Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Rev 1/26/2023 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 20-Feb--2023 Ref: Attestation Statements Part 2.911(d)(7) Filing Grantee Code: RWO Razer Inc. (“the applicant”) certifies that, as of the date of the filing of the application, we designate ourselves as the U.S. agent for service of process. Designated U.S. Agent Information: FRN: 0022386734 Name: Razer Inc. Address: 9 Pasteur, Suite 100, Irvine, California, United States Contact Person: Johnsen Tia Email: [email protected] Tel.: 760 579 0180 Sincerely, ________________ Johnsen Tia Senior Director, Regulatory & Compliance
Razer Inc. CERTIFICATIONS CONCERNING “COVERED” EQUIPMENT Date:2024-08-21 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, Maryland 21046 FCC ID: RWO-RZ030513 To Whom It May Concern: As required by section 2.911(d)(5)(i), [Razer Inc.] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. As required by section 2.911(d)(5)(ii), [Razer Inc.] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [is not] identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Thank you for your attention to this matter. Sincerely yours, Signature Printed Name: Johnsen Tia Company: Razer Inc. Job Title: Associate VP, Regulatory & Compliance Email: [email protected] Telephone: 760 579 0180
RF_160_05 Declaration of Authorisation Date of issue 02-01-2023 (Razer Inc.) Declaration of Authorization We Name: Razer Inc. Address: 9 Pasteur, Suite 100. City: Irvine, California Country: United States Declare that: Name Representative of agent: Ms. Rose Liu (1) Agent Company name: BTL Inc. Address: No.3 Jinshagang 1st Road, Shixia, Dalang Town City: Dong Guan Country China is authorized to apply for Certification of the following product(s): Product description: Gaming Keyboard Type designation: RZ03-0513, RZ03-0513XXXX-XXXX (X can be 0-9 or A-Z) Trademark: RAZER, Validity/ expiry date:2025-08-21 on our behalf. Date: 2024-08-21 City: Irvine Name: Johnsen Tia (2) Function: Associate VP, Regulatory & Compliance Signature: . Notes: (1): Required for FCC application (2): For FCC it must be the Grantee Code “owner” or the authorized agent.
FCC, Request for non-disclosure Date: 02-01-2022 RF_501, Issue 10 Company Name: Razer Inc. Address: 9 Pasteur, Suite 100 City: Irvine, California Country: United States To: Kiwa Netherlands B.V., Dept. FCC TCB Wilmersdorf 50 7327 AC Apeldoorn The Netherlands Subject: Request for confidentiality FCC ID: RWO-RZ030513 Reference number: ###### Dear FCC TCB, 1. Long-Term Confidentiality Pursuant to 47 CFR Section 0.459(a) & (b), we hereby requests non-disclosure and confidential treatment of the following materials submitted in support of FCC certification application: Bill(s) of Material Block Diagrams Operational Description Schematic Diagrams Tune-up Procedure Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. 2. Short-Term Confidentiality (STC) Pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, applicant hereby requests Short-Term Confidential treatment of the following materials (See notes below): Internal Photos User’s Manual Test Set-up Photos External Photos Justification: This document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor unfair advantage in the market. Date: 2024-08-21 Name and signature of applicant: Johnsen Tia Notes: 1) A document or type of document can only have ONE type of confidentiality! 2) Short-Term confidentiality is in principle for 45 days from date of grant; it can be extended max 3 times (total time 180 days max.)! The planned date should state in the RF731 application form. 3) FCC must be informed when marketing begins earlier. 4) Release takes place automatically thus extension must be requested in time. Telefication does not remind you of this! 5) Request for extension or for release must be received by Kiwa NL B.V. at least 7 days before date of actual marketing or before expiration of the STC period
Model Declaration Letter We, the undersigning company Company Name: Razer Inc. Address: 9 Pasteur, Suite 100, Irvine, California, United States, 92618 Hereby confirm that the following products: Product description: Gaming Mouse Type designation: RZ03-0513, RZ03-0513XXXX-XXXX (X can be 0-9 or A-Z) Trademark: RAZER, That All versions of the Model RZ03-0513 and RZ03-0513XXXX-XXXX (X can be 0-9 or A-Z); are electrically equal except the following difference: Only differ in the model name. The system’s model name is RZ03-0513XXXX-XXXX (X: Can be 0-9, A-Z), and the system contains a Gaming Keybord (Model name:RZ03-0513) and Wireless Dongle (Model name: HSD01). Date: 2024-08-21 Name: Johnsen Tia Telephone: 760 579 0180 E-mail: [email protected] Signature:
Report No.: BTL-FCC SAR-1-2401C209A Page 1 of 27 FCC SAR Test Report FCC ID: RWO-RZ030513 Project No. : 2401C209A Equipment : Gaming Keyboard Brand Name : RAZER, Test Model : RZ03-0513 Series Model : RZ03-0513XXXX-XXXX (X can be 0-9 or A-Z) Date of Receipt : Feb. 06, 2024 Date of Test : Mar. 23, 2024 ~ May 14, 2024 Issued Date : May 28, 2024 Report Version : R00 Test Sample : Engineering Sample No.: DG2024020680(US), DG20240507532(UK), DG20240507533(JP) Standard(s) : Please refer to page 2. Applicant : Razer Inc. Address : 9 Pasteur, Suite 100, Irvine, CA92618, USA Manufacturer : RAZER (ASIA-PACIFIC) PTE. LTD. Address : Razer SEA HQ, 1 One-north Crescent, #02-01, Singapore 138538 Factory : RAZER TECHNOLOGY AND DEVELOPMENT (SHENZHEN) CO., LTD Address : East Wing, 3rd Floor, Block 2, Phase 1 of Vision Shenzhen Business Park Keji South Road, Hi-Tech Industrial Park, Shenzhen 518057, China The above equipment has been tested and found compliance with the requirement of the relative standards by BTL Inc. Prepared by : Justin Huang Approved by : Herbort Liu Room 108, Building 2, No.1, Yile Road, Songshan Lake Zone, Dongguan City, Guangdong, People’s Republic of China. Te l : + 8 6-769-8318-3000 Web: www.newbtl.com Service mail: [email protected] Report No.: BTL-FCC SAR-1-2401C209A Page 2 of 27 Standard(s) : IEEE Std C95.1:2019 IEEE Standard for Safety Levels with Respect to Human Exposure to Electric, Magnetic, and Electromagnetic Fields, 0 kHz to 300 GHz EN IEC/IEEE 62209-1528:2021 Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Part 1528: Human models, instrumentation, and procedures (Frequency range of 4 MHz to 10 GHz) KDB447498 D04 Interim General RF Exposure Guidance v01 KDB865664 D01 SAR measurement 100 MHz to 6 GHz v01r04 KDB865664 D02 SAR Reporting v01r02 Report No.: BTL-FCC SAR-1-2401C209A Page 3 of 27 Declaration BTL represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with standards traceable to international standard(s) and/or national standard(s). BTL's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. BTL assumes no responsibility for the data provided by the customer, any statements, inferences or generalizations drawn by the customer or others from the reports issued by BTL. The report must not be used by the client to claim product certification, approval, or endorsement by A2LA or any agency of the U.S. Government. This report is the confidential property of the client. As a mutual protection to the clients, the public and ourselves, the test report shall not be reproduced, except in full, without our written approval. BTL’s laboratory quality assurance procedures are in compliance with the ISO/IEC 17025: 2017 requirements, and accredited by the conformity assessment authorities listed in this test report. BTL is not responsible for the sampling stage, so the results only apply to the sample as received. The information, data and test plan are provided by manufacturer which may affect the validity of results, so it is manufacturer’s responsibility to ensure that the apparatus meets the essential requirements of applied standards and in all the possible configurations as representative of its intended use. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Please note that the measurement uncertainty is provided for informational purpose only and are not use in determining the Pass/Fail results. Report No.: BTL-FCC SAR-1-2401C209A Page 4 of 27 Table of Contents Page REPORT ISSUED HISTORY 6 1 . GENERAL INFORMATION 7 1.1 STATEMENT OF COMPLIANCE 7 1.2 LABORATORY ENVIRONMENT 7 1.3 GENERAL DESCRIPTION OF EUT 7 1.4 MAIN TEST INSTRUMENTS 8 2 . RF EMISSIONS MEASUREMENT 9 2.1 TEST FACILITY 9 2.2 MEASUREMENT UNCERTAINTY 9 3 . SAR MEASUREMENTS SYSTEM CONFIGURATION 10 3.1 SAR MEASUREMENT SET-UP 10 3.1.1 TEST SETUP LAYOUT 10 3.2 DASY5 E-FIELD PROBE SYSTEM 11 3.2.1 PROBE SPECIFICATION 11 3.2.2 E-FIELD PROBE CALIBRATION 12 3.2.3 OTHER TEST EQUIPMENT 13 3.2.4 SCANNING PROCEDURE 14 3.2.5 SPATIAL PEAK SAR EVALUATION 15 3.2.6 DATA STORAGE AND EVALUATION 16 3.2.7 DATA EVALUATION BY SEMCAD 17 4 . SYSTEM VERIFICATION PROCEDURE 19 4.1 TISSUE VERIFICATION 19 4.2 SYSTEM CHECK 20 4.3 SYSTEM CHECK PROCEDURE 20 5 . SAR MEASUREMENT VARIABILITY AND UNCERTAINTY 21 5.1 SAR MEASUREMENT VARIABILITY 21 6 . OPERATIONAL CONDITIONS DURING TEST 22 6.1 TEST POSITION 22 6.2 TEST CONFIGURATION 22 7 . TEST RESULT 23 7.1 CONDUCTED POWER RESULTS 23 7.1.1 CONDUCTED POWER MEASUREMENTS OF BT 23 7.1.2 CONDUCTED POWER MEASUREMENTS OF 2.4G SRD 23 7.2 SAR TEST RESULTS 24 Report No.: BTL-FCC SAR-1-2401C209A Page 5 of 27 Table of Contents Page 7.2.1 SAR MEASUREMENT RESULT 24 8 MULTIPLE TRANSMITTER EVALUATION 25 APPENDIX 26 1. TEST LAYOUT 26 Appendix A. SAR Plots of System Verification Appendix B. SAR Plots of SAR Measurement Appendix C. Calibration Certificate Appendix D. Photographs of the Test Set-Up Report No.: BTL-FCC SAR-1-2401C209A Page 6 of 27 REPORT ISSUED HISTORY Report No. Version Description Issued Date Note BTL-FCC SAR-1-2401C209A R00 Original Report. May 28, 2024 Valid Report No.: BTL-FCC SAR-1-2401C209A Page 7 of 27 1. GENERAL INFORMATION 1.1 STATEMENT OF COMPLIANCE Mode Highest Reported Extremity SAR-1g (W/kg) 2.4G SRD 0.375 BLE 0.375 Note: The device is in compliance with Specific Absorption Rate (SAR) for general population uncontrolled exposure limits according to the FCC rule §2.1093, the ANSI C95.1:1992/IEEE C95.1:1991, the NCRP Report Number 86 …
Text truncated - open the document above for the full version.
Report No.: BTL-FCC SAR-1-2401C209A_Appendix A. Page 1 of 2 Test Laboratory: BTL Inc. Date: 2024/3/23 System Check_H2450_0323 DUT: Dipole 2450 MHz D2450V2;SN:919; Communication System: UID 0, CW (0); Frequency: 2450 MHz; Duty Cycle: 1:1 Medium parameters used: f = 2450 MHz; σ = 1.823 S/m; ε r = 40.97; ρ = 1000 kg/m 3 Ambient Temperature:22.4°C; Liquid Temperature:21.5 °C DASY Configuration: • Probe: EX3DV4 - SN7693; ConvF(8.33, 8.33, 8.33) @ 2450 MHz; Calibrated: 2023/10/31 • Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 Sn1390; Calibrated: 2023/11/20 • Phantom: ELI v5.0_Left; Type: QDOVA002AA; Serial: TP:1222 • DASY52 52.10.2(1495); SEMCAD X 14.6.12(7450) Area Scan (8x9x1): Measurement grid: dx=12mm, dy=12mm Maximum value of SAR (measured) = 17.7 W/kg Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 114.5 V/m; Power Drift = -0.01 dB Peak SAR (extrapolated) = 26.2 W/kg SAR(1 g) = 12.9 W/kg; SAR(10 g) = 6.12 W/kg Maximum value of SAR (measured) = 21.0 W/kg Report No.: BTL-FCC SAR-1-2401C209A_Appendix A. Page 2 of 2 Test Laboratory: BTL Inc. Date: 2024/5/14 System Check_H2450_0514 DUT: Dipole 2450 MHz D2450V2;SN:919; Communication System: UID 0, CW (0); Frequency: 2450 MHz; Duty Cycle: 1:1 Medium parameters used (interpolated): f = 2450 MHz; σ = 1.836 S/m; ε r = 39.639; ρ = 1000 kg/m 3 Ambient Temperature:22.8°C; Liquid Temperature:21.9 °C DASY Configuration: • Probe: EX3DV4 - SN7515; ConvF(7.45, 7.45, 7.45) @ 2450 MHz; Calibrated: 2023/12/14 • Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 Sn1390; Calibrated: 2023/11/20 • Phantom: ELI v5.0_Left; Type: QDOVA002AA; Serial: TP:1222 • DASY52 52.10.2(1495); SEMCAD X 14.6.12(7450) Area Scan (8x9x1): Measurement grid: dx=12mm, dy=12mm Maximum value of SAR (measured) = 17.8 W/kg Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 114.5 V/m; Power Drift = -0.01 dB Peak SAR (extrapolated) = 26.4 W/kg SAR(1 g) = 12.9 W/kg; SAR(10 g) = 6.14 W/kg Maximum value of SAR (measured) = 21.1 W/kg
Report No.: BTL-FCC SAR-1-2401C209A_Appendix B. Page 1 of 2 Test Laboratory: BTL Inc. Date: 2024/5/14 B06_2.4G SRD_CH0_Rear Face_0mm D U T: Keyboard; Communication System: UID 0, BT (0); Frequency: 2402 MHz; Duty Cycle: 1:1 Medium parameters used (interpolated): f = 2402 MHz; σ = 1.783 S/m; ε r = 39.807; ρ = 1000 kg/m 3 Ambient Temperature:22.8 °C; Liquid Temperature:21.9 °C DASY Configuration: • Probe: EX3DV4 - SN7515; ConvF(7.45, 7.45, 7.45) @ 2402 MHz; Calibrated: 2023/12/14 • Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 Sn1390; Calibrated: 2023/11/20 • Phantom: ELI v5.0_Left; Type: QDOVA002AA; Serial: TP:1222 • DASY52 52.10.2(1495); SEMCAD X 14.6.12(7450) Area Scan (8x8x1): Measurement grid: dx=12mm, dy=12mm Maximum value of SAR (measured) = 0.192 W/kg Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 0 V/m; Power Drift = 0.00 dB Peak SAR (extrapolated) = 0.778 W/kg SAR(1 g) = 0.326 W/kg; SAR(10 g) = 0.125 W/kg Maximum value of SAR (measured) = 0.618 W/kg Report No.: BTL-FCC SAR-1-2401C209A_Appendix B. Page 2 of 2 Test Laboratory: BTL Inc. Date: 2024/5/14 B14_BLE_CH0_Rear Face_0mm D U T: Keyboard; Communication System: UID 10670 - AAA, Bluetooth Low Energy; Frequency: 2402 MHz; Duty Cycle: 1:1 Medium parameters used (interpolated): f = 2402 MHz; σ = 1.783 S/m; ε r = 39.807; ρ = 1000 kg/m 3 Ambient Temperature:22.8 °C; Liquid Temperature:21.9 °C DASY Configuration: • Probe: EX3DV4 - SN7515; ConvF(7.45, 7.45, 7.45) @ 2402 MHz; Calibrated: 2023/12/14 • Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 Sn1390; Calibrated: 2023/11/20 • Phantom: ELI v5.0_Left; Type: QDOVA002AA; Serial: TP:1222 • DASY52 52.10.2(1495); SEMCAD X 14.6.12(7450) Area Scan (8x8x1): Measurement grid: dx=12mm, dy=12mm Maximum value of SAR (measured) = 0.170 W/kg Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 0 V/m; Power Drift = 0.00 dB Peak SAR (extrapolated) = 0.787 W/kg SAR(1 g) = 0.327 W/kg; SAR(10 g) = 0.124 W/kg Maximum value of SAR (measured) = 0.622 W/kg
rn Co laboration with ,,~'\"1 11 / 1 ~,, ~ rhfi!~l w ~"'~~'.-Tl:!!ilii'\""J ~~~ m~~i.\ . fj~~CNAS&~t f/LTTL Add: No.52 HuaYuanBei Road, Haidian District, Beijing, 100191, Chi ~/..~~~ ~ CALIBRATION Tel: +86-10-62304633-2079 Fax: +86-10-62304633-2504 ''l,,f,ln\'~'' ~ CNAS L0570 E-mail: [email protected] http://www.chinattl.cn Client BTL Inc. Certificate No: Z21-60224 CALIBRATION CERTIFICATE Object D2450V2-SN: 919 Calibration Procedure(s) FF-Z11 .. 003-01 Calibration Procedures for dipole validation kits Calibration date: May 28,2021 This calibration Certificate documents the traceability to national standards, which realize the physical units of measurements (SI). The measurements and 1 the uncertainties with confidence probability are given on the following pages and are part of the certificate. All calibrations have been conducted humidity<70%. laboratory facility: environment temperature (22±3)°C and Calibration Equipment used (M&TE critical fqr calibration) Primary Standards ID# Cal Date (Calibrated by, Certificate No.) Scheduled Calibration Power Meter NRP2 106277 23-Sep-20 (CTTL, No.J20X08336) Sep~21 Power sensor NRP8S 104291 3-Sep-20 (CTTL, No.J20X08336) Sep-21 Reference Probe EX3DV4 SN 3846 26-Apr-21 (CTTL-SPEAG,No.Z21-60084) Apr-22 DAE4 SN 777 . 08-Jan-21 (CTTL-SPEAG, No.Z21-60003) Jan-22 Secondary Standards ID# Cal Date (Calibrated by, Certificate No.) Scheduled Cplibration Signal Generator E4438C MY49071430 01-Feb-21 (CTTL, No.J21X00593) Jan-22 NetworkAnalyzer E5071 C MY46110673 14-Jan-21 (CTTL, No.J21X00232) Jan-22 Name Function Signature Calibrated by: Zhao Jing SAR Test Engineer .~D Reviewed by: Lin Hao SAR Test Engineer ~~- Approved by: Qi Dianyuan SAR Project Leader ~ Issued: June 2, 2021 This calibration certificate shall not be reproduced except in full without written approval of the laboratory. Certificate No: Z21-60224 Page 1 of6 e a . CAU · ON lABORATORY Add: No.52 HuaYuanBei Road, Haidian b istrict, Beijing, 100191, China Tel: +86-1 0-62304633-2079 Fax: +86-10-62304633-2504 E-mail: [email protected] http://Www.chinattl.cn Glossary: l tissue simulating liquid TSL ConvF N/A sensitivity in TSL I NORMx,y,z not applicable or not measured ! l Calibration is Performed According to the Following Standards: a) IEEE Std 1528-2013, "IEEE Recommended Practice for Determining the Peak Spatial-Averaged Specific Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement Techniques", June 2013 b) IEC 62209-1, "Measurement pro·cedure for assessment of specific absorption rate of human exposure to radio frequency fiel; s from hand-h~ld and body-mounted wireless communication devices-Part 1: evice used next to the ear (Frequency range of 300M Hz to 6GHz)", July 2016 c) IEC 62209-2, "Procedure to me sure the Specific Absorption Rate (SAR) For wireless communication devices used in lose proximity to the human body (frequency range of 30MHz to 6GHz)", March 2010 d) KDB865664, SAR Measuremen1 Requirements for 100 MHz to 6 GHz Additional Documentation: ··' e) DASY4/5 System Handbook 1· Methods Applied and Interpretation of Parameters: • Measurement Conditions: Furtt~er details are available from the Validation Report at the end of the certificate. All figures sta ed in t~e certificate are valid at the frequency indicated. • Antenna Parameters with TSL': The dipole is mounted with the spacer to position its feed point exactly below the center.rnarkinQ~ of the flat phantom section, with the arms oriented parallel to the body axis. • Feed Point Impedance andRe urn Loss: These parameters are measured with the dipole positioned under the liquid fille< phantom. The impedance stated is transformed from the measurement at the SMA conn~ctor t~ the feed point. The Return Loss ensures low · reflected power. No uncertaint~ requir~d. . • Electrical Delay: One-way dela V between the SMA connector and the antenna feed point. No uncertainty required. 1 • SAR measured: SAR measure~ at the stated antenna input power. • SAR normalized: SAR as me~s ured, rnormalized to an input power of 1 W at the antenna • SAR for nominal TSL param te rs: Th~ measUired TSL parameters are used to calculate the connector. 1 , nominal SAR result. 1 • I The reported uncertainty of n easurfment is stated as the standard uncertainty of Measurement multiplied by t1E coverage fattor k=2, which for a normal distribution Corresponds to a coverage prc~>bability pf approximately 95%. Certificate No: Z21-60224 P~ge 2 of6 '.'~~~ Measurement Conditions DASY sy_stem configuration, as far as lilO g1ven on page . 1 DASY Version , DASY52l ~ V52.10.4 Extrapolation Advanced Extra~olation Phantom Triple Flat Phantom 5.1 C Distance Dipole Center -TSL 10 mm with Spacer Zoom Scan Resolution dx, dy, dz = 5 mm Frequency : .. ':#: 2450 MHz ± 1 MHz Head TSL parameters ~f:-ti : The following parameters and calculations were ClPPiied. Tempe ature Permittivity Conductivity Nominal Head TSL parameters 'j j Measured Head TSL parameters 1 Head TSL temperature change during test , SAR result with Head TSL 1 22.0 c 39.2 i (22.0 ± 0 2) oc 38.8 ±6% <1.0 c SAR averaged over 1 cm 3 (1 g) of :H~ad TSL Condition 2~0 mW input power SAR measured 1 I , I SAR for nominal Head TSL parameters normalized to 1 W I SAR averaged over 10 cm 3 (1 0 g) of Head TSL Condition SAR measured I SAR for nominal Head TSL parameters I Certificate No: Z21-60224 i 1 tl I• I 250 mW input power normalized to 1 W Page 3 of6 1.80 mho/m 1.81 mho/m ± 6% 13.1 W/kg 52.1 W/kg ± 18.8% (lc=2) 5.95 W/kg 23.7 W/kg ± 18.7% (lc=2)
品名:RFPCA470909IMAB301 History List 版本 REV. 修訂者 EDITOR 修訂頁次 PAGE 修訂內容 ITEMS OF CHANGE 申請日期 DATE 生效日期 VALID DATE ECN編號 ECN NO. A0 李欣樺 ALL New drawing release 2024/02/06 According to the date of PLM Release N/A A1 李欣樺 2 變更Layout 2024/03/14 According to the date of PLM Release N/A INPAQ TECHNOLOGY CO., LTD 2024/03/14 UNLESS OTHER SPECIFIED TOLERANCES ON: INPAQ TECHNOLOGY CO., LTD. X=N/A X.X=N/A X.XX=N/A ANGLES=N/A HOLEDIA=N/A SCALE:N/A UNIT:mm THIS DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF INPAQ TECHNOLOGY CO.,LTD.AND SHALL NOT BE REPRODUCED OR USED AS THE BASIS FOR THE MANUFACTURE OR SALE OF APPARATUS OR DEVICES WITHOUT PERMISSION DRAWN BY:李欣樺 CHECKED BY:詹惠雯 DESIGNED BY: 黃瑞郎 APPROVED BY:陳振榮 TITLE:RFPCA470909IMAB301 DOCUMENT ENS070032080-000803722237 SPEC REV. NO. A1 PAGE 1 OF 9 品名:RFPCA470909IMAB301 1. Explanation of part number: RF PCA 4709 09 I M A B 3 01 Type Code Product Code PCB Dimension (Unit: mm) Cable Length (unit: cm) Connector Brand Type of Connector Application Project status Wire Diameter Project RF Device PCB Antenna Per 2 digits of length, width e.g.: 3205 Length 32mm, Width 5mm 2 digits for cable length e.g.: 08 Length 8cm A: N C:MCX D:IPEX III E: IPEX IV F: IPEX A13 H: Hirose I: IPEX M: MMCX S: SMA T: TNC U:MURATA N: None A: Reverse Female B: Reverse Male F: Female M: Male N: None 0: 0GHz 3: 3GHz 5: 5GHz 6: 6GHz A: 2.4GHz ISM band B: GSM 900/1800 dual band G: GPS band L: 2.4/5.2/5.8 GHz tri-band R:902~928 MHz N: NFC T: LTE band W: WCDMA band B: MP T:During Test X: Pile Run 0:None 1:∅0.81 2:∅1.32 3:∅1.13 4:Low Loss ∅1.13 5:∅0.5 6:RG316 7: ∅1.37 8:RG178 9:Low Loss ∅1.37 01~99 series number 2. Electrical Specification: Item Specification Working Frequency Range 2.4~2.5 GHz Return Loss -10 dB(Max) VSWR 2 max. Gain 4.1 dBi Impedance 50 Ohm Nominal Radiation Omni-directional Polarization Linear Vertical Operation Temperature -20 C~+65 C INPAQ TECHNOLOGY CO., LTD 2024/03/14 UNLESS OTHER SPECIFIED TOLERANCES ON: INPAQ TECHNOLOGY CO., LTD. X=N/A X.X=N/A X.XX=N/A ANGLES=N/A HOLEDIA=N/A SCALE:N/A UNIT:mm THIS DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF INPAQ TECHNOLOGY CO.,LTD.AND SHALL NOT BE REPRODUCED OR USED AS THE BASIS FOR THE MANUFACTURE OR SALE OF APPARATUS OR DEVICES WITHOUT PERMISSION DRAWN BY:李欣樺 CHECKED BY:詹惠雯 DESIGNED BY: 黃瑞郎 APPROVED BY:陳振榮 TITLE:RFPCA470909IMAB301 DOCUMENT ENS070032080-000803722237 SPEC REV. NO. A1 PAGE 2 OF 9 3. Antenna Drawing: INPAQ TECHNOLOGY CO., LTD 2024/03/14 UNLESS OTHER SPECIFIED TOLERANCES ON: INPAQ TECHNOLOGY CO., LTD. X=N/A X.X=N/A X.XX=N/A ANGLES=N/A HOLEDIA=N/A SCALE:N/A UNIT:mm THIS DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF INPAQ TECHNOLOGY CO.,LTD.AND SHALL NOT BE REPRODUCED OR USED AS THE BASIS FOR THE MANUFACTURE OR SALE OF APPARATUS OR DEVICES WITHOUT PERMISSION DRAWN BY:李欣樺 CHECKED BY:詹惠雯 DESIGNED BY: 黃瑞郎 APPROVED BY:陳振榮 TITLE:RFPCA470909IMAB301 DOCUMENT ENS070032080-000803722237 SPEC REV. NO. A1 PAGE 5 OF 9 ■ ELECTRICAL CHARACTERISTICS S-Parameter INPAQ TECHNOLOGY CO., LTD 2024/03/14 UNLESS OTHER SPECIFIED TOLERANCES ON: INPAQ TECHNOLOGY CO., LTD. X=N/A X.X=N/A X.XX=N/A ANGLES=N/A HOLEDIA=N/A SCALE:N/A UNIT:mm THIS DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF INPAQ TECHNOLOGY CO.,LTD.AND SHALL NOT BE REPRODUCED OR USED AS THE BASIS FOR THE MANUFACTURE OR SALE OF APPARATUS OR DEVICES WITHOUT PERMISSION DRAWN BY:李欣樺 CHECKED BY:詹惠雯 DESIGNED BY: 黃瑞郎 APPROVED BY:陳振榮 TITLE:RFPCA470909IMAB301 DOCUMENT ENS070032080-000803722237 SPEC REV. NO. A1 PAGE 6 OF 9 ■Efficiency & Peak Gain INPAQ TECHNOLOGY CO., LTD 2024/03/14 UNLESS OTHER SPECIFIED TOLERANCES ON: INPAQ TECHNOLOGY CO., LTD. X=N/A X.X=N/A X.XX=N/A ANGLES=N/A HOLEDIA=N/A SCALE:N/A UNIT:mm THIS DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF INPAQ TECHNOLOGY CO.,LTD.AND SHALL NOT BE REPRODUCED OR USED AS THE BASIS FOR THE MANUFACTURE OR SALE OF APPARATUS OR DEVICES WITHOUT PERMISSION DRAWN BY:李欣樺 CHECKED BY:詹惠雯 DESIGNED BY: 黃瑞郎 APPROVED BY:陳振榮 TITLE:RFPCA470909IMAB301 DOCUMENT ENS070032080-000803722237 SPEC REV. NO. A1 PAGE 7 OF 9 ■ Radiation Patterns X-Z Plane Phi=0.00deg Gain . dB INPAQ TECHNOLOGY CO., LTD 2024/03/14 UNLESS OTHER SPECIFIED TOLERANCES ON: INPAQ TECHNOLOGY CO., LTD. X=N/A X.X=N/A X.XX=N/A ANGLES=N/A HOLEDIA=N/A SCALE:N/A UNIT:mm THIS DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF INPAQ TECHNOLOGY CO.,LTD.AND SHALL NOT BE REPRODUCED OR USED AS THE BASIS FOR THE MANUFACTURE OR SALE OF APPARATUS OR DEVICES WITHOUT PERMISSION DRAWN BY:李欣樺 CHECKED BY:詹惠雯 DESIGNED BY: 黃瑞郎 APPROVED BY:陳振榮 TITLE:RFPCA470909IMAB301 DOCUMENT ENS070032080-000803722237 SPEC REV. NO. A1 PAGE 8 OF 9 Y-Z Plane Phi=90.00deg Gain . dB INPAQ TECHNOLOGY CO., LTD 2024/03/14 UNLESS OTHER SPECIFIED TOLERANCES ON: INPAQ TECHNOLOGY CO., LTD. X=N/A X.X=N/A X.XX=N/A ANGLES=N/A HOLEDIA=N/A SCALE:N/A UNIT:mm THIS DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF INPAQ TECHNOLOGY CO.,LTD.AND SHALL NOT BE REPRODUCED OR USED AS THE BASIS FOR THE MANUFACTURE OR SALE OF APPARATUS OR DEVICES WITHOUT PERMISSION DRAWN BY:李欣樺 CHECKED BY:詹惠雯 DESIGNED BY: 黃瑞郎 APPROVED BY:陳振榮 TITLE:RFPCA470909IMAB301 DOCUMENT ENS070032080-000803722237 SPEC REV. NO. A1 PAGE 9 OF 9 X-Y Plane Theta=90.00deg Gain . dB
Report No.: BTL-FCCP-1-2401C209 Page 1 of 62 FCC Radio Test Report FCC ID: RWO-RZ030513 This report concerns: Original Grant Project No. : 2401C209 Equipment : Gaming Keyboard Brand Name : RAZER, Test Model : RZ03-0513 Series Model : RZ03-0513XXXX-XXXX (X can be 0-9 or A-Z) Applicant : Razer Inc. Address : 9 Pasteur, Suite 100, Irvine, CA92618, USA Manufacturer : RAZER (ASIA-PACIFIC) PTE. LTD. Address : Razer SEA HQ, 1 One-north Crescent, #02-01, Singapore 138538 Factory : RAZER TECHNOLOGY AND DEVELOPMENT (SHENZHEN) CO., LTD Address : East Wing, 3rd Floor, Block 2, Phase 1 of Vision Shenzhen Business Park Keji South Road, Hi-Tech Industrial Park, Shenzhen 518057, China Date of Receipt : Mar. 01, 2024 Date of Test : Mar. 01, 2024 ~ Mar. 31, 2024 Issued Date : Apr. 07, 2024 Report Version : R00 Test Sample : Sample No.: DG202403058 for conducted, DG20240301128 for AC power line conducted emissions, DG20240301128 and DG20240321225 for radiated emissions. Standard(s) : FCC CFR Title 47, Part 15, Subpart C The above equipment has been tested and found compliance with the requirement of the relative standards by BTL Inc. Prepared by : Vincent Tan Approved by : Chay Cai Room 108, Building 2, No.1, Yile Road, Songshan Lake Zone, Dongguan City, Guangdong, People’s Republic of China. Tel: +86-769-8318-3000 Web: www.newbtl.com Service mail: [email protected] Report No.: BTL-FCCP-1-2401C209 Page 2 of 62 Declaration BTL represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with standards traceable to international standard(s) and/or national standard(s). BTL's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. BTL shall have no liability for any declarations, inferences or generalizations drawn by the client or others from BTL issued reports. The report must not be used by the client to claim product certification, approval, or endorsement by A2LA or any agency of the U.S. Government. This report is the confidential property of the client. As a mutual protection to the clients, the public and ourselves, the test report shall not be reproduced, except in full, without our written approval. BTL’s laboratory quality assurance procedures are in compliance with the ISO/IEC 17025: 2017 requirements, and accredited by the conformity assessment authorities listed in this test report. BTL is not responsible for the sampling stage, so the results only apply to the sample as received. The information, data and test plan are provided by manufacturer which may affect the validity of results, so it is manufacturer’s responsibility to ensure that the apparatus meets the essential requirements of applied standards and in all the possible configurations as representative of its intended use. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Please note that the measurement uncertainty is provided for informational purpose only and are not use in determining the Pass/Fail results. Report No.: BTL-FCCP-1-240…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15C | 2.40 GHz - 2.48 GHz | 2.70 mW |
Gaming Controller
Equipment Class
DTS - Digital Transmission SystemGaming Mouse
Equipment Class
DTS - Digital Transmission SystemGaming Chair
Equipment Class
DTS - Digital Transmission SystemWireless Dongle
Equipment Class
DTS - Digital Transmission SystemWireless Mouse
Equipment Class
DTS - Digital Transmission System