Razer Inc.

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Apr 01, 2026
Application Purpose
Original Equipment
Equipment Note
Wireless Keyboard
Frequency Range
2402.00000000 - 2480.00000000
Company
Razer Inc.
Country
United States

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Rev 1/26/2023 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 16-Apr--2025 Ref: Attestation Statements Part 2.911(d)(7) Filing Grantee Code: RWO Razer Inc. (“the applicant”) certifies that, as of the date of the filing of the application, we designate ourselves as the U.S. agent for service of process. Designated U.S. Agent Information: FRN: 0022386734 Name: Address: Contact Person: Email: Tel.: Razer Inc. 9 Pasteur, Irvine, California, United States Johnsen Tia [email protected] 760 579 0180 Sincerely, ________________ Johnsen Tia Associate VP, Regulatory & Compliance

Attestation Statements

Razer Inc. CERTIFICATIONS CONCERNING “COVERED” EQUIPMENT Date:2025-12-30 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, Maryland 21046 FCC ID: RWO-RZ030544 To Whom It May Concern: As required by section 2.911(d)(5)(i), [Razer Inc.] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. As required by section 2.911(d)(5)(i), [Razer Inc.] (“the applicant”) certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24 -886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). As required by section 2.911(d)(5)(ii), [Razer Inc.] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [is not] identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Thank you for your attention to this matter. Sincerely yours, Signature Printed Name: Johnsen Tia Company: Razer Inc. Job Title: Director, Regulatory & Compliance Email: [email protected] Telephone: 760 579 0180

Cover Letter(s)

Razer Inc. Declaration of Authorization We Name: Razer Inc. Address: 9 Pasteur City: Irvine State: California Country: United States Declare that: Name Representative of agent: Ms. Rose Liu Agent Company name: BTL Inc. Address: No.3 Jinshagang 1st Road, Shixia, Dalang Town City: Dong Guan Country: China is authorized to apply for Certification and signing related documents of the following product(s), including 731 form(s): Product description: Wireless Keyboard Type designation: RZ03-0544, RZ03-0544XXXX-XXXX(X can be 0-9 or A-Z) Trademark: RAZER FCC ID : RWO-RZ030544 on our behalf. Date: 2025-12-30 City: Irvine Name: Johnsen Tia Function: Director, Regulatory & Compliance Signature: ............................... Notes: (1): Required for FCC application (2): For FCC it must be the Grantee Code “owner” or the authorized agent.

Cover Letter(s)

FCC, Request for non-disclosure Date: 02-01-2022 RF_501, Issue 10 Company Name: Razer Inc. Address : 9 Pasteur, City: Irvine, CA92618 Country: United States To: Kiwa N etherlands B.V., Dept. FCC TCB Wilmersdorf 50 7327 AC Apeldoorn The Netherlands Subject: Request for confidentiality FCC ID: RWO-RZ030544 Reference number: ###### Dear FCC TCB, 1. Long-Term Confidentiality Pursuant to 47 CFR Section 0.459(a) & (b), we hereby requests non-disclosure and confidential treatment of the following materials submitted in support of FCC certification application: Bill(s) of Material Block Diagrams Operational Description Schematic Diagrams Tune-up Procedure Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. 2. Short-Term Confidentiality (STC) Pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, a pplicant hereby requests Short-Term Confidential treatment of the following materials (See notes below): Internal Photos User’s Manual Test Set-up Photos External Photos Justification: This document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor unfair advantage in the market. Planned Release Date STC: 180 days from date of grant (notes 2, 3, 4, 5) Date: 2025-12-30 Name and signature of applicant: Johnsen Tia Notes: 1) A document or type of document can only have ONE type of confidentiality! 2) Short-Term confidentiality is in principle for 45 days from date of grant; it can be extended max 3 times (total time 180 days max.)! The planned date should state in the RF731 application form. 3) FCC must be informed when marketing begins earlier. 4) Release takes place automatically thus extension must be requested in time. Telefication does not remind you of this! 5) Request for extension or for release must be received by Kiwa NL B.V. at least 7 days before date of actual marketing or before expiration of the STC period

ID Label/Location Info

MODEL NO. [型号/型號]: RZ03-0544 Wireless Keyboard/ 无线键盘/無線鍵盤 RATING [额定/額定]: 5V 2.0A P/NO. [ 代号/代號]: Serial No: SI25WWFAAAXXXXX DUMMY Color : Metallic silver This device is manufactured under one or more of the following patents: U.S. Pat. Nos. 8,367,947; 8,605,063; 9,841,825; 8,566,431; 9,235,277 P.R.C. Pat. Nos. ZL200680054309.2; ZL201410360065.7; ZL200780100766.5; ZL 200980102126.7; ZL201180058303.3 TW Pat. Nos. I 370219 ; I 507922; I 484339; I 493360 KR Pat. Nos. 10-1278955; 10-1451249; 10-1433277; 10-1600078; 10-1770419. Further patents pending in various territories. R-R-RAZ- RZ03-0544 XXX-XXXXXX CAN ICES (B) / NMB (B) IS 13252(Part1)/ IEC 60950-1 R-XXXXXXXX www.bis.gov.in MADE IN CHINA © RAZER INC. 中国制造/中國製造 Razer (Europe) GmbH Alter Teichweg 25, 22081 Hamburg, Germany CMIIT ID: XXXXXXXXXXXX FCC ID: RWO-RZ030544 IC: 8092D-RZ030544 Typing in an awkward position or for long periods may cause repetitive stress or related injuries. CCAHXXXXXXXXXX PID Graphic CMF 1:1 scale Rev2510_ by GW@Razer 2025 = 25 (SILITEN China) = SI Razer Serial Number format *Mandatory in 15 Alphanumeric Manufacturer code Year code Week code (01 to 52) Product Serial code *Assigned by Razer Product Serialize running no. *Start from 00001 Complete sku P/N. reference: RZ03-05440100-R3M1 Font: RazerF5 Regular, 6pt Secondary print process 5.2 x 5.2 mm QR CODE label location

RF Exposure Info

Report No.: BTL-FCCP-3-2507C043 Report Version: R01 Page 1 of 4 FCC RF EXPOSURE REPORT FCC ID: RWO-RZ030544 Project No. : 2507C043 Equipment : Wireless Keyboard Brand Name : RAZER, Test Model : RZ03-0544 Model Name : RZ03-0544, RZ03-0544XXXX-XXXX (X can be 0-9 or A-Z) Hardware Version : V0.6 Software Version : V1.00.03.00 Applicant : Razer Inc. Address : 9 Pasteur, Irvine, CA 92618, USA Manufacturer : RAZER (ASIA-PACIFIC) PTE. LTD. Address : Razer SEA HQ, 1 One-north Crescent, #02-01, Singapore 138538 Factory : RAZER TECHNOLOGY AND DEVELOPMENT (SHENZHEN) CO., LTD Address : East Wing, 3rd Floor, Block 2, Phase 1 of Vision Shenzhen Business Park Keji South Road, Hi-Tech Industrial Park, Shenzhen 518057, China Date of Receipt : Oct. 09, 2025 Date of Test : Oct. 09, 2025 ~ Oct. 30, 2025 Issued Date : Mar. 24, 2026 Test Sample : Engineering Sample No.: DG2025100917-1 Standard(s) : FCC Guidelines for Human Exposure IEEE C95.1 & KDB447498 D01 The above equipment has been tested and found compliance with the requirement of the relative standards by BTL Inc. (Dongguan) Prepared by : Chella Zheng Approved by : Chay Cai No.3, Jinshagang 1st Road, Dalang, Dongguan, Guangdong People’s Republic of China. Tel: +86-769-8318-3000 Web: www.newbtl.com Service mail: [email protected] Report No.: BTL-FCCP-3-2507C043 Report Version: R01 Page 2 of 4 REVISION HISTORY Report No. Version Description Issued Date Note BTL-FCCP-3-2507C043 R00 Original Report. Jan. 04, 2026 Invalid BTL-FCCP-3-2507C043 R01 This report added Note(2) in page4. lt is a revision of the report BTL-FCCP-3-2507C043 R00. This is a newly released report. replacing the BTL-FCCP-3-2507C043 R00 report. Mar. 24, 2026 Valid Report No.: BTL-FCCP-3-2507C043 Report Version: R01 Page 3 of 4 1. GENERAL CONCULUSION According to FCC KDB447498 D01, Appendix A, SAR Test Exclusion Thresholds for 100 MHz – 6 GHz and ≤ 50 mm, the 1-g and 10-g SAR test exclusion thresholds are determined by the following: [(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR, and ≤ 7.5 for 10-g extremity SAR, where  f(GHz) is the RF channel transmit frequency in GHz  Power and distance are rounded to the nearest mW and mm before calculation  The result is rounded to one decimal place for comparison Appendix A - SAR Test Exclusion Thresholds for 100 MHz - 6 GHz and < 50 mm MHz 5 10 15 20 25 30 35 40 45 50 mm 150 39 77 116 155 194 232 271 310 349 387 SAR Test Exclusion Thresholds (mW) 300 27 55 82 110 137 164 192 219 246 274 450 22 45 67 89 112 134 157 179 201 224 835 16 33 49 66 82 98 115 131 148 164 900 16 32 47 63 79 95 111 126 142 158 1500 12 24 37 49 61 73 86 98 110 122 1900 11 22 33 44 54 65 76 87 98 109 2450 10 19 29 38 48 57 67 77 86 96 3600 8 16 24 32 40 47 55 63 71 79 5200 7 13 20 26 33 39 46 53 59 66 5400 6 13 19 26 32 39 45 52 58 65 5800 6 12 19 25 31 37 44 50 56 62 Report No.: BTL-FCCP-3-2507C043 Report Version: R01 Page 4 of 4 2. TABLE FOR FILED ANTENNA Ant. Manufacturer P/N Antenna Type Connector Gain (dBi) 1 Dongguan Yirui Electronic Technology Co., Ltd. 382-00757-003FPC N/A 1.45 Note: The antenna gain is provided by the manufacturer. 3. TEST RESULTS Function Frequency (MHz) Max. Output Power (dBm) Max. Output Power (mW) Max. e.i.r.p. (mW) Exclusion Thresholds Limit Result BLE 2480 5.34 3.4198 4.7753 1.0771 7.5 Pass SRD 2480 5.31 3.3963 4.7424 1.0697 7.5 Pass Note: (1) No SAR evaluation required since transmitter power is below FCC threshold. (2) The use distance of this product is 5 mm. End of Test Report

Test Report

Report No.: BTL-FCCP-1-2507C043 Report Version: R01 Page 1 of 62 FCC Radio Test Report FCC ID: RWO-RZ030544 This report concerns: Original Grant Project No. : 2507C043 Equipment : Wireless Keyboard Brand Name : RAZER, Model Name : RZ03-0544, RZ03-0544XXXX-XXXX (X can be 0-9 or A-Z) Applicant : Razer Inc. Address : 9 Pasteur, Irvine, CA 92618, USA Manufacturer : RAZER (ASIA-PACIFIC) PTE. LTD. Address : Razer SEA HQ, 1 One-north Crescent, #02-01, Singapore 138538 Factory : RAZER TECHNOLOGY AND DEVELOPMENT (SHENZHEN) CO., LTD Address : East Wing, 3rd Floor, Block 2, Phase 1 of Vision Shenzhen Business Park Keji South Road, Hi-Tech Industrial Park, Shenzhen 518057, China Date of Receipt : Oct. 09, 2025 Date of Test : Oct. 09, 2025 ~ Oct. 30, 2025 Issued Date : Nov. 13, 2025 Test Sample : Sample No.: DG2025100917 for conducted emissions and radiated emissions, DG2025100917-1 for power, DG2025100916-3 for others. Standard(s) : FCC CFR Title 47, Part 15, Subpart C The above equipment has been tested and found compliance with the requirement of the relative standards by BTL Inc. (Dongguan) Prepared by : Chella Zheng Approved by : Chay Cai No.3, Jinshagang 1st Road, Dalang, Dongguan, Guangdong People’s Republic of China. Te l : + 8 6-769-8318-3000 Web: www.newbtl.com Service mail: [email protected] Report No.: BTL-FCCP-1-2507C043 Report Version: R01 Page 2 of 62 Declaration BTL represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with standards traceable to international standard(s) and/or national standard(s). BTL's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. BTL assumes no responsibility for the data provided by the customer, any statements, inferences or generalizations drawn by the customer or others from the reports issued by BTL. The report must not be used by the client to claim product certification, approval, or endorsement by A2LA or any agency of the U.S. Government. This report is the confidential property of the client. As a mutual protection to the clients, the public and ourselves, the test report shall not be reproduced, except in full, without our written approval. BTL’s laboratory quality assurance procedures are in compliance with the ISO/IEC 17025: 2017 requirements, and accredited by the conformity assessment authorities listed in this test report. BTL is not responsible for the sampling stage, so the results only apply to the sample as received. The information, data and test plan are provided by manufacturer which may affect the validity of results, so it is manufacturer’s responsibility to ensure that the apparatus meets the essential requirements of applied standards and in all the possible configurations as representative of its intended use. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Please note that the measurement uncertainty is provided for informational purpose only and are not use in determining the Pass/Fail results. Report No.: BTL-FCCP-1-2507C043 Report Version: R01 Page 3 of 62 Table of Contents Page REVISION HISTORY 6 1 . APPLICABLE STANDARDS 7 2 . SUMMARY OF TEST RESULTS 7 2.1 TEST FACILITY 8 2.2 MEASUREMENT UNCERTAINTY 8 2.3 TEST ENVIRONMENT CONDITIONS 9 3 . GENERAL INFORMATION 10 3.1 GENERAL DESCRIPTION OF EUT 10 3.2 DESCRIPTION OF TEST MODES 12 3.3 PARAMETERS OF TEST SOFTWARE 13 3.4 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 14 3.5 SUPPORT UNITS 14 3.6 CUSTOMER INFORMATION DESCRIPTION 14 4 . AC POWER LINE CONDUCTED EMISSIONS 15 4.1 LIMIT 15 4.2 TEST PROCEDURE 15 4.3 DEVIATION FROM TEST STANDARD 15 4.4 TEST SETUP 16 4.5 EUT OPERATING CONDITIONS 16 4.6 TEST RESULTS 16 5 . RADIATED EMISSIONS 17 5.1 LIMIT 17 5.2 TEST PROCEDURE 18 5.3 DEVIATION FROM TEST STANDARD 19 5.4 TEST SETUP 19 5.5 EUT OPERATING CONDITIONS 21 5.6 TEST RESULT - 9 KHZ TO 30 MHZ 21 5.7 TEST RESULT - 30 MHZ TO 1000 MHZ 21 5.8 TEST RESULT - ABOVE 1000 MHZ 21 6 . BANDWIDTH 22 6.1 LIMIT 22 Report No.: BTL-FCCP-1-2507C043 Report Version: R01 Page 4 of 62 Table of Contents Page 6.2 TEST PROCEDURE 22 6.3 DEVIATION FROM STANDARD 22 6.4 TEST SETUP 22 6.5 EUT OPERATION CONDITIONS 22 6.6 TEST RESULTS 22 7 . MAXIMUM OUTPUT POWER 23 7.1 LIMIT 23 7.2 TEST PROCEDURE 23 7.3 DEVIATION FROM STANDARD 23 7.4 TEST SETUP 23 7.5 EUT OPERATION CONDITIONS 23 7.6 TEST RESULTS 23 8 . CONDUCTED SPURIOUS EMISSION 24 8.1 LIMIT 24 8.2 TEST PROCEDURE 24 8.3 DEVIATION FROM STANDARD 25 8.4 TEST SETUP 25 8.5 EUT OPERATION CONDITIONS 25 8.6 TEST RESULTS 25 9 . POWER SPECTRAL DENSITY 26 9.1 LIMIT 26 9.2 TEST PROCEDURE 26 9.3 DEVIATION FROM STANDARD 26 9.4 TEST SETUP 26 9.5 EUT OPERATION CONDITIONS 26 9.6 TEST RESULTS 26 10 . MEASUREMENT INSTRUMENTS LIST 27 APPENDIX A - AC POWER LINE CONDUCTED EMISSIONS 29 APPENDIX B - RADIATED EMISSION - 9 KHZ TO 30 MHZ 32 APPENDIX C - RADIATED EMISSION - 30 MHZ TO 1000 MHZ 37 APPENDIX D - RADIATED EMISSION - ABOVE 1000 MHZ 40 APPENDIX E - BANDWIDTH 53 Report No.: BTL-FCCP-1-2507C043 Report Version: R01 Page 5 of 62 Table of Contents Page APPENDIX F - MAXIMUM OUTPUT POWER 56 APPENDIX G - CONDUCTED SPURIOUS EMISSION 58 APPENDIX H - POWER SPECTRAL DENSITY 61 Report No.: BTL-FCCP-1-2507C043 Report Version: R01 Page 6 of 62 REVISION HISTORY Report No. Version Description Issued Date Note BTL-FCCP-1-2507C043 R00 Original Report. Nov. 10, 2025 Invalid BTL-FCCP-1-2507C043 R01 This report revised the P/N of antenna in section 3.1. lt is a revision of the report BTL-FCCP-1-2507C043 R00. This is a newly released report. replacing the BTL-FCCP-1-2507C043 R00 report. Nov. 13, 2025 Valid Report No.: BTL-FCCP-1-2507C043 Report Version: R01 Page…

Text truncated - open the document above for the full version.

Test Report

Report No.: BTL-FCCP-2-2507C043 Report Version: R01 Page 1 of 54 FCC Radio Test Report FCC ID: RWO-RZ030544 This report concerns: Original Grant Project No. : 2507C043 Equipment : Wireless Keyboard Brand Name : RAZER, Model Name : RZ03-0544, RZ03-0544XXXX-XXXX (X can be 0-9 or A-Z) Applicant : Razer Inc. Address : 9 Pasteur, Irvine, CA 92618, USA Manufacturer : RAZER (ASIA-PACIFIC) PTE. LTD. Address : Razer SEA HQ, 1 One-north Crescent, #02-01, Singapore 138538 Factory : RAZER TECHNOLOGY AND DEVELOPMENT (SHENZHEN) CO., LTD Address : East Wing, 3rd Floor, Block 2, Phase 1 of Vision Shenzhen Business Park Keji South Road, Hi-Tech Industrial Park, Shenzhen 518057, China Date of Receipt : Oct. 09, 2025 Date of Test : Oct. 09, 2025 ~ Oct. 30, 2025 Issued Date : Nov. 13, 2025 Test Sample : Sample No.: DG2025100917 for conducted emissions and radiated emissions, DG2025100917-1 for power, DG2025100916-3 for others. Standard(s) : FCC CFR Title 47, Part 15, Subpart C The above equipment has been tested and found compliance with the requirement of the relative standards by BTL Inc. (Dongguan) Prepared by : Chella Zheng Approved by : Chay Cai No.3, Jinshagang 1st Road, Dalang, Dongguan, Guangdong People’s Republic of China. Te l : + 8 6-769-8318-3000 Web: www.newbtl.com Service mail: [email protected] Report No.: BTL-FCCP-2-2507C043 Report Version: R01 Page 2 of 54 Declaration BTL represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with standards traceable to international standard(s) and/or national standard(s). BTL's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. BTL assumes no responsibility for the data provided by the customer, any statements, inferences or generalizations drawn by the customer or others from the reports issued by BTL. The report must not be used by the client to claim product certification, approval, or endorsement by A2LA or any agency of the U.S. Government. This report is the confidential property of the client. As a mutual protection to the clients, the public and ourselves, the test report shall not be reproduced, except in full, without our written approval. BTL’s laboratory quality assurance procedures are in compliance with the ISO/IEC 17025: 2017 requirements, and accredited by the conformity assessment authorities listed in this test report. BTL is not responsible for the sampling stage, so the results only apply to the sample as received. The information, data and test plan are provided by manufacturer which may affect the validity of results, so it is manufacturer’s responsibility to ensure that the apparatus meets the essential requirements of applied standards and in all the possible configurations as representative of its intended use. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Please note that the measurement uncertainty is provided for informational purpose only and are not use in determining the Pass/Fail results. Report No.: BTL-FCCP-2-2507C043 Report Version: R01 Page 3 of 54 Table of Contents Page REVISION HISTORY 6 1 . APPLICABLE STANDARDS 7 2 . SUMMARY OF TEST RESULTS 7 2.1 TEST FACILITY 8 2.2 MEASUREMENT UNCERTAINTY 8 2.3 TEST ENVIRONMENT CONDITIONS 9 3 . GENERAL INFORMATION 10 3.1 GENERAL DESCRIPTION OF EUT 10 3.2 DESCRIPTION OF TEST MODES 12 3.3 PARAMETERS OF TEST SOFTWARE 12 3.4 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 13 3.5 SUPPORT UNITS 13 3.6 CUSTOMER INFORMATION DESCRIPTION 13 4 . AC POWER LINE CONDUCTED EMISSIONS 14 4.1 LIMIT 14 4.2 TEST PROCEDURE 14 4.3 DEVIATION FROM TEST STANDARD 14 4.4 TEST SETUP 15 4.5 EUT OPERATING CONDITIONS 15 4.6 TEST RESULTS 15 5 . RADIATED EMISSIONS 16 5.1 LIMIT 16 5.2 TEST PROCEDURE 17 5.3 DEVIATION FROM TEST STANDARD 18 5.4 TEST SETUP 18 5.5 EUT OPERATING CONDITIONS 20 5.6 TEST RESULT - 9 KHZ TO 30 MHZ 20 5.7 TEST RESULT - 30 MHZ TO 1000 MHZ 20 5.8 TEST RESULT - ABOVE 1000 MHZ 20 6 . BANDWIDTH 21 6.1 LIMIT 21 Report No.: BTL-FCCP-2-2507C043 Report Version: R01 Page 4 of 54 Table of Contents Page 6.2 TEST PROCEDURE 21 6.3 DEVIATION FROM STANDARD 21 6.4 TEST SETUP 21 6.5 EUT OPERATION CONDITIONS 21 6.6 TEST RESULTS 21 7 . MAXIMUM OUTPUT POWER 22 7.1 LIMIT 22 7.2 TEST PROCEDURE 22 7.3 DEVIATION FROM STANDARD 22 7.4 TEST SETUP 22 7.5 EUT OPERATION CONDITIONS 22 7.6 TEST RESULTS 22 8 . CONDUCTED SPURIOUS EMISSION 23 8.1 LIMIT 23 8.2 TEST PROCEDURE 23 8.3 DEVIATION FROM STANDARD 24 8.4 TEST SETUP 24 8.5 EUT OPERATION CONDITIONS 24 8.6 TEST RESULTS 24 9 . POWER SPECTRAL DENSITY 25 9.1 LIMIT 25 9.2 TEST PROCEDURE 25 9.3 DEVIATION FROM STANDARD 25 9.4 TEST SETUP 25 9.5 EUT OPERATION CONDITIONS 25 9.6 TEST RESULTS 25 10 . MEASUREMENT INSTRUMENTS LIST 26 APPENDIX A - AC POWER LINE CONDUCTED EMISSIONS 28 APPENDIX B - RADIATED EMISSION - 9 KHZ TO 30 MHZ 31 APPENDIX C - RADIATED EMISSION - 30 MHZ TO 1000 MHZ 36 APPENDIX D - RADIATED EMISSION - ABOVE 1000 MHZ 39 APPENDIX E - BANDWIDTH 47 Report No.: BTL-FCCP-2-2507C043 Report Version: R01 Page 5 of 54 Table of Contents Page APPENDIX F - MAXIMUM OUTPUT POWER 49 APPENDIX G - CONDUCTED SPURIOUS EMISSION 51 APPENDIX H - POWER SPECTRAL DENSITY 53 Report No.: BTL-FCCP-2-2507C043 Report Version: R01 Page 6 of 54 REVISION HISTORY Report No. Version Description Issued Date Note BTL-FCCP-2-2507C043 R00 Original Report. Nov. 10, 2025 Invalid BTL-FCCP-2-2507C043 R01 This report revised the P/N of antenna in section 3.1. lt is a revision of the report BTL-FCCP-2-2507C043 R00. This is a newly released report. replacing the BTL-FCCP-2-2507C043 R00 report. Nov. 13, 2025 Valid Report No.: BTL-FCCP-2-2507C043 Report Version: R01 Page…

Text truncated - open the document above for the full version.

Test Report

XT-ENG-1002-03C 东莞市旭田电子有限公司 Dongguan Siliten Electronics Co., Ltd. 汇田科技(泰国)有限公司 HUI TIAN TECHNOLOGY (THAILAND) Co., Ltd. SPECIFICATION FOR APPROVAL 材 料 承 认 书 厂商工程: Vendor ENG 邓志颖 厂商审核: Vendor Reviewer 黄文斌 厂商批准: Vendor Approval by 刘华宋 旭田RD承认: SILITEN RD RD审核: RD Reviewer RD批准: RD Approval by 旭田ENG承认 SILITEN ENG ENG审核: ENG Reviewer ENG批准: ENG Approval by 厂商章印: Manufacturer's seal 发行章: Issuance chapter:: 东莞市亿瑞电子科技有限公司 地址:东莞市塘厦镇田心社区丰达工业区丰达路 7 栋 13 号二楼 电话:0769-82016588 传真:0769-82011600 承 认 书 SPECIFICATION FOR APPROVAL 客 户 名 称 CUSTOMER NAME: 旭 田 产 品 名 称 PRODUCT NAME: 2.4G FPC板内置天线(馈线:1.13黑色=200mm+端子) BS1C200F3D125A 客 户 料 号 CUSTOMER P/N: 382-00757-003 (机种:6580) 亿 瑞 料号 YR P/N: BS1C200F3D125A REV: A MANUFACTURER SIGNATURE CUSTOMER SIGNATURE CHECKED BY: 刘建群 APPROVED BY: EVINE DATE: 2025/9/10 东莞市亿瑞电子科技有限公司 地址:东莞市塘厦镇田心社区丰达工业区丰达路 7 栋 13 号二楼 电话:0769-82016588 传真:0769-82011600 Contents ltem Description 1.---------------------------------------------------------------规格表 2.---------------------------------------------------------------成品图 3.---------------------------------------------------------------测试报告 4.---------------------------------------------------------------实物图 5.-----------------------------------------------------------厂商承认保证书 6.----------------------------------------------------------原材料使用保证书 7.---------------------------------------------------- ----------材料成分表 东莞市亿瑞电子科技有限公司 地址:东莞市塘厦镇田心社区丰达工业区丰达路 7 栋 13 号二楼 电话:0769-82016588 传真:0769-82011600 1.规格表: 产品主要技术参数 主要技术指标 Main technical specifications 频率范围 (MHZ) 2400~2500 Frequency Range (MHZ) 2400~2500 特性阻抗(Ω) 50±10 Impedance(Ω) 50±10 峰值增益(dBi) 1.67 Peak Gain(dBi) 1.67 输出电压 驻波比 ≤1.92 VSWR ≤1.92 最大功率 1W Admitted Power 1W 极化方式 线极化 Polarization Line,Vertical 连接方式 同轴线+端子 Connector Type RF Cable+端子 物理性能 Physical Properties 天线本体材料 FPC Antenna Base FPC 工作温度 -50°C~+80°C Operating Temp -50°C~+80°C 保存温度 -50°C~+80°C Storage Temp -50°C~+80°C 东莞市亿瑞电子科技有限公司 地址:东莞市塘厦镇田心社区丰达工业区丰达路 7 栋 13 号二楼 电话:0769-82016588 传真:0769-82011600 2.成品图: 东莞市亿瑞电子科技有限公司 地址:东莞市塘厦镇田心社区丰达工业区丰达路 7 栋 13 号二楼 电话:0769-82016588 传真:0769-82011600 3.测试报告 3.1:网络分析仪测试报告 3.2:暗室2D、3DRaditation Pattern(整机数据) 3.2.1 效率及增益 Passive Test For WIFI2.4 Freq Effi Effi Gain (MHz) (%) (dB) (dBi) 2400 57.81 -2.38 1.45 2410 57.5 -2.4 1.44 2420 56.67 -2.47 1.35 2430 56.75 -2.46 1.33 2440 57.35 -2.41 1.37 2450 58.18 -2.35 1.38 2460 57.29 -2.42 1.23 2470 58.03 -2.36 1.19 2480 60.73 -2.17 1.39 2490 65.45 -1.84 1.67 2500 65.44 -1.84 1.62 东莞市亿瑞电子科技有限公司 地址:东莞市塘厦镇田心社区丰达工业区丰达路 7 栋 13 号二楼 电话:0769-82016588 传真:0769-82011600 3.2.2 2D/3D场型图 东莞市亿瑞电子科技有限公司 地址:东莞市塘厦镇田心社区丰达工业区丰达路 7 栋 13 号二楼 电话:0769-82016588 传真:0769-82011600 东莞市亿瑞电子科技有限公司 地址:东莞市塘厦镇田心社区丰达工业区丰达路 7 栋 13 号二楼 电话:0769-82016588 传真:0769-82011600 4.实物图 XT-ENG-1002-02B 厂商规格承认保证书(电子类) 2025年 09月 10 日 机种:6580 版本: A 编号: MSC- 材 料 名 称 料 号 厂 商 承认结果 天线 382-00757-003 东莞市亿瑞电子科技有限公司 OK 尺寸检验: NO 重点检查项目 规 格 测量工具 测试数量 结果 1 2 3 1 馈线长 200±3 卡尺 200.2 200.0 200.5 OK 2 FPC 长 33±0.5 卡尺 33.02 33.06 33.01 OK 3 FPC 宽 15±0.2 卡尺 15.03 15.02 15.07 OK 4 5 6 功能检验: NO 重点检查项目 规 格 測試儀器 測試條件 测试数量 结果 1 2 3 1 网络测试 驻波比 网络分析仪5071B≤1.92 1.55 1.11 1.1.44 OK 2 OTA 测试 天线效率 OTA暗房 >40% 57.81 58.18 65.44 OK 3 4 5 6 外观检验: NO 检查项目 结果 1 装机实配 OK 2 3 4 5 其它检验: NO 检查项目 结 果 资料目录: 1 承认书封页 其 他 参照图纸管控要求提供资料:如CPK、FAI、QE信赖性实 验报告、拉拔力测试记录 2 厂商承认保证书 3 规格书 4 5 6 7 备注: 1、厂商送货必须与此承认书规格一致,如有不符,产生损失由厂商承担。 2、承认书各类资料按照目录顺序装订成册。 原材料使用保证书 兹保证本公司 天线 所使用之材料及规格,确为 旭田工程承认书中指定材料,未经旭田同意不会使用非旭田指定之材 料及供应商,并且符合有害物质管理规定,与所送检测样品材质及零 部件相符合,如在旭田电子厂及客户端,发现其材质及规格不符合, 本公司愿承担一切法律责任及赔偿相关损失。 详细规格内容如下;(针对原材料材质规格的描述及其本体的规格的 描述) 特此声明! 立保证书公司名称:东莞市亿瑞电子科技有限公司 公司法定代表人签章: 公司印鉴: 签章日期:2025-9-10 旭田 电 子有限公司材料成分表 东莞市亿瑞电子科技有限 公司材料成份表 XT- Q RA-1013-02B SGS 编号 : TAOEC23000540236 Pb Cd Hg Cr(VI) PBB PBDE 所含部件 部件材 质 名 供货商 MSDS 报告 重量(g) 产品 料 号 序 号 材料中有害物質含量(PPM) 重量 (g) 产品 名 称 有效期至 有害物質 測試報告編號 备注 Pb Cd H g Cr(VI) PBB PBDE 1 FPC FPA3315-7A fpc 1000 100 1000 1000 1000 1000 2025/10/31 馈线 /同 轴线 1000 100 1000 1000 1000 1000 2025/12/8 SHAEC23017333402 SZXEC23001776704 端子 / 磷 铜 1000 100 1000 - 1000 1000 2025/10/5 TAOEC23000540236 核准:__ _ 黄文斌 审查:__刘杰_______ 制表:__ 谭旭英 _______

Contact Information

Applicant

Johnsen Tia(Associate VP, Regulatory & Compliance)
[email protected]Fax: 760 579 0182

Technical Contact

RAZER INC.Johnsen Tia
[email protected]Fax: 7605790182

9 Pasteur, · Irvine, 92618 · United States

Test Firm

BTL Inc. (Dongguan)Sophia Huang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz3.40 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. This is a portable device. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. End users must be provided with specific operating instructions for satisfying RF exposure compliance.

Other Applications from Razer Inc.

RWO-RZ060519

Gaming Controller

Sep 02, 2026

Equipment Class

DTS - Digital Transmission System
RWO-RZ010566

Gaming Mouse

Aug 26, 2026

Equipment Class

DTS - Digital Transmission System
RWO-RZ380426

Gaming Chair

Jun 26, 2026

Equipment Class

DTS - Digital Transmission System
RWO-DGRFG8

Wireless Dongle

May 28, 2026

Equipment Class

DTS - Digital Transmission System
RWO-RZ010569

Wireless Mouse

May 27, 2026

Equipment Class

DTS - Digital Transmission System