Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
iHub‐3000B Installation Guide When used with the Concord 4 Security Panel Installation Guide for the iHub‐3000B‐ADT and the Concord 4 Security Panel Copyright © 2010 ADT Security Service, Inc. All rights reserved. About This Guide This document does not cover the physical installation and special configurations that may be required for the security system components. Refer to the manufacturer's documentation for each device for those specifics. Overview of the Installation Process The installation utilizes a streamlined process for setting up the system. All components are individually activated and tested before being physically installed in their final locations, whenever possible. 2 Installation Guide for the iHub‐3000B‐ADT and the Concord 4 Security Panel Activating the Service with Concord 4 Security Panel Before you begin the activation process, you must make some hardware connections. Since each security panel is different, follow the instructions in the next section, "Connecting the Hardware ", for the specific security panel you are installing. Then please follow the instructions in "Activating the Service" on page 3 for all security panels. Connecting the Hardware Follow the procedure in this section that applies to the security panel you are installing. Note: Do not connect the iHub gateway's power supply to an electrical outlet until you are instructed to do so by the activation wizard. If you power on the gateway before it is connected to the Internet, it cannot retrieve the information it requires on power up. If you have already done this, simply unplug it and continue with the following instructions. If you are installing a Touch Screen, do not connect it to a power source until you are instructed to do so by the activation wizard. To connect the gateway to the Concord 4 security panel: 1. Wire the Automation Module to the Concord's bus, as described in the GE Installation Manual. 2. Gateway model iHub‐3000B‐ADT, connectors are labeled Tx+, Tx‐, Rx+, and Rx‐. The automation module connectors are labeled the same but might include a/b instead of +/‐. Using a standard 4‐ wire security cable, connect the ports on the gateway's RS422 bus to the Automation Module as follows: Gateway Automation Module Tx+ Rx+ or Rxb Tx‐ Rx‐ or Rxa Rx+ Tx+ or Txb Rx‐ Tx‐ or Txa Do not connect any antenna provided to the port on the gateway labeled Cellular. Cellular communications from the iHub are not used. Activating the Service To activate the service: 1. On a computer connected to the Internet, open a web browser, and go to the activation URL portal.adtpulse.com/activation . 2. Enter your username and password, and click Sign In. The activation wizard displays the Welcome screen. 3 Installation Guide for the iHub‐3000B‐ADT and the Concord 4 Security Panel 3. After reading the information on the screen, click Continue. The Select Hardware screen appears. 4. Select the type of hardware you are installing, and click Continue. The Enter Activation Key screen appears. 4 Installation Guide for the iHub‐3000B‐ADT and the Concord 4 Security Panel 5. Enter the activation key, and click Continue. Note: The activation key contains numbers from 0‐9 and letters from A‐F. There are no letters O or I. The activation process begins, and then the Select Service Options screen appears. 6. Select the appropriate options for the installation based on the information on the Installer Reference Sheet, and click Continue. The Physical Setup screen appears. The exact wording on this screen varies based on the security panel you are installing and the service options you selected on the previous screen. 5 Installation Guide for the iHub‐3000B‐ADT and the Concord 4 Security Panel 7. Follow the instructions on the screen, and then click Continue. A message displays a progress bar, which indicates approximately how much longer the activation will take. If an upgrade is required, the activation application performs the upgrade automatically. If the power light blinks amber, it indicates that an upgrade is in process. 6 Installation Guide for the iHub‐3000B‐ADT and the Concord 4 Security Panel Assigning the Site Owner The next step in the procedure is to set the site owner, configure the site settings, and sign in to the web portal to complete the installation process. The user selection screen should still be displayed on the computer. This screen offers the option of creating a new user account or using an existing user account. Take one of the following actions: If the customer does not have a user account, click Create New User Account. The Create User Account screen appears. Continue with "Creating a User Account" on page 7. If the customer already has a user account, enter their username on the right side of the screen, and click Continue. Skip the next section and continue with "Configuring Site Information" on page 8. Creating a User Account For customers who do not yet have a user account, you must create one. The user account enables you to complete the installation process and then for the customer to access their security system online or from a mobile device anytime they want. (If the customer already has a user account, skip this section.) To create a new user account: 1. On the Activate Service sign in screen, click Create New Account. The Create User Account screen appears. 7 Installation Guide for the iHub‐3000B‐ADT and the Concord 4 Security Panel 2. Enter the required information for the customer. Enter the username that the customer prefers. Depending on how your the system is configured, the username might be restricted to a certain number of characters. 3. Click Continue. The Site Information screen appears. Continue with "Configuring Site Information" on page 8. Configuring Site Information When you click Continue on either the user selection screen or the Create User Account screen, the Site Information screen appears. 8 Installation Guide for the iHub‐3000B‐ADT and the Concord 4 Security Panel No…
Text truncated - open the document above for the full version.
Date:April 29, 2010 Subject: Ad Hoc Mode Function Declaration S23-IHUB3000B To Whom it may concern, This device is acting as slave and operating on 2.4GHz band. Ad Hoc function is available and not able to work on non-US frequencies. Please contact the one signed below or the authorized agent for this filing. Thank you. Regards, Yours sincerely, iControl Networks Inc. 3045 Park Blvd., Palo Alto, CA 94306 U.S.A
Date:April 29, 2010 Subject: DoC declaration To Whom it may concern, We, as the grantee of this project FCC ID: S23-IHUB3000B , would like to declare that the composite portion categorized as computer peripheral has been authorized under the Declaration of Conformity procedures. Regards, Yours sincerely, iControl Networks Inc. 3045 Park Blvd., Palo Alto, CA 94306 U.S.A
Date: June 1, 2010 Federal Communications Commission Authorization and Evaluation Division FCC ID: S23-IHUB3000B Confidentiality Request Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, the Applicant hereby requests confidential treatment of information accompanying this Application as outlined below: 1. Schematics 2. Operational Description 3. Block diagram The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457, disclosure of this Application and all accompanying documentation will not be made before the date of the Grant for this application. Yours sincerely, iControl Networks Inc. 3045 Park Blvd., Palo Alto, CA 94306 U.S.A.
Date:June 1, 2010 Federal Communications Commission 7435 Oakland Mills Road Columbia MD 21046 c.c. Compliance Certification Services Certification Division 47173 Benicia Street Fremont, CA 94538, USA To whom it may concern: I, the undersigned, hereby authorize Mr. James Lee / Section Manager of Compliance Certification Services Inc. and hereafter referred to as CCS, to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by Mr. James Lee / Section Manager of Compliance Certification Services Inc. on our behalf shall have the same effect as acts of our own. I, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). In authorizing CCS as our agent, we still recognize that we are responsible to: a) comply with the relevant provisions of the certification program; b) make all necessary arrangements for the conduct of the evaluation, including provision for examining documentation and access to all areas, records (including internal audit reports) and personnel for the purposes of evaluation (e.g. testing, inspection, assessment, surveillance, reassessment) and resolution of complaints; c) make claims regarding certification only in respect of the scope for which certification has been granted; d) do not use our product certification in such a manner as to bring the Certification Division into disrepute and not make any statement regarding our product certification which the Certification Division may consider misleading or unauthorized; e) upon suspension or cancellation of certification, discontinue use of all advertising matter that contains any reference thereto and return any certification documents as required by the Certification Division; f) use certification only to indicate the products are certified as being in conformity with specified standards; g) endeavor to ensure that no certificate or report nor any part thereof is used in a misleading manner; h) ensure that any reference to our product certification in communication media such as documents, brochures or advertising, complies with the requirements of the Certification Division; i) keep a record of all complaints made known to the us relating to the product’s compliance with requirements of the relevant standard and to make these records available to the Certification Division when requested; j) take appropriate action with respect to such complaints and any deficiencies found in products or services that affect compliance with the requirements for certification; k) document the actions taken. This authorization is valid until further written notice from the applicant. Yours sincerely, iControl Networks Inc. 3045 Park Blvd., Palo Alto, CA 94306 U.S.A.
Compliance Certification Services Inc. Report No.: T100222209 Date of Issue: August 5, 2010 A1 - 1 Total Page: 12 Rev. 00 APPENDIX 1 - PHOTOGRAPHS OF EUT EXTERNAL PHOTOGRAPHS OF EUT Compliance Certification Services Inc. Report No.: T100222209 Date of Issue: August 5, 2010 A1 - 2 Rev. 00 Compliance Certification Services Inc. Report No.: T100222209 Date of Issue: August 5, 2010 A1 - 3 Rev. 00 Compliance Certification Services Inc. Report No.: T100222209 Date of Issue: August 5, 2010 A1 - 4 Rev. 00 Compliance Certification Services Inc. Report No.: T100222209 Date of Issue: August 5, 2010 Page 5 Rev. 00 Compliance Certification Services Inc. Report No.: T100222209 Date of Issue: August 5, 2010 Page 6 Rev. 00 Compliance Certification Services Inc. Report No.: T100222209 Date of Issue: August 5, 2010 Page 7 Rev. 00 Compliance Certification Services Inc. Report No.: T100222209 Date of Issue: August 5, 2010 Page 8 Rev. 00
Model: i HUB - 3000B
Compliance Certification Services Inc. Report No.: T100222209 Date of Issue: April 14, 2010 Page 9 Rev. 00 INTERNAL PHOTOGRAPHS OF EUT Compliance Certification Services Inc. Report No.: T100222209 Date of Issue: April 14, 2010 Page 10 Rev. 00 Compliance Certification Services Inc. Report No.: T100222209 Date of Issue: April 14, 2010 Page 11 Rev. 00 Compliance Certification Services Inc. Report No.: T100222209 Date of Issue: April 14, 2010 Page 12 Rev. 00
Compliance Certification Services Inc. Report No.: T100222209-RP1 FCC ID: S23-IHUB3000B Date of Issue: August 5, 2010 Page 68 Rev. 00 APPENDIX I RADIO FREQUENCY EXPOSURE LIMIT Systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess of the Commission's guidelines. See §15.247(i) and §1.1307(b)(1) of this chapter. EUT Specification EUT Home Monitoring Gateway Frequency band (Operating) WLAN: 2.412GHz ~ 2.462GHz WLAN: 5.18GHz ~ 5.32GHz / 5.50GHz ~ 5.70GHz WLAN: 5.745GHz ~ 5.825GHz Others Device category Portable (<20cm separation) Mobile (>20cm separation) Others Exposure classification Occupational/Controlled exposure (S = 5mW/cm 2 ) General Population/Uncontrolled exposure (S=1mW/cm 2 ) Antenna diversity Single antenna Multiple antennas Tx diversity Rx diversity Tx/Rx diversity Max. output power IEEE 802.11b: 15.41 dBm (34.76mW)) IEEE 802.11g: 13.32 dBm (21.48mW) Antenna gain (Max) 5 dBi (Numeric gain: 3.16) Evaluation applied MPE Evaluation* SAR Evaluation N/A Remark: 1. The maximum output power is 15.41dBm (34.76mW) at 2412MHz (with 3.16 numeric antenna gain.) 2. DTS device is not subject to routine RF evaluation; MPE estimate is used to justify the compliance. 3. For mobile or fixed location transmitters, no SAR consideration applied. The maximum power density is 1.0 mW/cm2 even if the calculation indicates that the power density would be larger. TEST RESULTS No non-compliance noted. Compliance Certification Services Inc. Report No.: T100222209-RP1 FCC ID: S23-IHUB3000B Date of Issue: August 5, 2010 Page 69 Rev. 00 Calculation Given d GP E ×× = 30 & 3770 2 E S = Where E = Field strength in Volts / meter P = Power in Watts G = Numeric antenna gain d = Distance in meters S = Power density in milliwatts / square centimeter Combining equations and re-arranging the terms to express the distance as a function of the remaining variables yields: 2 3770 30 d GP S ×× = Changing to units of mW and cm, using: P (mW) = P (W) / 1000 and d (cm) = d(m) / 100 Yields () () 2 2 0796.0 100/3770 1000/30 d GP d GP S × ×= × ×× = Equation 1 Where d = Distance in cm P = Power in mW G = Numeric antenna gain S = Power density in mW / cm 2 Maximum Permissible Exposure Substituting the MPE safe distance using d = 20 cm into Equation 1: Yields GPS××=000199.0 Where P = Power in mW G = Numeric antenna gain S = Power density in mW / cm 2 Compliance Certification Services Inc. Report No.: T100222209-RP1 FCC ID: S23-IHUB3000B Date of Issue: August 5, 2010 Page 70 Rev. 00 IEEE 802.11b mode: EUT output power = 34.76mW Numeric Antenna gain = 3.16 Æ Power density = 0.0219 mW / cm 2 IEEE 802.11g mode: EUT output power = 21.48 mW Numeric Antenna gain = 3.16 Æ Power density = 0.0135 mW / cm 2 (For mobile or fixed location transmitters, the maximum power density is 1.0 mW/cm 2 even if the calculation indicates that the power density would be larger.)
Compliance Certification Services Inc. Report No.: T100222209-RP1 FCC ID: S23-IHUB3000B Date of Issue: August 5, 2010 Note: This report shall not be reproduced except in full, without the written approval of Compliance Certification Services Inc. This document may be altered or revised by Compliance Certification Services Inc. personnel only, and shall be noted in the revision section of the document. Page 1 Total Page: 74 Rev. 00 FCC 47 CFR PART 15 SUBPART C TEST REPORT For Home Monitoring Gateway Model: iHUB-3000B, iHUB-3000B-ADT, 600-1049-EXT-GWBB Trade Name: iControl Issued to iControl Networks, Inc. 3045 Park Blvd., Palo Alto, CA 94306 U.S.A. Issued by Compliance Certification Services Inc. No. 11, Wu-Gong 6 th Rd., Wugu Industrial Park, Taipei Hsien 248, Taiwan (R.O.C.) http://www.ccsrf.com [email protected] Compliance Certification Services Inc. Report No.: T100222209-RP1 FCC ID: S23-IHUB3000B Date of Issue: August 5, 2010 Page 2 Rev. 00 TABLE OF CONTENTS 1. TEST RESULT CERTIFICATION....................................................................................................3 2. EUT DESCRIPTION ...........................................................................................................................4 3. TEST METHODOLOGY ....................................................................................................................5 3.1 EUT CONFIGURATION........................................................................................................................5 3.2 EUT EXERCISE....................................................................................................................................5 3.3 GENERAL TEST PROCEDURES.............................................................................................................5 3.4 FCC PART 15.205 RESTRICTED BANDS OF OPERATIONS.........................................................6 3.5 DESCRIPTION OF TEST MODES...........................................................................................................7 4. INSTRUMENT CALIBRATION........................................................................................................8 4.1 MEASURING INSTRUMENT CALIBRATION......................................................................................8 4.2 MEASUREMENT EQUIPMENT USED .........................................................................................8 4.3 MEASUREMENT UNCERTAINTY ...............................................................................................9 5. FACILITIES AND ACCREDITATIONS ........................................................................................10 5.1 FACILITIES.......................................................................................................................................10 5.2 EQUIPMENT......................................................................................................................................10 5.3 TABLE OF ACCREDITATIONS AND LISTINGS.....................................................................................11 6. SETUP OF EQUIPMENT UNDER TEST .......................................................................................12 6.1 SETUP CONFIGURATION OF EUT.......................................................................................................12 6.2 SUPPORT EQUIPMENT ...............................................................................................................12 7. FCC PART 15.247 REQUIREMENTS.............................................................................................13 7.1 6DB BANDWIDTH.............................................................................................................................13 7.2 PEAK POWER....................................................................................................................................18 7.3 AVERAGE POWER............................................................................................................................20 7.4 BAND EDGES MEASUREMENT ................................................................................................21 7.5 PEAK POWER SPECTRAL DENSITY....................................................................................................38 7.6 SPURIOUS EMISSIONS.................................................................................................................43 7.7 POWERLINE CONDUCTED EMISSIONS...............................................................................................65 APPENDIX I RADIO FREQUENCY EXPOSURE ...............................................................................68 APPENDIX II PHOTOGRAPHS OF TEST SETUP .............................................................................71 APPENDIX 1 - PHOTOGRAPHS OF EUT Compliance Certification Services Inc. Report No.: T100222209-RP1 FCC ID: S23-IHUB3000B Date of Issue: August 5, 2010 Page 3 Rev. 00 1. TEST RESULT CERTIFICATION Applicant: iControl Networks, Inc. 3045 Park Blvd., Palo Alto, CA 94306 U.S.A. Equipment Under Test: Home Monitoring Gateway Tr a d e N a m e : iControl Model: iHUB-3000B, iHUB-3000B-ADT, 600-1049-EXT-GWBB Date of Test: February 6 ~ August 3, 2010 APPLICABLE STANDARDS STANDARD TEST RESULT FCC 47 CFR Part 15 Subpart C No non-compliance noted Deviation from Applicable Standard N/A We hereby certify that: The above equipment was tested by Compliance Certification Services Inc. The test data, data evaluation, test procedures, and equipment configurations shown in this report were made in accordance with the procedures given in ANSI C63.4: 2003 and the energy emitted by the sample EUT tested as described in this report is in compliance with the requirements of FCC Rules Part 15.207, 15.209, 15.247. The test results of this report relate only to the tested sample EUT identified in this report. Approved by: Reviewed by: Rex Lai Gina Lo Section Manager…
Text truncated - open the document above for the full version.
Compliance Certification Services Inc. Report No.: T100222209-RP1 FCC ID: S23-IHUB3000B Date of Issue: August 5, 2010 Page 71 Rev. 00 APPENDIX II PHOTOGRAPHS OF TEST SETUP CONDUCTED EMISSION SETUP PHOTOS Compliance Certification Services Inc. Report No.: T100222209-RP1 FCC ID: S23-IHUB3000B Date of Issue: August 5, 2010 Page 72 Rev. 00 Radiated Emissions Setup Photos For 2dBi Compliance Certification Services Inc. Report No.: T100222209-RP1 FCC ID: S23-IHUB3000B Date of Issue: August 5, 2010 Page 73 Rev. 00 For 5dBi Compliance Certification Services Inc. Report No.: T100222209-RP1 FCC ID: S23-IHUB3000B Date of Issue: August 5, 2010 Page 74 Rev. 00 Powerline Conducted Emissions Setup Photos
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 35.00 mW |

Home Monitoring Gateway
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Home Security Camera
Equipment Class
DTS - Digital Transmission System
Low Power Security Transceiver
Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
Low power security transceiver
Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver