-R-RAZ- RZ01-0563 R39212 RoHS 201-250791 MADE IN CHINA/ SDPPI: XXXXX/SDPPI/20XX CCAHXXXXXXXXXX © RAZER INC. Model No.[]: RZ01-0563 P/No. []: RZ01-0563X100 Rating []: 5V200mA Gaming mouse// Serial No.: CMYYWW AAAAXXXXX IFT: IMRARZ25-18504 SCALE 1:1 Winona T1 - Black + White - PID artworks Rev 2510__ by MH@Razer EU sku Serial Number Format: CMYYWWAAAAXXXXX CM= Contract Manufacturer (Primax Thailand) = 63 CM= Contract Manufacturer (Primax China)) = PM YY = year, 2026 =26 WW= work week when the product is final assembled and final tested (+/-2 weeks) AAAA = Product Serial code (assigned by Razer) = as chart below XXXXX = running serial numbers 流水號 十進位, start from 00001 Printing - High Gloss Black 2mm DONGLE Generic sku Change to “X” to: Black: P/No.: RZ01-05630100 White: P/No.: RZ01-05630200 P/No.: RZ01-05630X00 Change to “X” to: Black: P/No.: RZ01-05630100 White: P/No.: RZ01-05630200 P/No.: RZ01-05630X00 AP sku BlackWhite NASA sku Change to “X” to: Black: P/No.: RZ01-05630100 White: P/No.: RZ01-05630200 P/No.: RZ01-05630X00 DUMMY DUMMY DUMMY MIC --or-- MITH SN LABEL Size: 32.5 x 8.5mm High Gloss Molded Secondary laser etch print process Product Code EAN UPC Description Serial Code RC30-05630100-0000 N.A. N.A. Razer HyperSpeed Wireless Gen-2 Dongle for Razer Viper V4 Pro - Black (HPD01) U197 RC30-05630200-0000 N.A. N.A. Razer HyperSpeed Wireless Gen-2 Dongle for Razer Viper V4 Pro - White (HPD01) U198 RZ01-05630100-R3U1 888 79100 8512 7 840272923986 Razer Viper V4 Pro - Wireless Esports Gaming Mouse - NASA Packaging H376 RZ01-05630100-R3G1 888 79100 8513 4 N.A. Razer Viper V4 Pro - Wireless Esports Gaming Mouse - EU Packaging H377 RZ01-05630100-R3A1 888 79100 8514 1 N.A. Razer Viper V4 Pro - Wireless Esports Gaming Mouse - AP Packaging H378 RZ01-05630200-R3U1 888 79100 8515 8 840272923993 Razer Viper V4 Pro - Wireless Esports Gaming Mouse - White Edition - NASA Packaging H379 RZ01-05630200-R3G1 888 79100 8516 5 N.A. Razer Viper V4 Pro - Wireless Esports Gaming Mouse - White Edition - EU Packaging H380 RZ01-05630200-R3A1 888 79100 8517 2 N.A. Razer Viper V4 Pro - Wireless Esports Gaming Mouse - White Edition - AP Packaging H381

ID Label/Location Info

POWER/DPI MADE IN THAILAND Model No.: RZ01-0563 Gaming Mouse P/No.: RZ01-0563X100 Rating: 5V 200mA CAN ICES (B) / NMB (B) Serial No.: CMYYWW AAAAXXXXX ANATEL ID: XXXXXXXX FCC ID: RWO-RZ010563 IC: 8092D-RZ010563 IFT: IMRARZ25-18504 NASA sku Change to “X” to: Black: P/No.: RZ01-05630100 White: P/No.: RZ01-05630200 P/No.: RZ01-05630X00 DUMMY

Cover Letter(s)

Model Declaration Letter We, the undersigning company Company Name: Razer Inc. Address: 9 Pasteur, Irvine, CA 92618, USA Hereby confirm that the following products: Product description: Gaming Mouse Type designation: RZ01-0563, RZ01-0563XXXX-XXXX (X can be 0-9 or A-Z) Trademark: RAZER That All versions of the Model RZ01-0563, RZ01-0563XXXX-XXXX, are electrically equal except the following difference: Only differ in the model name. X can be 0-9 or A-Z Date: 2026-03-11 Name: Johnsen Tia Telephone: 65 6571 6828 E-mail: [email protected] Signature:

Cover Letter(s)

FCC, Request for non-disclosure Date: 02-01-2022 RF_501, Issue 10 Company Name: Razer Inc. Address: 9 Pasteur City: Irvine, CA92618 Country: United States To: Kiwa Netherlands B.V., Dept. FCC TCB Wilmersdorf 50 7327 AC Apeldoorn The Netherlands Subject: Request for confidentiality FCC ID: RWO-RZ010563 Reference number: ###### Dear FCC TCB, 1. Long-Term Confidentiality Pursuant to 47 CFR Section 0.459(a) & (b), we hereby requests non-disclosure and confidential treatment of the following materials submitted in support of FCC certification application: Bill(s) of Material Block Diagrams Operational Description Schematic Diagrams Tune-up Procedure Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. 2. Short-Term Confidentiality (STC) Pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, applicant hereby requests Short-Term Confidential treatment of the following materials (See notes below): Internal Photos User’s Manual Test Set-up Photos External Photos Justification: This document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor unfair advantage in the market. Planned Release Date STC: 180 days from date of grant (notes 2, 3, 4, 5) Date: 2026-03-11 Name and signature of applicant: Johnsen Tia Notes: 1) A document or type of document can only have ONE type of confidentiality! 2) Short-Term confidentiality is in principle for 45 days from date of grant; it can be extended max 3 times (total time 180 days max.)! The planned date should state in the RF731 application form. 3) FCC must be informed when marketing begins earlier. 4) Release takes place automatically thus extension must be requested in time. Telefication does not remind you of this! 5) Request for extension or for release must be received by Kiwa NL B.V. at least 7 days before date of actual marketing or before expiration of the STC period

Cover Letter(s)

Razer Inc. Declaration of Authorization We Name: Razer Inc. Address: 9 Pasteur City: Irvine State: California Country: United States Declare that: Name Representative of agent: Ms. Rose Liu Agent Company name: BTL Inc. Address: No.3 Jinshagang 1st Road, Shixia, Dalang Town City: Dong Guan Country: China is authorized to apply for Certification and signing related documents of the following product(s), including 731 form(s): Product description: Gaming Mouse Type designation: RZ01-0563, RZ01-0563XXXX-XXXX (X can be 0-9 or A-Z) Trademark: RAZER FCC ID : RWO-RZ010563 on our behalf. Date: 2026.03.11 City: Irvine Name: Johnsen Tia Function…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Johnsen Tia(Associate VP, Regulatory & Compliance)
[email protected]Fax: 760 579 0182

Technical Contact

Razer Inc.Johnsen Tia
[email protected]Fax: 65 6505 2199

9 Pasteur Irvine, CA 92618 United States · 92618 · United States

Test Firm

BTL Inc. (Dongguan)Sophia Huang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.40 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 0mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for stand-alone transmission exposure conditions is 0.20 W/kg, respectively.

Other Applications from Razer Inc.

RWO-RZ060519

Gaming Controller

Sep 02, 2026

Equipment Class

DTS - Digital Transmission System
RWO-RZ010566

Gaming Mouse

Aug 26, 2026

Equipment Class

DTS - Digital Transmission System
RWO-RZ380426

Gaming Chair

Jun 26, 2026

Equipment Class

DTS - Digital Transmission System
RWO-DGRFG8

Wireless Dongle

May 28, 2026

Equipment Class

DTS - Digital Transmission System
RWO-RZ010569

Wireless Mouse

May 27, 2026

Equipment Class

DTS - Digital Transmission System